The Tower of Babel, by Pieter Bruegel, Kunsthistorisches Museum, Wien Oder KHM, Vienna (with permission).
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to R Berguer.
Explore the source record for details and available documents.
BACKGROUND: Hand size is an important variable to consider when designing hand tools. Laparoscopic surgical instruments have been reported to cause hand and upper extremity discomfort. This study investigates the correlation between surgical glove size, preexisting musculoskeletal problems, and difficulty using laparoscopic instruments. METHODS: Approximately 11,000 questionnaires were sent to SAGES, AAGL, and AWS members. Questions included basic demographic and practice data, surgical glove size, the presence of musculoskeletal problems, and the perceived difficulty using several types laparoscopic instruments. There were 726 responses (from 159 women and 567 men). Subjects were grouped by hand size (Small < or =6.5, Medium 7.0-7.5, Large >7.5; female group only: Small < or =6.0, Medium 6.5, Large >6.5). ANOVA was used to test for differences between groups. RESULTS: The percentage of time subjects reported having difficulty using all laparoscopic instruments was greater for the Small glove size group compared to both the Medium and Large groups ( p < 0.001). In females, the scissors and staplers were more difficult to use for the Small and Medium glove size group compared to the Large group ( p < 0.001). Subjects who reported musculoskeletal problems ( n = 145) performed a significantly greater percent of laparoscopic cases and found the stapler and graspers difficult to use for a greater percentage of time than those not reporting problems ( n = 559). CONCLUSION: Hand size is a significant determinant of difficulty using laparoscopic surgical instruments. Individuals using glove sizes 6.5 or smaller experience significantly more difficulty using common laparoscopic instruments, and in particular laparoscopic staplers. Manufacturers of surgical hand tools should consider hand size when designing future surgical instruments.
BACKGROUND: Laparoscopic surgery may be kinder to the patient, but it is more demanding on the surgeon. Fixed trocar positions often require the surgeon to work with instruments at awkward angles to their body. We studied the effect of horizontal and vertical laparoscopic instrument working angle on the surgeon's thumb, forearm, and shoulder muscle work. METHODS: Electronyographic (EMG) signals were collected from the thenar compartment (TH), flexor digitorum superficialis (FDS), and deltoid (DEL) muscles of the dominant arm of eighth surgeons while they were closing a standard pistol-grip disposable laparoscopic grasper against a fixed resistance of 3 N. With the aid of a special testing bench, the instruments' position was randomly changed among 15 degrees, 45 degrees, and 75 degrees of horizontal angulation relative to the surgeons' sagital plane, and 15 degrees, 45 degrees, and 75 degrees degrees of vertical angulation relative to a horizontal plane. EMG signals were rectified and smoothed using analogue circuitry and digitally sampled at l0 Hz using a National Instruments DAQCard-700 connected to a Macintosh PowerBook 5300c running LabVIEW software. Statistical analysis was carried out by analysis of variance (ANOVA). RESULTS: The effects of vertical and horizontal working angles on the muscle effort were as follows: TH (horizontal, N.S.; vertical, N.S.), FDS (horizontal, p 45 degrees to the surgeon's sagital plane significantly increases the workload of the flexor digitorium superficialis and deltoid muscles. The deltoid muscle is also adversely affected by vertical angulation of the instrument. The instrument working angle has no effect on the thenar muscles. Whenever possible, laparoscopic surgeons should strive to place their instruments and trocars so as to minimize extreme horizontal or vertical displacement of their hands away from a resting position of comfort.
Explore the source record for details and available documents.
