Search PubMed⌕ Search

Biomedical subjects

R Autschbach

Publications and source records attributed to R Autschbach.

At least 37 records · Page 2Linked to original sources

A new intracardiac microaxial pump: first results of a multicenter study.

As coronary artery bypass grafting (CABG) surgery in the beating heart technique is progressing, new devices have been developed to overcome hemodynamic instabilities while tilting the heart for exposure of back wall vessels. A new device for in heart biventricular intracorporeal circulation was applied in 42 patients undergoing CABG surgery (Group 1). The control group consisted of 38 patients operated on using a conventional cardiopulmonary bypass setup (Group 2). The study protocol of the prospective, randomized multicenter study was approved by the local ethics committees. Patients were included following inclusion criteria and patient informed consent. Mean age, procedure time, mean arterial pressure (MAP), and hemolysis by means of plasma free hemoglobin (fHb) were assessed preoperatively, perioperatively, on postoperative Days 1 to 3, at discharge, and at a 3 month follow-up. The mean age was 62.1 (range 59-74) years (Group 1), 62.7 (range 48-72) years (Group 2); procedure time was 112 min +/- 31.9 min (Group 1), 137.4 min +/- 36.2 min (Group 2); and 2.3 +/- 0.6 (Group 1), 2.2 +/- 0.7 (Group 2), vessels were revascularized. The flow on pump was 3.7 (2.5/4.4) L/min (Group 1), 4.9 (3.6/6.2) L/min (Group 2) which resulted in a MAP of 69.8 (4.0/143) mm Hg (Group 1), 58.3 (5.3/94) mm Hg while assessing the vessels of the back wall. Hemolysis defined by fHB was lower than 20 mg/dl at all times pre- and postoperatively. Intraoperative maximum values were up to 100 mg/dl in 4 patients (2 in Group 1 and 2 in Group 2). Body mass index was 26.4 +/- 2.6 (Group 1), 27.9 +/- 3.2. New York Heart Association Class was II to III in both groups. There were no pump related life threatening or severe adverse events. Beating heart procedures with ICC can be reliably and safely achieved. As the device is easy to use, it may deserve a more widespread use in the future.

Aged↗

[Robotic surgery--surgical and anesthesiologic implications].

Because of the restricted freedom of movement inherent in endoscopic standard instruments wholly endoscopic heart surgery has not been possible up to now. The development of such techniques was especially hindered by the rib cage. Now the precision which is imperative for bypass surgery or valve reconstruction is made possible by telemanipulator systems. Preconditions for this method are cardiopulmonary bypass-techniques which allow a cardioplegic cardiac arrest with closed chest and extensive hemodynamic monitoring which enables the anesthesiologist to make exact diagnoses without having a direct view on the heart. After an extensive experimental phase a telemanipulation system is successfully in use since May 1998 in the Cardiac Center in Leipzig.

Anesthesia↗

Acute aortic dissection during pregnancy.

We review the cases of two women with acute aortic dissection during their last trimester of pregnancy who underwent aortic root replacement. One patient with type A dissection had to undergo surgical intervention immediately, and required extracorporal membrane oxygenation for four days. The other patient with a pre-diagnosed Marfan's disease had suffered a type B dissection and had to undergo emergency operation after developing a type A dissection nine days later.

Adult↗

Computer-enhanced "robotic" cardiac surgery: experience in 148 patients.

