Search PubMed⌕ Search

Biomedical subjects

R A Walsh

Publications and source records attributed to R A Walsh.

At least 163 records · Page 9Linked to original sources

The effects of calcium-entry blockade on left ventricular systolic and diastolic function.

The hemodynamic properties of the calcium entry-blocking agents result principally from the inhibition of transcellular calcium flux in the myocardium and in vascular smooth muscle. The composite effect(s) of these compounds on cardiovascular function derive from a complex interplay between their direct (myocardial depression) and indirect (afterload reduction by peripheral arterial vasodilation, reflex sympathetic stimulation) actions. While qualitatively similar, the currently available agents (diltiazem, nifedipine, verapamil) differ considerably in relative negative inotropic, vasodilator, and reflex properties. The hemodynamic actions of a particular calcium blocker also critically depend on the baseline cardiocirculatory status. Current information regarding these issues from basic and clinical investigations is reviewed.

Animals↗

First-pass anger camera radiocardiography: biventricular ejection fraction, flow, and volume measurements.

First-pass (FP) right and left ventricular ejection fraction results were compared with equilibrium radiocardiographic (ER) measurements, and FP left ventricular ejection fraction (LVEF) values were compared with biplane contrast angiographic (CA) measurements in 13 patients with and seven patients without regurgitant valvular disease. Regurgitant fractions were calculated from differences between the FP right and left ventricular stroke volumes. Ejection fractions determined by FP were precise (mean CV = 9.6% RVEF, 13.4% LVEF). Mean LVEF by FP and ER were essentially identical, and both were lower than by CA. LVEF(FP) correlated with LVEF by ER and CA (r = 0.88, p less than 0.001). Mean RVEF by both FP and ER were also correlated (r = 0.82, p less than 0.001). There was correlation between FP (corrected) and CA left ventricular stroke (r = 0.77), end-diastolic (r = 0.88), and end-systolic (r = 0.91) volumes, but underestimates were noted when uncorrected flows were used (r = 0.52-0.71). The FP regurgitant fraction measurements separated the patients with regurgitant valvular disease from those without and agreed well with CA grading of regurgitation.

Blood Volume↗

Quantification of left-ventricular regional dyssynergy by radionuclide angiography.

To determine whether variables obtained from Fourier analysis of gated equilibrium radionuclide angiographic (RNA) images can detect and quantify changes in left-ventricular (LV) regional wall motion induced by transient ischemia, 11 chronically instrumented dogs were simultaneously studied with hemodynamic measurements and RNA during control, left circumflex (LCx) coronary artery occlusion, and postocclusion conditions. The dogs were preinstrumented with aortic and LV catheters, electromagnetic aortic and LCx coronary artery flow probes, high-fidelity LV micromanometers, LCx coronary artery occluders, and 4-mm ultrasonic transverse LV diameter and 2-mm regional LV segment crystal pairs. Radionuclide LV regional phase and amplitude variables were calculated for each condition. The absolute changes in LCx region RNA mean, median, and standard deviation of mean phase correlated with the percent changes in LCx segment crystal fractional shortening (r = -0.71, -0.64, and -0.51, respectively; all p less than or equal to 0.01). Similarly, the absolute changes and percent changes in LCx region RNA mean amplitude per pixel correlated with the percent changes in LCx segment crystal fractional shortening (r = 0.89 and 0.94, respectively; both p less than 0.001). When these LCx region RNA phase variables were subgrouped according to mild or severe depression or augmentation in LCx segment crystal fractional shortening, progressive differences were observed between the average values for these subgroups (p less than 0.05 to p less than 0.001). These data, therefore, suggest that these regional RNA phase variables may be able to detect and quantify alterations in LV contraction patterns due to transient ischemia.

Animals↗

Effects of calcium entry blockade on left ventricular dynamics in exercising dogs.