BACKGROUND: The awkward visual and physical interface of video-endoscopic surgery (VES) has been shown to increase the physical workload of the surgeon, yet there is a lack of objective information on the mental effort and stress demanded by VES techniques. This study addresses the hypothesis that VES is more stressful than open surgery using an ergonomic analysis of surgical tasks in a laboratory setting. METHODS: A portable ergonomic work station was developed using a software Virtual Instrument (VI) interfaced with electronic hardware to compare the mental workload of 28 surgeons. The task was knot tying. The independent variable was work condition: rest, open technique, or VES technique. Dependent variables were tonic skin conductance level (SCL), electrooculogram (EOG), and subjective reports of concentration (CON) and stress (STR). Statistical analysis used nonparametric methods. RESULTS: Subjects tied fewer knots using the VES technique (p < 0.05). The SCL increased progressively from rest to the open task to the VES task (p < 0.05), correlating with the subjects' reported increase in mental stress level (p < 0.05). Eye blinks decreased from rest to the open task (p < 0.05), consistent with the subjects' reported increase in level of mental concentration. From the open to the VES task, eye blinks increased (p < 0.05), as would be expected given the greater demands of the VES task. Experienced subjects demonstrated less variability in SCL levels across tasks. CONCLUSIONS: VES technique requires greater concentration and places greater mental stress on surgeons than to open surgery. More experience with VES may decrease this effect. Studies are needed to improve the human-technology interface the stress.
BACKGROUND: Many surgeons have complained of fatigue and musculoskeletal pain after laparoscopic surgery. We evaluated differences in surgeons' axial skeletal and upper extremity movements during laparoscopic and open operations. METHODS: Five surgeons were videotaped performing 16 operations (8 laparoscopic and 8 open) to record their neck, trunk, shoulder, elbow, and wrist movements during the first hour of surgery. We also compared postprocedural complaints of pain, stiffness, or numbness between the two groups. RESULTS: Compared with surgeons performing open surgery, surgeons performing laparoscopic surgery exhibited less lateral neck flexion; less trunk flexion; more internal rotation of the shoulders; more elbow flexion; more wrist supination and wrist ulnar and radial deviation. There was a trend of more shoulder stiffness after laparoscopic operations than after open operations. CONCLUSIONS: Laparoscopic surgery involves a more static posture of the neck and trunk, but more frequent awkward movements of the upper extremities than open surgery. Ergonomic changes in the operating room environment and instrument design could ease the physical stress imposed on surgeons during laparoscopic operations.
PURPOSE: An endoleak results from the incomplete endovascular exclusion of an aneurysm. We developed an experimental model to analyze hemodynamic changes within the aneurysm sac in the presence of an endoleak, with and without a simulated open collateral branch. METHODS: With a latex aneurysm model connected to a pulsatile pump, pressures were measured simultaneously within the system (systemic pressure) and the aneurysm sac (intrasac pressure). The experiments were performed without endoleak (control group) and after creating a 3.5-mm (group 1), 4.5-mm (group 2), and 6-mm (group 3) diameter orifice in the endograft, simulating an endoleak. Pressures were also registered with and without a patent aneurysm side branch. RESULTS: In each endoleak group, the intrasac diastolic pressure (DP) and mean pressure (MP) were significantly higher than the systemic DP and MP (P =.01, P =.006, and P =.001, respectively), although the pressure curve was damped. The presence of an open side branch significantly reduced the intrasac DP and MP. CONCLUSION: In this model, intrasac pressures were significantly higher than systemic pressures in the presence of all endoleaks, even the smallest ones. Intrasac pressures higher than systemic pressure may pose a high risk for aneurysm rupture. Although patent side branches significantly reduce these pressures, the aggressive management of an endoleak should be pursued.
