Computerized analysis of myocardial echocardiographic enhancement during coronary revascularization by high-speed rotational atherectomy.

A previous report demonstrated transient myocardial echocardiographic contrast (MEC) enhancement following high-speed rotational atherectomy (HSRA). This phenomenon was found to be correlated to the speed and duration of rotation and related to creation of cavitations. To determine other correlations and the significance of MEC, continuous echocardiographic recording was performed in 10 patients undergoing HSRA. Images were digitized and videointensity-time curves generated. Curve parameters were calculated and correlated with procedural variables, plaque mass, and side effects. Twenty-nine ablation passes in 10 patients were analyzed. Videointensity peaked 9-44 sec from initiation of ablation and decayed to a higher baseline level after each consecutive ablation. Increase in peak contrast intensity (PCI) from baseline and the percentage of the left ventricle undergoing enhancement were highest (33 +/- 31 gray level/pixel and 32% +/- 8%, mean +/- SD, respectively) after the second rotation and were not influenced by the duration of rotation. PCI, side effects, and transient left ventricular wall motion abnormalities were positively correlated with plaque mass, defined by the product of lesion length, diameter, and percent stenosis. HSRA resulted in significant myocardial echocardiographic contrast. PCI is related to ablation sequence and plaque mass. Plaque debris embolization is probably responsible for myocardial echocardiographic contrast and transient wall motion abnormalities. Cathet. Cardiovasc. Intervent. 49:39-44, 2000.

Aged

Interindividual heterogeneity in the hypoxic regulation of VEGF: significance for the development of the coronary artery collateral circulation.

BACKGROUND: The coronary artery collateral circulation may be beneficial in protecting against myocardial ischemia and necrosis. However, there is a tremendous interindividual variability in the degree of new collateral formation in patients with coronary artery disease. The basis for this interindividual heterogeneity is not understood. In this study we test the hypothesis that failure to generate collateral vessels is associated with a failure to appropriately induce with hypoxia or ischemia the angiogenic factor, vascular endothelial growth factor (VEGF). METHODS AND RESULTS: We correlated the VEGF response to hypoxia in the monocytes harvested from patients with coronary artery disease with the presence of collaterals visualized during routine angiography. We found that there was a highly significant difference in the hypoxic induction of VEGF in patients with no collaterals compared with patients with some collaterals (mean fold induction 1.9+/-0.2 versus 3.2+/-0.3, P<0.0001). After subjecting the data to ANCOVA, using as covariates a number of factors that might influence the amount of collateral formation (ie, age, sex, diabetes, smoking, hypercholesterolemia), patients with no collaterals still have a significantly lower hypoxic induction of VEGF than patients with collaterals. CONCLUSIONS: This study provides evidence in support of the hypothesis that the ability to respond to progressive coronary artery stenosis is strongly associated with the ability to induce VEGF in response to hypoxia. The observed interindividual heterogeneity in this response may be due to environmental, epigenetic, or genetic causes. This interindividual heterogeneity may also help to explain the variable angiogenic responses seen in other conditions such as diabetic retinopathy and solid tumors.

Cell Hypoxia

First clinical experience with the premounted balloon-expandable serpentine stent: acute angiographic and intermediate-term clinical results.

The beStent-Artist coronary stent is a newly developed, stainless steel coronary stent with a serpentine tubular design and terminal stent markers, premounted on a semicompliant balloon. During this pilot evaluation we aimed to test the acute clinical and angiographic results, short-term (30 days) and 6-month clinical results. A total of 57 stents were used to treat 43 lesions in 40 patients. Deployment strategy included predilatation, stent deployment, balloon repositioning to match the distal end of the balloon to the distal stent marker, and subsequent 12-14 atm postdilatation. There were two cases of stent dislodgment, but no procedural complications. In four cases, stent recrossing with another balloon was necessary. In two of these cases, distal dissections were observed and treated with another stent. The minimal lumen diameter (MLD) increased from 0.84+/0.52 mm at baseline to 2.7+/-0.62 mm at the end of the procedure (a corresponding decrease in diameter stenosis from 78.6 > 16.4 to 18.2+/-10.7%). The acute gain was 1.89+/-0.61mm. No adverse events occurred by 30 days. During six months, 7/40 (18.5%) of patients required target vessel revascularization due to in-stent restenosis. In summary, the premounted beStent-Artist can be delivered and deployed with favorable immediate results and high success rate with favorable long-term recurrent event rates.

