Search PubMed⌕ Search

Biomedical subjects

R Birngruber

Publications and source records attributed to R Birngruber.

At least 91 records · Page 5Linked to original sources

Transscleral and indirect ophthalmoscope diode laser retinal photocoagulation: experimental quantification of the therapeutic range for their application in the treatment of retinopathy of prematurity.

Laser indirect ophthalmoscope (LIO) photocoagulation and transscleral photocoagulation through the conjunctiva and subconjunctiva were performed in the fundus of chinchilla gray rabbits using various exposure times and powers, and the thresholds for retinal blanching and choroidal hemorrhage were determined. The therapeutic range was described for both applications as the ratio between energy values to produce grayish white lesions and hemorrhage at 50% probability. The therapeutic range appeared to remain almost constant with different exposure times. The mean ratio with LIO was 3.2 +/- 0.28, similar to that with slit-lamp delivery reported in our previous study. The mean ratio with transscleral photocoagulation through the conjunctiva and subconjunctiva were 2.48 +/- 0.28 and 2.38 +/- 0.26, respectively. The variability of LIO appeared to be a little lower than with transscleral photocoagulation. There was no significant difference between the variability with transscleral photocoagulation through the conjunctiva and subconjunctiva.

Animals↗

Relaxation of vascular smooth muscle induced by low-power laser radiation.

The relaxation of rabbit aorta rings induced by low-power laser radiation was investigated in vitro to determine the location of the chromophore(s) responsible for this response and evaluate possible mechanisms. An action spectrum for relaxation was measured on rabbit thoracic aorta rings precontracted with norepinephrine. The decrease in isometric tension was measured during exposure to laser light (351-625 nm) delivered via a fiber optic to a small spot on the adventitial surface. The shortest UV wavelength (351 nm) was 35-fold more effective than 390 nm and 1700-fold more effective than 460 nm. Ultraviolet wavelengths also produced greater maximum relaxation (0.40-0.45) than visible wavelengths (0.20-0.25), suggesting that photovasorelaxation involves more than one chromophore. The adventitial layer was not necessary for photovasorelaxation, indicating that the light is absorbed by a chromophore in the medial layer. The same degree of relaxation was obtained on rings without adventitia when either one-half of the ring, or a small spot was irradiated indicating that communication between smooth muscle cells spreads a signal from the area illuminated to the entire ring. The mechanism for photovasorelaxation was investigated using potential inhibitors. N-monomethyl-L-arginine and N-amino-L-arginine, inhibitors of nitric oxide synthase, did not alter photovasorelaxation nor did indomethacin, an inhibitor of cyclooxygenase, and zinc protoporphyrin, an inhibitor of heme oxygenase.

Animals↗

[Histology of retinal lesions after continuous irradiation and selective micro-coagulation of the retinal pigment epithelium].

Mild continuous wave (CW) irradiation (100 ms, 20 mW, 514 nm) and irradiation with 100 repetitive 5 microseconds laser pulses (3 or 6 microJ, 514 nm) at a repetition rate of 500 Hz was performed to the regio macularis of chinchilla rabbits. The angiographically visible lesions were histologically followed up to 4 weeks. With both irradiation modalities the original retinal pigment epithelium (RPE) was replaced by a monolayer of new RPE cells. Only minimal immediate and no subsequent damage to the photoreceptors was found after selective RPE photocoagulation. Only minimal inflammatory response was found after selective RPE photocoagulation in contrast to CW photocoagulation where macrophages, RPE cells and lymphocytes regularly appear in the damaged photoreceptor layer.

Animals↗

[Quantification of indocyanine-green enhancement of diode laser photocoagulation].

The enhancement by indocyanine-green (ICG) of diode laser photocoagulation was quantified. Since ICG concentration in blood increases and decreases rapidly after a single injection, it is difficult to quantify the exact enhancing effect of ICG. A steady-state plasma concentration (about 30 micrograms/ml) of ICG was achieved by injection of 2.5 mg/kg of ICG followed by continuous injection of 0.45 micrograms/kg/min of ICG. The threshold energy values to obtain grayish white retinal burn or choriocapillary occlusion were evaluated at this steady concentration of ICG, and compared with the values in the absence of ICG. The use of ICG decreased the energy values 7% for retinal burn and 8% for choriocapillary occlusion. Although the total dosage of ICG during the continuous injection was high, the enhancement of retinal burn and choriocapillary occlusion was small.

