Fast estimation of arterial vascular parameters for transient and steady beats with application to hemodynamic state under variant gravitational conditions.

Numerous parameter estimation techniques exist for characterizing the arterial system using electrical circuit analogs. These techniques are often limited by requiring steady-state beat conditions and can be computationally expensive. Therefore, a new method was developed to estimate arterial parameters during steady and transient beat conditions. A four-element electrical analog circuit was used to model the arterial system. The input impedance equations for this model were derived and reduced to their real and imaginary components. Next, the physiological input impedance was calculated by computing fast Fourier transforms of physiological aortic pressure (AoP) and aortic flow. The approach was to reduce the error between the calculated model impedance and the physiological arterial impedance using a Jacobian matrix technique which iteratively adjusted arterial parameter values. This technique also included algorithms for estimating physiological arterial parameters for nonsteady physiological AoP beats. The method was insensitive to initial parameter estimates and to small errors in the physiological impedance coefficients. When the estimation technique was applied to in vivo data containing steady and transient beats it reliably estimated Windkessel arterial parameters under a wide range of physiological conditions. Further, this method appears to be more computationally efficient compared to time-domain approaches.

Animals↗

A conscious baboon model for evaluation of hemodynamics in altered gravity.

A model was developed for evaluation of cardiovascular parameters in conscious baboons exposed to altered gravitational environments. Baboons were trained to sit quietly in a confinement chair of unique design which allowed a range of normal physical activity. They were then instrumented with high-fidelity blood pressure transducers in the aorta and left ventricle, electromagnetic flow probes encircling the proximal ascending aorta, left and right atrial fluid catheters, left ventricular sonomicrometer crystals in a 3-axis configuration, and a hydraulic occluder cuff encircling the inferior vena cava. Catheters and transducer wires were exteriorized at the midscapular region of the back. Viability of percutaneous exit sites was enhanced by use of velour cuffs on the transducer wires, providing a scaffold for wound healing. Pressure transducers and flow probes were calibrated and balanced during postoperative cardiac catheterization procedures. This instrumentation allowed measurement of beat-to-beat stroke volume and cardiac output not reliant on thermodilution techniques. Postoperative longevity was from 1 to 10 months. Instrumentation failure included endocardial trapping of ventricular pressure transducers, corrosion of ventricular sonomicrometer crystals, and catheter tip thrombosis. Acquisition of high quality data was possible with this model in several different environments of altered gravitational stress, allowing characterization of aortic flow and ventricular performance.

Animals↗

A method for repeated high-fidelity micromanometer measurement of intracardiac pressures.

Dial-tipped, high-fidelity micromanometers were inserted through polyurethane catheters to acutely measure blood pressures within the chambers of the heart and the great vessels of baboons, rhesus monkeys, and goats. Repeated measurements of atrial, ventricular, aortic, and pulmonary artery pressure were possible with this method, with calibration of micromanometers accomplished immediately prior to and after pressure recordings to assure data accuracy. All attempts to pass micromanometers into the atria in all species were successful. Passage of micromanometers from the left ventricle across the aortic valve and into the aorta was successful in 97% of the attempts in baboons, 100% for rhesus monkeys, and 75% for goats; while insertions into the pulmonary artery from the right ventricle were successful in 64% of the baboons, 40% of the rhesus monkeys, and 75% of the goats. Advantages of this technique are that a permanent conduit for cardiac vascular access is available and that high-fidelity pressure signals may be acquired.

Animals↗