Display modes for CT colonography. Part II. Blinded comparison of axial CT and virtual endoscopic and panoramic endoscopic volume-rendered studies.

PURPOSE: To determine the sensitivity of radiologist observers for detecting colonic polyps by using three different data review (display) modes for computed tomographic (CT) colonography, or "virtual colonoscopy." MATERIALS AND METHODS: CT colonographic data in a patient with a normal colon were used as base data for insertion of digitally synthesized polyps. Forty such polyps (3.5, 5, 7, and 10 mm in diameter) were randomly inserted in four copies of the base data. Axial CT studies, volume-rendered virtual endoscopic movies, and studies from a three-dimensional mode termed "panoramic endoscopy" were reviewed blindly and independently by two radiologists. RESULTS: Detection improved with increasing polyp size. Trends in sensitivity were dependent on whether all inserted lesions or only visible lesions were considered, because modes differed in how completely the colonic surface was depicted. For both reviewers and all polyps 7 mm or larger, panoramic endoscopy resulted in significantly greater sensitivity (90%) than did virtual endoscopy (68%, P = .014). For visible lesions only, the sensitivities were 85%, 81%, and 60% for one reader and 65%, 62%, and 28% for the other for virtual endoscopy, panoramic endoscopy, and axial CT, respectively. Three-dimensional displays were more sensitive than two-dimensional displays (P < .05). CONCLUSION: The sensitivity of panoramic endoscopy is higher than that of virtual endoscopy, because the former displays more of the colonic surface. Higher sensitivities for three-dimensional displays may justify the additional computation and review time.

Colonic Polyps↗

Display modes for CT colonography. Part I. Synthesis and insertion of polyps into patient CT data.

PURPOSE: To develop and validate a method for the insertion of digitally synthesized polyps into computed tomographic (CT) images of the human colon for use as ground truth for evaluation of virtual colonoscopy. MATERIALS AND METHODS: Spiral CT simulator software was used to generate 10 synthetic polyps in various configurations. Additional software was developed to insert these polyps into volume CT scans. Ten polyps in eight patients were selected for comparison. Three radiologists evaluated whether two-dimensional (2D) CT images and three-dimensional (3D) volume-rendered CT images showed synthetic or real polyps. RESULTS: Edge-response profiles and noise of simulated polyps matched those of native polyps. Frequency distributions of reviewers' responses were not significantly different for synthetic versus real polyps in either 3D or 2D images. Responses were clustered around the response of "unsure" if lesions were real or synthetic. Receiver operating characteristic curves had areas of 0.54 (95% CI = 0.39, 0.68) for 3D and 0.39 (95% CI = 0.25, 0.53) for 2D images, which were not significantly different from random guessing (P = .70 and .28 for 3D and 2D images, respectively). CONCLUSION: Synthetic polyps were indistinguishable from real polyps. This method can be used to generate ground truth experimental data for comparison of CT colonographic display and detection methods.

Adult↗

Suspected acute appendicitis: nonenhanced helical CT in 300 consecutive patients.

PURPOSE: To determine the accuracy of helical computed tomography (CT) without the oral, intravenous, or rectal administration of contrast material in confirming suspected acute appendicitis. MATERIALS AND METHODS: Three hundred consecutive patients referred from the departments of surgery and emergency medicine were examined for suspected acute appendicitis by using thin-section nonenhanced helical CT. All transverse CT scans were obtained in a single breath hold from the upper abdomen (T12 vertebra) to the pubic symphysis with 5-mm collimation and a pitch of 1.6. All scans were obtained without oral, intravenous, or rectal contrast material. Criteria for diagnosis of acute appendicitis included an enlarged appendix (> 6 mm) and periappendiceal inflammation. CT diagnoses were recorded prospectively. Final diagnoses were established with the results of surgical or clinical follow-up or both. RESULTS: There were 110 true-positive diagnoses, 181 true-negative diagnoses (63 of which were an alternative diagnosis correctly established prospectively), five false-negative diagnoses, and four false-positive diagnoses, which yielded a sensitivity of 96%, a specificity of 99%, and an accuracy of 97%. CONCLUSION: Nonenhanced helical CT is a highly accurate technique for diagnosing or excluding acute appendicitis. Developing experience with the technique and understanding the subtleties of interpretation can further improve diagnostic accuracy.

Acute Disease↗

Virtual endoscopy using perspective volume-rendered three-dimensional sonographic data: technique and clinical applications.