Animals↗

[Spatial confinement of intraocular picoseconds-photodisruption effects].

Laser photodisruption is a routinely performed clinical procedure in intraocular microsurgery of post-cataract membranes, anterior synechies and iridectomies. Damage ranges of several millimeters in diameter, however, limit the use of nanosecond photodisruption close to delicate structures, e.g., in the posterior vitreous. Multiple ps-laser pulses of about 100 microJ pulse energy were used to produce disruptive effects in the anterior lens capsule in rabbit eyes in vivo. Ophthalmoscopical and morphological investigations of these effects were compared with those of minimal ns-disruptions. The direct tissue separation effects as well as the collateral damage zones are about one order of magnitude smaller if ps-laser pulses are used. Minimal sizes of disruptive effects are about 50 microns to 150 microns and 500 microns to 1000 microns for ps- and ns-pulses, respectively. The substantial improvement of spatial confinement of ps-photodisruption enables increased precision of intraocular laser microsurgery and opens up new areas of clinical application in structures like the cornea, anterior chamber angle, and crystalline lens.

Animals↗

Response of the retinal pigment epithelium to selective photocoagulation.

Multiple short argon laser pulses can coagulate the retinal pigment epithelium selectively, while sparing the adjacent neural retina and choroid; in contrast, continuous-wave laser irradiation typically damages the neural retina and choroid. The healing response to selective photocoagulation of the retinal pigment epithelium was studied in rabbits during a period of 4 weeks. The lesions were never visible ophthalmoscopically. During the healing period, the epithelium was reformed by a single sheet of hypertrophic retinal pigment epithelial cells. In contrast to continuous-wave photocoagulation, only minimal inflammatory response was found. Retinal pigment epithelial cells showed clear signs of viability, eg, phagocytized outer segments. The local edema in the photoreceptor layer and subretinal space found in the early stage disappeared when the blood-retinal barrier was reestablished. The choriocapillaris remained unaffected. No subsequent damage to the photoreceptors was found. This type of photocoagulation may be useful for retinal pigment epithelium-related diseases, eg, diffuse diabetic macular edema.

Animals↗

Mid-infrared laser ablation of the cornea: a comparative study.

The ablation thresholds and patterns of collateral damage in cornea produced by Er:YAG (2.94 microns) and Er:YSGG (2.79 microns) lasers were measured. Two different pulse durations, 200 microseconds (normal spiking mode) and 100 ns (Q-switched mode), were used at both wavelengths. In the normal spiking mode, damage zones of 16 +/- 2 microns and 39 +/- 7 microns and ablation thresholds of 250 +/- 20 mJ/cm2 and 420 +/- 35 mJ/cm2 were measured at 2.94 microns and 2.79 microns, respectively. In the Q-switched mode, damage zones of 4 +/- 2 microns and ablation thresholds of 150 +/- 10 mJ/cm2 were found irrespective of the laser used. The similarity between the results using the Er:YAG and Er:YSGG lasers in the Q-switched mode suggest that either laser can be used with equal effectiveness for corneal trephination.

Animals↗

[Selective occlusion of ocular neovascularization by photodynamic therapy].

Photodynamic therapy (PDT) has successfully been used to induce vascular occlusion via endothelial damage and subsequent thrombosis. To increase the selective of this method for neovascularizations, characteristics in the ultrastructure of the proliferative vessel wall allow physiological vessels to be spared and predominantly neovascularizations to be occluded: (a) Due to the disturbance of the blood-retina barrier, free dye molecules accumulate within the vascular wall. Using a dye with prolonged retention, such as phthalocyanine (CASPc), it is possible to thrombose neovascularizations 24 h post injection while leaving the physiological vasculature of the anterior segment of the rabbit eye unaffected. (b) Proliferating endothelial cells express high numbers of low-density lipoprotein (LDL) receptors. Chlorin e6 (Ce6), a potent photosensitizer, is covalently bound to LDL. Intravascularly, ce6-LDL complexes selectively label neovascular walls. Since ce6-LDL is incorporated intracellular into enzymatically active lysosomes, photothrombosis is effectively achieved at low drug and light doses in vivo. In addition, the induced damage is spatially confined to the inner vascular lining. We conclude that carrier-mediated PDT may offer a new and sensitive approach for selective treatment of intraocular neovascularizations.