Adult

On the human left ventricular shape.

The geometry of the heart plays a major role in cardiac function. The purpose of this study was to characterize analytically the geometric properties of the left ventricular (LV) three-dimensional (3D) shape, while excluding the effects of aspect ratio and size. Two groups of human hearts were studied by Cine-CT. The first group was composed of 10 healthy volunteers and the second of 9 pathological hearts. The hearts were scanned from apex to base. The endocardial borders of each LV scan were traced and used to reconstruct the 3D LV at end-diastole (ED) and end-systole (ES). Using a special normalized helical shape descriptor, denoted "geometrical cardiogram" (GCG), the typical 3D normal ED and ES shapes were determined. These typical shapes were then analytically approximated via a discrete cosine transform (DCT). The shape of each LV was then investigated for its correspondence to five analytically defined shapes: (i) a cone, (ii) a sphere, including all ellipsoidal shapes, (iii) a cylinder, (iv) a truncated ellipsoid, and (v) the DCT approximation of the normal LV shape. The results indicate that the normal LV shape can be well approximated by using only seven coefficients of the DCT. Conicity was the only geometrical feature which did not change from ED to ES in the normal group of hearts. The most prominent shape difference between normal and abnormal hearts was the significantly reduced conicity of the latter. Conicity is an important feature of LV geometry. The possible contribution of the conical shape to LV ejection efficiency is also discussed.

Adult

Continued expansion of the nitinol self-expanding coronary stent: angiographic analysis and 1-year clinical follow-up.

BACKGROUND: This study sought to report the first-year clinical outcome with the nitinol self-expanding coil stent and to provide angiographic data on the effect of self-expansion during implantation and follow-up. Self-expanding stents do not reach their nominal diameter at implantation. The long-term effects may therefore depend, in part, on continued expansion after initial implantation. METHODS: Between January 1995 and January 1996, 86 stents were deployed in 64 patients for indication of suboptimal results. All patients were clinically followed up for 1 year, and 72% had follow-up angiography. RESULTS: The majority (55%) of the lesions were class B2 or C. Balloon angioplasty increased the minimal lumen diameter from 1.07 +/- 0.73 mm to 2.24 +/- 0.57 mm; stent deployment further increased the diameter to 2.63 +/- 0.48 mm, and within-stent balloon dilatation to 2.96 +/- 0.62 mm. Angiographic follow-up performed at 7.8 +/- 1.1 months (range 7-9 months) showed that the minimal lumen diameter was 2.15 +/- 0.80 mm (late lumen loss of 0.81 +/- 0.69 mm), and the mean stent diameter expanded to 3.58 +/- 0.48 mm (self-expanding late stent gain of 0.62 +/- 0.55 mm). The extent of this expansion was inversely related to the late lumen loss (r = 0.67, slope 0.81, P <.01). At 1 year 51 (80%) of 64 patients were event free; 3 had undergone coronary artery bypass grafting, 2 had had a myocardial infarction, and 9 had repeat angioplasty. In the subgroup of a simple lesion (<15 mm) covered by 1 stent, 18 (86%) of 21 patients were event free. CONCLUSIONS: The self-expanding nitinol stent exerts its acute effect on minimal lumen diameter through its intrinsic radial force aided by balloon expansion. The stent continues to expand until it reaches its nominal diameter over the follow-up period. The extent of this expansion is inversely related to the late lumen loss, leading to an acceptable rate of long-term clinical events in this first cohort of patients with complex disease morphology.

Alloys

Regional differences in shape and load in normal and diseased hearts studied by three dimensional tagged magnetic resonance imaging.