PURPOSE: The purpose of this study was to identify the risk and outcome of reconstruction of the extracranial vertebral artery (ECVA). METHOD: The study was conducted as a retrospective review of 369 consecutive ECVA reconstructions. RESULTS: The clinical presentations consisted of hemispheric symptoms alone in 4% of the cases, hemispheric and vertebrobasilar symptoms in 30%, and vertebrobasilar symptoms alone in 60%. The cause of the lesion was atherosclerosis (n = 300), extrinsic compression (n = 42), dissection (n = 7), radiation arteritis (n = 5), intimal hyperplasia (n = 3), fibromuscular dysplasia (n = 2), previous surgical ligation (n = 3), aneurysm (n = 2), and other (n = 5). All the patients underwent preoperative arteriography. There were 252 proximal ECVA reconstructions (218 transpositions, 42 bypass grafting procedures, and two other) and 117 distal ECVA reconstructions (85 bypass grafting procedures, 25 transpositions, and seven other). In 83 patients, the ECVA operation was performed concomitant with a carotid or supraaortic trunk reconstruction. This series was analyzed in two separate sets: before 1991 (n = 215), when changes in indications and management were occurring; and after 1991 (n = 154), when we acquired a dedicated anesthesia team and digital arteriography in the operating room and established uniform protocols for the management of ECVA disease. The stroke, death, and stroke/death rates for the period before 1991 were, respectively, 4. 1%, 3.2% and 5.1%. The stroke, death, and stroke/death rates for the period after 1991 were, respectively, 1.9%, 0.6% and 1.9%. The patency rate at 5 years was 80%. The survival rate at 5 years was 70%. Most of the deaths during the follow-up period were caused by cardiac disease. Among the survivors, the protection rate from stroke was 97%. CONCLUSION: The changes in operative selection and management have improved the results of ECVA reconstruction. The data reported for ECVA reconstruction in patients who underwent operation since 1991 reflect the outcome of ECVA reconstruction today. In our experience, a reconstruction of the ECVA is less risky than a carotid reconstruction.
Explore the source record for details and available documents.
The visual and physical interface imposed on the surgeon by video-endoscopic surgery (VES) increases the surgeon's mental workload. Ergonomic studies are needed to develop ways to reduce this workload. We used virtual instrumentation to devise a portable ergonomic workstation to compare the surgeon's mental workloads during simulated open surgery and VES. The system measures palmar tonic skin conductance level (SCL) and electrooculogram (EOG) and frontalis electrical activity to monitor mental stress and concentration levels. We used the system at a national surgery conference on volunteer subjects during a rest period and as they performed simulated surgery, consisting of typing knots using open and VES techniques. The subjects were asked to self-rate their levels of mental concentration and stress during these activities and reported that both progressively increased from rest to the open surgery task to the VES task. The subjects tied fewer knots during the VES than the open task, consistent with the increased demands of the VES task. The SCL progressively increased from rest to the open task to the VES task, correlating with the subjects' reported increase in mental stress level. Eye blinks and low frequency EOG activity decreased from rest to the open task, consistent with the subjects' reported increase in mental concentration level. From the open to the VES task, eye blinks and EOG activity increased, as expected given the greater demands of the VES task. High frequency frontalis activity merits further study as another indicator of the subjects' levels of mental concentration and stress.
BACKGROUND: Major surgery is known to suppress T-cell function; however, its differential effects on the production of helper T-cell type 1 (T(H)1) and type 2 (T(H)2) cytokines remains unknown. OBJECTIVE: To measure the production patterns of T(H)1 (interleukin 2 [IL-2] and interferon gamma) and T(H)2 (IL-4 and IL-10) cytokines following major surgery. DESIGN, SETTING, AND PATIENTS: A cohort study of patients (both active and former members of the armed forces) at a military hospital. INTERVENTION: Aortic surgery or carotid endarterectomy and measurement of serum IL-6 levels by enzyme-linked immunosorbent assay. MAIN OUTCOME MEASURES: Unstimulated and stimulated intracellular levels of IL-2, IL-4, IL-10, and interferon gamma in CD4+, CD8+, and gammadelta+ T cells and serum IL-6 levels immediately before and for 2 days after aortic surgery or carotid endarterectomy. RESULTS: No unstimulated production of T(H) or T(H)2 cytokines was detected. Stimulated intracellular levels of IL-2 and interferon gamma were significantly depressed during the postoperative period in all T-cell subsets in both patient groups. There were no postoperative increases in stimulated IL-4 or IL-10 levels. CONCLUSION: Major surgery suppresses the potential responses of T(H)1 cytokines without enhancing production of T(H)2 cytokines.
