Search PubMed⌕ Search

Biomedical subjects

R Albiero

Publications and source records attributed to R Albiero.

At least 37 records · Page 2Linked to original sources

Effectiveness and complications of vascular access closure devices after interventional procedures.

BACKGROUND: Vascular closure devices are designed to obtain a fast hemostasis of the vascular access site after diagnostic and interventional procedures. This result should be obtained with a low incidence of complications. METHODS: A retrospective, non-randomized study was performed to evaluate the success rate and vascular complications associated with the use of two different vascular sealing devices [Angio-Seal (Daig Corporation, Minnetonka, Minnesota) and Prostar (Perclose, Inc., Redwood City, California)] after interventional procedures. RESULTS: Eight-hundred and twenty-seven devices were used (245 Angio-Seal and 582 Prostar). Angio-Seal success rate was 92% with a 2.5% rate of vascular complications; Prostar success rate was 89% with a 3.4% rate of vascular complications. Multivariate logistic regression analysis identified advanced age (p < 0.05) and lower weight (p < 0.05) as independent predictors of vascular complications associated with Angio-Seal use, while diabetes (p < 0.05) was found to be a predictor of vascular complications in the Prostar group. Abciximab use and larger sheath size were not associated with an increased probability of vascular complications. CONCLUSION: Angio-Seal and Prostar obtain a fast vascular access hemostasis after interventional procedures, with a low incidence of major vascular complications.

Angioplasty, Balloon, Coronary↗

European high-activity (32)P radioactive stent experience.

Brachytherapy by implantation of a radioactive stent is an alternative approach to catheter-based systems to reduce restenosis. The pilot clinical trials using 32P radioactive b-emitting stents at low-to-intermediate activity (0.5Eth 3.0 mCi) showed that restenosis at 6 months was not different from that of currently available non-radioactive stents. The evaluation of the efficacy in reducing restenosis of radioactive stents with higher activities (3Eth 24 mCi) started in Europe (Milan, Rotterdam and Vienna) between 1998 and 1999. In the Milan and Rotterdam experience, 32P radioactive stents with an activity of 3Eth 12 mCi demonstrated a reduction of intra-stent restenosis to < 4%. However, a high-edge restenosis > 30% was observed in the first 1Eth 3 mm outside the stent margins. This edge effect might be due to a low dose of radiation at the stent margins combined with systematic balloon injury in the reference segments. The hypothesis that a further increase in stent activity (12Eth 21 mCi) associated with a reduced balloon injury outside the stent could solve the problem of edge restenosis was not confirmed by the Milan experience; edge restenosis still occurred in 26% of the lesions treated by a single 32P radioactive stent, even if a nonaggressive stent implantation strategy was used. Two approaches under investigation to solve the problem of edge restenosis are: 1) lengthening the stent with a non-radioactive stent (cold-ends stent) to prevent negative remodeling; and 2) extending the area of irradiation beyond the balloon-injured area by an increased activity at the stent ends (hot-ends stent).

Blood Vessel Prosthesis Implantation↗

Contemporary percutaneous treatment of saphenous vein graft stenosis: immediate and late outcomes.

PURPOSE: The aim of this study was to evaluate the immediate and long-term outcomes following percutaneous treatment of an unselected series of saphenous vein graft (SVG) lesions. METHODS AND RESULTS: Consecutive interventions on 129 saphenous vein graft lesions in 101 patients were reviewed. Stents were implanted in 114 lesions (88%), which included the use of polytetrafluoroethylene-covered stents in 22 lesions (17%) and abciximab in 20 patients (20%). Angiographic success was achieved in 125 lesions (97%). In-hospital major adverse cardiac events (MACE) occurred in 11 patients (11%), with myocardial infarction being the most frequent event. Treatment of degenerated SVG lesions and SVG lesions with larger reference diameters correlated with the incidence of in-hospital MACE [odds ratio (OR) = 7.69 and 2.65, respectively; 95% confidence interval (CI) = 1.80Eth 32.8 and 0.99Eth 7.10, respectively)]. Clinical follow-up was achieved in all patients at 25 +/- 21 months. Successful revascularization to all three distributions of the major coronary arteries negatively correlated [relative risk (RR) = 0.43; 95% CI = 0.20Eth 0.92)], while treatment of a degenerated SVG positively correlated (RR = 1.92; 95% CI = 1.05Eth 3.51) with the occurrence of follow-up MACE. A final effective blood supply to the anterior wall and a higher left ventricular ejection fraction was found to negatively correlate with the occurrence of follow-up death (RR = 0. 20 and 0.61, respectively; 95% CI = 0.06Eth 0.60 and 0.41Eth 0.90, respectively). CONCLUSION: Treatment of SVG lesions continues to be associated with a high incidence of myocardial infarction, particularly in cases of degenerated SVG lesions. An effective blood supply to the anterior wall and a higher left ventricular ejection fraction were protective for the occurrence of death during the follow-up period.