OBJECTIVES: We aimed to characterize regional geometry in relation to load in two groups of patients with hypertrophic cardiomyopathy (HCM) and right ventricular pressure overload (RVPO) in relation to a group of subjects with normal left ventricular (LV) function. BACKGROUND: Both these diseases are associated with marked changes in LV shape and function, which have not been studied with detailed three dimensional tools. METHODS: Three dimensional (3D) tagged magnetic resonance imaging (MRI) was used to characterize the 3D geometry and regional stresses of the left ventricles in patients with HCM and RVPO. Curvatures, stresses, wall thickness, and endocardial motion were calculated from surface and volume elements. RESULTS: Hearts with RVPO exhibited more circumferential and meridional flattening of the septum than normal and HCM hearts. The stress indices were lowest in the HCM hearts, compared to normal and RVPO hearts, due to the larger thicknesses. There was a more significant difference between lateral wall motion and other regional wall motions in the HCM and RVPO hearts as compared to normal hearts. CONCLUSIONS: It is suggested that curvature and stress mapping by 3D tagged MRI can be used as an important clinical tool for characterizing and distinguishing between healthy and diseased hearts. The results provided here validated previous knowledge on HCM and RVPO known from planary imaging methods.

Adult

One-year clinical follow-up with the serpentine balloon expandable stent: report of the first 100 patients.

BACKGROUND: We recently reported a high technical and 30-day clinical success rate among the first 100 patients treated with the tubular, serpentine design, stainless steel, balloon-expandable stent (beStent) in Israel. The present study examined the clinical results in these patients after the first year. METHODS: Seventy-eight men and 22 women were included in the study. Previous myocardial infarction, bypass surgery and percutaneous transluminal coronary angioplasty had occurred in 52%, 12% and 26% of the patients, respectively. Diabetes mellitus was present in 30 patients and hypertension in 34 patients. One hundred and forty-eight stents of 15, 25, and 35 mm lengths were used. The indications for stenting were suboptimal results (n = 85), bailout conditions (n = 10) or for the prevention of restenosis (n = 8), and lesion types were A (n = 10), B1 (n = 29), B2 (n = 20), and C (n = 44). All patients were clinically monitored with regular visits at 1, 3, 6, 9 and 12 months. RESULTS: Overall, the 12-month event-free survival rate was 82%. Subacute thrombosis occurred in two patients. There were two non-cardiac deaths, one O-wave myocardial infarction, six elective bypass surgeries and 12 target lesion revascularizations. Event-free survival was significantly higher for those with lesions shorter than 15 mm than for those with lesions longer than 15 mm (90% versus 67%, P = 0.003), and for women compared with men (96% versus 78%, P = 0.02). CONCLUSIONS: The initial experience with the beStent shows favorable long-term results with an overall event rate of 18% for this subset of relatively complex lesions; higher event rates were observed for longer lesions.

Angioplasty, Balloon, Coronary

Percutaneous closure of a coronary aneurysm with a vein-coated stent.

Coronary artery aneurysm is a rare but recognized complication following percutaneous intervention. We report the formation of such an aneurysm after recanalization with Excimer laser wire of a chronic totally occluded left anterior descending coronary artery and stent implantation and its subsequent treatment using an autologous vein graft-coated stent.

Adult

Evaluation of the compressive mechanical properties of endoluminal metal stents.

The mechanical properties of metal stents are important parameters in the consideration of stent design, matched to resist arterial recoil and vascular spasm. The purpose of this study was to develop a system for a standardized quantitative evaluation of the mechanical characteristics of various coronary stents. Several types of stents were compressed by external hydrostatic pressure. The stent diameter was assessed by placing a pair of small ultrasonic sono-crystals on the stent. From pressure-strain diagrams the ultimate strength and radial stiffness for each stent were determined. For all stents, except the MICRO-II and the Wiktor stent, the diameter decreased homogeneously until an ultimate compressive strength was exceeded, causing an abrupt collapse. Expanded to 3 mm, the mechanical behavior of the beStent, the Crown and the Palmaz-Schatz stent (PS153-series) were comparable. The spiral articulated Palmaz-Schatz stent showed twice the strength (1.26 atm) of the PS-153 (0.65 atm). The NIR stent yielded a maximum strength of 1.05 atm. The MICRO-II and the Wiktor stent did not collapse abruptly but rather showed a continuous decline of diameter with increasing external pressure. The Cardiocoil stent behaved in a fully elastic manner and showed the largest radial stiffness. Difference in mechanical properties between stents were documented using a new device specifically developed for that purpose. These mechanical stent parameters may have important clinical implications.

