Search PubMed⌕ Search

Biomedical subjects

Piotr Slomka

Publications and source records attributed to Piotr Slomka.

7 recordsLinked to original sources

Direct quantitative in vivo comparison of calcified atherosclerotic plaque on vascular MRI and CT by multimodality image registration.

PURPOSE: To investigate direct volumetric in vivo correspondence of calcified atherosclerotic plaque lesions in MRI and CT images of the thoracic aorta by multimodality image registration and fusion. MATERIALS AND METHODS: Twelve CT (11 noncontrast and one contrast) and MRI (TruFISP, contrast T1-weighted volumetric interpolated breath-hold examination (VIBE)) data sets were co-registered by approximate segmentation of the aorta and subsequent automatic co-registration by maximization of mutual information (MI). We quantitatively assessed 22 co-registered calcified plaque lesions on CT and MRI. RESULTS: The three-dimensional registration consistency and accuracy were 1.74 +/- 1.3 mm, and 2.42 +/- 1.65 mm, respectively. The ratio of CT/MRI calcified plaque volume decreased asymptotically with MRI volume, and correlated with average CT lesion density (r = 0.72) for small lesions (<25 mm(3)). The average calcified plaque volume, circumferential extent, and maximal radial width by MRI were significantly smaller compared to CT (35%, 68%, and 53%, respectively; P < 0.05). CONCLUSION: Software co-registration allowed precise, direct, and voxel-based comparison of calcified atherosclerotic plaque lesions imaged by MRI and CT. In comparison with co-registered MRI, overestimation of calcified plaque in aortic CT due to "blooming" correlates with the average lesion density for small plaques, and is greater for small plaques.

Aged↗

Gated myocardial perfusion single photon emission computed tomography in the clinical outcomes utilizing revascularization and aggressive drug evaluation (COURAGE) trial, Veterans Administration Cooperative study no. 424.

BACKGROUND: Stress gated myocardial perfusion single photon emission computed tomography (gSPECT) is increasingly used before and after intercurrent therapeutic intervention and is the basis for ongoing evaluation in the Department of Veterans Affairs clinical outcomes utilizing revascularization and aggressive drug evaluation (COURAGE) trial. METHODS AND RESULTS: The COURAGE trial is a North American multicenter randomized clinical trial that enrolled 2287 patients to aggressive medical therapy vs percutaneous coronary intervention plus aggressive medical therapy. Three COURAGE nuclear substudies have been designed. The goals of substudy 0 are to examine the diagnostic accuracy of the extent and severity of inducible ischemia at baseline in COURAGE patients compared with patient symptoms and quantitative coronary angiography and to explore the relationship between inducible ischemia and the benefit from revascularization when added to medical therapy. Substudy 1 will correlate the extent and severity of provocative ischemia with the frequency, quality, and instability of recurrent symptoms in postcatheterization patients. Substudy 2 (n = 300) will examine the usefulness of sequential gSPECT monitoring 6 to 18 months after therapeutic intervention. Together, these nuclear substudies will evaluate the role of gSPECT to determine the effectiveness of aggressive risk-factor modifications, lifestyle interventions, and anti-ischemic medical therapies with or without revascularization in reducing patients' ischemic burdens. CONCLUSIONS: The unfolding of evidence on the application of gSPECT in trials such as COURAGE defines a new era for nuclear cardiology. We hope the evidence that emerges from the COURAGE trial will further establish the role of nuclear imaging in the evidence-based management of patients with stable coronary disease.

Algorithms↗

Coronary x-ray angiographic reconstruction and image orientation.