Aged↗

Coronary stenting beyond standard indications. Immediate and follow-up results.

BACKGROUND: Coronary stent has become an accepted treatment modality for selected indications. However, the literature shows diverse results when indications for coronary stenting are different from those tested in large randomized trials. The purpose of this study was to determine immediate and follow-up clinical and angiographic results in patients treated with coronary stenting for indications not specifically tested in large randomized trials. METHODS: Coronary stents were implanted in a total of 2060 lesions (1757 patients) in seven groups with expanded indications: left main coronary lesions, calcified lesions, small vessels (< 3 mm in size), small vessels with diffuse disease, large vessels with diffuse disease, and bifurcation lesions treated with stents in both branches or with one stent implanted only in the major branch. Stents were implanted using high balloon pressure for final inflation and in most cases with intravascular ultrasound. Clinical follow-up was achieved in 96% of patients at a mean time of 12+/-7 months. RESULTS: Primary success (range 89-96%) and acute complications (range 5.7-13%) were comparable in all groups. At follow-up, the mortality rate was highest in the group of left main stenting (12.5%) but 20% of these patients had coronary stenting on non-elective basis. The restenosis rates ranged between 16-43%. The restenosis rate was highest in the group of bifurcation lesions with stent implantation in both vessels leading to a major adverse cardiac event (MACE) rate of 62% in this group. However, the survival rate at 1 and 2 years in the overall study group was 97 and 96%, and the event free survival was 76 and 74%, respectively. The procedure-related predictors of MACE were: final intravascular ultrasound result, use of stents with non-slotted tube morphology, final stent percent stenosis, and vessel size. CONCLUSIONS: Coronary stenting beyond standard indications is feasible, with acceptable primary success and complication rates. However, the overall MACE rates were relatively high (34-62%), in particular for the indication of bifurcation lesions with stents implanted in both vessels.

Age Factors↗

Comparison of immediate and follow-up results of the short and long NIR stent with the Palmaz-Schatz stent.

The intrinsic characteristics of a stent including stent length may affect both procedural success and long-term outcome. The present study evaluated the immediate and follow-up results after implantation of the short and long NIR stent and compared these results with the Palmaz-Schatz stent. Between July 1995 and December 1996, stenting with a 16-mm NIR stent (NIR-16), a 32-mm NIR stent (NIR-32), or a Palmaz-Schatz stent (PS) was performed in 68, 57, and 155 lesions, respectively. There were no significant differences in the incidences of delivery failure (PS, 2.6%: NIR-16, 4.4%; NIR-32, 5.3%; p = NS) and procedural success (PS, 92%; NIR-16, 93%; NIR-32, 93%; p = NS) among the 3 groups. The reference vessel diameter was smaller in lesions with a 32-mm NIR stent than in those with a Palmaz-Schatz stent (PS, 3.14+/-0.58, NIR-16, 3.00+/-0.50; NIR-32, 2.90+/-0.47 mm; p <0.05). The lesion length was longer in lesions with a 32-mm NIR stent than in those with a Palmaz-Schatz or a 16-mm NIR stent (PS, 8.9+/-5.0; NIR-16, 11.0+/-4.1; NIR-32, 26.1+/-9.7 mm; p <0.01). After the procedure, the lesions with a 32-mm NIR stent had a smaller minimal lumen diameter than those with a Palmaz-Schatz stent (PS, 3.17+/-0.61; NIR-16, 2.99+/-0.51; NIR-32, 2.89+/-0.49 mm; p <0.01). At follow-up, a smaller minimal lumen diameter was observed in lesions with a 32-mm NIR stent than in those with a Palmaz-Schatz or a 16-mm NIR stent (PS, 2.32+/-0.98; NIR-16, 2.25+/-0.80; NIR-32, 1.68+/-0.79 mm; p <0.01). Restenosis rates were 16.5% in lesions with a Palmaz-Schatz stent, 13.3% in those with a 16-mm NIR stent, and 47.4% in those with a 32-mm NIR stent (p <0.01). Although stent delivery and procedural success of a long NIR stent were acceptable, the restenosis rate of a long NIR stent was high compared with a short NIR stent or a Palmaz-Schatz stent.

