Effects of diuretic therapy and exercise-related arrhythmias in systemic hypertension.

The effect of aerobic exercise on cardiac arrhythmias, plasma catecholamines, potassium and magnesium in patients with systemic hypertension was assessed. Twenty patients (age 54 +/- 8 years) with uncomplicated hypertension underwent exercise treadmill testing twice while receiving placebo and twice while receiving hydrochlorothiazide 100 mg daily. Blood samples for electrolytes and catecholamines were obtained at rest, at peak exercise and 10 minutes after exercise. There were no substantial differences comparing the first to the second placebo phase or the first to the second treatment period. As expected, hydrochlorothiazide treatment caused a significant decrease in serum potassium (4.00 +/- 0.44 to 3.32 +/- 0.49 mEq/liter, p less than 0.001). Serum magnesium did not change with treatment. Serum potassium, serum magnesium and plasma catecholamines increased significantly with exercise. No rebound hypokalemia occurred during recovery. Occasional ventricular premature contractions were noted at rest during all phases of the study, with only a slight increase in frequency during exercise. Couplets were noted only rarely. No difference in the frequency or complexity of arrhythmias was noted between placebo and treatment periods. Diuretic therapy or diuretic-induced hypokalemia has no profound effect on cardiac arrhythmias during or after exercise in patients with uncomplicated systemic hypertension.

Blood Pressure↗

Transdiaphragmatic implantation of the automatic implantable cardioverter defibrillator.

A new surgical approach for implantation of the automatic implantable cardioverter defibrillator without thoracotomy was used in 12 patients, aged 46 to 72 years. Preimplantation arrhythmia was ventricular tachycardia in 7 patients and ventricular fibrillation in 5 patients. The mean ejection fraction was 19%. Six patients were at high risk for general anesthesia for a variety of medical problems, and 2 patients had had a previous cardiac operation. Epidural anesthesia was used in 8 patients without intubation. The surgical approach used a longitudinal epigastric extraperitoneal incision with access to the heart through an incision made in the central tendon of the diaphragm. Two patches and two epicardial sensing leads were placed in all patients. All patients but one could be defibrillated with 20 J or less. There was no operative mortality and minimal morbidity. There were two late deaths due to heart failure. Thus, the transdiaphragmatic approach provides an excellent exposure for automatic implantable cardioverter defibrillator implantation, avoids general anesthesia and thoracotomy, and can be used after a previous cardiac operation.

Aged↗

Sotalol for refractory sustained ventricular tachycardia and nonfatal cardiac arrest.

The efficacy and safety of sotalol were assessed by electrophysiologic testing and ambulatory recordings in 16 patients with recurrent sustained ventricular tachycardia (VT) or nonfatal cardiac arrest who were refractory to an average of 4.8 conventional antiarrhythmic agents. Twenty-four-hour ambulatory recordings were performed before and after sotalol therapy. Fourteen patients underwent baseline electrophysiologic study and sustained VT was inducible in 12. Oral sotalol (320 to 960 mg/day) completely suppressed inducible sustained VT in 7 patients (58%), with modification in 3 (25%). Ventricular premature complexes were suppressed from baseline (mean +/- standard deviation) 431 +/- 616 to 60 +/- 110/hr (p less than 0.03). After a mean follow-up of 19 +/- 7 months, 12 of 14 patients receiving sotalol treatment had successful suppression of ventricular premature complexes (60 +/- 85/hr) and remained clinically free of sustained VT, except 2 who needed additional antiarrhythmic drugs to suppress the recurrent sustained VT. One patient died suddenly after 25 months of sotalol treatment. No severe side effects were noted during sotalol therapy. This study demonstrates that sotalol is a well-tolerated, effective antiarrhythmic agent in patients at high-risk for sudden death. It appears to be beneficial in patients who did not benefit from multiple drug treatment.

Adult↗

Serial electrocardiographic changes in idiopathic dilated cardiomyopathy confirmed at necropsy.

