Search PubMed⌕ Search

Biomedical subjects

R B Delamarter

Publications and source records attributed to R B Delamarter.

At least 19 recordsLinked to original sources

Increased fusion rates with cervical plating for three-level anterior cervical discectomy and fusion.

STUDY DESIGN: A retrospective review of all patients surgically treated by a single surgeon with a three-level anterior cervical discectomy and fusion with and without anterior plate fixation. OBJECTIVES: To compare the clinical and radiographic success of anterior three-level discectomy and fusion performed with and without anterior cervical plate fixation. SUMMARY OF BACKGROUND DATA: Previous studies of multilevel cervical discectomies and fusions have shown fusion rates to decrease as the number of surgical levels increases. Anterior cervical plate stabilization can provide more stability and may increase fusion rates for multilevel fusions. METHODS: Over a 7-year period, 59 patients were treated surgically with a three-level anterior cervical discectomy and fusion by the senior author. Forty patients had cervical plates, whereas 19 had fusions with no plates. These patients were observed for an average of 3.2 years. Clinical and radiographic follow-up data were obtained. RESULTS: Of the 59 patients, 14 had a pseudarthrosis (7 in each group). The pseudarthrosis rates were 18% (7 of 40) for patients with plating and 37% (7 of 19) for patients with no plating. Although the nonunion rate for unplated fusions was double that of plated fusions, this difference was not statistically significant. There was no statistically significant correlation between pseudarthrosis and gender, age, level of surgery, history of tobacco use, or previous anterior surgery. The fusion rates were improved with the use of a cervical plate. Inferior clinical results were demonstrated in patients with a pseudarthrosis, regardless of the use of a cervical plate. CONCLUSIONS: The addition of plate fixation for three-level anterior cervical discectomy and fusion is a safe procedure and does not result in higher complication rates. In this study, the pseudarthrosis rate was lower for patients with a cervical plate. However, this difference was not statistically significant. Patients treated with cervical plating had overall better results when compared with those of patients treated without cervical plates. Although the use of cervical plates decreased the pseudarthrosis rate, a three-level procedure is still associated with a high nonunion rate, and other strategies to increase fusion rates should be explored.

Bone Plates↗

Unrecognized durotomy after lumbar discectomy: a report of four cases associated with the use of ADCON-L.

STUDY DESIGN: This report describes four cases of symptomatic cerebral spinal fluid leak after lumbar microdiscectomy where ADCON-L was used. OBJECTIVES: To report that ADCON-L may exacerbate cerebral spinal fluid leak from unrecognized, small dural tears after lumbar discectomy. SUMMARY OF BACKGROUND DATA: ADCON-L is a porcine-derived polyglycan that is used with increasing frequency in spinal surgery. It is advocated to reduce postoperative peridural fibrosis and adhesions. METHODS: Four cases of symptomatic cerebral spinal fluid leak after lumbar microdiscectomy were identified. Information on these patients was obtained by chart review. RESULTS: Three patients had small, inadvertent durotomies that were not appreciated at surgery even with the aid of a microscope. The dural violation in the fourth patient occurred at the previous epidural steroid injection site located on the contralateral side of the laminotomy. CONCLUSION: ADCON-L may inhibit dural healing and exacerbate cerebral spinal fluid leak from microscopic durotomies not recognized at the time of surgery.

Adult↗

A comparison of fusion rates between single-level cervical corpectomy and two-level discectomy and fusion.

A single corpectomy and strut grafting has been proposed as an alternative to performing two-level adjacent discectomies with multiple grafts to produce superior fusion rates. The purpose of this study was to compare the clinical and radiographic success of two-level discectomy and fusion with anterior cervical plate fixation compared with a single-level corpectomy. Fifty-two patients were treated with either a two-level adjacent anterior cervical discectomy and fusion with cervical plating, or by a single-level corpectomy and plate. Thirty-two patients had two-level discectomies, whereas 20 had a single corpectomy and a strut graft (average follow-up was 3.6 years). One patient had a pseudarthrosis from a single-level corpectomy and required subsequent surgery to obtain an osseous union. The fusion rates between the two groups was not statistically significant (p = 0.385). The clinical results of the surgeries were similar between the groups based on Odom's criteria. The addition of cervical plates to either two-level discectomies or single-level corpectomies yielded similar fusion and complication rates.