Animals↗

Optical properties of human sclera, and their consequences for transscleral laser applications.

The spectral dependence of the optical properties of human sclera adjacent to the limbus was investigated and related to the potentials of transscleral photocoagulation. The total transmission, absorption, and reflection, as well as the angular distribution of the transmitted and reflected light were measured at five laser wavelengths (442 nm, 514 nm, 633 nm, 804 nm, and 1,064 nm), both for noncontact and contact applications. Absorption and scattering coefficients were determined using the Kubelka-Munk model for light propagation through a scattering tissue. The scleral transmission is only 6% at 442 nm but increases to 35% at 804 nm and to 53% at 1,064 nm. The absorption is high at short wavelengths with 40% at 442 nm but it is only 6% at 804 nm and 1,064 nm. The reflection is generally higher than 40% and shows little wavelength dependence. The transmitted light is scattered diffusely at short wavelengths, but at 804 nm and 1,064 nm it exhibits a fairly narrow angular distribution in forward direction. Fiber contact leads to an increase of transmission, with a factor of 3.5 at 442 nm, of 2.0 at 804 nm, and 1.5 at 1,064 nm. Our results indicate that the diode laser (804 nm) and the Nd:YAG laser (1,064 nm) with contact delivery are best suited for transscleral photocoagulation.

Absorption↗

Application of the 1-microsecond pulsed-dye laser to the treatment of experimental cerebral vasospasm.

Laser energy of 480 nm was applied in 1-microsecond pulses varying between 2.2 and 10 mJ to in vitro and in vivo models of cerebral vasospasm. First, the pulsed-dye laser was applied intravascularly via a 320-microns fiber to basilar artery segments from six dogs. The segments were mounted in a vessel-perfusion apparatus and constricted to, on average, 70% of resting diameter by superfusion with dog hemolysate. Immediate increase in basilar artery diameter occurred to a mean of 83% of control. In a second model, the basilar artery was exposed transclivally in the rabbit. In three normal animals, superfusion of the artery with rabbit hemolysate resulted in a reduction of mean vessel diameter to 81% of control. Following extravascular application of the laser, vessels returned to an average of 106% of the resting state. In six rabbits, the basilar artery was constricted by two intracisternal injections of autologous blood. 3 days apart. Two to 4 days after the second injection, the basilar artery was exposed. Extravascular laser treatment from a quartz fiber placed perpendicular to the vessel adventitia resulted in an immediate 53% average increase in caliber to an estimated 107% of control. No reconstriction was observed over a period of up to 5 hours. Morphologically, damage to the arterial wall was slight. This preliminary investigation suggests that the 1-microsecond pulsed-dye laser may be of benefit in the treatment of cerebral vasospasm.

Animals↗

Treatment of vasospasm with a 480-nm pulsed-dye laser.

Laser energy at a wavelength of 480 nm was applied in 1-microseconds pulses of 3 to 10 mJ to two models of vasospasm. Rabbit common carotid arteries (CCA's) were constricted chronically by the application of human blood within a silicone sheath. Peak vasospasm developed 24 to 48 hours later, and persisted for up to 6 days. Endovascular laser treatment was delivered to 40 CCA's via a 200-microns diameter silica quartz fiber introduced through the femoral artery. The CCA caliber increased from 60% of the pre-vasospasm control diameter to a minimum post-laser diameter of 83% of control. No instances of laser-induced perforation or of arterial thrombosis were observed for up to 60 days after treatment. Prophylactic laser application to nine normal vessels was able to attenuate the development of vasospasm if blood was applied immediately thereafter (88% vs. 59% of control diameter, p less than 0.02), but not if blood was applied 7 days later. Studies in 16 normal CCA's established that there was a considerable margin between the laser energy required to induce dilatation and that which caused perforation, providing that the fiber remained relatively central within the artery. Morphological examination demonstrated focal loss of endothelial cells immediately after laser application, followed approximately 7 days later by the development of areas of intimal hyperplasia. Only minimal changes were observed in the medial or adventitial layers. In a second study, the basilar artery of seven dogs was constricted chronically by two intracisternal injections of autologous blood 3 days apart. Five dogs received endovascular laser treatment 7 or 10 days after the first injection, when basilar artery diameter was reduced to a mean of 61% and 77% of control, respectively. Immediately following treatment, basilar artery diameter increased to 104% and 102% of resting diameter, respectively. Both untreated and laser-treated arteries were smaller than the control diameter at 30 days (80% and 82%, respectively), but in each group the vasodilatory response to hypercapnia was preserved. These findings indicate that 1-microsecond laser pulses are well tolerated by systemic and cerebral arteries in two different animal models, and suggest that the 480-nm pulsed-dye laser may have an application for the treatment or prophylaxis of cerebral vasospasm.

