Axial and total-body bone densitometry using a narrow-angle fan-beam.

We assessed a new dual-energy bone densitometer, the PRODIGY, that uses a narrow-angle fan-beam (4.5 degrees) oriented parallel to the longitudinal axis of the body (i.e., perpendicular to the usual orientation). High-resolution scans across the body can be stepped at 17 mm intervals. The energy-sensitive array detector uses cadmium zinc telluride, which allowed rapid photon counting. Spine and femur scans required 30 s, and total-body scans required 4-5 min; the dose was only 3.7 mrem and 0.04 mrem respectively, or about 5 to 10 times lower than conventional fan-beam densitometry. We found only a small influence of soft-tissue thickness on bone mineral density (BMD) results. There was also a small (+/- 1%) influence of height above the tabletop on BMD results. A software correction for object height allowed a first-order correction for the large magnification effects of position on bone mineral content (BMC) and area. Consequently, the results for BMC and area, as well as BMD, with PRODIGY corresponded closely to those obtained using the predecessor DPX densitometer, both in vitro and in vivo; there was a generally high correlation (r = 0.98-0.99) for BMD values. Spine and femur values for BMC, area and BMD averaged within 0.5% in vivo (n = 122), as did total-body BMC and BMD (n = 46). PRODIGY values for total-body lean tissue and fat also corresponded within 1% to DPX values. Regional and total-body BMD were measured with 0.5% precision in vitro and 1% precision in vivo. The new PRODIGY densitometer appears to combine the low dose and high accuracy of pencil-beam densitometry with the speed of fan-beam densitometers.

Absorptiometry, Photon↗

Evaluation of differences between fan-beam and pencil-beam densitometers.

We compared the bone and body composition results in vivo on two bone densitometers using fan-beam geometry (EXPERT and PRODIGY) with those using pencil-beam geometry (DPX). Measurements were made on large groups of adults ranging in weight from about 50 to 120 kg. Both spine and femur neck BMD on the fan-beam densitometers averaged within 1% of the pencil-beam results, and there was no magnitude dependence of the results by Bland-Altman analysis. Total body BMC and BMD on the PRODIGY and DPX were congruent, but on the EXPERT, BMC was about 2% lower and BMD 2% higher than corresponding values on the DPX. Soft-tissue composition was closely congruent for the PRODIGY and DPX; the comparable EXPERT-DPX differences showed greater scatter but no significant magnitude dependence. The smaller fan-angle of the PRODIGY (4 degrees ) probably contributed to its better congruence to pencil-beam results compared with the EXPERT (12 degrees ).

Absorptiometry, Photon↗

Intermittent doxercalciferol (1alpha-hydroxyvitamin D(2)) therapy for secondary hyperparathyroidism.

Hypercalcemia and hyperphosphatemia frequently necessitate vitamin D withdrawal in hemodialysis patients with secondary hyperparathyroidism. In short-term trials, doxercalciferol (1alpha-hydroxyvitamin D(2) [1alphaD(2)]) suppressed intact parathyroid hormone (iPTH) effectively with minimal increases in serum calcium and phosphorus (P) levels. This modified, double-blinded, controlled trial examined the efficacy and safety of 1alphaD(2) use in 138 hemodialysis patients with moderate to severe secondary hyperparathyroidism by using novel dose titration; 99 patients completed the study. Hemodialysis patients with secondary hyperparathyroidism were enrolled onto this study, consisting of washout (8 weeks), open-label 1alphaD(2) treatment (16 weeks), and randomized, double-blinded treatment with 1alphaD(2) or placebo (8 weeks). Oral 1alphaD(2) was administered at each hemodialysis session, with doses titrated to achieve target iPTH levels of 150 to 300 pg/mL. Baseline iPTH levels (897 +/- 52 [SE] pg/mL) decreased by 20% +/- 3.4% by week 1 (P: < 0.001) and by 55% +/- 2.9% at week 16; iPTH levels returned to baseline during placebo treatment but remained suppressed with 1alphaD(2) treatment. In 80% of the patients, iPTH level decreased by 70%, reaching the target level in 83% of the patients. Grouping patients by entry iPTH level (<600, 600 to 1,200, and >1,200 pg/mL) showed rapid iPTH suppression in the group with the lowest level; greater doses and longer treatment were required in the group with the highest level. During open-label treatment, serum calcium and P levels were 9.2 +/- 0.84 (SD) to 9.7 +/- 1.05 mg/dL and 5.4 +/- 1.10 to 5.9 +/- 1.55 mg/dL, respectively. During double-blinded treatment, serum calcium levels were slightly greater with 1alphaD(2) than placebo, but P levels did not differ. During double-blinded treatment, 3.26% and 0.46% of serum calcium measurements exceeded 11.2 mg/dL with 1alphaD(2) and placebo, respectively (P: < 0.01); median level was 11.6 mg/dL during hypercalcemia. Intermittent oral 1alphaD(2) therapy effectively suppresses iPTH in hemodialysis patients with secondary hyperparathyroidism, with acceptable mild hypercalcemia and hyperphosphatemia.