OBJECTIVE: A computer-enhanced instrumentation system was used in 148 patients to minimize access in cardiac surgical procedures. METHODS: The da Vinci telemanipulation system (Intuitive Surgical, Mountain View, Calif) provides a high-resolution 3-dimensional videoscopic image and allows remote, tremor-free, and scaled control of endoscopic surgical instruments with 6 degrees of freedom. By April 2000, the system had been used in 131 patients for coronary artery bypass grafting and 17 patients for mitral valve repair. In the coronary bypass group, the system was used in one of three ways: (1) to take down the internal thoracic artery followed by a minimally invasive direct coronary bypass procedure (n = 81); (2) to perform the anastomosis between the internal thoracic artery and the left anterior descending coronary artery in standard-sternotomy coronary bypass (n = 15); or (3) for total endoscopic coronary artery bypass grafting to anastomose the left internal thoracic artery to the left anterior descending on the arrested heart (n = 27) or the beating heart (n = 8). In 17 patients with nonischemic mitral valve insufficiency the mitral valve was repaired. Closed-chest cardiopulmonary bypass with cardioplegic arrest (Port-Access technique; Heartport, Inc, Redwood City, Calif) was used for arrested-heart total endoscopic coronary bypass and mitral valve repair. RESULTS: The da Vinci system allows for precise tissue handling and enables the endoscopic performance of cardiac surgical tasks that require a high degree of dexterity (coronary anastomosis, mitral valve repair). No technical mishaps have occurred. The internal thoracic artery was successfully taken down in 79 of 81 patients in the group undergoing minimally invasive coronary bypass and, after a steep learning curve, is currently performed in less than 40 minutes. The postoperative patency rate is 96.3%. Total endoscopic coronary bypass was completed in 22 of 27 cases with 95.4% patency as demonstrated by angiography at 3 months' follow-up. Closed-chest endoscopic beating-heart bypass grafting was successfully performed in 2 out of 8 patients with the use of a new endoscopic stabilizer. In the group having mitral valve repair, primary endoscopic computer-enhanced repair was successfully completed in 14 of 17 patients; three others had to be changed to a standard endoscopic technique, including 1 who required valve replacement. At 3 months' follow-up, 1 additional patient underwent early reoperation for recurrent mitral insufficiency. Overall early and late mortality in this cohort of 148 patients was 2.0% and was not related to the use of the system. CONCLUSION: In conclusion, computer-enhanced endoscopic cardiac surgery can be performed safely in selected patients. Internal thoracic artery takedown is now routinely performed with good results. Total endoscopic coronary bypass is feasible on the arrested heart but does not offer a major benefit over the minimally invasive direct approach because cardiopulmonary bypass is still required. The early clinical experience with closed-chest beating-heart bypass grafting outlines the limitations of this approach despite some procedural success.

Animals↗

[Patient-adapted valve selection: biological vs. mechanical heart valve replacement in aortic valve diseases].

Since the first aortic valve replacement performed by Harken in 1960, the operation of aortic valve disease by replacing the native valve with a heart valve prosthesis has become one of the most frequently performed procedures in cardiac surgery. For valve replacement there are biological (xenografts and homografts) and mechanical heart valve prostheses available. When choosing the most suitable prosthesis the limited durability of a biological prosthesis and the risks of lifelong anticoagulation for a mechanical prosthesis have to be balanced. In this article the indication for operation of aortic valve stenosis and aortic regurgitation are discussed first. Based on the literature of the last 2 years the advantages and disadvantages of mechanical and biological heart valve prostheses (xenograft, homograft and ROSS procedure) are discussed. In addition rarely used techniques like aortic valve reconstruction are presented. Due to the fact that a biological prosthesis has a durability of 12-15 years and the risk of bleeding complications under anticoagulation grows with increasing age, the choice of a biological prosthesis can be recommended from the age of 65 years. Results of long-term studies at to whether this limit can be diminished by using a stentless biological prosthesis have to be awaited.

Aged↗

Prospectively randomized comparison of different mechanical aortic valves.

BACKGROUND: The aim of this prospectively randomized study was to evaluate the hemodynamic and functional outcomes after aortic valve replacement with 3 different bileaflet mechanical valves. METHODS AND RESULTS: Three hundred consecutive patients were randomly assigned to receive ATS (n=100), Carbomedics (n=100), or St Jude Medical Hemodynamic Plus (n=100) mechanical aortic valve replacement. There were no significant differences regarding patient age (average 61+/-8 years), body surface area (1.9+/-0.2 m(2)), left ventricular function (ejection fraction 0.59+/-0.17), and presence of aortic stenosis (90%, 89%, and 91%), respectively. All patients had postoperative as well as 6-month and 1-year follow-ups that included transthoracic echocardiography. Multivariate statistical analysis was performed. Implanted valve sizes were comparable at 24+/-2 (ATS), 23.7+/-1.6 (CM), and 23.6+/-1.9 (SJMHP) mm (NS). At 1-year follow-up, the following incidence of events was noted: death 3/1/1, all non-valve related; stroke 0/1/1; trivial transvalvular incompetence 3/3/2; paravalvular leak 2/3/2; and reoperation 0/1/1, respectively (NS). Transvalvular flow velocities were 2.5/2.6/2.4 m/s postoperatively (P:=0.03) and 2.4/2.4/2.3 m/s at 6-month follow-up, respectively (NS). There was a significant decrease in left ventricular mass for all patients but no significant differences among the groups. CONCLUSIONS: There are no clinically relevant differences among the tested bileaflet aortic valves. Regardless of valve type, there was a low complication rate. On the basis of these findings, all 3 bileaflet prostheses are well suited for aortic valve replacement.