Animals↗

[Microcoagulation of the fundus. Experimental results of repeated laser pulse exposure].

Angiographically visible lesions were produced in the fundus of rabbit eyes with repetitive 5 microseconds pulses and continuous wave exposures with 50-ms to 1-s pulse duration from an modified argon laser (514 nm). The ophthalmoscopic and the fluorescein angiographic findings showed less damage in the neural retina and the choroid after repetitively pulsed irradiation. Light microscopy and transmission electron microscopy showed that the neural retina and the choroid can mostly be spared by using repetitive 5 microseconds pulses, even though the damage to the retinal pigment epithelium is similar to the damage caused by continuous wave irradiation. Possible clinical applications, e.g. for macular edema and central serous retinopathy, are discussed.

Animals↗

[Optical properties of human sclera and their significance for trans-scleral laser use].

The spectral dependence of the optical properties of human sclera adjacent to the limbus was investigated and related to the potentials of transscleral photocoagulation. The total transmission, absorption and reflection and the angular distribution of the transmitted and reflected light were measured at five laser wavelengths (442 nm, 514 nm, 633 nm, 804 nm, and 1064 nm) for both noncontact and contact applications. The scleral transmission is only 6% at 442 nm, but increases to 35% at 804 nm and 53% at 1064 nm. The absorption is high at short wavelengths, with 40% at 442 nm, but it is only 6% at 804 nm and 1064 nm. The reflection is generally higher than 40% and shows little wavelength dependence. The transmitted light is scattered diffusely at short wavelengths, but at 804 nm and 1064 nm it exhibits a fairly narrow angular distribution in the forward direction. Fiber contact leads to an increase in transmission, with a factor of 3.5 at 442 nm, of 2.0 at 804 nm, and of 1.5 at 1064 nm. Our results indicate that the diode laser (804 nm) and the Nd:YAG laser (1064 nm) are best suited for transscleral photocoagulation and that contact delivery leads to a reduction of the energy required for cyclophotocoagulation.

Ciliary Body↗

Laser sclerostomy by pulsed-dye laser and goniolens.

We describe an ab-interno laser sclerostomy procedure using the method termed dye-enhanced ablation with a slit-lamp delivery system and special goniolens such that only the laser light beam penetrates the anterior chamber. The procedure uses a microsecond-pulsed-dye laser emitting at 666 nm and iontophoresis of methylene blue dye (absorption of 668 nm) into the sclera at the limbus to enhance the absorption of the laser light. We compared the number of pulses needed to perforate excised human sclera at pulse durations of 1.5, 20, and 300 microseconds. Pulse durations of 1.5 and 20 microseconds required 20 pulses or fewer to perforate excised human sclera with pulse energies of 75 to 100 mJ. The ab-interno laser sclerostomy procedure was performed in 54 eyes of Dutch-belted rabbits with pulse durations of 1.5 or 20 microseconds and a 100- or 200-microns incident spot diameter delivered using a CGF goniolens. Full-thickness fistulas were successfully created at both pulse durations in approximately 80% of eyes treated. A range of three to 25 pulses was required to perforate sclera with slightly fewer pulses and lower pulse energies at 1.5 microseconds compared with 20 microseconds. There were no significant complications from the procedure. This technique could permit filtration surgery to be performed on an outpatient basis.

