Search PubMed⌕ Search

Biomedical subjects

Pirjo Lillsunde

Publications and source records attributed to Pirjo Lillsunde.

7 recordsLinked to original sources

Fast gas chromatography-negative-ion chemical ionization mass spectrometry with microscale volume sample preparation for the determination of benzodiazepines and alpha-hydroxy metabolites, zaleplon and zopiclone in whole blood.

Fast gas chromatography/negative-ion chemical ionization mass spectrometric (GC/NICI-MS) assay combined with rapid and nonlaborious sample preparation is presented for the simultaneous determination of benzodiazepines and alpha-hydroxy metabolites, zaleplon and zopiclone in whole blood. The compounds were extracted from 100 microl of whole blood by simultaneous multitube, microscale liquid-liquid extraction (LLE) and derivatized by N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA), without the need for the time-consuming concentration stage. In the analytical separation, various parameters of fast GC/NICI-MS were applied, e.g. the use of hydrogen as a GC carrier gas, a high carrier gas velocity, a small film thickness of the analytical column, fast MS data acquisition, fast temperature ramping, and high initial and final temperatures of GC column. Sensitive identification, screening and quantitation of 18 compounds of interest were achieved in chromatographic separation in only 4.40 min. Accurate and reproducible results were obtained by using five different and carefully selected deuterated analogues on the basis of the chemical properties of the target analytes. Nevertheless, for alpha-OH-midazolam, and for bromazepam and flunitrazepam at low concentrations, the results can be considered only semiquantitative on the basis of the validation data. The extraction efficiencies ranged from 74.3 to 105.7% and the limits of quantitation (LOQ) from 1 to 100 ng ml(-1). Rapid sample preparation and fast chromatographic separation allowed cost-efficient, reliable and high sample-throughput analyses with a low amount of manual work. The method was fully validated and accredited according to EN ISO/IEC 17025 standards and is applicable for sensitive, reliable and quantitative determination of benzodiazepines, zaleplon and zopiclone, e.g. in clinical and forensic toxicology.

Acetamides↗

Fast gas chromatography/mass spectrometric assay for the validated quantitative determination of methadone and the primary metabolite EDDP in whole blood.

A toxicological analysis was developed and validated for simultaneous screening and quantification of methadone (METH) and its primary metabolite 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP). The method employs microscale liquid-liquid extraction (microLLE) and direct injection of a separated aliquot of the organic layer into a gas chromatography/mass spectrometric (GC/MS) system without any other pre-treatment stages. A fast GC/MS runtime (total 5.8 min; METH, Rt = 3.55 min; EDDP, Rt = 3.40 min) combined with rapid sample preparation allowed cost-efficient and routinely applicable performance with a low amount of manual work. The validated parameters included: linearity (25-1000 ng mL(-1) both; R(METH)2 = 0.998 and R(EDDP)2 = 0.997), accuracy (Bias(METH): from -0.05 to 11.3%, Bias(EDDP): from 1.11 to 4.37%); intra and inter-assay precision (RSD(METH): from 2.4 to 3.9%, from 4.89 to 10.3%; RSD(EDDP): from 4.50 to 6.20%, from 4.57 to 15.2%), extraction efficiency (METH = 95.5%; EDDP = 90.6%), LOQ(Meth,EDDP) = 25 ng mL(-1). Samples were stable for at least 25 h and no selectivity problems or baseline interference were observed. The method should be applicable for identifying and quantitative confirmation of possible misuse and/or illegal use of METH in toxicological cases.

Gas Chromatography-Mass Spectrometry↗

[Not Available].

Explore the source record for details and available documents.

Journal Article↗

Determination of 14 benzodiazepines and hydroxy metabolites, zaleplon and zolpidem as tert-butyldimethylsilyl derivatives compared with other common silylating reagents in whole blood by gas chromatography-mass spectrometry.

The most common commercially available silylating reagents, N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA), N,O-bis-(trimethylsilyl)trifluoroacetamide+1% trimethylchlorosilane (BSTFA+1% TMCS) and N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA) were evaluated to achieve optimal derivatization conditions for analyzing various benzodiazepines based on gas chromatography-electron impact ionization-mass spectrometry (GC-EI-MS). Sensitivity, repeatability, retention times and stability of the derivatives, as well as specificity of mass fragmentation, were studied in detail. Also other parameters affecting the derivatization chemistry of benzodiazepines are discussed. tert-Butyldimethylsilyl (TBDMS) derivatives proved to be more stable, reproducible and sensitive than corresponding trimethylsilyl (TMS) derivatives for the GC-EI-MS analysis of benzodiazepines. Based on the TBDMS derivatives, a rapid, reliable, sensitive and quantitative GC-MS method was developed for the determination of 14 benzodiazepines and two hydroxy metabolites, as well as two non-benzodiazepine hypnotic agents, zolpidem and zaleplon, using 50 microl of whole blood. The method was completely validated in terms of accuracy, intra- and interday precision, limit of detection (LOD), limit of quantitation (LOQ), linearity, selectivity and extraction efficiency; these were all within the required limits, except for the accuracy of nitrazepam at a medium concentration level.

