Aerosol delivery in neonatal ventilator circuits: a rabbit lung model.

The benefits of inhaled therapy in ventilated neonates are recognized, but the reliability of drug delivery in nebulizer-ventilator circuits is uncertain. We quantified the effect of changing variables. Twenty-three freshly killed rabbits (1.15-1.9 kg) were ventilated via a tracheostomy by a pressure-limited, time-cycled ventilator (Neovent). A radioaerosol of 99Tcm pertechnetate from an Ultravent nebulizer (Mallinkrodt) was fed into the proximal ventilator tubing. Two 3-minute nebulizations at "standard settings" were followed by 2 at altered pressure, frequency, gas flow, I:E ratio, or position of the nebulizer in the circuit. Each nebulization was followed by a 3-minute gamma camera image and total deposited radioactivity was measured in excised lungs and trachea. Images demonstrated good peripheral aerosol deposition. At standard settings, lung deposition averaged 2.8% of the aerosol released. This was decreased markedly by reducing tidal volume (ventilator pressures) and residence time of aerosol (I:E ratio). Reduced gas flow decreased deposition slightly, presumably by increased particle size and marginally reduced tidal volume. Deposition did not change with increased frequency; increased minute ventilation was offset by decreased residence time of the aerosol. We conclude that the Ultravent nebulizer can be used to nebulize drugs in a standard neonatal circuit, although the dose delivered is small. Tidal volume and aerosol residence time are important determinants of aerosol delivery.

Animals

Lead in paint.

Explore the source record for details and available documents.

Humans

A comparison of radiography and radioisotope scanning in the detection of Paget's disease and in the assessment of response to human calcitonin.

In eight patients with symptomatic Paget's disease, radiographs and radioisotope bone scans have been compared before treatment by high dose synthetic human calcitonin (CIBA 47175-Ba) and three months and 12 months later. In six patients quantitative radioisotope scans allowed calculation of relative radioactivity in normal bone, Paget's disease and bone adjacent to osteoarthritic joints. Comparison of radiographs and scans showed 69 sites diagnosed as Paget's disease on both examinations; nine sites showed radiographic changes of Paget's disease but had negative radioisotope scans and two sites were abnormal on the scan but radiologically normal. One of these two reverted towards normal during treatment with calcitonin. Comparison of analogue scans done at three months and 12 months with initial scans showed diminished uptake in Paget's disease compared with normal bone, and quantitation showed this was due to decreased absolute uptake in Paget's disease and a slight increase in normal bone. Osteoarthritic bone showed no significant response to calcitonin.

Aged