Animals↗

Semiconductor diode laser photocoagulation in retinal vascular disease.

The authors successfully performed clinical transpupillary retinal photocoagulation in 30 eyes of 26 patients with retinal vascular disease using a gallium-aluminium-arsenide (GaAlAs) diode laser emitting at 805 nm. Retinal photocoagulation was performed at treatment powers of 300 to 1300 mW and exposure durations of 0.2 to 0.5 seconds with a 200-microns diameter treatment spot. Patients treated with both diode and argon green lasers required 4.5 +/- 1.8 times greater mean laser energy with diode compared with argon to create ophthalmoscopically similar lesions. Parallel experimental retinal photocoagulation in Chinchilla rabbits required 3.1 +/- 0.9 times more power to create ophthalmoscopically similar lesions with the diode laser than with the argon laser. Intraoperative subretinal hemorrhage occurred rarely in patients with an incidence of 4 (0.44%) of 9021 treatment spots. Patients complained of moderate-to-marked pain in 10 (43%) of 23 treatments initiated under topical anesthesia. A transpupillary diode laser may be used clinically to perform therapeutic retinal photocoagulation.

Adult↗

[Mechanism of action, scope of the damage and reduction of side effects in intraocular Nd:YAG laser surgery].

The damage mechanisms of intraocular Nd:YAG laser surgery and their respective damage ranges were investigated in vitro using bovine cornea specimens as a model tissue. The main damage mechanisms are plasma formation and expansion, emission of acoustic transients, and cavitation with jet formation. When a sequence of laser pulses is applied, the interaction of the acoustic transients with gas bubbles remaining from preceding laser exposures is also important. To distinguish the effects caused by the different physical mechanisms, laser pulses were aimed directly onto the corneal endothelium, and parallel to the cornea at various distances. Simultaneously, the cavitation bubble size was determined. The surface morphology and sections of the same lesions were studied by light and electron microscopy. The primary surgical mechanism is tissue evaporation by the laser plasma, whereas the collateral damage from single laser pulses is mainly caused by the cavitation and jet formation. The damage range after a 4-mJ laser pulse is 0.8 mm which is slightly larger than the corresponding cavitation bubble radius. The damage range of the acoustic transients produced by a 4-mJ laser pulse is several millimeters, when they can interact with small gas bubbles attached to the corneal endothelium. The damage range of the acoustic transients alone is smaller than that of cavitation as far as damage detected by light and scanning electron microscopy is concerned. However, on a subcellular level the acoustic transients may possibly cause damage up to a much larger distance. The damage range observed varies with the cube root of the laser pulse energy. A reduction of collateral effects therefore requires the use of small pulse energies. For energies of less than 1 mJ, the pulse duration has to be reduced to ensure plasma production. It is proposed to use low-energy picosecond pulses with moderate repetition rate instead of single nanosecond pulses to reduce collateral damage effects.

Animals↗

Nd:YAG laser photodisruption of hemorrhagic detachment of the internal limiting membrane.

We used a Q-switched Nd:YAG laser to create an opening in the internal limiting membrane in three eyes with hemorrhagic detachment of the internal limiting membrane. In all instances, after membranotomy blood was rapidly cleared from the preretinal space resulting in prompt improvement in visual acuity. No retinal injury was observed. Nd:YAG laser photodisruption may be useful in the treatment of some cases of subinternal limiting hemorrhages.

Adult↗

Corneal ablation by nanosecond, picosecond, and femtosecond lasers at 532 and 625 nm.

We produced corneal excisions with nanosecond (ns)-, picosecond-, and femtosecond (fs)-pulsed lasers at visible wavelengths. The threshold energy for ablation was proportional to the square root of the pulse duration and varied from 2.5 microjoules (microJ) at 100 fs to 500 microJ at 8 ns. Excisions made with picosecond and femtosecond lasers was ultrastructurally superior to those made with nanosecond lasers and, at pulse energies near threshold, showed almost as little tissue damage as excisions made with excimer lasers at 193 nm. We conclude that ultrashort-pulsed lasers at visible and near-infrared wavelengths are a possible alternative to excimer lasers for corneal surgery and might have advantages over conventional ophthalmic neodymium-YAG lasers for some intraocular applications.

Animals↗