Search PubMed⌕ Search

Biomedical subjects

R Byrne

Publications and source records attributed to R Byrne.

42 records · Page 3Linked to original sources

Criteria for obtaining and interpreting breast thermagrams.

The thermal and graphic criteria which should be used to evaluate breast thermograms are outlined. Thermograms are then categorized as normal, suspicious, or abnormal on the basis of the criteria outlined. It is hoped that these criteria can be used widely to standardize breast thermographic evaluation.

Breast Neoplasms↗

Comparative physiological disposition of two nitrofuran anti-microbial agents.

The physiological disposition of two nitrofuran derivatives used as antimicrobial agents for the treatment of acute infectious diarrhoea was evaluated in humans and animals. Upon administration of a single oral dose (600 mg) of nifurzide or nifuroxazide, no unchanged parent drug was detected in human blood or urine. In rats given 14C-nifurzide and 14C-nifuroxazide at a dose of 10 mg kg-1, 5 per cent and 17 per cent of the dose of nifurzide and nifuroxazide, respectively, were excreted in urine over a 48-hour period. None of this radioactivity was present as unchanged drug, indicating that renal excretion of both drugs occurs as metabolites. In the faeces 20 per cent of the radioactivity recovered was associated with unchanged nifuroxazide as compared with 100 per cent for nifurzide. Whole body autoradiography using rats showed that after oral administration of 14C-nifurzide and 14C-nifuroxazide, most of the radioactivity remained in the gastrointestinal lumen.

Adult↗

Improved serologic detection of hepatitis C virus with a paramagnetic microparticle assay using multiple antigenic sequences.

A paramagnetic microparticle (MP) assay for antibody to hepatitis C virus (anti-HCV) was developed, in which the probe for antibody consisted of synthetic peptides corresponding to HCV capsid and nonstructural c-100 regions, as well as a recombinant protein corresponding to the nonstructural c33c region. Assay performance was evaluated by testing serum from 108 geographically diverse patients with non-A, non-B hepatitis (NANBH). The frequency of anti-HCV reactivity detected with the MP assay and with an enzyme-linked immunosorbent assay (ELISA) for c-100 was 91 and 70 percent, respectively. All c-100 HCV ELISA-reactive specimens also reacted on the MP assay. In addition, anti-HCV seroconversion in three plasma donors was detected one to two blood collection dates earlier by the MP assay than by the c-100 HCV ELISA and at similar blood collection dates by the MP assay and a second-generation anti-HCV ELISA. Serologic responses to the three distinct antigenic regions of HCV in NANBH patients varied: reactivity to all three antigens was most common (49%), reactivity to both capsid and c33c (40%) was next most common, and single-antigen reactivity was rare (4%). MP assay reactivity of 825 volunteer donors was 0.1 percent. These results demonstrate both the utility of additional HCV antigens for an effective anti-HCV screening assay and the application of paramagnetic MP technology to serologic testing for HCV infection.

Antibody Specificity↗