Aortic Valve↗

Humoral immune response during coronary artery bypass grafting: A comparison of limited approach, "off-pump" technique, and conventional cardiopulmonary bypass.

BACKGROUND: The introduction of limited approaches to the heart and the avoidance of cardiopulmonary bypass (CPB) aim to reduce the invasiveness of CABG by decreasing the systemic release of inflammatory cytokines, such as tumor necrosis factor (TNF)-alpha, interleukin (IL)-6, and IL-8, as well as the anti-inflammatory agent IL-10. This study compares the humoral immune response in patients undergoing CABG with standard, minimally invasive, and "off-pump" techniques. METHODS AND RESULTS: Thirty patients were divided into 3 operative groups: full sternotomy approach plus CPB (group A); full sternotomy approach, off pump (group B); and limited left anterior thoracotomy, off pump (group C). Plasma levels of TNF-alpha receptors p55 and p75, IL 6, IL-8, and IL-10 were taken at baseline, during CPB, and at 4, 24, and 48 hours and 6 days after surgery. A significant increased release of activated complement factors C5a and C3d, IL-8, and IL-10 was observed in patients subjected to CPB (group A) during the initial period and for a short time after perfusion (P:<0.05). TNF-alpha receptors p55 and p75 showed a prolonged elevation (up to 48 hours) in the CPB group compared with the 2 off-pump groups. IL-6 showed no different release among the 3 surgical groups throughout the entire period. There was no significant difference in any parameter measured in relation to the type of operative approach. CONCLUSIONS: There is an inflammatory, as well as an anti-inflammatory, response during CABG that is related to the general surgical trauma. The release of immune mediators is enhanced by the use of CPB during various perioperative and postoperative phases. The type of operative approach did not influence this immune response.

Aged↗

Pain is significantly reduced by cryoablation therapy in patients with lateral minithoracotomy.

BACKGROUND: In minimally invasive cardiac surgery use of a lateral minithoracotomy is associated with early postoperative rehabilitation but also relatively high pain levels during the first 3 postoperative days. Cryoablation therapy was evaluated prospectively. METHODS: From April 1999 until September 1999, 57 patients underwent lateral minithoracotomy for mitral valve operation (n = 18) or minimally invasive direct coronary artery bypass grafting (n = 39). Intraoperatively, patients were randomly assigned to cryoablation or intercostal application of local anesthetic agents. A standardized questionnaire was used for prospective pain assessment on postoperative days 1 to 7. RESULTS: From postoperative day 1 to 7 pain levels declined in all groups. Overall pain levels were significantly lower in the cryo group than in the control group (p < 0.0001, GLM). According to diagnoses, pain levels were significantly lower after MIDCABG and cryo versus control; after mitral valve operation they were lower in the cryo group and almost reached significance. CONCLUSIONS: Cryoablation is easy to perform and leads to a significant reduction in pain and lower request for additional pain medication after lateral minithoracotomy in minimally invasive cardiac operation.

Anesthetics, Local↗

Cerebral microemboli during minimally invasive and conventional mitral valve operations.

BACKGROUND: Intraoperative cerebral microembolism may cause postoperative neurologic damage. The aim of this study was to determine the frequency of cerebral microembolic signals (MES) during minimally invasive surgery (MIS) and conventional (conv.) mitral valve operations and to determine the association of MES with various stages of the operation. METHODS: Intraoperative computer-aided transcranial Doppler measurements were performed to detect cerebral microemboli in 21 patients undergoing MIS and in 14 patients undergoing conv. mitral valve operation. We calculated the mean embolic rate for three time periods: P1, start of the operation until aortic clamping; P2, aortic clamping until clamp removal; and P3, declamping until end of surgery. RESULTS: There was no significant difference in the total number of detected cerebral MES between both patient groups (MIS 1,014+/-753, conv. 937+/-519; NS). In both groups, the highest number of MES were detected during the third time period when the heart regained effective ejection (MIS 875+/-746, conv. 680+/-462; p > 0.5). CONCLUSIONS: Transcranial Doppler was useful to detect cerebral microemboli in MIS and conv. mitral valve operation. We found no increased risk of cerebral microembolism during the minimally invasive method compared with the conventional technique.

Cardiopulmonary Bypass↗

Combined stentless mitral valve implantation and radiofrequency ablation.