Alloys

Determinants of regional myocardial function in patients with chronic significant coronary stenosis or occlusion.

BACKGROUND: Our aim was to study the effect of collateral flow, stenosis severity, antegrade flow, and location of the lesion on regional myocardial function in patients with chronic left anterior descending (LAD) coronary artery disease. METHODS AND RESULTS: Seventy-four patients who underwent coronary angiography and ventriculography were divided into three groups: group A (n = 9), patients with normal coronary angiogram and ventriculogram; group B (n = 32), patients with LAD stenosis >75%; and group C, 33 patients with LAD occlusion. The effect of collateral flow, stenosis severity, location, and antegrade flow on regional myocardial function in the LAD territory was studied. Regional function was impaired in both groups B and C. In group B, univariate analysis confirmed that antegrade flow had a significant effect on regional function (p < 0.02). With the use of multiple regression, none of the other variables had an additional independent effect. In group C, no significant correlation was found between regional function and the study variables by univariate analysis; however, multiple regression revealed a significant correlation between anterobasal function, the lesion site (p = 0.01), and collateral flow (p = 0.02). CONCLUSIONS: In patients with LAD stenosis, antegrade flow has the strongest effect on regional myocardial function, with no additional effect of visible collaterals. In patients with LAD occlusion, both angiographic collateral flow and the site of the lesion have a significant effect on the function of the anterobasal area.

Blood Flow Velocity

Cone and plate(let) analyzer: monitoring glycoprotein IIb/IIIa antagonists and von Willebrand disease replacement therapy by testing platelet deposition under flow conditions.

Exposure of citrated whole blood samples to polystyrene plates under flow conditions with the cone and plate(let) analyzer (CPA) results in surface immobilization of plasma von Willebrand factor (vWF) followed by platelet deposition. Staining the plates allows measurement of the percentage of surface covered (SC) by the adhered particles and their average size (AS). Both SC and AS parameters depend on platelet count and hematocrit level and reach maximal values after 2 minutes; only AS is shear rate dependent. Under optimal assay conditions (2 minutes at 1800 sec(-1)) normal blood samples yielded an SC of 14.9% +/- 2.5% and an AS of 39.4 +/- 5.2 microm2. Severe von Willebrand disease (eight patients) yielded low SC (5.2% +/- 2.1%), which was restored to normal by testing with vWF precoated surfaces. Glanzmann's thrombasthenia (six patients) samples demonstrated no adhesion of platelet at all. Blocking of the glycoprotein (GP) IIb/IIIa receptor by the chimeric antibody abciximab, and of the GPIb by a recombinant vWF fragment, have yielded a dose-response inhibition demonstrating the crucial role of these receptors in platelet deposition on polystyrene plates in this system. Evaluation of a patient with severe von Willebrand disease receiving replacement vWF factor VIII therapy revealed a comparable response as tested by both the CPA and the Ricof methods. In vitro testing of the GPIIb/IIIa blocking by a nonpeptidic analogue tirofiban and abciximab revealed a good correlation between the CPA test and the routine aggregometry. Eleven patients treated by abciximab after coronary angioplasty were studied by the CPA during the first 24 hours, demonstrating a marked decrease in SC and AS, with some diversity in the responses. We conclude that the CPA test is suitable for evaluation of primary hemostasis and for monitoring of anti-platelet drugs.

Blood Circulation

Thermographic imaging in the beating heart: a method for coronary flow estimation based on a heat transfer model.