Serial electrocardiographic changes in necropsy-proven idiopathic dilated cardiomyopathy are evaluated and a method of predicting heart weight using QRS amplitudes is described. In 34 patients with multiple electrocardiograms (mean 3/patient) progressive prolongation of PR interval (0.18 +/- 0.03 to 0.21 +/- 0.03, p less than 0.001) and QRS duration (0.10 +/- 0.02 to 0.13 +/- 0.03, p less than 0.0001) was noted. Progressive conduction abnormalities were common (82%). QTc interval and QRS- and T-wave axes did not change. In 50 patients with electrocardiograms within 60 days of death, total 12-lead QRS and V1 through V6 QRS amplitude correlated better with heart weight (r = 0.51, p less than 0.0001 and r = 0.55, p less than 0.0001) than the Estes-Romhilt score did. The mean total 12-lead QRS amplitude was 138 mm with a mean of 106 for V1 through V6. In 31 patients cardiac mass index was calculated and showed significant correlation with 12-lead and V1 through V6 QRS amplitudes (r = 0.68, p less than 0.0001 and r = 0.75, p less than 0.0001, respectively). The QRS amplitudes remained constant during the illness. By using total 12-lead QRS or frontal plane QRS amplitude, heart weight can be predicted as early as 2 years before death. Use of body surface area and QRS amplitude criteria increases the accuracy of heart weight prediction. Thus, progressive electrocardiographic changes are common in patients with idiopathic dilated cardiomyopathy and QRS amplitude criteria are more accurate in the prediction of left ventricular hypertrophy than standard criteria.

Adolescent↗

M-mode echocardiograms for determination of optimal left atrial timing in patients with dual chamber pacemakers.

To determine if the A wave of the mitral valve echocardiogram can be used as a marker for left atrial (LA) activity and assist in the programming of dual chamber pacemakers, 156 echocardiograms with the mitral A wave present were obtained from 23 patients with dual chamber pacemakers, all of whom had bipolar esophageal recordings of LA depolarization. Twelve of these patients also underwent hemodynamic study with cardiac function determined at 5 different pacemaker settings: ventricular demand pacing and dual chamber sequential pacing at 0 or 25, 150, 200 and 250 ms programming atrioventricular (AV) delay. The time delay from right atrial pacing artifact to onset and peak of mitral A wave was linearly related to the time from atrial pacing artifact to LA depolarization on the esophageal lead (p less than 0.001). As pacing mode changed from dual chamber sequential pacing (DVI) mode to atrial synchronous-ventricular pacing (VDD), the A wave came earlier relative to the ventricular pacing spike, linearly related to the LA to ventricular extension with mode change determined with the esophageal lead (r = 0.94, p less than 0.001). The time from atrial pacing to peak of A wave was shorter in patients whose optimal programmed AV delay was 150 ms compared with those whose optimal AV delay was 200 or 250 ms (p less than 0.02). At the optimal programmed delay for cardiac output, the peak of the A wave was an average of 13 +/- 36 ms after the ventricular pacing spike.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

The use and interaction of permanent pacemakers and the automatic implantable cardioverter defibrillator.

The adverse interactions of permanent pacemakers and automatic implantable cardioverter defibrillators (AICD) were studied in nine patients in whom both devices were implanted. Both unipolar and bipolar pacemakers were evaluated. The permanent pacemakers were also used to do noninvasive electrophysiological studies and to induce ventricular fibrillation. Undersensing of ventricular fibrillation by the permanent pacemakers caused inappropriate pacemaker stimuli, which caused undersensing of ventricular fibrillation by the AICD in three of four patients with unipolar pacemakers. After an AICD discharge, pacemaker noncapture was seen in eight of 22 episodes for an average 4.9 seconds and inability to sense was seen in 11 of 20 episodes for an average 9.0 seconds. Counting of pacemaker stimuli and QRS by the AICD caused inappropriate discharges. Noninvasive electrophysiological testing by the pacemakers correlated with invasive testing. Furthermore, induction of ventricular fibrillation was successful in four of five patients attempted, though requiring long bursts at high outputs at the shortest cycle lengths obtainable by these pacemakers. Operation of the AICD and permanent pacemakers must be clearly understood to avoid adverse interactions of these devices.

Electric Countershock↗

Thiazide therapy is not a cause of arrhythmia in patients with systemic hypertension.

