Search PubMedSearch

Biomedical subjects

R Balnave

Publications and source records attributed to R Balnave.

3 recordsLinked to original sources

Variability of grip strength during isometric contraction.

The use of measures of strength variability as a means of determining sincerity of effort is becoming a more common practice, particularly in medico-legal and rehabilitation settings. The stability of such variability measures, however, has not been documented. This research investigated, in two studies, the trial-to-trial variability of grip strength under maximal and submaximal effort conditions. In the first study, 63 subjects were asked to give 100% grip effort, and in the second study 40 subjects from the original group were asked to give 50% grip effort. The Jamar hand dynamometer was used to measure grip strength in both experiments, and a coefficient of variation (CV) was calculated for every three repeat measures at each handle position. Testing was conducted on two separate occasions for both experiments. Although the interoccasion reliability of grip strength was very high, in comparison, the CV was not stable over test occasions, with interoccasion reliability indices close to zero. Factors significantly influencing CV were effort level, with submaximal effort producing larger CVs, and gender, with females having greater strength variability. If the rule is applied that one or more CVs above the 7.5% cut-off value could indicate submaximal effort, then for this sample of subjects giving maximal effort, 97% of females and 64% of males would be misclassified. Applying a single CV classification cut-off value to a mixed sample of subjects appears to unfairly discriminate against the females. Further research into the factors associated with high CV values is essential before the CV can be used with any confidence in a clinical setting as a method for determining sincerity of effort.

Adult

Grip strength testing reliability.

The purpose of this study was to investigate the test-retest reliability of isometric grip strength testing using the Jamar dynamometer. Thirty-three subjects, 16 men (mean age = 37.4 years) and 17 women (mean age = 35.5 years), were assessed on two separate occasions using four methods to determine grip strength score. The methods used were (1) the score of one trial, (2) the mean score of two trials, (3) the mean score of three trials, and (4) the highest score of three trials. All five handle positions of the Jamar dynamometer were used during testing. Although still within the limits of acceptability, position 1 was significantly less reliable when compared with the other handle positions. Because the four methods of determining grip strength score were not significantly different in reliability, it was not possible to recommend any method as being more accurate. To analyze curve shape further, grip strength curves for the strongest and weakest men and women were compared by transforming points on the curves into percentages of the maximum value. Transformed curves for both strong and weak subjects were almost identical, indicating that, for this sample, "flattening" of the grip strength curves was a function of weak grip. The present data do not support the use of raw score curve shape as an indicator of sincerity of effort during grip strength testing.

Adult