Search PubMed⌕ Search

Biomedical subjects

R B Donoff

Publications and source records attributed to R B Donoff.

At least 55 records · Page 3Linked to original sources

Nerve regeneration through collagen tubes.

Severe nerve injuries may require microsurgical grafting to span a defect. Introduction of graft material into a highly vascular recipient bed is documented to aid in early regeneration of neuronal blood supply. A silicone rod (SR)-induced fibrovascular sheath was employed to evaluate the regeneration of rat tibial nerve through 2-mm-diameter collagen tubes (CT) or contralateral nerve autografts (AUTO). At first operation, 5 mm of right tibial nerve was resected from 30 retired male breeder Sprague-Dawley rats. Resected nerve was replaced with either a 5 X 2 mm SR or the nerve ends were sutured to the intermuscular fascia. Four weeks later, animals were repaired by replacing the SR with either a CT or a contralateral AUTO from the left tibial nerve. Three months later, EMG testing was performed, and histologic sections were prepared. The EMG latency and the size of the compound action potential for sheathed or non-sheathed CT or AUTO were statistically superior to controls at the 95% confidence level. All other intergroup comparisons of latency and action potential size were statistically insignificant. The proportion of nerve fibers traversing the surgical sites was not influenced by the method of repair or by the presence or absence of sheathing. Tubulized repairs most closely resembled unoperated nerves, and autografted repairs had a large diameter, but much fibrosis, whereas controls displayed immaturity and disorganization. Our observations suggest that there was no difference between repairs performed with or without a vascular pseudosheath. However, CT supported regeneration better than did AUTO repair.

Action Potentials↗

A retrospective analysis of 327 mandibular fractures.

The cases of 372 mandibular fractures are reviewed with respect to treatment, including the indications for extraction of teeth in the line of fracture, complications, and duration of maxillomandibular fixation. It was found that, in general, teeth can be maintained in the line of fracture, although there appeared to be an increased rate of complications associated with fractures when teeth are in the line of injury. In addition, a four-week period of maxillomandibular fixation appears to be an appropriate guideline for treatment.

Fracture Fixation↗

Identification, characterization, and partial purification of mammalian skin wound hyaluronidase.

A recently described mammalian wound hyaluronidase is successfully characterized and partially purified in the current study. Peak enzyme activity occurred on postwound day 7, pH optimum 4.5. Both crude and purified wound enzyme exhibited endoglycosidic activity against hyaluronate and chondroitin-4-sulfate but not against chondroitin-6-sulfate or dermatan sulfate. A 5.3-fold increase in activity was obtained by the DEAE-Sephadex purification technique described. Polyacrylamide gel electrophoresis yielded a single major band near the gel's midrange and one minor band of lesser electrophoretic mobility. These enzyme characteristics support a biochemical analogy between tissue repair in skin and numerous developmental systems and may also provide a simple means for enzymatic differentiation among chondroitin sulfate isomers.

Animals↗

The effect of full-thickness skin grafts on the actomyosin content of contracting wounds.

In evaluating the myofibroblast theory of wound contraction, comparisons were made between grafted and nongrafted 15-day wounds. Pregnant rabbit uteri and normal rabbit skin were used as controls. Small amounts of actin and myosin were present in contracting open wounds but not in noncontracting grafted wounds, which suggests some participation for contractile proteins in wound contraction. The current study refutes the widely accepted contention that wound granulation tissue is as rich as smooth muscle in its contractile protein content.

Adenosine Triphosphatases↗

Use of a miniaturized detector in facial bone scanning.

A high resolution cadmium telluride probe was used in conjunction with standard bone imaging methods in two cases of facial asymmetry. The probe improved localization of the abnormalities and led to rational treatment.

Adult↗