Search PubMed⌕ Search

Biomedical subjects

R D Smith

Publications and source records attributed to R D Smith.

At least 37 records · Page 2Linked to original sources

High-throughput peptide identification from protein digests using data-dependent multiplexed tandem FTICR mass spectrometry coupled with capillary liquid chromatography.

Tandem mass spectrometry (MS/MS) plays an important role in the unambiguous identification and structural elucidation of biomolecules. In contrast to conventional MS/MS approaches for protein identification where an individual polypeptide is sequentially selected and dissociated, a multiplexed-MS/MS approach increases throughput by selecting several peptides for simultaneous dissociation using either infrared multiphoton dissociation (IRMPD) or multiple frequency sustained off-resonance irradiation (SORI) collisionally induced dissociation (CID). The high mass measurement accuracy and resolution of FTICR combined with knowledge of peptide dissociation pathways allows the fragments arising from several different parent ions to be assigned. Herein we report the application of multiplexed-MS/MS coupled with on-line separations for the identification of peptides present in complex mixtures (i.e., whole cell lysate digests). Software was developed to enable "on-the-fly" data-dependent peak selection of a subset of polypeptides from each FTICR MS acquisition. In the subsequent MS/MS acquisitions, several coeluting peptides were fragmented simultaneously using either IRMPD or SORI-CID techniques. The utility of this approach has been demonstrated using a bovine serum albumin tryptic digest separated by capillary LC where multiple peptides were readily identified in single MS/MS acquisitions. We also present initial results from multiplexed-MS/MS analysis of a D. radiodurans whole cell digest to illustrate the utility of this approach for high-throughput analysis of a bacterial proteome.

Amino Acid Sequence↗

High-throughput proteomics using high-efficiency multiple-capillary liquid chromatography with on-line high-performance ESI FTICR mass spectrometry.

We report on the design and application of a high-efficiency multiple-capillary liquid chromatography (LC) system for high-throughput proteome analysis. The multiple-capillary LC system using commercial LC pumps was operated at a pressure of 10,000 psi to deliver mobile phases through a novel passive feedback valve arrangement that permitted mobile-phase flow path switching and efficient sample introduction. The multiple-capillary LC system uses several serially connected dual-capillary column devices. The dual-capillary column approach eliminates the time delays for column regeneration (or equilibration) since one capillary column was used for a separation while the other was being washed. Several serially connected dual-capillary columns and electrospray ionization (ESI) sources were operated independently and can be used either for "backup" operation or for parallel operation with other mass spectrometers. This high-efficiency multiple-capillary LC system utilizes switching valves for all operations, enabling automated operation. The separation efficiency of the dual-capillary column arrangement, optimal capillary dimensions (column length and packed particle size), capillary regeneration conditions, and mobile-phase compositions and their compatibility with electrospray ionization were investigated. A high magnetic field (11.4 T) Fourier transform ion cyclotron resonance (FTICR) mass spectrometer was coupled on-line with this high-efficiency multiple-capillary LC system using an ESI interface. The capillary LC provided a peak capacity of approximately 650, and the 2-D capillary LC-FTICR analysis provided a combined resolving power of > 6 x 10(7) components. For yeast cytosolic tryptic digests > 100,000 polypeptides were detected, and approximately 1,000 proteins could be characterized from a single capillary LC-FTICR analysis using the high mass measurement accuracy (approximately 1 ppm) of FTICR, and likely more if LC retention time information were also exploited for peptide identification.

Chromatography, Liquid↗

Phosphoprotein isotope-coded affinity tag approach for isolating and quantitating phosphopeptides in proteome-wide analyses.