Forty-four patients with uncomplicated systemic hypertension underwent 48-hour electrocardiographic monitoring before and after four weeks of treatment with hydrochlorothiazide, 100 mg daily. Plasma potassium concentration decreased from 4.07 +/- 0.26 mmol/L (4.07 +/- 0.26 mEq/L) to 3.36 +/- 0.44 mmol/L (3.36 +/- 0.44 mEq/L). The average number of premature ventricular contractions, couplets, or ventricular tachycardia episodes did not change significantly. Twenty patients had more than minimal ventricular ectopy (class 2 to 5) before and 17 after diuretic therapy. Further analysis revealed that following diuretic therapy, neither patients with plasma potassium levels of 3.4 mmol/L or less (less than or equal to 3.4 mEq/L) nor patients with left ventricular hypertrophy had increased ectopy as compared with baseline. At baseline, patients with left ventricular hypertrophy had more arrhythmias than patients without. We conclude that the results of this study provide no evidence that diuretic therapy or diuretic-induced hypokalemia results in increased ventricular ectopy, and that patients with left ventricular hypertrophy may have more ventricular ectopy than patients without, but these arrhythmias are not adversely effected by diuretic therapy.

Cardiac Complexes, Premature↗

Importance of left atrial timing in the programming of dual-chamber pacemakers.

To determine the hemodynamic effect of different programmed atrioventricular (AV) delays and the importance of the actual timing of left atrial (LA) depolarization, 16 patients with dual-chamber pacemakers were studied and all were found to have an optimal programmed AV delay for cardiac function. However, randomly chosen AV delays of 150, 200 or 250 ms actually provided worse stroke volume than VVI pacing in 7 patients. The optimal programmed AV delay was variable between patients and was related to the interatrial conduction delay, measured as the time from right atrial pacing artifact to LA depolarization (mean 144 +/- 82 ms, range 70 to 380.) Patients with short interatrial delays (less than or equal to 90 ms) were served better by shorter programmed AV delays (150 ms), and patients with longer interatrial delays (greater than or equal to 120 ms) were served better by longer programmed AV delays (greater than or equal to 200 ms) (p less than 0.05). Furthermore, as pacing mode changed from dual-chamber sequential pacing (DVI) to atrial synchronous ventricular pacing (VDD), the LA to ventricular sequence increased from 6 +/- 81 ms to 137 +/- 50 ms (p less than 0.001). This change in the LA to ventricular sequence with mode change produced a significant decrease in stroke volume (p less than 0.05). Thus, the optimal programmed AV delay in patients with dual-chamber pacemakers is predicted by the relation of LA and ventricular activation. Because interatrial conduction delays vary widely, optimal programming requires knowledge of the LA to ventricular sequence.(ABSTRACT TRUNCATED AT 250 WORDS)

Atrioventricular Node↗

Noninvasive electrophysiologic study using standard permanent pacemakers in patients with spontaneous sustained ventricular tachycardia or ventricular fibrillation.

Permanent pacemakers capable of noninvasive electrophysiologic testing were used to study and treat 26 patients with spontaneous sustained ventricular tachycardia (VT) or fibrillation (VF). One hundred nine episodes of sustained VT or VF were induced in these patients. In 8 patients spontaneous VT was reverted by noninvasive means. Drug changes based on noninvasive testing were made in 12 patients. In the 1- to 67-month follow-up period, drug therapy based on noninvasive electrophysiologic testing was predictive of outcome in patients with spontaneous arrhythmias. Thus, noninvasive electrophysiologic testing using permanent pacemakers is a useful method for studying and treating patients with recurrent sustained ventricular arrhythmias.

Cardiac Pacing, Artificial↗

The NASPE/BPEG generic pacemaker code for antibradyarrhythmia and adaptive-rate pacing and antitachyarrhythmia devices.

A new generic pacemaker code, derived from and compatible with the Revised ICHD Code, was proposed jointly by the North American Society of Pacing and Electrophysiology (NASPE) Mode Code Committee and the British Pacing and Electrophysiology Group (BPEG), and has been adopted by the NASPE Board of Trustees. It is abbreviated as the NBG (for "NASPE/BPEG Generic") Code, and was developed to permit extension of the generic-code concept to pacemakers whose escape rate is continuously controlled by monitoring some physiologic variable, rather than determined by fixed escape intervals measured from stimuli or sensed depolarizations, and to antitachyarrhythmia devices including cardioverters and defibrillators. The NASPE/BPEG Code incorporates an "R" in the fourth position to signify rate modulation (adaptive-rate pacing), and one of four letters in the fifth position to indicate the presence of antitachyarrhythmia-pacing capability or of cardioversion or defibrillation functions.