Intraoperative thermographic imaging in open-chest conditions can provide the surgeon with important qualitative information regarding coronary flow by utilizing heat transfer analysis following injection of cold saline into the aortic root. The heat transfer model is based on the assumption that the epicardial temperature changes are mainly due to convection of heat by the blood flow, which may, therefore, be estimated by measuring the temperature variations. Hearts of eight dogs were exposed and imaged by a thermographic camera. Flow in the left arterial descending (LAD) coronary branch was measured by a transit-time flowmeter. 20 ml of cold saline were injected into the aortic root (just after the aortic valve) and the epicardial temperature images were recorded at end-diastole, for 20-30 s. Different flow rates were achieved by 1 min occlusion of the LAD, which affected a reactive hyperemic response. The dynamics of the temperature in the arterial coronary tree was obtained by averaging the temperature over an edge-detected arterial segment for each frame. The heat transfer equation was curve-fitted, and the flow-dependent heat transfer index was correlated with the experimentally determined coronary flow (r = 0.69, p < 0.001). In summary: a method for quantitative estimation of coronary blood flow by thermography and heat transfer analysis was developed and tested in animal experiments. This method can provide important information regarding coronary blood flow during open-chest surgical procedures.

Animals

beStent--the serpentine balloon expandable stent: review of mechanical properties and clinical experience.

The objective of this study was to present the engineering and clinical aspects of a new balloon expandable coronary stent. A new tubular, serpentine design stainless steel balloon-expandable stent, the beStent, was designed based on clinical requirements for stents and has been clinically evaluated in multiple sites. The stent is featured by terminal gold markers and rotational junctions that assure no shortening upon expansion and lead to orthogonal locking, maximizing radial strength. In terms of methods and results, the stent was clinically evaluated in the framework of a pilot evaluation in a variety of lesion types. The short- and long-term results evaluated during the course of the beStent multicenter pilot evaluation and in our single center study are reported. A variety of patients were included, including patients with long complex lesions, restenosis lesions, and total occlusions. Short-term clinical success with stenting was achieved in more than 97% of the cases. Subacute thrombosis was low in 1% of the cases. Clinical restenosis rates were acceptable with an overall 85% 6 month event free survival. In conclusion, the mechanical features of the stent providing its flexibility, scaffolding properties, radial strength, and absence of shortening were tested in a clinical study, showing that it is safe and effective for treating simple as well as long and complex lesions associated with coronary disease with a relatively low rate of complications.

Adult

Estimation of coronary blood flow by ECG gated cardiac thermography in open-chest conditions.

Thermography is suggested as a tool to estimate myocardial and coronary epicardial flow in open-chest heart surgery. To test the feasibility and compare various methods for coronary flow estimation in open-chest surgery, thermographic imaging was applied to eight open-chest dogs which were injected with cold saline into the aortic root. Blood flow in the left arterial descending (LAD) coronary vessel was measured by a transit-time flowmeter. ECG gated images were acquired for 20-30 s, while the cold saline (20 ml) was injected into the aortic root. Several flow levels were achieved during repeated hyperaemic response to transient occlusions of the LAD. A temperature response curve for each flow level was obtained by averaging over an edge-detected arterial segment for each image frame. Several indices were calculated from the temperature curve and correlated with the measured coronary flow. These include: an index based on a corrective heat transfer model (r = 0.69, p < 0.001), the slope of the descending part of the response curve (r = 0.76, p < 0.001), the peak temperature difference (r = 0.66, p < 0.001), and the area above the temperature response curve (r = 0.61, p < 0.01). As shown, coronary flow can be estimated quantitatively by intraoperative epicardial thermography, and may therefore provide important on-line information regarding blood flow during open-chest surgical procedures. Further studies are required for optimal application of this technique so as to increase its potential as a valid clinical tool.

Animals

Acute and 30-day results of the serpentine balloon expandable stent implantation in simple and complex coronary arterial narrowings.