A method has been developed that utilizes phosphoprotein isotope-coded affinity tags (PhIAT) that combines stable isotope and biotin labeling to enrich and quantitatively measure differences in the O-phosphorylation states of proteins. The PhIAT labeling approach involves hydroxide ion-mediated beta-elimination of the O-phosphate moiety and the addition of 1,2-ethanedithiol containing either four alkyl hydrogens (EDT-D0) or four alkyl deuteriums (EDT-D4) followed by biotinylation of the EDT-D0/D4 moiety using (+)-biotinyl-iodoacetamidyl-3,6-dioxaoctanediamine. The PhIAT reagent, which contains the nucleophilic sulfhydryl and isotopic label covalently linked to a biotin moiety, was synthesized and has the potential utility to reduce the O-phosphorylation derivatization into a one-step process. The PhIAT labeling approach was initially demonstrated using the model phosphoprotein beta-casein. After proteolytic digestion, the PhIAT-labeled peptides were affinity isolated using immobilized avidin and analyzed using capillary reversed-phase liquid chromatography-mass spectrometry. PhIAT-labeled beta-casein peptides corresponding to peptides containing known sites of O-phosphorylation were isolated and identified. The PhIAT labeling method was also applied to a yeast protein extract. The PhIAT labeling technique provides a reliable method for making quantitative measurements of differences in the O-phosphorylation state of proteins.

Affinity Labels↗

Quantitative analysis of bacterial and mammalian proteomes using a combination of cysteine affinity tags and 15N-metabolic labeling.

We describe the combined use of 15N-metabolic labeling and a cysteine-reactive biotin affinity tag to isolate and quantitate cysteine-containing polypeptides (Cys-polypeptides) from Deinococcus radiodurans as well as from mouse B16 melanoma cells. D. radiodurans were cultured in both natural isotopic abundance and 15N-enriched media. Equal numbers of cells from both cultures were combined and the soluble proteins extracted. This mixture of isotopically distinct proteins was derivatized using a commercially available cysteine-reactive reagent that contains a biotin group. Following trypsin digestion, the resulting modified peptides were isolated using immobilized avidin. The mixture was analyzed by capillary reversed-phase liquid chromatography (LC) online with ion trap mass spectrometry (MS) as well as Fourier transform ion cyclotron resonance (FTICR) MS. The resulting spectra contain numerous pairs of Cyspolypeptides whose mass difference corresponds to the number of nitrogen atoms present in each of the peptides. Designation of Cys-polypeptide pairs is also facilitated by the distinctive isotopic distribution of the 15N-labeled peptides versus their 14N-labeled counterparts. Studies with mouse B16 cells maintained in culture allowed the observation of hundreds of isotopically distinct pairs of peptides by LC-FTICR analysis. The ratios of the areas of the pairs of isotopically distinct peptides showed the expected 1:1 labeling of the 14N and 15N versions of each peptide. An additional benefit from the present strategy is that the 15N-labeled peptides do not display significant isotope-dependent chromatographic shifts from their 14N-labeled counterparts, therefore improving the precision for quantitating peptide abundances. The methodology presented offers an alternate, cost-effective strategy for conducting global, quantitative proteomic measurements.

Animals↗

High-efficiency capillary isoelectric focusing of protein complexes from Escherichia coli cytosolic extracts.

High-efficiency capillary isoelectric focusing (cIEF) separations of protein complexes obtained from soluble protein fractions are demonstrated. Size-exclusion chromatography was used as a first dimension separation to fractionate putative protein complexes with apparent molecular masses of up to 1,500,000 from an Escherichia coli cytosolic fraction. Non-denaturing cIEF separations using highly hydrophilic polymer-coated capillaries constituted the second dimension. The conditions developed produced reproducible and high-efficiency separations, corresponding to approximately 2 x 10(6) theoretical plates and peak capacities of approximately 10(3) for pH 3-10 cIEF separations in 65 cm long capillaries. Combination of the two non-denaturing separation dimensions permitted isolation and analysis of individual protein complexes from complicated biological samples. Studies indicated that many E. coli complexes were stable on the time scale of the cIEF separations, but were degraded upon more extended periods of storage on ice, necessitating rapid sample processing and fast analysis techniques.

Bacterial Proteins↗

Packed capillary reversed-phase liquid chromatography with high-performance electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry for proteomics.