BACKGROUND: The aim of this study was to evaluate the results of combined stentless mitral valve (SMV) replacement and intraoperative radiofrequency ablation for chronic atrial fibrillation (IRAAF) to restore physiologic hemodynamic function. METHODS: Since July 1998 12 patients (72+/-4 years, 10 women, mitral stenosis/mitral incompetence 8/4, NYHA 3.3+/-0.4, CI 1.8+/-0.5) had SMV implantation and received additional IRAAF by inducing continuous left atrial lesion lines from the MV annulus to all four pulmonary veins and to the atriotomy. RESULTS: The flexible SMV was implanted at the papillary muscles and at the annulus using a conventional (n = 6) or a minimally invasive approach (n = 6). Sinus rhythm was successfully restored in 10 of 12 patients with 6- and 12-months' follow-up; 2 required DDD-pacemaker implantation. However, in the early postoperative period several interventions including medical treatment (sotalol or amiodarone) in 9 and electrical cardioversion in 7 patients was required. Two patients required reinterventions: 1 cardioversion and 1 amiodarone medication after 3 and 6 months, respectively. At echocardiography the SMV demonstrated good hemodynamic function and atrial contraction. CONCLUSIONS: Restoration of physiologic cardiac function by SMV implantation and IRAAF is advantageous and no further anticoagulation is required.

Aged↗

The revival of surgical treatment for isolated proximal high grade LAD lesions by minimally invasive coronary artery bypass grafting.

BACKGROUND: Percutaneous coronary angioplasty (PTCA) and stent implantation have become the first-line intervention for patients with isolated proximal LAD-lesions. Minimally invasive direct coronary artery bypass surgery (MIDCAB) has recently been developed to reduce surgical invasiveness for single LAD revascularization. This study focus on the question whether MIDCAB could be an alternative treatment for isolated proximal LAD lesions. METHODS: Starting in 1996, MIDCAB was performed in 618 patients. Angiography was performed before discharge and repeated after 6 months at follow-up examination. In an ongoing randomized trial 150 patients with an indication for treatment of a LAD lesion have been included to compare the mid-term outcome after PTCA (n=79) vs. MIDCAB (n=71). RESULTS: In 618 MIDCAB procedures 30-day mortality was 0.6%, perioperative myocardial infarction rate was 1.6%. The conversion rate to sternotomy was 3.4%. The learning curve was demonstrated by a patency rate of 96.0% in 1997, 98.0% in 1998 and 99.1% in 1999, respectively. At 6 months patency rate was 94.4% in 1997 and 97.0% in 1998. The rate of severe stenosis >75% dropped from 5.4% in 1997 to 3.4% in 1998. The over all rate of reinterventions was 5.6%. The preliminary result of the randomized trial revealed a difference in the number of perioperative adverse events, 11.4% in the MIDCAB group vs. 6.3% in the PTCA group (P<0.05). At 6 months follow-up 88. 7% of the MIDCAB patients were free from angina vs. 58.2% of the PTCA patients (P<0.02). Restenosis and a positive stress test was diagnosed in 27.9% of the PTCA patients vs. 8.4% of the MIDCAB patients (P<0.02). Reintervention was necessary in 27.9% of the patients after PTCA vs. 8.4% of the patients after MIDCAB. CONCLUSION: MIDCAB is a safe and effective but technically demanding procedure. Perioperative adverse events may be expected, but early as well as mid-term patency rate are good. When compared to PTCA, the freedom from angina and the need for additional revascularization procedures after 6 months is statistically better for patients having MIDCAB surgery. Thus, MIDCAB is considered a valuable alternative for isolated proximal high grade LAD lesions.

Adult↗

Total endoscopic computer enhanced coronary artery bypass grafting.

OBJECTIVE: In an effort to minimize access in coronary artery bypass (CAB) surgery, a total endoscopic approach using computer enhanced technology was developed. METHODS: By July 1999 the da Vinci telemanipulation system (Intuitive Surgical, Mountain View, CA) was used in 66 patients with coronary artery disease. In 12 patients undergoing routine coronary artery bypass grafting (CABG) (group 1) the internal thoracic artery (ITA) to left anterior descending artery (LAD) anastomosis was performed remotely using the system. In 32 patients (group 2) endoscopic dissection of the ITA was performed followed by a conventional minimally invasive direct coronary artery bypass (MIDCAB) operation. In 22 patients (group 3) the complete operation was performed endoscopically through 4 ports (total endoscopic coronary artery bypass, TECAB). Port-Access cardiopulmonary bypass with cardioplegic arrest was used for TECAB. RESULTS: In group 1 the time for performing the ITA to LAD anastomosis was 17 +/- 10 min. Mean graft flow was 38 +/- 25 ml/min. One anastomosis leaked and was repaired manually. In group 2 in 31/32 patients (96%) the ITA harvest was successfully performed with the system at mean of 61 +/- 27 min. There was a substantial learning curve associated with ITA take-down. In one patient a dissection caused insufficient free ITA graft flow which necessated additional vein grafting. Postoperative angiography demonstrated graft patency in all cases. In the TECAB group, the operation could be completed through four ports in 18 of the 22 patients (82%) with operating times in the range 220-507 min. In four patients, elective conversion to a minithoracotomy was required due to failure to identify the LAD (1), bleeding from the anastomosis (1), grafting of a diagonal branch (1) and torsion of the pedicle (1). One patient required reoperation for bleeding from an ITA side-branch. Median intubation time was 13 h and stay on ICU and hospitalization were 20 h and 7 days, respectively. A 3-month follow-up angiography revealed patent grafts in all TECAB patients. CONCLUSION: Endoscopic ITA harvesting and performing of arterial anastomoses can be safely performed with the da Vinci system. TECAB is possible on the arrested heart with good functional results. However, a substantial learning curve has to be overcome which is reflected in long operation times and an initial significant conversion rate.

