Search PubMed⌕ Search

Biomedical subjects

Pierre-Olivier Bagnaninchi

Publications and source records attributed to Pierre-Olivier Bagnaninchi.

3 recordsLinked to original sources

Tissue engineering for tendon repair.

Tissue engineering aims to induce tissue self-regeneration in vivo or to produce a functional tissue replacement in vitro to be then implanted in the body. To produce a viable and functional tendon, a uniaxially orientated collagen type I matrix has to be generated. Biochemical and physical factors can potentially alter both the production and the organisation of this matrix, and their combination in a dose- and time-dependent manner is probably the key to in vitro engineered tendons. This review discusses the role of these different factors affecting tenocyte growth in a three-dimensional environment in vivo and in vitro, and underlines the future challenge of tendon tissue engineering.

Biocompatible Materials↗

Complex permittivity measurement as a new noninvasive tool for monitoring in vitro tissue engineering and cell signature through the detection of cell proliferation, differentiation, and pretissue formation.

In in vitro tissue engineering, microporous scaffolds are commonly used to promote cell proliferation and differentiation in three-dimensional structures. Classic measurement methods are particularly time consuming, difficult to handle, and destructive. In this study, a new nondestructive method based on complex permittivity measurement (CPM) is proposed to monitor and track the osteoblast and macrophage differentiation through their morphological variation upon cell attachment and proliferation inside the microporous scaffolds. CPM is performed using a vector network analyzer and a dielectric probe under sterile conditions in a laminar-flow hood. A suitable effective medium approximation (EMA) is applied to fit the data in order to extract the parameters of the different constituents. Our data show that the EMA depolarization factor can be monitored to assess the variation of cell morphology characterizing cell attachment. Discrimination between two batches of scaffolds seeded, respectively, with 2 million and 1 million osteoblast cells is possible; the ratio of their CPM-derived cell volume fractions is in agreement with the ratio of their cell seeding numbers. In addition, cell proliferation inside scaffolds seeded with osteoblasts cultured in alpha minimum essential medium and inside scaffolds seeded with osteoblasts cultured in alpha minimum essential medium supplemented to induce the formation of extracellular matrix is monitored via CPM over several days. CPM-determined cell volume fraction is compared to DNA assay cell counts. Extracellular matrix formation and cell presence was confirmed by scanning electron microscopy. A set of three signature parameters (epsilon'mem, epsilon'cyt, kappa'cyt) characteristic of cell line is extracted from CPM. Distinct signatures are recorded for osteoblasts and macrophages, thus confirming the ability of CPM to discriminate between different cell types. This study demonstrates the potential of CPM as a diagnostic tool to monitor quickly and noninvasively cell growth and differentiation inside microporous scaffolds. Our findings suggest that the use of CPM could be extended to many biomedical applications, such as drug detection and automation of tissue and bacterial cultures in bioreactors.

3T3 Cells↗

Towards on-line monitoring of cell growth in microporous scaffolds: Utilization and interpretation of complex permittivity measurements.

Here we demonstrate the ability to characterize microporous scaffolds and evaluate cell concentration variation via the utilization and interpretation of complex permittivity measurements (CP), a direct and nondestructive method. Polymer-based microporous scaffolds are of importance to tissue engineering, particularly in the promotion of cell adhesion, proliferation, and differentiation in predefined shapes. Chitosan gel scaffolds were seeded with increasing concentrations of macrophages to simulate cell growth. Complex permittivity measurements were performed using a dielectric probe and a vector network analyzer over a frequency ranging from 200 MHz to 2 GHz. An effective medium theory was applied to interpret the data obtained; respectively, Looyenga and Maxwell-Wagner-Hanai functions were used to retrieve the porosity and the variation of the cell concentration from the CP measurements. Calculated porosities were in agreement with experimental evaluation-porosity ranged from 81-96%. Changes in cell concentration inside the scaffolds upon injection of differing cell concentrations into the scaffold were detected distinguishably. Variations resulting from the cumulative injection of 400-1800 microL of 10(6) cells/mL solution into the scaffold were monitored. Results suggest that CP measurements in combination with an appropriate effective medium approximation can enable on-line monitoring of cell growth within scaffolds.

Algorithms↗