We report the acute and 30-day results with a new serpentine-design, tubular, stainless steel, balloon-expandable stent (beStent) in the first 100 patients. One hundred forty-eight stents were used to treat 103 narrowings in the left anterior descending (n = 46), left circumflex (n = 20), and right coronary (n = 37) arteries. There were 85 de novo and 18 restenotic lesions (lesion length: < 10 mm [31], 10 to 20 mm [43] > 20 mm [29]; lesion type: A [10] B1 [29], B2 [20], C [44]; total occlusions, 23. More than 1 stent was used in 31 patients for treatment of long lesions that could not be covered by 1 stent. The stents used were 15-mm (n = 106), 25-mm (n = 38), or 35-mm (n = 4) long. Stent implantation strategy involved predilatation, deployment, and high-pressure dilatation, using the same balloon if possible. Clinical in-hospital success was 97% (2 patients had stent thrombosis that was recanalyzed, with myocardial infarction developing in 1, and 1 patient died on day 14 from retroperitoneal bleeding treated with surgery and complicated by sepsis). One-month event-free survival was 96%, with 1 death on day 21 due to hypertensive crisis. There were no other major adverse cardiac events in this first complex cohort of patients. In conclusion, the initial experience with this stent demonstrates its safety and efficiency for treating simple and complex coronary disease, with a relatively low rate of complications. Long-term clinical follow-up awaits further investigation.

Angioplasty, Balloon, Coronary

Dynamics of left ventricular apex rotation during angioplasty: a sensitive index of ischemic dysfunction.

BACKGROUND: Apex rotation has been shown to provide a reliable index of the dynamics of left ventricular (LV) twist. In this study, we aimed to characterize twist at baseline and during acute ischemia in 20 patients undergoing percutaneous transluminal coronary angioplasty to the left anterior descending (LAD) artery and to test whether an old myocardial infarction or collateral flow affected twist dynamics. METHODS AND RESULTS: Among patients with no previous infarction, five had no collaterals (group A) and six had angiographically visible collaterals (group B). Previous anterior infarction was present in nine patients (group C). Data were acquired with the LAD angioplasty wire passed beyond the apex using a view aligned with the LV long axis. Frame-by-frame dynamics of apex rotation were measured from the angular movement of the portion of the wire that traversed the apex. Aortic pressure recordings allowed precise temporal definition of the cardiac cycle. Dynamics of apex rotation were measured at fixed intervals until 60 seconds of occlusion and up to 60 seconds of reperfusion. In group A, counterclockwise apex rotation (twist) during ejection of -22.0+/-1.7 degrees (mean+/-SEE) was followed by rapid clockwise rotation (untwist) during isovolumic relaxation. During 60 seconds of ischemia, maximum apex rotation decreased to -8.2+/-2.0 degrees (P<.001 versus baseline). In group B, baseline apex rotation was similar (-26.2+/-6.9 degrees) to that in group A, but ischemia had less effect, with apex rotation values of -17.7+/-3.4 degrees (P<.05 versus group A values). Group C was characterized by reduced baseline apex rotation values (-9.7+/-3.1 degrees, P<.05 versus group A values), with little change observed during ischemia (-8.1+/-2.6 degrees). CONCLUSIONS: Apex rotation, an index of ventricular twist, is sensitive to acute ischemia in patients without previous myocardial infarction. Visible collaterals to the ischemic region attenuate the acute ischemic response at 60 seconds. Previous myocardial infarction causes abnormalities in the baseline twist pattern with no further deterioration at 60 seconds of ischemia.

Adult

Dynamic interaction between myocardial contraction and coronary flow.

Phasic coronary flow is determined by the dynamic interaction between central hemodynamics and myocardial and ventricular mechanics. Various models, including the waterfall, intramyocardial pump and myocardial structural models, have been proposed for the coronary circulation. Concepts such as intramyocardial pressure, local elastance and others have been proposed to help explain the coronary compression by the myocardium. Yet some questions remain unresolved, and a new model has recently been proposed, linking a muscle collagen fibrous model to a physiologically based coronary model, and accounting for transport of fluids across the capillaries and lymphatic flow between the interstitial space and the venous system. One of the unique features of this model is that the intramyocardial pressure (IMP) in the interstitial space is calculated from the balance of forces and fluid transport in the system, and is therefore dependent on the coronary pressure conditions, the myocardial function and the transport properties of the system. The model predicts a wide range of experimentally observed phenomena associated with coronary compression.

Animals