Search PubMed⌕ Search

Biomedical subjects

R B Shack

Publications and source records attributed to R B Shack.

22 records · Page 2Linked to original sources

Revascularization of the poorly functioning kidney.

The effect of renal vascularization on renal function in kidneys with poor preoperative excretory function is summarized in this report. Twenty-five patients with kidneys having preoperative creatinine clearance of less than 30 ml/min, as determined during split renal function studies (SRFS), which were revascularized for treatment of secondary renovascular hypertension and then were reevaluated by repeat SRFS form the basis of this report. There were 13 male and 12 female patients. The type of renal artery lesion was atherosclerotic in 21 patients and fibromuscular dysplastic in four patients. Eight individuals had total renal artery occlusion. Significant contralateral renal artery disease was present in 15 patients (60%). Preoperative creatinine clearances in the affected kidneys ranged from 0.27 ml/min (mean, 16 +/- 9 ml/min). after operation, creatinine clearances ranged from 0 to 72 ml/min (mean, 32 +/- 16 ml/mn). Fifteen of the 16 kidneys with preoperative creatinine clearances less than 20 ml/min had improvement in renal function following revascularization (P less than 0.01). Improvement (60%) or cure (36%) in hypertension followed revascularization in 24 of the 25 patients. The most dependable predictor of successful management of both hypertension and retrieval of renal function in these patients was the arteriographic demonstration of a patent distal vessel without evidence of severe intrarenal stenoses. These results support an aggressive attitude toward the use of revascularization in the operative treatment of such patients with renovascular hypertension, even when the residual excretory function is minimal or absent.

Adult↗

Expanded polytetrafluoroethylene as dialysis access grafts: serial study of histology and fibrinolytic activity.

Expanded polytetrafluoroethylene (Gore-Tex) grafts were evaluated as hemodialysis access shunts. A serial study of cellular ingrowth and endothelialization was performed. The development of fibrinolytic activator was sequentially monitored and shown to be consistently higher in the Gore-Tex grafts than in either knitted or woven Dacron prostheses. Functional assessment by repeated needle puncture demonstrated that PTFE grafts were durable, had uniform patency (6 mm ID size) and showed no evidence of degeneration during the time limit of this study. Although these are favorable characteristics, further long-term evaluation of PTFE grafts is necessary before its role as a vascular prosthesis applicable to clinical practice, can be established.

Animals↗