Bradycardia↗

Viadent, ethanol, and pH effects upon gingival epithelial-like cells, in vitro.

Interest has recently been directed towards the use of antiplaque mouthrinses. Most published material concerns the antimicrobial effects of these agents rather than their effects upon oral tissue. This study was conducted to evaluate the effect of a sanguinarine-containing mouthrinse called Viadent upon epithelial-like gingival cells. The cells were grown for 24 hours in supplemented Earle's medium, with and without different Viadent dilutions. Cell counts were made with a hematocytometer. It was found that 50% of the cells were inhibited at 1.2% Viadent. In similar studies, it was found that 70% ethanol and two pH buffers were less toxic than Viadent. Exposure of preformed cell monolayers to Viadent also showed significant inhibition. The relative toxicity of different antiplaque agents may be compared using such cells as a model system. In conclusion, it was observed that Viadent significantly affected gingival cell growth in vitro, that viable cell numbers were greatly reduced by short time exposure, and that the toxic effect of Viadent could only partially be accounted for by ethanol content and/or pH.

Adult↗

A review of the effects of disopyramide phosphate on left ventricular function and the peripheral circulation.

In the absence of preexistent myocardial dysfunction, the risk of producing cardiac decompensation in patients being treated with any of the conventional antiarrhythmic agents is low. The availability of disopyramide for clinical use in 1977 produced optimism for an effective antiarrhythmic agent that was free of the well-known immediate and late toxicities of quinidine and procainamide. Unfortunately, shortly after its clinical introduction, reports appeared that raised concern about the negative inotropic actions of disopyramide and the possible role of this drug in precipitating heart failure. In clinical use, the frequency of adverse effects on ventricular function appeared to be out of proportion to disopyramide's greater negative inotropic activity and the contrasting (augmenting) effect on the peripheral vascular resistance compared to that of either quinidine or procainamide, suggesting that the other factors contributed to these observations. Review of the reported literature reveals that certain factors encourage such adverse reactions. These primarily include the routine use of oral and especially intravenous loading dosages of disopyramide in an effort to attain rapid onset of action, the failure to adequately reduce dosages of disopyramide in the setting of compromised renal function, and, most importantly, the use of standard (and even loading) dosages in patients with active heart failure, compromised left ventricular function, or a history of heart failure. The avoidance of loading dosages of disopyramide, adequate reductions of maintenance dosages in the setting of renal insufficiency, gradual dose titration for additional drug action, and omission of patients with decompensated heart failure or significant left ventricular dysfunction should significantly enhance safety in the use of disopyramide.

Anti-Arrhythmia Agents↗

Noninvasive detection of coronary artery patency using continuous ST-segment monitoring.

Continuous ST-segment Holter recordings were analyzed from 46 patients with acute myocardial infarction (AMI) receiving intracoronary streptokinase (SK) during the first 48 hours of hospitalization. Changes in ST deviation and the time periods of these changes were quantitated and correlated with angiographic evidence of reperfusion. Thirty-six patients had total occlusion of the infarct vessel and 10 had subtotal occlusion. Of the 36 vessels that were totally occluded, 19 were reperfused and 17 were not. In patients in whom reperfusion was successful, an ST steady state was achieved 55 +/- 32 minutes after SK administration. In patients in whom it was not successful, a steady state was achieved in 219 +/- 141 minutes (p less than 0.001). Achievement of steady state within 100 minutes after SK reperfusion indicated successful reperfusion with 89% sensitivity and 82% specificity. All patients with subtotal occlusion achieved an ST steady state before SK infusion. No patient with total occlusion achieved a steady state before SK. Achievement of ST steady state before SK infusion was 100% sensitive and 100% specific for subtotal occlusion at initial angiography. Continuous, quantitative ST-segment analysis is a sensitive and specific noninvasive technique for following coronary artery patency during AMI.

