Search PubMed⌕ Search

Biomedical subjects

R Bunce

Publications and source records attributed to R Bunce.

5 recordsLinked to original sources

A simple near-patient test for nicotine and its metabolites in urine to assess smoking habit.

We describe a disposable, near-patient urine test to monitor cigarette smoking. A plastic device contains the sealed dried reagents to measure nicotine and its metabolites, by a colorimetric assay. The device can be used to give a qualitative assessment of tobacco consumption, simply by observing a colour change. Alternatively, the test can be quantified by measuring the light absorbance with a simple colorimeter, and a concentration of nicotinic metabolites obtained with reference to a cotinine standard. A correction factor for the concentration of the urine sample, based on light absorbance, allows the result to be expressed as a ratio to urine concentration. This method correlates with reported daily cigarette consumption (r = 0.69, p < 0.0001) and compares favourably with cotinine, as measured by gas chromatography (r = 0.89, p < 0.0001). The method provides a simple-to-use, inexpensive way to monitoring tobacco consumption in extralaboratory situations.

Chromatography, Gas↗

A portable silicon photodiode luminometer.

A simple, inexpensive, battery-powered, portable luminometer which is based on a silicon photodiode is described. The instrument is intended to measure the light produced by chemiluminescent and bioluminescent reactions. The device shows a good detection limit and, in a bioluminescent reaction for adenosine 5'-triphosphate (ATP), detected 0.5 pmol in 1 ml of aqueous solution. The instrument measures irradiance from 10(-13) to 10(-11) W cm-2 at the sensor, within the range 300 to 900 nm.

Adenosine Triphosphate↗

Histidine decarboxylase activity in trauma-resistant rats.

Studies have been carried out to determine the possible role of nascent histamine in the development of traumatic shock. This was done by examining histidine decarboxylase (HD) activity of the lung, spleen, and plasma following exposure to trauma in normal and trauma-resistant rats. In normal rats, there was a significant increase in lung HD activity at 15 min and 4 h; and in the spleen the HD activity increased significantly at 4 h. In trauma-resistant rats exposed to trauma, there were no changes in enzyme activity in the lung and less pronounced changes in the spleen. The plasma HD activity remained stable in normal and resistant rats following episodes of trauma. Changes in total erythrocyte hemoglobin were observed in both normal and trauma-adapted rats following exposure to this stress, increasing significantly in normal rats, but decreasing in trauma-resistant rats. Blood volume decreased significantly at 4 h after trauma in normal animals; whereas only a slight decrease was noted in resistant animals. The data support the concept that newly formed histamine contributes to the pathogenesis of shock. It is also proposed that the increased resistance, characteristic of trauma-adapted rats, could be partly due to an inhibition of enzyme activation following trauma.

Animals↗