OBJECTIVE: We present a technique for obtaining three-dimensional external and virtual endoscopy views of organs using perspective volume-rendered gray-scale and Doppler sonographic data, and we explore potential clinical applications in the carotid artery, the female pelvis, and the bladder. CONCLUSION: Using the proposed methods, radiologists will find it possible to create virtual endoscopy and external perspective views using sonographic data. The technique works well for revealing the interior of fluid-filled structures and cavities. However, expected improvements in computer performance and integration with existing sonographic equipment will be necessary for the technique to become practical in the clinical environment.

Carotid Arteries↗

Computed tomographic angiography: historical perspective and new state-of-the-art using multi detector-row helical computed tomography.

Since its clinical introduction in 1991, volumetric computed tomography scanning using spiral or helical scanners has resulted in a revolution for diagnostic imaging. In addition to new applications for computed tomography, such as computed tomographic angiography and the assessment of patients with renal colic, many routine applications such as the detection of lung and liver lesions have substantially improved. Helical computed tomographic technology has improved over the past eight years with faster gantry rotation, more powerful X-ray tubes, and improved interpolation algorithms, but the greatest advance has been the recent introduction of multi detector-row computed tomography scanners. These scanners provide similar scan quality at a speed gain of 3-6 times greater than single detector-row computed tomography scanners. This has a profound impact on the performance of computed tomography angiography, resulting in greater anatomic coverage, lower iodinated contrast doses, and higher spatial resolution scans than single detector-row systems.

Angiography↗

CT angiography of the abdominal and thoracic aorta.

Evaluation of the abdominal and thoracic aorta is one of the most common indications for CT angiography (CTA). CTA largely has replaced conventional angiography in the assessment of aortic aneurysms and dissections because it provides all the relevant anatomic information at reduced cost, morbidity, and radiation exposure. This article will focus on the technique, interpretation, and pitfalls in the CTA evaluation of the abdominal and thoracic aorta.

Aneurysm↗

CT angiography of the visceral vasculature.

CT angiography (CTA) is a minimally invasive technique that has proven to be clinically useful in evaluating the vasculature of the abdominal viscera. In many instances, the diagnostic information obtained from abdominal CTA is sufficient to avoid the expense and morbidity of conventional angiography. This article reviews the indications, technique, and pitfalls of abdominal CTA with specific emphasis on disorders of the hepatic, splenic, and superior mesenteric arteries and the portal venous system.

Angiography↗

Ultrasound-guided fine-needle aspiration biopsy of thyroid masses.

The purpose of this study was to determine the impact of ultrasound-guided fine-needle aspiration biopsy (USFNA) in the cytological diagnosis of nodular thyroid disease. It remains unclear exactly what role USFNA should play in the cytological diagnosis of nodular thyroid disease. All patients who underwent fine-needle aspiration (FNA) for nodular thyroid disease at Stanford University Medical Center from 1991 to 1996 were included in the study. Histopathologic diagnoses were compared to cytological diagnoses for those patients who underwent surgery. FNA was performed on a total of 497 thyroid nodules. Palpation-guided FNA (pFNA) was performed on 370 nodules, and USFNA was done on 127. The USFNAs were performed for the following reasons: 95 (75%) for nonpalpable or difficult-to-palpate nodules; 14 (11%) for previously failed FNA; and 18 (14%) for incidentally detected nodules. FNA had an unsuccessful biopsy rate of 16% and a sensitivity and specificity of 89% and 69%, respectively. USFNA had an unsuccessful biopsy rate of 7% and a sensitivity and specificity of 100% and 100%, respectively. The cancer yield at surgery for pFNA was 40%, and the cancer yield at surgery for USFNA was 59%. The complementary use of USFNA with pFNA improves the diagnostic approach to nodular thyroid disease. The use of USFNA has increased the cancer yield at surgery and the sensitivity of thyroid biopsy at our institution.

Adult↗

Automated flight path planning for virtual endoscopy.

In this paper, a novel technique for rapid and automatic computation of flight paths for guiding virtual endoscopic exploration of three-dimensional medical images is described. While manually planning flight paths is a tedious and time consuming task, our algorithm is automated and fast. Our method for positioning the virtual camera is based on the medial axis transform but is much more computationally efficient. By iteratively correcting a path toward the medial axis, the necessity of evaluating simple point criteria during morphological thinning is eliminated. The virtual camera is also oriented in a stable viewing direction, avoiding sudden twists and turns. We tested our algorithm on volumetric data sets of eight colons, one aorta and one bronchial tree. The algorithm computed the flight paths in several minutes per volume on an inexpensive workstation with minimal computation time added for multiple paths through branching structures (10%-13% per extra path). The results of our algorithm are smooth, centralized paths that aid in the task of navigation in virtual endoscopic exploration of three-dimensional medical images.