Coronary Vessels↗

Ventricular arrhythmias during reperfusion.

Accelerated idioventricular rhythm has been used as a marker for coronary reperfusion. The incidence of accelerated idioventricular rhythm and ventricular tachycardia was evaluated in 52 consecutive patients undergoing thrombolysis with intracoronary streptokinase during acute myocardial infarction. Complete 12-hour Holter recordings during and after intracoronary streptokinase were obtained in 39 patients. Reperfusion was documented in 17 patients (44%), no reperfusion in 14 (36%), and subtotal occlusion in eight (20%). Accelerated idioventricular rhythm occurred in 83%, 57%, and 63% of patients by group, respectively (p greater than 0.05). Ventricular tachycardia occurred in 100%, 71%, and 100% of patients by group, respectively (p less than 0.05). These data demonstrate that accelerated idioventricular rhythm is not specific for reperfusion and cannot be used as a marker for this event, and that ventricular tachycardia is more common with reperfusion and subtotal occlusion.

Cardiac Catheterization↗

Thermal effects of laser and electrical discharge on cardiovascular tissue: implications for coronary artery recanalization and endocardial ablation.

To determine the thermal responses of cardiovascular tissues to laser and electrical ablation, and to characterize the effects of different superfusing media and temperatures on target tissue temperatures and resulting extent of tissue injury, 184 laser and 15 electrical discharges were delivered to segments of human and canine aorta and canine ventricular endocardium. Tissue temperatures were measured 2 mm from the point of contact of laser fiber tip and tissue. When superfusing media consisted of whole blood or plasma at room temperature, a standard 40 J laser discharge caused peak arterial temperatures to rise 29.2 +/- 1.6 degrees C and 30 +/- 1.4 degrees C, respectively; however, tissue cooling was significantly slower in blood than in plasma. When saline solution was superfused, tissue temperatures rose by 11.4 +/- 2.2 degrees C, and tissue cooling occurred significantly faster than with either plasma or blood. The dimensions of the resulting aortic lesions were larger when blood (1.69 +/- 0.26 mm) was superfused than when plasma (1.39 +/- 0.04 mm) or saline (0.77 +/- 0.13 mm) was superfused (p less than 0.0001). Similar findings were observed with ventricular endocardium using blood or saline as the superfusing medium. In arterial tissue, superfusion with cold blood or saline solution resulted in lower peak temperature elevations (22 +/- 3.8 degrees C and 13.5 +/- 1.3 degrees C, respectively) and faster tissue cooling after laser discharge. Corresponding aortic lesion sizes were significantly smaller (1.4 +/- 0.03 and 0.5 +/- 0.02 mm, respectively) than when blood or saline medium was superfused at room temperature (p less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

A new advancement in noninvasive electrophysiology: a standard laboratory stimulator pulse coupled with an implanted pacemaker.

A new device for coupling the pulse from a standard laboratory stimulator to commercially available implanted pacemakers for use in noninvasive electrophysiology testing has been developed. When programmed to an electrophysiology mode, a 37 kHz carrier wave, generated by the programmer, maintains communication with the implanted pacemaker. Stimuli generated from a standard lab stimulator cause a break in the carrier wave and an output from the pacemaker. Cycle lengths as short as 127 msec can be attained. In addition to standard electrophysiology testing, this noninvasive electrophysiological technique can be used to fibrillate the heart to test the efficacy of automatic implantable cardioverter/defibrillators.

Electric Stimulation↗

Pacemaker treatment of cardiac arrhythmia.

The role of pacing for arrhythmias will inevitably increase, both temporarily until a patient can be controlled with drug therapy and permanently in those cases in which drug therapy fails. While "ideal" antiarrhythmic drugs will continue to be sought, "ideal" pacing therapies will be developed. Inevitably the average patient with severe arrhythmia will benefit from a synergistic use of both modalities. The methods for capture, techniques to ensure success, standard and advanced pacing sequences, and specific indications will become as much a part of the armamentarium of the front-line clinician controlling the initial potentially lethal episodes as it has for the experienced electrophysiologist.

Arrhythmias, Cardiac↗