To study the previously undefined effects of calcium entry blockade on left ventricular (LV) function and coronary blood flow during dynamic exercise we gave intravenous equihypotensive infusions of nifedipine (10 +/- 4 SE micrograms X kg-1 X min-1), diltiazem (60 +/- 8 micrograms X kg-1 X min-1), and verapamil (52 +/- 7 micrograms X kg-1 X min-1) before and after intravenous propranolol (2 mg/kg) to chronically instrumented dogs at rest and while running on a treadmill at 4 and 10 km/h. Prior to beta-blockade, each agent significantly and equivalently (P = NS among drugs) reduced mean arterial pressure during exercise (-13% nifedipine, -8% diltiazem, -15% verapamil at 4 km/h, each P less than or equal to 0.01 vs. exercise alone) but did not significantly alter LV end-diastolic dimension (EDD), heart rate, or cardiac output compared with exercise alone. Only verapamil blunted the positive inotropic response to exercise (LV dP/dtmax decreased 20% at 4 km/h, P less than 0.01 vs. exercise alone). Coronary blood flow was significantly and equivalently increased at rest and during submaximal exercise with each calcium blocker, but this effect was largely offset by propranolol. During exercise after beta-blockade each agent produced significant additional reductions in mean arterial pressure and dP/dtmax at peak exercise but did not alter LVEDD or heart rate compared with results obtained with propranolol alone. Combined beta-blockade and verapamil uniquely diminished myocardial contractility to a greater extent at peak exercise than at rest (dP/dtmax 1,260 +/- 410 peak exercise vs. 1,775 +/- 431 mmHg/s rest, P less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

Adrenergic alpha-Antagonists↗

Accuracy of biplane axial oblique and oblique cineangiographic left ventricular cast volume determinations using a modification of Simpson's rule algorithm.

In order to compare biplane left ventricular cast volume determinations from orthogonal and nonorthogonal axial oblique and standard orthogonal oblique cineangiograms to those that were obtained by water (H2O) displacement, we evaluated 14 human heart specimens in the following projections: 30-degree right anterior oblique and 60-degree left anterior oblique/20-degree cranial (LVa), 45-degree left posterior oblique and 60-degree left anterior oblique/30-degree cranial (LVb), and 30-degree right anterior oblique and 60-degree left anterior oblique (LVc). The correlation coefficients and standard errors of the estimate (SEEs) for the biplane orthogonal and nonorthogonal axial oblique (LVa and LVb, respectively) and standard orthogonal oblique (LVc) cineangiographic left ventricular volume determinations compared with the left ventricular cast volumes obtained by H2O displacement were similar (each r = 0.99 with SEEs = 5 to 7 milliliters (ml)). However, the mean biplane cineangiographic cast volume of 69 +/- 43 ml (SD) by LVa exceeded the average left ventricular cast volume of 60 +/- 35 ml by H2O displacement (p less than 0.01), while the average left ventricular cast volumes obtained with LVb and LVc (63 +/- 35, and 60 +/- 34 ml, respectively) did not differ significantly from the mean left ventricular cast volume obtained by H2O displacement. We concluded that the biplane orthogonal and nonorthogonal axial oblique cineangiographic views of the left ventricle, which have been reported to improve the delineation of cardiac anatomy, left ventricular regional wall motion, and the assessment of mitral regurgitation, also provide accurate determinations of left ventricular volume that are similar to those calculated from standard biplane orthogonal oblique cineangiograms.

Cineangiography↗

Improved myocardial oxygen utilization by diltiazem in patients.

Calcium entry blocking drugs produce different effects on systemic and coronary hemodynamics and myocardial oxygen extraction. To examine the effects on myocardial oxygen extraction, intravenous diltiazem (100 micrograms/kg bolus with a continuous 10 micrograms/kg/min infusion) was administered to 11 patients at rest and during controlled heart rates (100 +/- 5 and 120 +/- 5 bpm). At rest, diltiazem decreased mean arterial pressure from 109 +/- 13 to 99 +/- 14 mm Hg (p less than 0.01), increased heart rate from 64 + 12 to 74 +/- 14 bpm (p less than 0.01), and decreased coronary sinus resistance (1.02 +/- .41 to 0.87 +/- .40 U, p less than 0.05). Myocardial oxygen extraction was significantly reduced since coronary sinus oxygen content increased (6.0 +/- 0.9 to 7.8 +/- 1.2 ml/dl, p less than 0.01) and the arterial-coronary sinus oxygen difference decreased (12.0 +/- 1.7 to 10.6 +/- 1.6 ml/dl, p less than 0.01). Similar changes occurred with heart rate held constant. There were no significant changes in absolute coronary sinus blood flow, calculated myocardial oxygen consumption, or left ventricular dP/dt. Diltiazem decreases mean arterial pressure while reducing both myocardial oxygen extraction and coronary arterial resistance, suggesting that a principal mechanism of a beneficial effect upon the coronary circulation appears to be an improvement in myocardial oxygen extraction relative to myocardial oxygen demand.