Adult↗

Prevention of distal embolization during saphenous vein graft lesion angioplasty. Experience with a new temporary occlusion and aspiration system.

BACKGROUND: Repeat coronary artery bypass graft surgery (CABG) is associated with a high morbidity and mortality, rendering percutaneous treatment of saphenous vein graft (SVG) lesions an attractive alternative. However, percutaneous interventions of degenerated SVGs carries high risk of distal embolization. METHODS AND RESULTS: This study reports our initial experience with the PercuSurge GuardWire, a new device developed to prevent embolization during treatment of degenerated SVG. This device consists of a 190-cm-long, hollow 0.014-in guidewire with a central lumen connected to a distal occlusion balloon. A dedicated inflation device (the MicroSeal Adapter) was used to inflate the distal balloon and maintain complete lumen occlusion during balloon dilatation and stent implantation. A monorail aspiration catheter, connected to a vacuum syringe, was used to evacuate atherosclerotic and thrombotic debris. Angioplasty with stent implantation was performed in 15 degenerated SVGs (18 lesions). Procedural success was achieved in all patients with normal postprocedure flow (Thrombolysis in Myocardial Infarction grade 3). No distal embolization was observed. There were no major in-hospital adverse clinical events, including Q-wave or non-Q-wave myocardial infarction, emergency CABG, or death. All patients were asymptomatic at discharge. CONCLUSIONS: This preliminary series supports the feasible use of the PercuSurge GuardWire for retrieval of plaque debris and prevention of embolization in degenerated SVGs. The good tolerance of temporary occlusions without angiographic or clinical evidence of distal embolization represents encouraging early findings.

Aged↗

Does the specific intravascular ultrasound criterion used to optimize stent expansion have an impact on the probability of stent restenosis?

Intravascular ultrasound (IVUS) imaging has been used to optimize stent implantation in coronary arteries, but the criteria used were chosen on an empiric basis. The aim of this study was to determine whether any of these criteria have an independent role in predicting the probability of freedom from restenosis. The study population consisted of 425 patients (496 lesions) who underwent angiographically successful IVUS-guided stenting. Five IVUS criteria were studied: (1) intrastent minimal lumen cross-sectional area (ISMLCSA) > or =9 mm2; (2) ISMLCSA (> or =9 mm2 and > or =80% of average reference lumen cross-sectional area [CSA]); (3) ISMLCSA > or =90% of average reference lumen CSA; (4) ISMLCSA > or =90% of distal reference lumen CSA; and (5) ISMLCSA > or =55% of average reference vessel CSA. These criteria were met in 33%, 29%, 68%, 82%, and 69% of lesions, respectively. Angiographic follow-up was performed in 335 of 421 eligible patients (80%) at 5.3 +/- 2.7 months. An absolute ISMLCSA > or =9 mm2 was associated with the lowest restenosis, but this criterion was primarily achieved in large vessels. The only criterion that was associated with higher probability of freedom from restenosis independently from vessel size was an ISMLCSA > or =55% of average reference vessel CSA. Therefore, when IVUS is used to guide stent implantation an effort should be made to achieve the largest lumen safely possible. An ISMLCSA > or =55% of the average reference vessel CSA seems to be the most appropriate criterion in terms of frequency of achievement and in terms of increasing the probability of freedom from restenosis.

Coronary Angiography↗

Stenting after optimal lesion debulking (sold) registry. Angiographic and clinical outcome.