Adolescent↗

Increased fusion rates with cervical plating for two-level anterior cervical discectomy and fusion.

STUDY DESIGN: A retrospective review of all patients surgically treated with a two-level anterior cervical discectomy and fusion with and without anterior plate fixation by a single surgeon. OBJECTIVES: To compare the clinical and radiographic success of two-level discectomy and the effect of anterior cervical plate fixation. SUMMARY OF BACKGROUND DATA: Prior studies of multisegment fusions have shown decreased fusion rates correlating with the number of increased levels. The use of anterior plates for single-level cervical fusions is controversial. However, their use in multilevel fusions may be warranted because of the increased pseudarthrosis rates. METHODS: Over a 6-year period, 60 patients were treated surgically with a two-level anterior cervical discectomy and fusion by the senior author. Thirty-two patients had cervical plates, and 28 underwent fusions without plates. These patients were followed for an average of 2.7 years. Clinical and radiographic follow-up evaluations were performed. RESULTS: Of the 60 patients, 7 had a pseudarthrosis. The pseudarthrosis rates were 0% for patients with plating and 25% for those with no plating. This difference was statistically significant (P = 0.003). No correlation of pseudarthrosis with gender, age, level of surgery, history of tobacco use, or the presence of prior anterior surgery was found. There was significantly less graft collapse (P = 0.0001) in the patients without plates in whom pseudarthrosis developed (1.4 mm) than in those who had fusions with plates (0.3 mm). The amount of kyphotic deformity of the fused segment was 0.4 degree in patients with plating compared with 4.9 degrees in those without plating who developed a pseudarthrosis (P = 0.0001). CONCLUSIONS: The addition of plate fixation for two-level anterior cervical discectomy and fusion is a safe procedure with no significant increase in complication rates. The pseudarthrosis rates are significantly higher in patients treated without plate fixation. No nonunions occurred in the patients treated with plate fixation. There was significantly less disc space collapse and kyphotic deformity with the plated fusions than with the nonplated fusions, in which a pseudarthrosis developed. The complication rates for plated fusions are extremely low and do not differ from those for nonplated fusions.

Adult↗

Metal debris from titanium spinal implants.

STUDY DESIGN: A prospective study of tissue surrounding spinal instrumentation was performed using histologic and chemical analysis. OBJECTIVES: To identify and quantify the amount of metal debris generated by titanium pedicle screw instrumentation and to evaluate the histologic response in the spinal tissues. SUMMARY OF BACKGROUND DATA: Microscopic metal particles from the soft tissue surrounding joint arthroplasties have been shown to activate a macrophage response that leads to bone resorption and increased inflammation. The use of titanium spinal implants for spine surgery projects the possibility of generating wear debris in the spine. METHODS: Nine patients with titanium instrumentation from a prior lumbar decompression and fusion procedure who were undergoing reoperation were entered into this study. Tissue samples were collected from areas near the pedicle screw-rod junction, the scar tissue overlying the dura, and the pedicle screw holes. Metal levels for titanium were determined by electrothermal atomic absorption spectroscopy, and histologic analysis was performed by light and electron microscopy. RESULTS: Tissue concentrations of titanium were highest in patients with a pseudarthrosis (30.36 micrograms/g of dry tissue). Patients with a solid fusion had low concentrations of titanium (0.586 microgram/g of dry tissue). Standard light microscopy identified metal particles in the soft tissues. Transmission electron microscopy demonstrated macrophages with numerous secondary lysosomes containing electron-dense bodies and collagenous stroma with electron-dense rod-like profiles consistent with metal debris. CONCLUSIONS: Wear debris is generated by the use of titanium spinal instrumentation in patients with a pseudarthrosis. These particles activate a macrophage cellular response in the spinal tissues similar to that seen in surrounding joint prostheses. Patients with a solid spinal fusion have negligible levels of particulate matter.