In this study, high-efficiency packed capillary reversed-phase liquid chromatography (RPLC) coupled on-line with high-performance Fourier transform ion cyclotron resonance (FTICR) mass spectrometry has been investigated for the characterization of complex cellular proteolytic digests. Long capillary columns (80-cm) packed with small (3-micron) C18 bonded particles provided a total peak capacity of approximately 1000 for cellular proteolytic polypeptides when interfaced with an ESI-FTICR mass spectrometer under composition gradient conditions at a pressure of 10,000 psi. Large quantities of cellular proteolytic digests (e.g., 500 micrograms) could be loaded onto packed capillaries of 150-micron inner diameter without a significant loss of separation efficiency. Precolumns with suitable inner diameters were found useful for improving the elution reproducibility without a significant loss of separation quality. Porous particle packed capillaries were found to provide better results than those containing nonporous particles because of their higher sample capacity. Two-dimensional analyses from the combination of packed capillary RPLC with high-resolution FTICR yield a combined capacity for separations of > 1 million polypeptide components and simultaneously provided information for the identification of the separated components based upon the accurate mass tag concept previously described.

Chromatography, Liquid↗

Generation of multiple electrosprays using microfabricated emitter arrays for improved mass spectrometric sensitivity.

Arrays of microelectrospray emitters were fabricated on polycarbonate substrates using a laser etching technique. Stable multielectrosprays were successfully generated in the liquid flow rate range relevant to mass spectrometric applications. Comparison of electrosprays generated from the microfabricated emitter array and conventional fused-silica capillaries showed similar spray characteristics and reliability. Higher total electrospray ion currents were observed as the number of electrosprays increased at a given total liquid flow rate. Consistent with the theoretical prediction, the total spray current at a constant total liquid flow rate was shown experimentally to be approximately proportional to the square root of the number of electrosprays. It is further projected that when total flow rate is optimized the maximum achievable total current will be proportional to the number of emitters. Evaluation of the multielectrospray device using a triple quadrupole mass spectrometer showed a factor of 2-3 sensitivity enhancement for the spray numbers ranging from two to nine compared to a conventional single electrospray ionization source under the same operating conditions.

Algorithms↗

Design and performance of an ESI interface for selective external ion accumulation coupled to a Fourier transform ion cyclotron mass spectrometer.

The coupling of Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) with electrospray ionization has advanced the analysis of large biopolymers and provided the basis for high-throughput protein characterization (e.g., for rapid "proteome" analyses). In this work, the combination of high-performance capillary liquid chromatography with FTICR mass spectrometry and external ion accumulation has been shown to increase both sensitivity and analysis duty cycle. Instrument versatility is further improved by ion preselection followed by ion accumulation in an external linear quadrupole ion trap. The interface was tested with a 3.5-T FTICR mass spectrometer and evaluated with a number of peptides and proteins whose molecular weights ranged from 500 to 66000. A significant increase in the sensitivity, duty cycle, and dynamic range over that of the previously used accumulated trapping was achieved, exhibiting a detection limit of approximately 10 zmol (approximately 6000 molecules) for smaller proteins such as cytochrome c. Capillary LC external accumulation interface with FTICR was successfully applied for the study of whole-proteome mouse tryptic digests.

Animals↗

Theory versus practice: a review of 'willingness-to-pay' in health and health care.

This paper is based upon an extensive review of 71 willingness-to-pay (WTP) surveys of health and health care published in English during the period 1985--1998. The aim of the paper is to outline the arguments advanced for the superiority of WTP over quality-adjusted-life-years (QALYs) as a measure of benefit of health care programmes, and to review how empirical WTP studies adhere to their implications. An important argument is that WTP enables a more comprehensive valuation of benefits than QALYs. Our main focus is therefore to provide a careful review of the scenario descriptions used in the surveys, according to which types of benefits are being valued, and how comprehensively the descriptions are presented. Furthermore, the 'cost-benefit argument', that WTP can assist in improving social efficiency, is discussed before we inquire into the extent to which the studies actually compare WTP with social costs.