Cardiopulmonary Bypass↗

Primary left-atrial leiomyosarcoma.

A patient rapidly developing right heart failure due to a left-atrial leiomyosarcoma was admitted for surgery. A large tumor, originating in the left atrium and extending into both pulmonary veins, was removed. Histology showed an unusual epitheloid appearance of many cells with occasional mitoses and a strong immunexpression to desmin and actin. Six months later heart failure developed again: computer tomography demonstrated regrowth of the tumor in the left atrium with invasion of the mediastinum and the para-aortal lymph nodes. The patient died shortly after.

Aged↗

Developments in robotic cardiac surgery.

A new generation of surgical telemanipulation systems has helped to overcome the limitations of conventional endoscopic tools. These computer-enhanced instrumentation systems provide tremor filtering and motion scaling and allow dexterous manipulations in confined spaces through ports or trocars. Using these systems, total endoscopic coronary artery bypass grafting both on the arrested and on the beating heart has been performed successfully. Repair of mitral valves as well as atrial septal defects has also been performed remotely through 1 centimeter incisions. Despite some early procedural success, operating times are prolonged and a number of conversions have been reported. Currently, the use of telemanipulation systems is restricted to selected patients and limited to very few indications. Further refinements in telemanipulator technology as well as integration of image-based navigation systems may expand the use of computer-enhanced instrumentation systems in the near future.

Cardiac Surgical Procedures↗

Comparison of On-X and SJM HP bileaflet aortic valves.

BACKGROUND AND AIM OF THE STUDY: The study aim was to evaluate the hemodynamic function after aortic valve replacement (AVR) using the On-X valve, in comparison with St. Jude Medical (SJM) HP bileaflet valves. METHODS: Patients received either the On-X (n = 20) or SJM HP prosthesis (n = 20) for AVR. The control (SJM HP) group was computer-matched with the On-X group for age, gender, aortic stenosis as underlying disease, body surface area, NYHA functional class, left ventricular size, mass and function, transvalvular pressure gradients and cardiac index. Mean implanted valve size was 23.5 mm (three 21 mm, ten 23 mm, six 25 mm, one 27 mm) in both groups. All patients underwent postoperative, and six- and 12-month follow up echocardiography. RESULTS: The intra- and postoperative course was uneventful in all patients. There were no significant differences in cross-clamp and cardiopulmonary bypass times, intensive care unit stay, in-hospital stay and postoperative NYHA functional class. Two patients (both On-X) had paravalvular leakage postoperatively and at follow up. Five patients in the control group had additional myocardial revascularization. Transvalvular flow velocities were 2.38 +/- 0.3 versus 2.38 +/- 0.4 m/s (p = NS) postoperatively, and 2.08 +/- 0.2 versus 2.22 +/- 0.3 m/s (p = NS) at one year follow up for On-X and SJM HP valves, respectively. Maximum pressure gradients were 16.9 +/- 6.0 versus 18.5 +/- 8.0 mmHg (p = NS) postoperatively and 14.0 +/- 3.7 versus 16.5 +/- 5.7 mmHg (p = NS) at one year for the two valve types, respectively. A relatively pronounced transvalvular reflux was diagnosed for On-X valves. CONCLUSION: At one year after implantation, the On-X bileaflet prosthesis is equally suited for AVR in comparison with the 'standard' therapy (SJM HP). Exact sizing requires some experience. There were no significant differences between the two prostheses with regard to hemodynamic parameters either postoperatively or at one-year follow up. Long-term prospective randomized studies yet have to be carried out.

Aortic Valve↗