Biocompatible Materials↗

The outcome of lumbar discectomy in elite athletes.

STUDY DESIGN: An outcomes assessment of 14 elite college athletes who had undergone lumbar disc surgery was performed using the SF-36, a validated questionnaire that assesses quality of life. OBJECTIVES: To determine the outcomes and results of lumbar disc surgery in an elite group of athletes and compare the results with those in the general population and in age-matched control subjects. SUMMARY OF BACKGROUND DATA: Lumbar disc surgery is reported to be a highly successful procedure with excellent results. The outcome in elite athletes has not been assessed and compared with population norms and age-matched control subjects. METHODS: Fourteen athletes from schools in the National Collegiate Athletic Association with a mean age of 20.7, underwent lumbar discectomy for radiculopathy refractory to conservative treatment. Ten had a single-level microdiscectomy, three a two-level microdiscectomy, and one a percutaneous discectomy. Patients were evaluated at a mean follow-up of 3.1 years, underwent a detailed clinical evaluation, and filled out the SF-36 questionnaire. RESULTS: All 14 patients had improvement of pain with elimination of the radicular component, took less medication than before surgery, and returned to recreational sports. Nine patients, all with a single level microdiscectomy, returned to varsity sports. Five athletes prematurely retired from competitive sports because of continued symptoms. Three of the athletes who retired underwent two-level procedures, and one had a percutaneous discectomy. SF-36 scores for bodily pain, physical role, and social and mental health roles were significantly lower in those athletes who retired. Patient scores were also compared with those in a group of noninjured age-and sport-matched college athletes. There were no differences between injured and noninjured athletes, but both groups had scores significantly lower than normal values in an age-matched group for bodily pain, physical role, general health, and social function. CONCLUSIONS: All patients were satisfied with their surgeries, were greatly improved, and were pain free in activities of daily living. For a single-level microdiscectomy, the success rate in elite athletes is excellent, with 90% of athletes able to return to a high level of competition. Two-level disease may be associated with a less favorable outcome.

Activities of Daily Living↗

The publication rates of presentations at major Spine Specialty Society meetings (NASS, SRS, ISSLS).

STUDY DESIGN: A review of all the presentations at three major spine specialty meetings held over a 3-year period. OBJECTIVES: To determine the rate of publication in peer-reviewed journals after presentations at major spine meetings conducted annually by the following three organizations: North American Spine Society (NASS), Scoliosis Research Society (SRS), and International Society for the Study of the Lumbar Spine (ISSLS). SUMMARY OF BACKGROUND DATA: The rate of publication for presentations at national and international meetings has been determined for medical and surgical subspecialties. This rate has been used to judge the quality of the content of the meetings and to determine the validity of the research presentations. METHODS: All presentations either in poster or oral presentation form were entered into a database covering a 3-year period for spine specialty meetings conducted annually by the following three organizations: NASS 1990 to 1992, SRS 1991 to 1993, and ISSLS 1991 to 1993. A computer search for each abstract was performed with the Melvyl Medline Plus database to determine if the abstract had been published in a peer-reviewed journal from 1990 to the end of 1997. Publication rates for presentations at these three meetings were determined over a 3-year period. RESULTS: A total of 1186 abstracts were listed over a 3-year period in the final programs of these three meetings for the years 1991 to 1993 (SRS, ISSLS) and 1990 to 1992 (NASS). Of these 1186 abstracts, 516 were published in peer-reviewed journals, giving an overall publication rate of 43.5%. The publication rates for the three different meetings (NASS, SRS, ISSLS) were similar, with values of 40%, 47%, and 45% respectively. More than 90% of the publications resulting from these meetings were published within a period of 4 years from the data of the meeting. CONCLUSIONS: The publication rates of presentations at three major spine specialty meetings are high and quite comparable with the publication rates of meetings in other medical subspecialties. This reflects the high quality of the meeting programs and validates their selection process.

Congresses as Topic↗

Cervical flexion and extension radiographs in acutely injured patients.