We have developed an interactive geometric method for 3D reconstruction of the coronary arteries using multiple single-plane angiographic views with arbitrary orientations. Epipolar planes and epipolar lines are employed to trace corresponding vessel segments on these views. These points are utilized to reconstruct 3D vessel centerlines. The accuracy of the reconstruction is assessed using: (1) near-intersection distances of the rays that connect x-ray sources with projected points, (2) distances between traced and projected centerlines. These same two measures enter into a fitness function for a genetic search algorithm (GA) employed to orient the angiographic image planes automatically in 3D avoiding local minima in the search for optimized parameters. Furthermore, the GA utilizes traced vessel shapes (as opposed to isolated anchor points) to assist the optimization process. Differences between two-view and multiview reconstructions are evaluated. Vessel radii are measured and used to render the coronary tree in 3D as a surface. Reconstruction fidelity is demonstrated via (1) virtual phantom, (2) real phantom, and (3) patient data sets, the latter two of which utilize the GA. These simulated and measured angiograms illustrate that the vessel center-lines are reconstructed in 3D with accuracy below 1 mm. The reconstruction method is thus accurate compared to typical vessel dimensions of 1-3 mm. The methods presented should enable a combined interpretation of the severity of coronary artery stenoses and the hemodynamic impact on myocardial perfusion in patients with coronary artery disease.

Adult↗

Computer-aided detection and evaluation of lipid-rich plaque on noncontrast cardiac CT.

OBJECTIVE: Noncontrast electron beam CT (EBCT) and MDCT are established for the assessment of calcified plaque, but not lipid-rich plaque. We developed software to identify lipid-rich plaque with noncontrast electron beam tomography (EBT) and MDCT. MATERIALS AND METHODS: A computer algorithm was developed to automatically find contiguous lipid-rich lesions with voxel intensities below a calculated patient-specific lipid threshold. Lipid density and lipid inhomogeneity in Hounsfield units were calculated in the proximal left coronaries of three populations: 34 low-risk patients (low-risk group < 6% Framingham risk score, no calcium), 31 high-risk patients (high-risk group > 20% Framingham risk score, no calcium), and 37 patients with calcified plaque (calcium group). RESULTS: The mean lipid density was -19.6 +/- 3.0 (SD) H in the low-risk group, -25.3 +/- 8.2 H in the high-risk group, and -34.3 +/- 13.0 H in the calcium group (p < 0.05). The mean lipid inhomogeneity was 17.7 +/- 3.6 H in the low-risk group, 21.5 +/- 5.5 H in the high-risk group, and 29.0 +/- 7.6 H in the calcium group (p < 0.05). The mean interscan variability in lipid density and lipid inhomogeneity were 2.0 +/- 3.3 H and 2.1 +/- 3.6 H, respectively. In five patients, the locations of lipid-rich plaque correlated well with available intravascular sonography findings. CONCLUSION: Our method may be able to identify lipid-rich plaque on noncontrast cardiac CT.

Adult↗

Roles of nuclear cardiology, cardiac computed tomography, and cardiac magnetic resonance: assessment of patients with suspected coronary artery disease.

Noninvasive cardiac imaging is now central to the diagnosis and management of patients with known or suspected chronic coronary artery disease (CAD). Although rest echocardiography has become the most common of the techniques, nuclear cardiology and more recently cardiac computed tomography (CCT) and cardiac magnetic resonance (CMR) play important roles in this regard. This review examines the current applications and interactions of noninvasive cardiac imaging approaches for the assessment of patients with suspected CAD. In addition to considering the strengths and weaknesses of each technique, this review attempts to provide a guide to the selection of a test (or tests) that is based on the question being asked and the ability of each test to answer this question. In patients with suspected CAD, the pretest likelihood of disease, a clinical assessment, becomes the most important determinant of the initial test. If the likelihood is very low, no testing is needed. However, if the likelihood is low, recent data suggest that assessment of early atherosclerosis is likely to be the most useful and cost-effective test. In patients who have an intermediate likelihood of CAD, nuclear cardiology with myocardial perfusion SPECT (MPS) becomes highly valuable; however, coronary CT angiography (CTA), with fast 16-slice or greater scanners, may emerge as the initial test of choice. MPS would then be used if the CTA is inconclusive or if there is a need to assess the functional significance of a stenosis defined by CTA. Coronary CTA, however, is not yet widely available and is limited in patients with dense coronary calcification. In older patients with a high likelihood of CAD, MPS may be the initial test of choice, since a high proportion of these patients have too much coronary calcium to allow accurate assessment of the presence of coronary stenoses. PET/CT or SPECT/CT could emerge as important modalities combining the advantages of each modality. While CMR has great promise as a radiation-free and contrast-free "one-stop" shop, it currently lags behind CTA for noninvasive coronary angiography. Nonetheless, CMR clearly has the potential for this application and has already emerged as a highly effective method for assessing ventricular function, myocardial mass, and myocardial viability, and there is increasing use of this approach for clinical rest and stress perfusion measurements. CMR is particularly valuable in distinguishing ischemic from nonischemic cardiomyopathy. While CT and CMR are likely to grow considerably in diagnostic evaluation over the next several years, MPS and PET will continue to be very valuable techniques for this purpose.