This article will provide the reader with an overview of ergonomic issues relevant to the operating room environment. Minimally invasive surgical technologies have increased the therapeutic value of surgical procedures by allowing operations to be performed with less trauma to the patient. At the same time, the surgical team-and particularly the surgeon-have been further removed from direct interaction with the patient's tissues. A scientific and ergonomic approach to the analysis of the operating room environment and the performance and workload characteristics of members of the modern surgical team can provide a rational basis for maximizing the efficiency and safety of our increasingly technology-dependent surgical procedures.
BACKGROUND: The Society of American Gastrointestinal Endoscopic Surgeons (SAGES) Task Force on Ergonomics conducted a subjective and objective assessment of ergonomic problems associated with laparoscopic instrument use. The goal was to assess the prevalence, causes, and consequences of operational difficulties associated with the use of laparoscopic instruments. METHODS: A questionnaire was distributed asking respondents to rate the frequency with which they experienced pain, stiffness, or numbness in several body areas after laparoscopic operations. An ergonomics station was assembled to quantify forearm and thumb muscle workload. Processed electromyogram (EMG) signals were acquired from 27 volunteer surgeon subjects while they completed simulated surgical tasks using a hemostat and an Ethicon laparoscopic grasper, with the aid of an endoscopic trainer and video monitoring system. RESULTS: Of 149 surgeons responding to the questionnaire, 8% to 12% reported frequent pain in the neck and upper extremities associated with laparoscopic surgery. The ergonomics station demonstrated that the peak and total muscle effort of forearm and thumb muscles were significantly greater (p < 0.01) when the grasping task was performed using the laparoscopic instrument rather than the hemostat. CONCLUSION: These findings indicate that laparoscopic surgical technique is more taxing on the surgeon.
A technique to expose directly the pars atlantica or the vertebral artery through a posterior approach was studied. It is useful when dealing with occlusive, aneurysmal, or dissecting lesions that extend to the transverse process of C1 or beyond. This technique permits exposure of the entire pars atlantica or the vertebral artery, from its exit from the foramen transversarium of C1 to its penetration of the dura mater at the foramen magnum. The experience with this technique in three patients is described.
PURPOSE: The purpose of this study was to review 182 consecutive cervical reconstructions of supra-aortic trunks, which were performed over a 16-year period. METHODS: A total of 182 innominate, common carotid, or subclavian arteries were reconstructed with a cervical approach in 173 patients aged 23 days to 83 years. Indications included hemispheric (n = 79), vertebrobasilar (n = 56), upper extremity (24), and internal mammary/cardiac ischemia (n = 5), asymptomatic severe common carotid disease (n = 33), or other (n = 3). Primary atherosclerotic innominate (n = 6), common carotid (n = 84), and subclavian (n = 66) lesions underwent reconstruction. Thirty-one operations were performed for multiple trunk involvement, recurrent disease, arteritis, infection, dissection, coarctation, or aneurysm. There were 122 bypass grafting procedures (98 ipsilateral, 24 contralateral) and 60 arterial transpositions. RESULTS: One death (0.5%) and 7 nonfatal strokes (3.8%) occurred, none in patients who were asymptomatic. Perioperative morbidity included four asymptomatic occlusions (2%), 6 myocardial infarctions (3%), 10 pulmonary complications (5%), and 2 graft infections (1%). Follow-up periods ranged from 1 to 190 months (mean, 53 +/- 5 months). Nineteen patients (10%) were lost to follow-up. Fifty-seven late deaths occurred, most from cardiac causes. Seven reconstructions necessitated late revision. The cumulative primary patency rate at 5 and 10 years was 91% +/- 2% and 82% +/- 5%, respectively. The survival rate at 5 years was 72% +/- 4% and at 10 years was 41% +/- 6%. The stroke-free survival rate was 92% +/- 2% at 5 years and 84% +/- 2% at 10 years. CONCLUSION: Cervical reconstruction of symptomatic and asymptomatic supra-aortic trunk lesions carries acceptable death and stroke rates and provides a long-term patient benefit. This should be the preferred approach for asymptomatic lesions and for patients with significant comorbidity because it carries less morbidity than direct transmediastinal aortic-based reconstruction.