Attitude to Health↗

Rapid quantitative measurements of proteomes by Fourier transform ion cyclotron resonance mass spectrometry.

The patterns of gene expression, post-translational modifications, protein/biomolecular interactions, and how these may be affected by changes in the environment, cannot be accurately predicted from DNA sequences. Approaches for proteome characterization are generally based upon mass spectrometric analysis of in-gel digested two dimensional polyacrylamide gel electrophoresis (2-D PAGE) separated proteins, allowing relatively rapid protein identification compared to conventional approaches. This technique, however, is constrained by the speed of the 2-D PAGE separations, the sensitivity limits intrinsic to staining necessary for protein visualization, the speed and sensitivity of subsequent mass spectrometric analyses for identification, and the limited ability for accurate quantitative measurements based on differences in spot intensity. We are presently developing alternative approaches for proteomics based upon the combination of fast capillary electrophoresis, or other suitable chromatographic separations, and the high mass accuracy and sensitivity obtainable with unique Fourier transform ion cyclotron resonance (FTICR) mass spectrometers available at our laboratory. Several approaches are presently being pursued; one based upon the analysis of intact proteins and the second upon approaches for global protein digestion and accurate peptide mass analysis. Quantitation of protein/peptide levels are based on using two or more stable-isotope labeled versions of proteomes which are combined to obtain precise quantitation of relative protein abundances. We describe the status of our efforts towards the development of a high-throughput proteomics capability and present initial results for application to several microorganisms and discuss our efforts for extending the developed capability to mammalian proteomes.

Bacterial Proteins↗

The relative sensitivity of willingness-to-pay and time-trade-off to changes in health status: an empirical investigation.

This paper directly compares the relative sensitivity of time-trade-off (TTO) and willingness-to-pay (WTP) values obtained for various levels of change in health status. This was achieved by administering a TTO and WTP survey to a population of 50 subjects, assessing their valuation of various degrees of change in health status. It was found that, overall, WTP is more sensitive than TTO in distinguishing between different dimensions of health at the same nominal level of health status (only four WTP values not significantly different, compared with eight TTO values). In addition, WTP was also more sensitive to differences in quality of life between different levels of health within each dimension (all values significantly different from each other, with TTO yielding three insignificant relationships). These results tentatively suggest, therefore, that WTP seems to be a more sensitive measure of change in health status than TTO.

Adult↗

A new technique for unbiased external ion accumulation in a quadrupole two-dimensional ion trap for electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.

External ion accumulation in a two-dimensional (2D) multipole trap has been shown to increase the sensitivity, dynamic range and duty cycle of a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. However, it is important that trapped ions be detected without significant bias at longer accumulation times in the external 2D multipole trap. With increasing ion accumulation time pronounced m/z discrimination was observed when trapping ions in an accumulation quadrupole. In this work we show that superimposing lower rf-amplitude dipolar excitation over the main rf-field in the accumulation quadrupole results in disruption of the m/z discrimination and can potentially be used to achieve unbiased external ion accumulation with FTICR.

Angiotensin I↗

Dynamically assisted gated trapping for Fourier transform ion cyclotron mass spectrometry.

An efficient approach for trapping ions and enhancing signal based on 'adiabatic amplitude reduction' for Fourier transform ion cyclotron resonance (FTICR) mass spectrometry is described and evaluated. This method is a modification to the widely used gated trapping technique in which the trapping potential is raised adiabatically rather than instantaneously (non-adiabatically). Compared with non-adiabatic gated trapping, the final amplitudes of ion axial oscillations and energies are lower in the proposed method. All performance aspects of the FTICR spectrum (e.g., peak intensities, mass resolution, and mass accuracy) improve significantly compared to the conventional gated trapping technique.

Amino Acid Sequence↗

Optimal pressure conditions for unbiased external ion accumulation in a two-dimensional radio-frequency quadrupole for Fourier transform ion cyclotron resonance mass spectrometry.