Cardiology↗

Techniques for efficient, real-time, 3D visualization of multi-modality cardiac data using consumer graphics hardware.

We exploit consumer graphics hardware to perform real-time processing and visualization of high-resolution, 4D cardiac data. We have implemented real-time, realistic volume rendering, interactive 4D motion segmentation of cardiac data, visualization of multi-modality cardiac data and 3D display of multiple series cardiac MRI. We show that an ATI Radeon 9700 Pro can render a 512x512x128 cardiac Computed Tomography (CT) study at 0.9 to 60 frames per second (fps) depending on rendering parameters and that 4D motion based segmentation can be performed in real-time. We conclude that real-time rendering and processing of cardiac data can be implemented on consumer graphics cards.

Algorithms↗

Reversible ischemia around intracerebral hemorrhage: a single-photon emission computerized tomography study.

OBJECT: A zone of perilesional ischemia has been demonstrated around intracerebral hemorrhage (ICH) in numerous experimental models and in human studies. There is potential for perfusion recovery in the zone of perilesional oligemia around ICH. The authors sought to demonstrate, quantify, and study the chronological evolution of perilesional ischemic change in ICH in humans by measuring cerebral blood flow. METHODS: Eleven patients with spontaneous supratentorial ICH underwent two technetium-99m hexamethylpropyleneamine oxime single-photon emission computerized tomography (SPECT) scanning, one in the acute stage (within days of ictus) and the other in the late stage (6-9 months postictus). All patients in this study were treated nonsurgically. Methods of SPECT data analysis based on count differences in regions of interest can be difficult to apply to images with large space-occupying lesions such as ICH, because of the distortion of intracranial anatomy, midline shift, and alterations in the three-dimensional (3D) characteristics of the lesion over time (that is, absorption of the hematoma on the later studies). The authors used the following method: the late and early images were registered and aligned to a common 3D orientation and were normalized to maximal counts. The late images were then compared voxel by voxel with the early ones. The region-growing algorithm was used to discern the difference between the two images, outlining voxels in the perihematoma region, with a signal improvement of at least 15% on the late image. Discrete brain regions around the hematoma with at least a 15% improvement in radiotracer uptake (and hence perfusion) in the late images were observed in all cases. The mean volume of brain with a greater than 15% improvement in perfusion between the two studies was 34.8 cm3 (range 7.2-71.3 cm3). These volumes represent regions of the brain that were poorly perfused in the initial studies. This may represent a zone of reversible perilesional oligemia (penumbra) in ICH in humans. CONCLUSIONS: This is the first study in which it is documented that some of the perilesional hypoperfused tissue around human ICH regains its perfusion in the long term, leading the authors to suggest that there may be a penumbra in human ICH. Medical or surgical therapeutic interventions could increase the volume of perilesional brain that recovers after the initial insult. The results of this study therefore support the concept that intervention in ICH has the potential to reduce the ultimate neurological deficit and improve outcome.

Adult↗