Flexion and extension lateral radiographs of the cervical spine may suggest signs of ligamentous and soft tissue injuries in a potentially unstable spine. However, patients with acute injuries and severe pain and muscle spasms may not be able to move their necks effectively, severely compromising the diagnostic yield of the radiographs. In addition, there are reports of serious neurologic injuries occurring with the use of these radiographs in acutely injured patients. The purpose of this study was to determine the effectiveness and yield of obtaining cervical spine flexion and extension radiographs in the emergency department on acutely injured patients. Review of all patients with cervical flexion and extension radiographs presenting to a Level 1 trauma center was performed. All radiographs were judged based on the adequacy of flexion and extension movement and positive findings indicative of instability by the radiologist in the emergency room. The radiographs of one patient (0.34%) revealed positive findings of instability. Of the 290 flexion and extension radiographs, 97 (33.5%) of them showed such little or inadequate flexion or extension movement that cervical stability could not be assessed. Flexion and extension cervical radiographs should not be obtained routinely in the emergency department because 1/3 of these studies will be inadequate because of pain and muscle spasms experienced by patients. Patients with cervical injuries may not be able to fully flex and extend their necks; this may lead to false reassurance to patients who actually have had an inadequate study to diagnose potential instability.

Acute Disease↗

The effect of cervical plating on single-level anterior cervical discectomy and fusion.

The use of anterior plates for single-level cervical fusions is controversial. Previous studies that evaluated single and multiple-level fusions have shown increased and decreased fusion rates when cervical plates are used. The purpose of this study was to compare the clinical and radiographic success of single-level discectomy performed with and without anterior cervical plate fixation. During a 6-year period, 80 patients were surgically treated with a single-level anterior cervical discectomy. Forty-four patients had cervical plates, whereas 36 had fusions without plates (average follow-up, 2.3 years). The pseudarthrosis rates were 4.5% (2 of 44) for patients with plating and 8.3% (3 of 36) without plating. This difference was not significant (p = 0.653). There was no correlation of pseudarthrosis with sex, age, level of surgery, history of tobacco use, or the presence of previous anterior surgery. The amount of graft collapse for patients with plating was 0.75 mm compared with 1.5 mm for those without a plate (p = 0.026). The amount of kyphotic deformity of the fused segment was 1.2 degrees with plating compared with 1.9 degrees for patients without plating (p = 0.079). Ninety-one percent of the patients with plating had good or excellent results compared with 88% in the group without cervical plates, based on Odom's criteria. The addition of plate fixation for single-level anterior cervical discectomy and fusion is safe and not associated with a significant increase in complication rates. The pseudarthrosis rates are not significantly different when a cervical plate is used.

Adult↗

A comparison of magnetic resonance and computed tomographic image quality after the implantation of tantalum and titanium spinal instrumentation.

STUDY DESIGN: Tantalum- and titanium-based lumbar interbody fusion devices were implanted into two fresh human cadavers, and magnetic resonance and computed tomographic imaging were performed to evaluate adjacent spinal structures and the amount of metallic artifact. OBJECTIVE: The objective of this study was to prospectively compare the preliminary results of magnetic resonance imaging and computed tomography scanning image quality after the implantation of both titanium and tantalum spinal implants. SUMMARY OF BACKGROUND DATA: The availability of tantalum and titanium spinal implants brings theoretical magnetic resonance imaging compatibility along with several other desirable characteristics. The magnetic resonance imaging and computed tomographic imaging of tantalum spinal instrumentation has never been studied previously or compared with titanium instrumentation. METHODS: Titanium and tantalum spinal implants produced for anterior spinal fusion were each placed at two levels in the lumbar spine of two fresh cadaver specimens. Sequential spin echo T1-weighted and T2-weighted magnetic resonance imaging studies and computed tomographic scans were obtained. The resulting images were then graded to describe and compare the behavior of tantalum metal in magnetic resonance imaging and computed tomographic studies. RESULTS: Good T1 and T2 images were obtained that allowed visualization of the neural structures with minimal artifact. The optimal T1 images for tantalum metal were similar in quality to the optimal T1 parameters for titanium metal. T2 images for both tantalum and titanium metal were obtained with similar results for both metals. Gradient echo magnetic resonance imaging scans of both were poorly imaged with a large amount of artifact. Computed tomographic studies of tantalum implants produced a large amount of metal artifact when compared with computed tomographic studies of titanium implants. CONCLUSIONS: High-quality magnetic resonance imaging studies can be obtained after the implantation of both titanium and tantalum spinal instrumentation. Both of the metals produce similar images on magnetic resonance imaging studies with comparable amounts of metallic artifact. High-quality computed tomographic scans of titanium implants can be obtained with minimal distortion secondary to artifact. However, computed tomographic scanning is not the imaging modality of choice for the tantalum spinal implants because of the large amounts of artifact.