BACKGROUND: Coronary stenting has reduced restenosis in focal de novo lesions, but its impact has been less pronounced in complex lesion subsets. Preliminary data suggest a role for plaque burden in promoting intimal hyperplasia after stent implantation. The aim of this study was to test the hypothesis that plaque removal with directional atherectomy before stent implantation may lower the intensity of late neointimal hyperplasia, reducing the incidence of in-stent restenosis. METHODS AND RESULTS: Seventy-one patients with 90 lesions underwent directional atherectomy before coronary stenting. Intravascular ultrasound-guided stenting was performed in 73 lesions (81%). Clinical success was achieved in 96% of patients. Procedural complications were as follows: emergency bypass surgery in 1 patient (1.4%), who died 2 weeks later; Q-wave myocardial infarction in 2 patients (2.8%); and non-Q-wave myocardial infarction in 8 patients (11.3%). None of the patients had stent thrombosis at follow-up. Angiographic follow-up was performed in 89% of eligible patients at 5.7+/-1.7 months. Loss index was 0.33 (95% CI, 0.26 to 0.40), and angiographic restenosis was 11% (95% CI, 5% to 20%). Clinical follow-up was performed in all patients at 18+/-3 months. Target lesion revascularization was 7% (95% CI, 3% to 14%). CONCLUSIONS: Directional atherectomy followed by coronary stenting could be performed with good clinical success rate. Also, these data point to a possible reduction in angiographic restenosis and a significant reduction in the need for repeated coronary interventions. Therefore, a randomized clinical trial seems appropriate to test the validity of this approach.

Aged↗

Coronary artery stenting in the elderly: short-term outcome and long-term angiographic and clinical follow-up.

OBJECTIVES: This study sought to compare the short- and long-term outcomes of elderly patients undergoing coronary artery stenting with those of younger patients and to determine the long-term clinical outcome and survival of elderly patients post stent implantation. BACKGROUND: Elderly patients undergoing coronary revascularization are considered a high-risk group. Few data exist that relate the results of stenting in treating coronary artery disease in the elderly population. METHODS: All elderly patients >75 years of age who underwent coronary artery stenting between March 1993 and July 1997 (n=137) at our center were compared to the patients <75 who underwent coronary artery stenting during the same time period (n=2,551). Long-term clinical follow-up and survival were determined for the elderly group. RESULTS: Elderly patients presented with lower ejection fractions (54% vs. 58%, p=0.0001), more unstable angina (47% vs. 28%, p=0.0001), and more multivessel disease (78% vs. 62%, p= 0.0001) than younger patients. These older patients had higher rates of procedure related complications including procedural myocardial infarction (MI) (2.9% vs. 1.7%, p=0.2), emergency CABG (3.7% vs. 1.4%, p=0.04), and death (2.2% vs. 0.12%, p=0.0001). Angiographic follow-up, obtained in both groups, demonstrated significantly higher restenosis rates in the elderly versus younger patients (47% vs. 28%, p=0.0007). Longer term clinical follow-up, which was obtained only in the elderly group, showed that at a mean follow-up period of 12 months post coronary stenting, elderly survival free from death, MI, revascularization and angina was 54% and that their overall survival was 91%. Subanalysis of the elderly patients who died showed much higher incidence of combined unstable angina (80%), prior MI (60%), lower ejection fraction (46%), multivessel disease (100%) and complex lesions (100%) than the overall group. CONCLUSIONS: Elderly patients who undergo coronary artery stenting have significantly higher rates of procedural complications and worse six month outcomes than younger patients, especially those who present with combined unstable angina, history of MI, EF < 50%, multivessel disease and complex lesions. Overall survival in the elderly population at 12 months postcoronary artery stenting was 91% and event-free survival was 54%.

Aged↗

Persistent High Restenosis After Local Intrawall Delivery of Long-Acting Steroids Before Coronary Stent Implantation.

OBJECTIVE: This pilot study was performed to evaluate the feasibility and safety of intrawall delivery of long acting steroids before stent implantation, testing the efficacy of this treatment in reducing intimal hyperplasia in lesions at high risk for restenosis. METHODS: In 24 patients (40 lesions) local intrawall drug delivery of methylprednisolone acetate, using a new catheter device, was attempted before elective stent implantation. Treated lesions were compared to a matched control group. RESULTS: Lesions were classified AHA/ACC type C in 47% of cases, had a mean lesion length of 13.6 +/- 9.1 mm, and a mean vessel diameter of 2.85 +/- 0.44 mm. In 9 cases (25%) chronic total occlusions were treated. Methylprednisolone acetate (mean 60 +/- 23 mg) was delivered in 36 lesions (21 patients; delivery success 90%) in the remaining 4 lesions (10%) the delivery device did not cross the lesion. After drug delivery 46 stents were implanted (1.2 stent/lesion; stented segment length 30.1 +/- 18.8 mm) using high pressure for stent expansion (mean 16.4 +/- 3.1 atm). Intracoronary ultrasound guidance was used in 64% of cases. Procedural and in-hospital complications were: Two non Q wave myocardial infarctions (8%) and one (3%) subacute stent thrombosis. Angiographic follow-up was obtained in all 36 treated lesions (100%) and the angiographic restenosis rate (³ 50% diameter stenosis) was 39%. A reduction of the incidence of restenosis compared to the matched control group was not observed. CONCLUSIONS: Long acting steroids could be delivered locally with high success and low complication rates. The restenosis rate remained high in a subset of unfavorable lesions with high risk for restenosis.