Adult↗

Bilateral measurement of femoral bone mineral density.

Both femora were measured on 61 normal adults using dual X-ray absorptiometry (DXA). In a subset of 31 subjects, each femur was scanned once using the conventional leg-positioning device supplied with the densitometer, and once using a new positioning device and software that allowed both legs to be measured simultaneously. In another subgroup (n = 30), subjects were measured three times using the new dual-femur approach to better assess precision error. The data were analyzed for differences owing to the different positioning devices and for differences between right and left sides. The correlation between results with the old and new positioners was high (r > 0.99, standard error of the estimate [SEE] = 0.01-0.02 g/cm(2)). There was no significant difference in the average bone mineral density (BMD) values between the old and new positioner. The precision errors for each femur alone with the dual-femur approach were similar to those reported for the single-femur scans (1 to 2%), but the precision errors for the combined femora were reduced by 30% as expected. The correlation between right and left sides was high (r = 0.94-0.96), and the SEE in predicting one side from the other was moderate for total, trochanteric, and femoral neck BMD (0.05, 0. 05, and 0.06 g/cm(2), respectively). These SEE equate to about 0.5 standard deviation in terms of T-score. Differences in many individual cases between the right and left sides were significantly greater than the precision error. The new dual-femur software and leg positioner allows rapid measurement and analysis of both femora, thereby eliminating the uncertainty between sides.

Absorptiometry, Photon↗

Bone density of the spine and femur in adult white females.

We measured bone mineral density (BMD in g/cm(2)) of the spine (L2-L4) and femur (four regions) in 1472 and 1487 cases, respectively, of ambulatory white women ages 20-79 years in the USA. A DPX densitometer was used in a mobile setting. The BMD values for women up to 69 years corresponded closely with published values for the USA, the UK, and northern Europe; our values were somewhat lower than those from other studies only in women over 70 years. The USA data were combined with data from Europe to give reference curves on about 12,000 subjects. Decreases of BMD with age in women below 50 years were much smaller than in older women (0.2% versus 0.6-1.0% per year). Femoral bone decreased from the neck region, but not the trochanter with age; the decrease of total femur BMD with age was due to loss from the former region. Loss of bone mineral content (BMC in g) from the femur neck and total femur region did not accelerate until after age 50 years, much like the spine. The apparent decrease of BMD in these regions that begins about age 40 actually is due to an increase of bone area. About 20% of USA women aged 50-79 years had BMD levels for the lumbar spine, or for the femur neck, more than -2.5 SD below the average values in young adult women 20-39 years old. Body weight had several times more impact on BMD than height, and in fact, a change of 1 kg in postmenopausal women was commensurate with the effect of a 1-year change in age. Subjects in the lowest quartile of body weight had T-scores that were 1 SD below those in the highest quartile.

Absorptiometry, Photon↗