Artifacts↗

Intraoperative dermatomal evoked potential monitoring fails to predict outcome from lumbar decompression surgery.

STUDY DESIGN: Thirty-three patients with single-level, unilateral lumbosacral radiculopathy underwent micro-decompression and intraoperative dermatomal evoked potential monitoring. Side-to-side latency asymmetry was calculated. A criteria for "abnormal" was defined. Intraoperative dermatomal evoked potentials were obtained before and after decompression. The changes were correlated with clinical outcome at the 3-month follow-up examination. OBJECTIVES: To determine whether intraoperative dermatomal evoked potential latency asymmetry confirms nerve root compression and whether an improvement of latency asymmetry after decompression predicts a good clinical outcome. SUMMARY OF BACKGROUND DATA: Intraoperative dermatomal evoked potential has been proposed as a test to assess the adequacy of nerve root decompression. Initial reports suggested improvement of dermatomal evoked potential amplitude and latency after decompression. The clinical efficacy is controversial because of its technical difficulty and inherent variation. METHODS: Cervical recording was chosen to reduce the effects of anesthesia. The asymptomatic nerve root was used as a control. Quality of the tracings was determined by evoked potentials-to-noise amplitude ratio. Clinical outcome was based on patient's pain relief and satisfaction. RESULTS: Tracings of acceptable quality were obtained at baseline in 57.6% (19 of 33) of patients. A side-to-side latency asymmetry > 5% was defined as abnormal. Before decompression, 68.4% (13 of 19) of patients had an abnormal dermatomal evoked potential. After decompression, latency asymmetry returned to normal in every patient. Clinical outcome was good or excellent in 13 patients, fair in four patients, and poor in two patients. Dermatomal evoked potential latency improvements were not related to variation in clinical outcome. CONCLUSIONS: Intraoperative dermatomal evoked potential monitoring is technically demanding. Finding reproducible potentials is difficult. More research is necessary before general use of dermatomal evoked potentials for monitoring nerve root decompression.

Adult↗

Experimental spinal fusion with recombinant human bone morphogenetic protein-2 without decortication of osseous elements.

STUDY DESIGN: L4-L5 intertransverse process fusions were produced with 58 micrograms, 230 micrograms, or 920 micrograms of recombinant human bone morphogenetic protein-2 in 20 dogs. Eleven had traditional decortication of posterior elements before insertion of the implant. Nine were left undecorticated. All animals were evaluated 3 months after surgery. OBJECTIVES: To determine whether decortication is a prerequisite for successful fusion in the presence of osteoinductive proteins such as bone morphogenetic protein-2. SUMMARY OF BACKGROUND DATA: Recombinant osteoinductive proteins can induce de novo bone in ectopic soft-tissue sites in the absence of bone marrow elements. Traditional methods for achieving spinal fusion rely on exposure of bone marrow through decortication to facilitate osteogenesis. It is hypothesized that the presence of an implanted osteoinductive protein obviates the need for exposure and release of host inductive factors. METHODS: Recombinant human bone morphogenetic protein-2-induced intertransverse process fusions were performed with and without decortication. Fusion sites were evaluated by computed tomography imaging, high-resolution radiography, manual testing, mechanical testing, and histologic analysis. RESULTS: One hundred percent of decorticated spines and 89% of undecorticated spines were clinically fused by 3 months. Ninety-one percent of decorticated spines and 78% of undecorticated specimens exhibited bilateral transverse process osseous bridging. The only spines that failed to achieve solid bilateral arthrodesis were in the lowest dose group. With the higher two doses, there was histologic evidence of osseous continuity between the fusion mass and undecorticated transverse processes. CONCLUSIONS: There were no statistical differences in clinical and radiographic fusion rates between decorticated and undecorticated sites. With higher doses of recombinant human bone morphoganetic protein-2, there was little histologic distinction between fusions in decorticated versus undecorticated spines.