Algorithms↗

Use of color and power Doppler sonography to identify feeding arteries associated with parathyroid adenomas.

OBJECTIVE: The objective of our study was to determine the value of using color and power Doppler sonography to reveal extrathyroidal feeding arteries in the detection of abnormal parathyroid glands. SUBJECTS AND METHODS: Forty-four patients with primary hyperparathyroidism were imaged prospectively with high-resolution gray-scale, color flow, and power Doppler sonography. The presence of extrathyroidal arteries supplying the adenomas was noted. All patients underwent subsequent neck exploration. The locations of the abnormal glands were recorded. RESULTS: At surgery, 51 abnormal parathyroid glands were removed in the 44 patients. Sonography correctly revealed an adenoma in 40 of the 44 patients. Likewise, sonography revealed 42 of the 51 adenomas. Nine false-negative and two false-positive interpretations of the sonograms were made. Thus, overall sensitivity was 83%, specificity was 98%, and accuracy was 94%. Three of the false-negative interpretations were ectopic glands within the superior mediastinum. Excluding these three glands from analysis, the sensitivity for detection of adenomas within the neck was 88%, specificity was 98%, and accuracy was 95%. An extrathyroidal artery leading to a parathyroid adenoma was seen in 35 of the 42 adenomas revealed by sonography. The presence of an extrathyroidal artery leading to an adenoma was found to aid in the detection of an otherwise inconspicuous parathyroid gland in five patients, which improved sensitivity from 73% to 83%. CONCLUSION: Prominent vessels supplying parathyroid adenomas are frequently revealed by color flow and power Doppler sonography. These vessels can serve as "road maps" to abnormal parathyroid glands.

Adenoma↗

Spontaneous intramural small bowel haemorrhage: importance of non-contrast CT.

The purpose of this study was to evaluate the abdominal CT findings in patients with spontaneous intramural small bowel haemorrhage. We retrospectively reviewed the abdominal CT scans of six patients with known intramural small bowel haemorrhage. All of the patients had an underlying coagulopathy. All six patients underwent CT examinations without oral or intravenous contrast media. All six non-contrast CT scans showed hyperattenuation of the involved bowel segments, with thickened and dilated proximal small bowel. Therefore, patients who are clinically at risk for intramural small bowel haemorrhage should undergo a non-contrast CT scan of the abdomen prior to the routine oral and intravenous contrast-enhanced scan. In most cases the non-contrast scan will provide definitive diagnostic information which may not be evident from the contrast-enhanced scan alone.

Adult↗

Unenhanced helical CT for suspected acute appendicitis.

OBJECTIVE: The purpose of this study was to determine the diagnostic accuracy of unenhanced helical CT scans in patients with a suspected acute appendicitis. SUBJECTS AND METHODS: Over a 20-month period, 109 adult patients with suspected acute appendicitis were referred by the emergency department for an unenhanced helical CT scan. Each scan was obtained in a single breath-hold from the T12 vertebral body to the public symphysis using a 5-mm collimation and a pitch of 1.6. No patients were given oral or IV contrast media. The primary CT criteria for diagnosing acute appendicitis was the identification of an appendix with a transverse diameter larger than 6 mm with associated periappendiceal inflammatory changes. The presence of an appendicolith was considered a secondary finding as was isolated periappendiceal inflammation; however, appendicitis was not diagnosed in such patients unless an enlarged appendix was definitely identified. Final diagnoses were established by surgical or clinical follow-up and were compared with the original CT reports. RESULTS: We found 66 true-negatives, 37 true-positives, four false-negatives, and two false-positives that yielded a sensitivity of 90%, a specificity of 97%, a positive predictive value of 95%, a negative predictive value of 95%, and an accuracy of 94%. An alternative diagnosis was established by an unenhanced helical CT scan in 24 patients (22%), which included cecal diverticulitis (seven patients), urinary tract disease (five patients), adnexal pathology (four patients), sigmoid diverticulitis (two patients), small bowel disease (three patients), right lower quadrant tumor (two patients), and an infected dialysis catheter (one patient). CONCLUSION: Unenhanced thin-section helical CT is an accurate, effective technique for diagnosing acute appendicitis.

Acute Disease↗