Search PubMed⌕ Search

Biomedical subjects

R C Gomez

Publications and source records attributed to R C Gomez.

8 recordsLinked to original sources

Ventricular assist device use with mechanical heart valves: an outcome series and literature review.

BACKGROUND: Management of postcardiotomy cardiogenic shock with a ventricular assist device (VAD) is a common and accepted therapeutic option. However, VAD use in patients with mechanical heart valves (MHVs) is thought to carry an increased risk of thromboembolus. We report a series of 7 patients with combined VAD-MHV and review the literature. METHODS: A retrospective review was performed on all patients who were supported with a ventricular assist device with a mechanical heart valve in place. A literature review was also performed from 1966 to 2000. RESULTS: Seven patients were identified from April 1988 to June 2000 as having VAD support with a MHV. One thromboembolic event was documented in the 7 patients (14%). Five of the 7 patients (71%) underwent VAD explantation. Overall survival rate was 3 of 7 (43%). Causes of death included heart failure, renal failure, multisystem organ failure, adult respiratory distress syndrome, and cerebral hypoxia. All patients who died had support withdrawn at the request of the family. All patients discharged are currently alive with length of survival of 3, 26, and 84 months. CONCLUSIONS: This study suggests that this population's rate of survival to discharge and risk of thromboembolus compare favorably to that of the general VAD population. We believe that anticoagulation can be managed as with any MHV patient and that flow rates can be kept slightly lower, which may encourage valve washing.

Aged↗

Intracranial bleed during bridge to transplant may not preclude a successful result.

We report the case of a 29-year-old man who suffered sub-arachnoid bleeding while stabilized on a biventricular assist device as a bridge to cardiac transplantation. We adjusted his anti-coagulation therapy to control the bleeding and to concurrently minimize thrombosis while on support. He underwent 2 craniotomy operations to evacuate sub-arachnoid hematomas, and he underwent a subsequent operation to debride and close the dura. Eighteen days later, he underwent successful orthotopic heart transplant and was discharged to home 3 weeks post-transplant.

Adult↗

Bridge to recovery for postcardiotomy failure: is there still a role for centrifugal pumps?

BACKGROUND: Early implantation of centrifugal devices in patients with postcardiotomy cardiogenic shock may provide a bridge to recovery and allow subsequent long-term survival. METHODS: Since January 1989, 62 patients were supported with centrifugal pumps because of failure to wean from cardiopulmonary bypass. Indications were postcardiotomy cardiogenic shock (PCCS) (n = 60), bridge to cardiac retransplantation (n = 1), and right ventricular failure (n = 1). Patients' ages ranged from 23 to 78 years; 40 were men (65%), and 22 were women (35%). Twenty-two patients (35%) had a left ventricular assist device; 9 patients (15%) had a right ventricular assist device; and 31 patients (50%) had a biventricular assist device. Length of support ranged from 1 day to 19 days. RESULTS: Forty-two patients (68%) were weaned successfully; 27 patients survived to discharge (44%). Complications included bleeding (n = 41, 66%), renal failure (n = 28, 45%), and respiratory failure (n = 26, 42%). Currently, 23 patients survived 10 or more years (n = 1), 6 to 10 years (n = 7), 1 to 5 years (n = 10), and less than 1 year (n = 5). CONCLUSIONS: Centrifugal pumps are available, easy to use, and relatively inexpensive. Our experience justifies their continued use as a bridge to recovery for patients with postcardiotomy cardiogenic shock, despite the availability and increasing use of more expensive devices.

Adult↗

Prolonged ventricular support using a centrifugal pump.

The Biomedicus centrifugal pump was required to provide prolonged ventricular support to 13 patients with hemodynamic instability: 11 after cardiovascular surgical procedures, 1 after myocardial infarction and 1 after failure of a heart transplant. The duration of support ranged from 3.5 hours to 9 days (mean 72 hours). Complications included bleeding in six patients, renal insufficiency in three and central nervous system deficit in three. Six patients (46%) were successfully weaned from the pump. The patient with graft failure had hyperacute rejection of a second heart. Five patients were discharged from the hospital. There was one death 8 months postoperatively. Prolonged ventricular support with the centrifugal pump may allow recovery of potentially reversible ventricular dysfunction in selected patients after cardiac surgical procedures.

Adolescent↗

Concomitant vascular procedures in conjunction with myocardial revascularization: all or none? A report of a case.

Patients with coronary artery atherosclerosis usually have concomitant peripheral vascular lesions. The authors describe the case of a 65-year-old woman who had multiple symptomatic lesions: severe stenosis of the left main coronary artery and the carotid arteries, a large abdominal aortic aneurysm and bilateral renal artery occlusion. To manage these and to avoid myocardial infarction and cerebrovascular accident at operation, concomitant procedures were performed as follows: coronary artery bypass grafting, aneurysm resection, carotid endarterectomy and revascularization of the larger kidney. Although the patient's hospital stay was prolonged, there was no major morbidity and her recovery was good. She returned to a normal life-style, requiring only hemodialysis on an outpatient basis.

Aged↗

Neonatal tetanus.

Explore the source record for details and available documents.