Animals↗

Occlusion of the left iliac artery after retroperitoneal exposure of the spine.

This case report describes a rare but treatable complication of anterior lumbar surgery. The patient underwent a revision anterior fusion from L2 to S1. Complete thrombotic occlusion of the left iliac artery developed in the patient. Prompt recognition of vascular compromise and arterial bypass of the iliac system lead to excellent functional recovery.

Aged↗

MR parameters for imaging titanium spinal instrumentation.

The presence of stainless steel implants along a spinal column causes extreme distortion of data collected by magnetic resonance (MR) imaging. The recent availability of titanium alloy spinal instrumentation systems suggests that MR imaging evaluation of the instrumented spine may now be feasible. The objective of this study was to perform MR imaging examinations on spines implanted with titanium alloy instrumentation and to determine the parameters that yield the highest quality images with the least amount of artifact. A titanium pedicle screw construct was implanted into the lumbar spine of two fresh human cadaveric specimens. Sequential spin echo MR scans were performed using various TE and TR ratios on each intact specimen. The resultant images were quantitatively graded for clarity of adjacent soft tissue and osseous structures. Excellent T1- and T2-weighted images with well-defined neural structures were obtained with minimal artifact. The optimal T1-weighted image was obtained with TE = 16 and TR = 500-600, whereas the optimal T2-weighted image was obtained with TE = 60 and TR = 1,300-1,600. By using appropriate settings, high-quality MR scans in both the T1- and T2-weighted modes can be obtained with minimal metal artifact.

Artifacts↗

Effective doses of recombinant human bone morphogenetic protein-2 in experimental spinal fusion.

STUDY DESIGN: Nineteen dogs underwent L4-L5 intertransverse process fusions with either 58 micrograms, 115 micrograms, 230 micrograms, 460 micrograms, or 920 micrograms of recombinant human bone morphogenetic protein-2 carried by a polylactic acid polymer. A previous study (12 dogs) compared 2300 micrograms of recombinant human bone morphogenetic protein-2, autogenous iliac bone, and carrier alone in this model. All fusions subsequently were compared. OBJECTIVES: To characterize the dose-response relationship of recombinant human bone morphogenetic protein-2 in a spinal fusion model. SUMMARY OF BACKGROUND DATA: Recombinant osteoinductive morphogens, such as recombinant human bone morphogenetic protein-2, are effective in vertebrate diaphyseal defect and spinal fusion models. It is hypothesized that the quality of spinal fusion produced with recombinant human bone morphogenetic protein-2, above a threshold dose, does not change with increasing amounts of inductive protein. METHODS: After decortication of the posterior elements, the designated implants were placed along the intertransverse process space bilaterally. The fusion sites were evaluated after 3 months by computed tomography imaging, high-resolution radiography, manual testing, mechanical testing, and histologic analysis. RESULTS: As in the study using 2300 micrograms of recombinant human bone morphogenetic protein-2, implantation of 58-920 micrograms of recombinant human bone morphogenetic protein-2 successfully resulted in intertransverse process fusion in the dog by 3 months. This had not occurred in animals containing autograft or carrier alone. The cross-sectional area of the fusion mass and mechanical stiffness of the L4-L5 intersegment were not dose-dependent. Histologic findings varied but were not related to rhBMP-2 dose. Inflammatory reaction to the composite implant was proportional inversely to the volume of the fusion mass. CONCLUSIONS: No mechanical, radiographic, or histologic differences in the quality of intertransverse process fusion resulted from a 40-fold variation in dose of recombinant human bone morphogenetic protein-2.

