Estimating defibrillation efficacy using combined upper limit of vulnerability and defibrillation testing.

It is frequently necessary, both clinically and in the laboratory, to estimate how strong a stimulus is required to defibrillate. Current techniques for forming such estimates require the repeated induction of ventricular fibrillation (VF) and subsequent attempts at defibrillation (DF testing). DF testing can be time consuming and in the operating room may increase the patient risks. A novel scheme is presented which combines DF testing with upper limit of vulnerability (ULV) testing. ULV testing is a relatively safe procedure which yields data well correlated with defibrillation efficacy. A Bayesian statistical model of combined ULV/DF testing is presented which is both powerful and concise. The model is used in two examples to design minimum rms error protocols and estimators for the DF95 (the stimulus strength which defibrillates 95% of the time). A simulation for humans of one example solution shows that a single VF episode of combined ULV/DF testing (rms error = 23% of the mean DF95) is better than two VF episodes with DF testing alone (25%). The simulation results for a second example are directly compared with laboratory results from six pigs, showing a less than 1.0% average difference between the simulated and measured rms errors.

Algorithms↗

Effect of rapid pacing and T-wave scanning on the relation between the defibrillation and upper-limit-of-vulnerability dose-response curves.

BACKGROUND: The critical-point and upper-limit-of-vulnerability (ULV) hypotheses predict that the ULV dose-response curve should be steeper and to the right of the defibrillation (DF) curve. Yet, some recent experimental data contradict this prediction. Two studies are presented that test two explanations for the contradiction: (1) Testing at a single point in the T wave underestimates the ULV dose-response curve and (2) ULV testing at normal heart rates does not mimic the mechanical or electrical state of the heart in ventricular fibrillation (VF). METHODS AND RESULTS: A nonthoracotomy lead system with a biphasic waveform was used throughout. In eight dogs, the dose-response curve widths (a measure of steepness) were compared between DF data and ULV data gathered at the peak (ULVPK), middownslope (ULVDWN), midupslope (ULVUP), and all times (scanning or ULVSCN) in the T wave. In another eight dogs, ULV data (ULVRAP) were gathered by scanning the T wave after 15 rapidly paced beats (166- to 198-ms pacing interval). The rapid pacing interval was chosen to more closely mimic the hemodynamics and activation rate of early VF. ULV data (ULVSTD) at normal heart rates were gathered for all animals. In the first study, scanning significantly reduced the ULV curve width (ULVSCN, 63.5 +/- 29.7 V; ULVPK, 81.9 +/- 45.2 V; ULVDWN, 116 +/- 36.5 V; DF, 105 +/- 22.0 V; P < .03) and significantly shifted the ULV curve to the right (ULV80 SCN, 410 +/- 62.6 V; ULV80 PK, 266 +/- 35.3 V; ULV80 DWN, 355 +/- 80.4 V; DF80, 427 +/- 60.9 V; P < .001). The subscript 80 signifies that the subject was left in normal sinus rhythm 80% of the time after that stimulus strength was delivered. In the second study, the ULVRAP curve was shifted dramatically to the right, the average ULV50 RAP being greater than the average DF90. Furthermore, 92% of the ULVRAP VF inductions occurred between 10 ms before and 50 ms after the peak of the T wave, suggesting that scanning of the entire T wave may not be necessary. CONCLUSIONS: With a single rapidly paced ULV sequence with limited T-wave scanning, it may be possible to estimate highly effective defibrillation doses with few VF episodes and high-voltage stimuli.

Animals↗

Comparison of upper limit of vulnerability and defibrillation probability of success curves using a nonthoracotomy lead system.

BACKGROUND: An upper limit to the strength of shocks that induce fibrillation during the vulnerable period, the upper limit of vulnerability (ULV), has been shown to exist in both humans and animals. The purpose of this study was to compare ULV and defibrillation (DF) probability of success curves for a clinically useful nonthoracotomy lead system. METHODS AND RESULTS: Sixteen pentobarbital-anesthetized pigs were studied. Single-capacitor biphasic waveforms with both phases 5.5 ms in duration were used for ULV and DF testing. A right ventricular catheter electrode served as first-phase cathode and a superior vena cava catheter electrode coupled with a cutaneous R2 patch electrode served as common first-phase anodes. A pacing catheter was placed in the right ventricle to deliver a train of 15 S1 stimuli at a pacing interval of 250 to 300 ms. A ULV shock was delivered on the peak of the T wave as measured from the surface ECG; if ventricular fibrillation was induced, a DF shock was delivered after 10 seconds of fibrillation. Shock voltages were determined by an up-down protocol. Ventricular fibrillation was induced an average of 53 times in each animal. The composite data indicate that below V97, that is, the voltage that leaves the animal in normal sinus rhythm 97% of the time when delivered on the peak of the T wave or the voltage that defibrillates 97% of the time, ULV is lower than DF. ULV and DF became significantly correlated at V80 and maximally correlated at V97. Even at V97, however, ULV and DF differed by more than 100 V in 2 of the 16 animals. CONCLUSIONS: ULV approximately equaled DF at V97. This is fortunate because it is clinically important to set the device voltage at the uppermost portion of the probability of success curve. Estimating DF V97 from ULV V97 would reduce the number of fibrillation inductions needed to establish defibrillation shock strength requirements. However, the large difference between ULV V97 and DF in a few animals indicates that further improvement and testing of algorithms for determining ULV V97 must be developed before the technique is used clinically.

Animals↗

Estimating the 95% effective defibrillation dose.

Minimum squared error (MinSE) testing protocols and a MinSE estimator are presented which accurately estimate the voltage that defibrillates 95% of the time (the ED95). The MinSE experimental procedures, presented in the form of lookup tables, detail the response to successful and unsuccessful trials. The lookup tables also show the ED95 estimates calculated from the observed results using the MinSE estimator. Two assumptions are required to develop the look-up tables: 1) the dose-response curve, chosen using a statistical analysis of a retrospective sample, and 2) the distribution of the ED95's in the population. The MinSE estimator and experimental procedure are examined in a prospective study of five dogs (19-25 kg, heart weights 139.3-236.9 gm) using nonthoracotomy implantable defibrillator electrodes and a biphasic defibrillation waveform (3.5 ms first phase, 2.0 ms second phase). Employing an ED95 population distribution assumption applicable to most implantable defibrillator electrodes and waveforms, e.g., the ED95 is between 0.0 and 800.0 V, the measured rms error was 15% of the mean measured ED95 for the MinSE, four test shock, ED95 estimates. If the protocols are designed with an ED95 population distribution assumption for animals of the same species and size, and defibrillation is constrained to one electrode configuration and waveform, the estimates improve by 3.8%. Using techniques from the Bayesian statistics literature, the MinSE approach can be extended to a variety of defibrillation parameter estimation problems.

Algorithms↗