Search PubMed⌕ Search

Biomedical subjects

R Assmann

Publications and source records attributed to R Assmann.

15 recordsLinked to original sources

Transverse envelope dynamics of a 28.5-GeV electron beam in a long plasma.

The transverse dynamics of a 28.5-GeV electron beam propagating in a 1.4 m long, (0-2)x10(14) cm(-3) plasma are studied experimentally in the underdense or blowout regime. The transverse component of the wake field excited by the short electron bunch focuses the bunch, which experiences multiple betatron oscillations as the plasma density is increased. The spot-size variations are observed using optical transition radiation and Cherenkov radiation. In this regime, the behavior of the spot size as a function of the plasma density is well described by a simple beam-envelope model. Dynamic changes of the beam envelope are observed by time resolving the Cherenkov light.

Journal Article↗

X-ray emission from betatron motion in a plasma wiggler.

The successful utilization of an ion channel in a plasma to wiggle a 28.5-GeV electron beam to obtain broadband x-ray radiation is reported. The ion channel is induced by the electron bunch as it propagates through an underdense 1.4-meter-long lithium plasma. The quadratic density dependence of the spontaneously emitted betatron x-ray radiation and the divergence angle of approximately (1-3)x10(-4) radian of the forward-emitted x-rays as a consequence of betatron motion in the ion channel are in good agreement with theory. The absolute photon yield and the peak spectral brightness at 14.2-keV photon energy are estimated.

Journal Article↗

Measurements of radiation near an atomic spectral line from the interaction of a 30 GeV electron beam and a long plasma.

Emissions produced or initiated by a 30-GeV electron beam propagating through a approximately 1-m long heat pipe oven containing neutral and partially ionized vapor have been measured near atomic spectral lines in a beam-plasma wakefield experiment. The Cerenkov spatial profile has been studied as a function of oven temperature and pressure, observation wavelength, and ionizing laser intensity and delay. The Cerenkov peak angle is affected by the creation of plasma, and estimates of neutral and plasma density have been extracted. Increases in visible background radiation, consistent with increased plasma recombination emissions due to dissipation of wakefields, were simultaneously measured.

Journal Article↗

Right ventricular function assessed by thermodilution technique during apnea and mechanical ventilation.

OBJECTIVES: To evaluate strategies for thermodilution-based measurement of cardiac output and right ventricular (RV) ejection fraction and to assess the effects of controlled mechanical ventilation in patients. Furthermore, to compare strategy-associated reproducibility with reference values obtained during long-term apnea. DESIGN: Crossover trial in patients; reference values from apneic animals. SETTING: University ICU and physiology laboratory. PATIENTS: Six consecutive male ICU patients (48 to 70 yrs) after major abdominal vascular surgery. ANIMALS: two adult female sheep. INTERVENTIONS: Three ventilatory rates (8, 16, and 24 cycles/min) and 15-sec periods of apnea were selected for measurements in patients. In animals, continuous apnea was achieved with extracorporeal CO2 removal and apneic oxygenation. MEASUREMENTS: Measurements were performed using an appropriate pulmonary artery catheter and an ejection fraction/cardiac output computer prototype. The thermal indicator was injected automatically at four defined points of the ventilatory cycle, but triggered manually during apnea. MAIN RESULTS: At 8 cycles/min, there was a wide mean range of cyclic variable modulation, with a coefficient of variation of 11.6% and 23.2% for cardiac output and RV ejection fraction, respectively. Allowing for ventilatory phase or changing from 8 to 16 cycles/min reduced errors by half. Combining both procedures resulted in a coefficient of variation of 4.7% and 6.6% for cardiac output and RV ejection fraction, respectively. The best coefficient of variation values obtained during 15 secs of apnea in patients approached those variations in experimental apnea (coefficient of variation of 2.1% and 4.5% for cardiac output and RV ejection fraction, respectively). CONCLUSIONS: At low ventilatory rates, best results are achieved by averaging four phase-selected measurements. One-point measurements were less accurate and random point measurements less reproducible.

Aged↗

A video-angiometer for simultaneous and continuous measurement of inner and outer vessel diameters. Technical report.

A system is described for continuously measuring vessel diameters. It bases on the evaluation of video signal differences of a video camera which are induced by light intensity differences (grey levels) caused by the vascular wall structures. The system is electronically linear, automatically measuring and in addition eyeball controlled by the human sensor: the inaccuracy does not exceed the 5% level.

Blood Vessels↗

Structural differences in the mesentery microcirculation between normotensive and spontaneously hypertensive rats.

The mesentery preparation of normotensive rats (NR) (Pcarotis97 +/- 4 mm Hg) and of spontaneously hypertensive rats (SHR) (161 +/- 2 mm Hg) of comparable age (20 +/- 3 weeks) was used to study morphological changes of the microvasculature in established hypertension. The arterioles, classified according to their branching order, had an increased inner diameter in SHR (by 20%). The smooth muscle hypertrophy decreased with smaller vessel size. Pre- and postcapillary vessels were shorter in SHR than in NR by 17 to 35%. The number of these vessels related to the number of the feeding terminal arterioles was found to be reduced by nearly 50% in SHR. The data suggest a lowered arteriolar flow resistance in individual vessels of the hypertensive group concomitant with a gradually disappearing smooth muscle hypertrophy towards the capillary bed. The elevation of the resistance to blood flow in the hypertensive rats is obviously caused by a reduced number of resistance vessels, as seen in the mesentery vascular bed. Similar results were obtained in the true capillaries, which showed greater inner diameters (SHR vs NR:7.2 micron vs 6.4 micron), shortened lengths (141 vs 170 micron) and a reduced number (50 vs 70). Red cell velocity in true capillaries did not differ (0.51 mm/s vs 0.49 mm/s). Arterio-venous shunt vessels were described with an average inner diameter of 11 micron. In SHR these vessels were shorter (424 vs 654 micron) and increased in number. The 'hydraulic hindrance' of AV-shunt vessels and true capillaries together was decreased in SHR; the surface area did not differ between SHR (55.7 . 10(3) micron2) and NR (50.1 . 10(3) micron2) suggesting no major variation in the exchange functions.

Animals↗

Intravital measurement of arteriolar pressure and tangential wall stress in normotensive and spontaneously hypertensive rats (established hypertension).

Under intravital conditions, intravascular pressures of mesenteric resistance vessels were measured in normotensive (NR, mean blood pressure 92 mm Hg) and spontaneously hypertensive rats (SHR, 161 mm Hg) being elevated over all by about 75%; the tangential wall stress (sigma = p.r/h; p represents the intravascular pressure and r/h the ratio of internal radius to wall thickness) was found to be increased by 120-140% in SHR.

Animals↗