When combined with on-line separations (e.g., capillary liquid chromatography (LC)), Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) provides a powerful tool for biological applications, and particularly proteomic studies. The sensitivity, dynamic range, and duty cycle provided by FTICR-MS have been shown to be increased by ion trapping and accumulation in a two-dimensional (2D) radio-frequency (rf)-only multipole positioned externally to an FTICR cell. However, it is important that ions be detected across the desired m/z range without a significant bias. In this work we found that pressure inside the accumulation rf-quadrupole plays an important role in obtaining "unbiased" ion accumulation. Pressure optimization was performed in both pulsed and continuous modes. It was found that unbiased accumulation in a 2D rf-only quadrupole could be achieved in the pressure range of 5 x 10(-4) to 5 x 10(-3) Torr. External ion accumulation performed at the optimal pressure resulted in an increase in both the spectrum acquisition rates and dynamic range.

Algorithms↗

Epidemiology for the equine practitioner.

In this article, I have discussed the principles and methods of outbreak investigation, reinforcing important concepts with examples from the veterinary literature. The approach presented is applicable to outbreaks caused by any agent whether it is infectious versus noninfectious or contagious versus noncontagious. The solutions vary. The experience of others presented with similar situations may be especially helpful. Because of their nature, outbreaks are difficult to prepare for. When faced with a potential outbreak, the best strategy is to approach it scientifically, systematically, and with an open mind.

Animals↗

Electrospray ionization-Fourier transform ion cyclotron mass spectrometry using ion preselection and external accumulation for ultrahigh sensitivity.

The dynamic range of Fourier transform ion cyclotron mass spectrometry (FTICR) is typically limited by the useful charge capacity of an FTICR cell (to approximately 10(6) to 10(7) elementary charges) and the minimum number of ions required to produce a useful signal (approximately 10(2) elementary charges). We show that the expansion of the dynamic range by 2 orders of magnitude can be achieved by preselecting lower abundance species in a quadrupole interface to an electrospray ionization (ESI) source. Ion preselection is then followed by ion accumulation in external to the FTICR cell a linear (2-D) quadrupole trap and subsequent transfer to the region of high magnetic field for gated trapping in the FTICR cell. Two modes of ion preselection, using either the quadrupole filtering mode or rf-only dipolar excitation, were studied and mass resolutions of 30 to 100 were achieved for selective external ion accumulation of peptides and proteins with molecular weights ranging from 500 to 17,000 Da. The ability to selectively eject the most abundant species before trapping in the FTICR has enormous practical benefits for increasing the sensitivity and dynamic range of measurements.

Algorithms↗

Physical/chemical separations in the break-up of highly charged droplets from electrosprays.

Highly-charged droplets, as formed by an electrospray process, are known to undergo asymmetric fission to form smaller droplets. We have observed a chemical and physical separation phenomenon that occurs in the droplet break-up process and is related to a compound's surface activity in solution. Two experimental approaches demonstrated that the smaller satellite droplets and the progeny droplets generated by the spray formation and asymmetric fission processes to be surfactant-enriched. These smaller droplets were also effectively separated from the larger primary and residual droplets because of their smaller inertia and high surface charge density, and a region attributed to the initially formed smaller satellite droplets was found to be strikingly confined in a narrow periphery region of the electrospray. The phenomenon may have utility for chemical separations and have significant implications for the sensitivity and selectivity of electrospray ionization-mass spectrometry.

Journal Article↗

A dynamic ion cooling technique for FTICR mass spectrometry.

A fast dynamic ion cooling technique based upon the adiabatic invariant phenomenon for Fourier transform ion cyclotron resonance mass spectrometry (FTICR) is presented. The method cools ions in the FTICR trap more efficiently, within a few hundred milliseconds without the use of a buffer gas, and results in a substantial signal enhancement. All performance aspects of the FTICR spectrum, e.g., peak intensities, mass resolution, and mass accuracy, improve significantly compared with cooling based on ion-ion interactions. The method may be useful in biological applications of FTICR, such as in proteomic studies involving extended on-line liquid chromatography (LC) separations, in which both the duty cycle and mass accuracy are crucially important.

Algorithms↗