Animals↗

Distractive properties of a threaded interbody fusion device. An in vivo model.

STUDY DESIGN: Twenty sheep underwent anterior lumbar interbody fusions with either a threaded titanium interbody fusion device (cage, n = 8), autogenous iliac crest dowel graft (autograft, n = 6), or interbody decortication only (sham, n = 6). Two sheep had misplaced cages and were excluded. Sheep were killed after 6 months. OBJECTIVES: To determine whether this model is useful for examining the distractive and fixation properties of interbody fusion cages. SUMMARY OF BACKGROUND DATA: Interbody fusion cages are used in anterior lumbar interbody fusion procedures to provide immediate intersegmental fixation and to distract and preserve interbody height. The process of physiologic anchorage by bone ingrowth into such devices is under investigation. METHODS: Sheep were radiographed immediately after surgery and 2, 4, and 6 months after surgery. Interbody distraction and angulation were measured with a digital photo image analyzer at each time point. After the sheep were killed, stiffness to flexion, extension, and lateral bending moments were measured. Twelve untreated cadaver spines were also tested for comparison. RESULTS: After surgery, interbody distraction successfully occurred in cage and autograft-implanted sites. Loss of interbody height ensued, however, in all groups during the first 2 months. Percentage loss of height was lowest in cage sites. By 6 months, only cage sites remained distracted beyond normal. Fusions in all groups were stiffer than untreated spines. Autograft sites were stiffer than cage sites to lateral bending. Sham sites were stiffer than cage and autograft sites to flexion, but this likely resulted from complete intervertebral collapse. CONCLUSION: Despite early subsidence, interbody fusion cages successfully distracted and preserved interbody spaces. This model is useful for investigating methods of improving distraction and stabilization.

Animals↗

Variables affecting pedicle screw plate fixation of an unstable L3-L4 defect.

Fresh frozen human cadaveric spinal specimens (T8-S1) were subjected to pure flexion extension bending moment and pure axial torque loadings while intervertebral rotations were recorded at the L3-L4, L2-L3, and Ll-L2 discs. A standardized unstable defect was created at the L3-L4 disc, and loading tests were repeated after application of bilateral Steffee plates in 2 configurations: a short plate with 2 pedicle screws (spanning the defect) and a longer plate with 3 pedicle screws (spanning the defect and 1 disc above). Each plating configuration was tested in the unlocked state (nuts compressing the plate down onto the spine) and locked state (nuts above and below the plate tightened against each other to clamp the plate to the screws). Locking the plates to the screws had no effect on any intervertebral rotation at any disc level. Use of a longer plate that also spanned the disc above the defect offered no advantage in controlling flexion extension rotations at the defect site. However, mean torsional rotation at the defect site with the 3-screw plate was approximately 50% of the mean for a 2-screw plate. Extension and torsional rotations at the L2-L3 disc (1 level above the defect site) were unaffected by application of a 2-screw plate; flexion rotation at this level increased slightly after plating. All motions at the L2-L3 disc were reduced (as would be expected) when the 3-screw plate spanned this uninjured disc. Plating the defect had no effect on disc rotations at the L1-L2 disc (2 levels above the fracture site).

Aged↗

Pyogenic vertebral osteomyelitis and postsurgical disc space infections.

The presentation and clinical course for hematogenous vertebral osteomyelitis and postoperative discitis is presented. The treatment is primarily conservative care in the form of immobilization and parenteral antibiotics. The indications for surgery are rare and should be reserved for patients resistant to treatment or with septic course, abscess formation, or neurologic deficits. In these cases, the infectious process has generally involved the adjacent vertebrae or the neural elements. Surgery usually involves an anterior approach. The principles of surgical treatment involve debridement of necrotic tissue, decompression of neural elements, and stabilization of the spine. The outcome of patients with vertebral osteomyelitis and secondary discitis in general is favorable when appropriate treatment is rendered. Extension of the infection to the spinal canal in the form of an epidural abscess is also reviewed.

Abscess↗