Journal Article↗

Comparison of immediate and intermediate-term results of intravascular ultrasound versus angiography-guided Palmaz-Schatz stent implantation in matched lesions.

BACKGROUND: Intravascular ultrasound (IVUS) provides more precise information than angiography about vascular dimensions. This information is used by some centers to optimize intracoronary stent implantation. There are no direct comparisons of the effects on restenosis of optimal IVUS-guided versus angiography-directed high-pressure stenting. METHODS AND RESULTS: Lesions of patients who had a 6-month angiographic follow-up study were eligible for matching. From 445 consecutive lesions treated by Palmaz-Schatz (P-S) stenting guided by IVUS (IVUS group) in Milan, 173 lesions were individually matched with 173 of 476 consecutive lesions treated by P-S stenting directed by angiography (Angio group) in Hamburg. Lesions were selected by a computerized program according to baseline clinical, angiographic, and procedural variables. Immediate and 6-month angiographic results were retrospectively compared, distinguishing an "early phase" from a "late phase." This distinction was based on the more aggressive dilation strategy with larger balloons and more demanding IVUS criteria for optimal stent expansion used in Milan in the early phase. In both phases, a larger minimum lumen diameter (MLD) immediately after stenting and after 6 months was achieved in the IVUS group than in the Angio group. In the early phase, the dichotomous restenosis rate was lower in the IVUS group than in the Angio group (9.2% versus 22.3%; P=.04). In the late phase, there was no difference in restenosis between the groups (22.7% versus 23.7%; P=1.0). CONCLUSIONS: In matched lesions treated with high-pressure stenting, IVUS guidance achieved a larger MLD than angiographic guidance. However, in the IVUS group, the restenosis rate was lower only in the early phase, when balloons larger than currently used were selected to maximize the stent lumen area.

Adult↗

Results of a consecutive series of patients receiving only antiplatelet therapy after optimized stent implantation. Comparison of aspirin alone versus combined ticlopidine and aspirin therapy.

BACKGROUND: Previous studies have shown that stents can be inserted in coronary arteries of patients who are subsequently treated safely with antiplatelet therapy only (ticlopidine and/or aspirin) with a low incidence of stent thrombosis, provided that stent expansion is adequate and there are no other flow-limiting lesions present. However, it is unknown whether ticlopidine combined with aspirin is superior to aspirin alone in preventing stent thrombosis. METHODS AND RESULTS: From March 1993 through July 1995, 801 consecutive patients assigned to receive either aspirin therapy alone (ASA, 264 patients, 348 lesions) or a combination of ticlopidine and aspirin (TIC-ASA, 537 patients, 737 lesions) after a successful stent insertion, in most accomplished with intravascular ultrasound guidance, were evaluated retrospectively. At 1 month, there was no difference in the ASA group compared with the TIC-ASA group in the rate of any stent thrombosis (1.9% versus 1.9%; P = 1), subacute stent thrombosis (1.9% versus 1.3%; P = .5), cumulative major adverse clinical events (1.9% versus 2.0%; P = 1), and peripheral vascular complications (0.5% versus 0.2%; P = .3). Medication side effects that required termination of antiplatelet therapy occurred only in 1.9% of patients in the TIC-ASA group (P = .04). CONCLUSIONS: At 1-month clinical follow-up, stent thrombosis and other adverse clinical outcomes were not significantly different between the ASA and TIC-ASA groups. Medication side effects occurred only in patients treated with ticlopidine. These results provide further evidence of the safety of treatment with antiplatelet therapy only after optimal stent implantation and support the efficacy of aspirin alone in preventing stent thrombosis.

Angioplasty, Balloon↗

[The exercise test with atropine].