Acetamides↗

Validated toxicological determination of 30 drugs of abuse as optimized derivatives in oral fluid by long column fast gas chromatography/electron impact mass spectrometry.

An analytical procedure was developed for the simultaneous sensitive identification, screening and quantitation of 30 drugs of abuse using 250 microl of human oral fluid. The method employs sequential mixed-mode solid-phase extraction (SPE), optimized derivative formation and long-column fast gas chromatography/electron impact mass spectrometry (GC/EI-MS). After sequential SPE elution, the most sensitive and stable derivatives were formed by taking careful account of the characteristics of the active functional groups and possible steric hindrances affecting derivatization chemistry. Amphetamine-type stimulant drugs were acylated with heptafluorobutyric anhydride, benzodiazepines and Delta(9)-tetrahydrocannabinol were silylated with N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide and benzoylecgonine, codeine, ethylmorphine, 6-monoacetylmorphine, morphine, pholcodine, buprenorphine and norbuprenorphine with N-methyl-N-(trimethylsilyl)trifluoroacetamide. In addition, the following analytes were included: methadone, cocaine, alprazolam, midazolam, fentanyl and zolpidem. In GC separation, fast temperature ramping and high carrier gas flow-rate combined with long 30 m columns of i.d. 0.32 mm offered a reduction in analysis time and sharp peak shapes while still maintaining sufficient resolution and high sample capacity. Validated parameters including selectivity, linearity, accuracy, intra- and inter-day precision, extraction efficiency and limit of quantitation were all within required limits. In contrast to previously published methods, this single procedure is suitable for the simultaneous toxicological determination of the most common illicit drugs and benzodiazepines, and also zolpidem, in a small amount of oral fluid.

Gas Chromatography-Mass Spectrometry↗

Single-step procedure for gas chromatography-mass spectrometry screening and quantitative determination of amphetamine-type stimulants and related drugs in blood, serum, oral fluid and urine samples.

We describe a rapid GC/MS assay for amphetamine-type stimulant drugs (ATSs) and structurally related common medicaments in blood, serum, oral fluid and urine samples. The drugs were extracted from their matrices and derivatized with heptafluorobutyric anhydride (HFBA) in a single step, using the following procedure: 100 microl (oral fluid) or 200 microl (blood, serum, urine) of the sample were mixed with 50 microl of alkaline buffer and 500 microl of extraction-derivatization reagent (toluene + HFBA + internal standard), centrifuged, and injected into a GC/MS apparatus. As revealed by the validation data this procedure, with its limit of quantitation being set at 20 ng/ml for oral fluid, 25 ng/ml for blood or 200 ng/ml for urine, is suitable for screening, identification and quantitative determination of the ATSs and related drugs in all the matrices examined. Thus, time-consuming and expensive multiple analyses are not needed, unless specifically required.

Amphetamines↗

Validated semiquantitative/quantitative screening of 51 drugs in whole blood as silylated derivatives by gas chromatography-selected ion monitoring mass spectrometry and gas chromatography electron capture detection.

A comprehensively validated procedure is presented for simultaneous semiquantitative/quantitative screening of 51 drugs of abuse or drugs potentially hazardous for traffic safety in serum, plasma or whole blood. Benzodiazepines (12), cannabinoids (3), opioids (8), cocaine, antidepressants (13), antipsychotics (5) and antiepileptics (2) as well as zolpidem, zaleplon, zopiclone, meprobamate, carisoprodol, tizanidine and orphenadrine and internal standard flurazepam, were isolated by high-yield liquid-liquid extraction (LLE). The dried extracts were derivatized by two-step silylation and analyzed by the combination of two different gas chromatographic (GC) separations with both electron capture detection (ECD) and mass spectrometry (MS) operating in a selected ion-monitoring (SIM) mode. Quantitative or semiquantitative results were obtained for each substance based on four-point calibration. In the validation tests, accuracy, reproducibility, linearity, limit of detection (LOD) and limit of quantitation (LOQ), selectivity, as well as extraction efficiency and stability of standard stock solutions were tested, and derivatization was optimized in detail. Intra- and inter-day precisions were within 2.5-21.8 and 6.0-22.5%, and square of correlation coefficients of linearity ranged from 0.9896 to 0.9999. The limit of quantitation (LOQ) varied from 2 to 2000 ng/ml due to a variety of the relevant concentrations of the analyzed substances in blood. The method is feasible for highly sensitive, reliable and possibly routinely performed clinical and forensic toxicological analyses.

Gas Chromatography-Mass Spectrometry↗