Adult↗

Selection of vasodilator therapy for severe Raynaud's phenomenon by sequential arterial infusion.

Two young adults with impending gangrene due to persistent Raynaud's vasospasm were studied by sequential intra-arterial (IA) infusion of three vasodilatory drugs while arterial pressure and plethysmographic digital pulse volume were continuously monitored. The results of the IA infusion accurately predicted relief from vasospastic symptoms by oral drugs of the same class. This method may be useful in selecting the most effective vasodilator for patients with severe vasospasm.

Adult↗

Segmental coronary artery disease: detection by rotating slant-hole collimator tomography and planar thallium 201 myocardial scintigraphy.

Normal quantitative circumferential profile limits were established for a 30 degrees bilateral rotating slant-hole (RSH) collimator tomographic system. This system's value in detecting segmental coronary artery disease was assessed in a study evaluating 196 patients by thallium 201 myocardial scintigraphy and coronary arteriography. Profile curves were calculated from images of 20 healthy patients and used to identify significant coronary artery disease (greater than or equal to 70% diameter narrowing) in the left anterior descending (LAD), the right, and the left circumflex (LCx) coronary arteries. In a group of 86 patients, an abnormality on the apical or middle plane optimally identified segmental coronary artery disease. When such abnormalities were prospectively evaluated in a test group of 110 patients, the sensitivity and specificity were 79% and 93% for LAD, 90% and 90% for right, and 83% and 83% for LCx coronary artery disease. Compared with qualitative interpretation of the planar and tomographic images, quantitative tomography significantly improved the sensitivity of T1-201 imaging in detecting LAD, right, and LCx coronary artery disease (P less than .001) in patients with or without previous myocardial infarction.

Adult↗

Validation of attenuation-corrected equilibrium radionuclide angiographic determinations of right ventricular volume: comparison with cast-validated biplane cineventriculography.

To determine the accuracy of attenuation-corrected equilibrium radionuclide angiographic determinations of right ventricular volumes, we initially studied 14 postmortem human right ventricular casts by water displacement and biplane cineventriculography. Biplane cineventriculographic right ventricular cast volumes, calculated by a modification of Simpson's rule algorithm, correlated well with right ventricular cast volumes measured by water displacement (r = .97, y = 8 + 0.88x, SEE = 6 ml). Moreover, the mean volumes obtained by both methods were no different (73 +/- 28 vs 73 +/- 25 ml). Subsequently, we studied 16 patients by both biplane cineventriculography and equilibrium radionuclide angiography. The uncorrected radionuclide right ventricular volumes were calculated by normalizing background corrected end-diastolic and end-systolic counts from hand-drawn regions of interest obtained by phase analysis for cardiac cycles processed, frame rate, and blood sample counts. Attenuation correction was performed by a simple geometric method. The attenuation-corrected radionuclide right ventricular end-diastolic volumes correlated with the cineventriculographic end-diastolic volumes (r = .91, y = 3 + 0.92x, SEE = 27 ml). Similarly, the attenuation-corrected radionuclide right ventricular end-systolic volumes correlated with the cineventriculographic end-systolic volumes (r = .93, y = - 1 + 0.91x, SEE = 16 ml). Also, the mean attenuation-corrected radionuclide end-diastolic and end-systolic volumes were no different than the average cineventriculographic end-diastolic and end-systolic volumes (160 +/- 61 and 83 +/- 44 vs 170 +/- 61 and 86 +/- 43 ml, respectively). Comparison of the uncorrected and attenuation-corrected radionuclide right ventricular volumes demonstrated narrower 95% confidence intervals for the attentuation-corrected right ventricular volume determinations over a wide range of cineventriculographic volumes. Thus we conclude that: (1) attenuation-corrected radionuclide right ventricular end-diastolic and end-systolic volumes compare closely with those obtained by a cast-validated biplane cineventriculographic method and (2) attenuation-corrected radionuclide right ventricular volumes correspond more closely to determinations of biplane cineventriculographic right ventricular volumes and are thus likely to be more accurate than uncorrected radionuclide right ventricular volumes.

Adolescent↗

Direct and indirect effects of calcium entry blocking agents on isovolumic left ventricular relaxation in conscious dogs.