BACKGROUND: Exercise testing remains the most accessible and widely used technique for the detection of coronary artery disease (CAD) and for the assessment of its severity. Clinical usefulness of the simple exercise test is limited by poor sensitivity and imperfect specificity. Many patients referred for diagnostic stress testing cannot achieve an adequate increase in heart rate due to lack of motivation, poor physical condition, or medications. Atropine increases the heart rate and therefore myocardial oxygen consumption, and might improve the diagnostic accuracy of exercise testing, either reducing the number of non-diagnostic examinations, or increasing the positivity of the test in patients with non severe coronary disease. METHODS: One-hundred-seventy-two consecutive patients (144 males and 28 females, age 58 +/- 8 years) with suspected coronary artery disease underwent exercise testing and coronary angiography. Exercise testing was considered positive in the presence of ST segment depression > or = 0.10 mV horizontal or downsloping, > or = 0.15 mV upsloping, or in the presence of ST elevation without Q waves. The test was considered negative in the absence of significant ST depression or elevation if the exercise heart rate was > 85% of age-predicted maximum, non-diagnostic if the heart rate was < 85%. In 148 patients (86%) coronary angiography showed CAD (> 70% luminal reduction in at least one major vessel), in 24 patients (14%) non significant CAD or angiographically normal coronary arteries (NoCAD). Exercise testing was positive in 134 patients (78%: 85% in CAD, 33% in NoCAD), negative in 13 patients (8%: 3% in CAD, 38% in NoCAD), non-diagnostic in 25 patients (14%; 12% in CAD, 29% in NoCAD). The sensitivity was 85%, specificity was 38%, and diagnostic accuracy 78%. In the 25 patients with non-diagnostic test (18 CAD, 7 NoCAD) the exercise was repeated 30-90 minutes later, immediately after i.v. injection of 1-2 mg of atropine, and was stopped at the same workload of the index test. RESULTS: The atropine-exercise test was well tolerated and accomplished in all cases. The maximal heart rate (139 +/- 11 vs 121 +/- 11) and the double product (25,308 +/- 4082 vs 22,166 +/- 3569) were significantly greater after atropine. The increase of the maximal heart rate improved the detection of the electrocardiographic signs of exercise-induced myocardial ischemia only in CAD patients. In the 18 CAD patients the atropine-exercise test was positive in 8, negative in 5, non-diagnostic in 5. In the 7 NoCAD patients the atropine-exercise test was positive in 1, negative in 6. The test remained non-diagnostic only in 3% of patients. The sensitivity of the test with atropine was 91%, specificity was 63%, and diagnostic accuracy 87%. CONCLUSIONS: The addition of atropine to exercise testing, which causes further chronotropic stress to the myocardium, is well tolerated and safe, and improves the diagnostic accuracy of the test for the detection of coronary artery disease in patients who cannot achieve an adequate exercise heart rate. The combination with atropine increases the utility and the cost-effectiveness of exercise testing.

Atropine↗

[Acute myocardial ischemia: ECG or echocardiography? Considerations on a clinical case].

We present a clinical case and a review of the literature on the usefulness of two-dimensional echocardiography for the diagnosis of acute myocardial ischemia in patients presenting with chest pain but without diagnostic electrocardiographic changes. The case refers to a patient admitted a few hours after an episode of prolonged chest pain without diagnostic electrocardiographic changes, but with a severe wall motion abnormality assessed by two-dimensional echocardiogram. The electrocardiogram obtained 24 hours after admission showed giant negative T waves in the anterior chest leads when the patient was asymptomatic and the echocardiogram showed disappearance of wall motion abnormalities. Coronary angiography demonstrated a thrombotic occlusion of the left anterior descending coronary artery, that was treated by transluminal angioplasty. The considerations refer to the following points: 1) a substantial portion of patients with chest pain examined in the emergency room has initially a normal or non-diagnostic electrocardiogram; 2) in these patients two-dimensional echocardiography provides a highly sensitive and specific noninvasive tool for the establishment of the correct diagnosis of acute myocardial ischemia when a severe wall motion abnormality is shown; 3) if successive amelioration of regional myocardial dysfunction is assessed, this was probably due to stunned myocardium; 4) it is probably not correct to consider T wave inversion as the electrocardiographic equivalent of myocardial stunning, as the two phenomena are not chronologically correlated.

Acute Disease↗