Laparoscopic techniques allow for less-invasive treatment of common surgical problems. Laparoscopic instruments are different from standard surgical instruments and generally incorporate a pistol-grip handle configuration with rings for the fingers. This handle configuration has been reported as being uncomfortable, leading to finger compression neuropathies in some cases. As an alternative, the surgeon can choose to grasp laparoscopic instruments using a more powerful palm grip during grasping motions. This study evaluates the hypothesis that the use of the palm grip requires less muscle tension than the finger-grip when grasping with laparoscopic instruments. Nine general surgeons used an Autosuture laparoscopic grasper with a ringed pistol-grip handle held in both a finger-in-ring (F) or palm (P) hand grip position to grasp and close two spring-loaded metal plates. The same task was performed with a surgical haemostat clamp (H) for comparison. Each subject performed the grasping task in a random sequence for the three instrument configurations at two grasping forces levels (0.7 and 4.2 N), and with the instrument at three angles to the subjects' sagittal plane (0 degree, 45 degrees and 90 degrees). Surface electromyographic (EMG) signals were acquired from the flexor carpi ulnaris (FCU), flexor digitorum profundus (FDP), flexor digitorum superficialis (FDS), extensor carpi ulnaris (ECU), extensor digitorum comunis (EDC) and the thenar compartment (TH). The peak root mean squared (RMS) EMG voltage was averaged for five repetitions at each instrument, force and angle condition. Statistical analysis was carried out by repeated measures ANOVA. The muscle EMG RMS amplitude while using the palm grip was decreased in the FDS, TH and EDC, was unchanged in the ECU and FCU, and was slightly higher in the FDP when compared with the finger grip. These differences were most prominent at 90 degrees to the sagittal plane where the subjects' wrists neared maximal flexion. It is concluded that the palm grip is more powerful than the finger grip when grasping with laparoscopic instruments, particularly at angles perpendicular to the surgeon's sagittal plane.
Videoendoscopic (VES) instruments have poor force transmission properties and often require surgeons to employ awkward hand and arm positions. In order to compare the physical workload of laparoscopic surgery to open surgery, we collected long-duration EMG records from the thumb (thenar compartment) of six surgeons performing suturing and knot tying in a training box using both open and VES techniques. EMG signals were acquired using a LabVIEW Virtual Instrument and analyzed using a Modified Exposure Variation Analysis (MEVA) algorithm. Standard EMG indices and the MEVA analysis demonstrated significantly greater amplitude and duration of EMG signals using VES technique compared to open technique. Our results suggest that the use VES techniques requires a greater intensity of physical effort than open surgery techniques.
BACKGROUND: Laparoscopic surgery is associated with less tissue trauma and postoperative pain as well as a more rapid recovery than open surgery. We hypothesized that these factors may result in less immune impairment following laparoscopic surgery. METHODS: We measured mitogen-induced surface interleukin-2 receptor (IL2R) expression and lymphocyte proliferation in CD4+ and CD8+ T-lymphocytes as well as serum corticosterone levels in rats 24 h following open (OP) and laparoscopic (LAP) fundoplication. RESULTS: Serum corticosterone levels were lower in LAP vs OP rats (p = 0.02). CD4+ IL2R expression was higher in the blood, but not in the spleen, in LAP vs OP animals (p = 0.02). CD8+ IL2R expression was similar in both groups. Mitogen-induced lymphocyte proliferation was no different in the blood but decreased in the spleen in LAP vs OP rats (p = 0.03). CONCLUSIONS: Compared to open surgery, laparoscopic fundoplication in the rat results in lower adrenocortical hormone levels and better-preserved T-helper-cell activation in the blood. Lymphocyte proliferation is suppressed in the spleen 24 h after laparoscopic surgery. Minimally invasive surgery may better preserve cell-mediated immunity in the early postoperative period.