To assess the direct and indirect effects of the commonly used calcium entry blockers (CEB) upon the major determinants of isovolumic left ventricular relaxation, we administered equidepressant intracoronary (IC, n = 7) and equihypotensive intravenous (n = 12) dosages of diltiazem (16 +/- 3 SE micrograms/kg IC and 63 +/- 9 micrograms/kg i.v.), verapamil (10 +/- 2 and 57 +/- 5 micrograms/kg), and nifedipine (1 +/- 0.1 and 8 +/- 0.3 micrograms/kg) to preinstrumented awake dogs with normal ventricular function. The time constant of left ventricle (LV) relaxation, analyzed by two methods (T1, from the linear relation of the natural logarithm of LV pressure and time; T2, from the linear relation of LV pressure and negative high fidelity LV pressure), was significantly and equivalently prolonged by IC diltiazem (T1 + 48%, P less than 0.02), verapamil (T1 + 43%, P less than 0.001), and nifedipine (T1 + 30%, P less than 0.03). Lesser amounts of each CEB that did not affect rate of LV pressure development or extent of shortening produced no change in T1 or T2. By contrast, intravenous calcium entry blockade either produced no significant change (diltiazem and verapamil) or shortened (nifedipine T1 - 18%, P less than 0.01) LV isovolumic relaxation. However, after beta adrenergic blockade with propranolol (2 mg/kg i.v., n = 6) no change in ventricular relaxation was observed during nifedipine and the time constant was significantly prolonged by verapamil (T1 + 15%, P less than 0.05). We conclude that calcium entry blockade directly impairs normal left ventricular relaxation: This effect is closely linked to the negative inotropic properties of these drugs. The prolongation of isovolumic relaxation produced by calcium blockade is attenuated or even reversed by reflex sympathetic stimulation and favorably altered loading conditions during systemic administration.

Adrenergic beta-Antagonists↗

Making crisis training profitable: a case history.

Lack of funding for crisis training of security officers can be overcome if you obtain the support of other departments who will be the beneficiaries of such training. Here is how one security director obtained the funding she needed and turned this new capability into a marketing plus for the hospital.

Hospital Bed Capacity, 500 and over↗

Hemodynamic profile of constrictive pericarditis produced by a massive right pleural effusion.

We report a 29-year-old female who presented with thyrotoxicosis and a massive right pleural effusion. Cardiac catheterization in the presence of the effusion revealed equalization of abnormally elevated right and left heart filling pressures. Repeat study after thoracentesis demonstrated normal intracardiac pressures, which were unchanged by volume loading with normal saline. This case report suggests that both extrinsic cardiac chamber compression produced by the large unilateral effusion and ventricular interdependence altered diastolic function of the right and left ventricle in a manner resembling constrictive pericarditis or restrictive cardiomyopathy.

Adult↗

Single coronary artery with the right coronary artery arising from the first septal perforator.

A 50-year-old woman with chest pain and an exercise thallium-201 scintigram positive for focal ischemia was found on coronary arteriography to have a heretofore unreported variant of single left coronary artery with the right coronary artery originating as a branch from the first septal perforator. Proximally, the aberrant vessel coursed through the ventricular septum at the level of the right ventricular outflow tract. A conus artery was absent and this is a possible basis for the focal basal ventricular ischemia and the patient's symptoms.

Coronary Vessel Anomalies↗

Accurate estimates of absolute left ventricular volumes from equilibrium radionuclide angiographic count data using a simple geometric attenuation correction.

To simplify and clarify the methods of obtaining attenuation-corrected equilibrium radionuclide angiographic estimates of absolute left ventricular volumes, 27 patients who also had biplane contrast cineangiography were evaluated. Background-corrected left ventricular end-diastolic and end-systolic counts were obtained by semiautomated variable and hand-drawn regions of interest and were normalized to cardiac cycles processed, frame rate and blood sample counts. Blood sample counts were acquired on (d degree) and at a distance (d') from the collimator. A simple geometric attenuation correction was performed to obtain absolute left ventricular volume estimates. Using blood sample counts obtained at d degree or d', the attentuation-corrected radionuclide left ventricular end-diastolic volume estimates using both region of interest selection methods correlated with the cineangiographic end-diastolic volumes (r = 0.95 to 0.96). However, both mean radionuclide semiautomated variable left ventricular end-diastolic volumes (179 +/- 100 [+/- 1 standard deviation] and 185 +/- 102 ml, p less than 0.001) were smaller than the average cineangiographic end-diastolic volume (217 +/- 102 ml), and both mean hand-drawn left ventricular end-diastolic volumes (212 +/- 104 and 220 +/- 106 ml) did not differ from the average cineangiographic end-diastolic volume. Using the blood sample counts obtained at d degree or d', the attenuation-corrected radionuclide left ventricular end-systolic volume estimates using both region of interest selection methods correlated with the cineangiographic end-systolic volumes (r = 0.96 to 0.98). Also, using blood sample counts at d degree, the mean radionuclide semiautomated variable left ventricular end-systolic volume (116 +/- 98 ml, p less than 0.05) was less than the average cineangiographic end-systolic volume (128 +/- 98 ml), and the other radionuclide end-systolic volumes did not differ from the average cineangiographic end-systolic volume. Therefore, it is concluded that: 1) a simple geometric attenuation-correction of radionuclide left ventricular end-diastolic and end-systolic count data provides accurate estimates of biplane cineangiographic end-diastolic and end-systolic volumes; and 2) the hand-drawn region of interest selection method, unlike the semiautomated variable method that underestimates end-diastolic and end-systolic volumes, provides more accurate estimates of biplane cineangiographic left ventricular volumes irrespective of the distance blood sample counts are acquired from the collimator.

Adult↗

Estimates of left-ventricular volumes by equilibrium radionuclide angiography: importance of attenuation correction.

To compare the accuracy of attenuated and attenuation-corrected equilibrium radionuclide angiographic (RNA) left ventricular (LV) volume estimates, we studied 23 consecutive patients with biplane contrast cineangiography (CINE). Attenuated RNA end-diastolic (ED) and end-systolic (ES) volumes were calculated from background-corrected ED and ES counts obtained from hand-drawn regions of interest that were normalized to cardiac cycles processed, frame rate, and blood activity. A simple, geometric attenuation correction was performed to obtain attenuation-corrected RNA LV volumes. The attenuated and attenuation-corrected RNA LV EDV estimates correlated with the CINE LV EDVs ; however, the attenuation-corrected RNA LV EDV estimates correlated more closely. Also, the average attenuation-corrected RNA LV EDV did not differ significantly from the mean CINE LV EDV. Attenuated and attenuation-corrected RNA LV ESV estimates also correlated with the CINE LV ESVs , but the attenuation-corrected RNA LV ESV estimates correlated more closely. Also, the average attenuation-corrected RNA LV ESV did not differ significantly from the mean biplane CINE LV ESV.

Adult↗

Influence of vagotomy on changes in feline plasma catecholamine levels induced by occlusion of either the left or right coronary vessel.

The purpose of this study was two-fold: (1) to determine the effect of occlusion of the left anterior descending branch (LAD) of the left coronary artery or the right coronary (RC) artery on plasma catecholamine levels, and (2) to determine whether bilateral vagotomy has an effect on changes in plasma catecholamine levels evoked by coronary occlusion. Chloralose anaesthetised cats subjected to LAD occlusion exhibited increases in plasma noradrenaline and adrenaline at 3 min post-occlusion. The increases in noradrenaline and adrenaline were unrelated to the hypotension that occurred at this time. Bilateral vagotomy did not appear to alter the effect of LAD occlusion on catecholamine release into the circulation but did unmask a significant correlation between the degree of hypotension and the magnitude of increase in plasma catecholamines. Right coronary occlusion in animals with intact and sectioned vagus nerves evoked noradrenaline and adrenaline release that was significantly correlated with a fall in arterial pressure. Bilateral vagotomy per se caused an increase in baseline plasma catecholamine levels. Pretreatment with atropine mimicked the increase in baseline catecholamine levels seen with vagotomy. These results indicate that occlusion of the LAD and RC arteries increase the release of catecholamines into the circulation. The role of the vagus nerves in this response was observed only with LAD occlusion and consisted of altering the relationship between the degree of hypotension and the magnitude of increase in plasma catecholamines. That is, after vagotomy, the decrease in blood pressure following LAD occlusion was effective in causing release of catecholamines, presumably because of the hypotension causing a decrease in baroreceptor stimulation. Finally, it appeared that vagotomy increases the release of noradrenaline into the circulation by removing efferent vagal tone that inhibits noradrenaline release. This inhibitory action is mediated by activation of muscarinic receptors.

Animals↗