Laboratory network of excellence: enhancing patient safety and service effectiveness.

Clinical laboratories have undergone major changes due to technological progress and economic pressure. While costs of laboratory testing continue to be the dominant issue within the healthcare service worldwide, quality, effectiveness and impact on outcomes are also emerging as critical value-added features. Five Italian laboratories are therefore promoting a network of excellence by investigating markers of effectiveness of laboratory services and sharing their experience of using them in clinical practice. In the present study we report preliminary data on indicators of quality in all phases of the so-called total testing process, the key to evaluating all phases of the total testing process, including the appropriateness of test requests and data interpretation. Initial findings in evaluating pre-analytical causes of specimen rejection in three different laboratories and the effects of introducing three laboratory clinical guidelines are reported. These data should stimulate debate in the scientific community and encourage more clinical laboratories to use the same indicators to improve clinical effectiveness and clinical outcomes within the healthcare service.

Clinical Laboratory Techniques↗

Specific immunofluorimetric assay detecting the chemotactic epitope of the urokinase receptor (uPAR).

The urokinase plasminogen activator receptor (uPAR) fragments D1 and D2D3 are often found in biological fluids from normal individuals and patients of cancer and other diseases. The D2D3 fragment may possess chemotactic activity depending on its N-terminal sequence. We have developed a sensitive and specific immunoassay for the chemotactic form of D2D3 and show that its level can be measured with high specificity and sensitivity in human serum and urine. Synthetic peptides (residues 84-92) derived from the linker region between domains 1 and 2 of uPAR were used as immunogens to generate mouse monoclonal antibodies. Recombinant soluble uPAR (D1D2D3(1-277)) was used to immunize rabbits to obtain polyclonal antibodies. A sandwich-type immunofluorimetric assay was developed with these antibodies. The assay specifically measures D2D3 containing the 84-88 residues, has a detection limit of 0.25 ng/ml and shows no cross-reactivity with D2D3(93-274). The assay is linear at 0-30 ng/ml, with an intra-assay CV of 10% (n=20), inter-assay CV of 15% (n=9) and a recovery of D2D3(84-274) added to urine samples of between 94% and 105%. A statistically significant difference level of D2D3(84-274) was found in two groups of tumor patients versus healthy volunteers (p<or=0.009 in colorectal carcinomas and p<or=0.036 in prostatic carcinomas). For the first time, monoclonal antibodies, detecting the chemotactic form of uPAR, D2D3(84-274), have been produced. The immunofluorimetric assay will quantitate uPAR chemotactic fragments in biological samples, including serum and urine, and evaluate their diagnostic or prognostic potential in clinical studies.

Amino Acid Sequence↗

Single-nucleotide polymorphism and mutation identification by the nanogen microelectronic chip technology.

The present chapter describes a microarray technology developed by Nanogen Inc., for the identification of DNA variations based on the use of microelectronics. The NMW 1000 NanoChip Molecular Biology Workstation allows the active deposition and concentration of charged biotinylated molecules on designated test sites. The DNA at each pad is then hybridized with specific oligonucleotide probes, complementary to normal or mutant sequences, that labeled with Cy3 or Cy5 dyes, respectively. The array is imaged, and fluorescence signals are scanned, monitored, and quantified by highly developed, digital image-processing procedures. The experimental steps to be performed for the development and execution of a microchip assay are described. Attention is focused on the fundamental aspects of probe design, and guidelines and useful suggestions are given. Protocols for sample preparation, addressing, reporting, and data analysis are also detailed.

Base Sequence↗

Molecular diagnostics by microelectronic microchips.

Molecular diagnostics is being revolutionized by the development of highly advanced technologies for DNA and RNA testing. One of the most important challenges is the integration of microelectronics to microchip-based nucleic acid technologies. The specific characteristics of these microsystems make the miniaturization and automation of any step of a molecular diagnostic procedure possible. This review describes the application of microelectronics to all the processes involved in a genetic test, particularly to sample preparation, DNA amplification and sequence variation detection.

Animals↗

Molecular diagnostics by microelectronic microchips.

Molecular diagnostics is being revolutionized by the completion of the human genome project and by the development of highly advanced technologies for DNA testing. One of the most important challenges is the introduction of high throughput systems such as DNA chips into diagnostic laboratories. DNA microchips are small devices permitting rapid analysis of genetic information, exploiting miniaturization of all components and automation of operational procedures. The most important biochip applications include gene expression and genetic variation identification and both may improve human molecular diagnostics. Here we review several approaches developed to allow rapid detection of many single nucleotide polymorphisms and mutations in large population samples. Among these, the use of microelectronics seems to best fit with the needs of molecular diagnostics.

Gene Expression Profiling↗

A two-center evaluation of the blood gas immediate response mobile analyzer (IRMA).

The Immediate Response Mobile Analyzer (IRMA) is a selective and portable point-of-care testing (POCT) blood gas, electrolyte and hematocrit (Hct) analyzer. The overall analytical performance was evaluated in a two-center study involving two Italian hospital laboratories, following the guidelines suggested by the manufacturer (based on the NCCLS protocol), after a preliminary evaluation of their formal validity. The IRMA was compared to the analyzers used in the routine laboratory as reference. The considered parameters were pH, pO2, pCO2, Na+, K+, ionized calcium and Hct. When using the aqueous quality control material provided by the manufacturer most of the parameters showed good precision, with the exception of pCO2 and pO2 that showed high CVs on two of the three levels of the aqueous control. We could demonstrate that this imprecision was material-related and was reduced when using a different material (blood equilibrated by tonometry). With tonometred blood for pO2 and pCO2 and the aqueous material for the remaining parameters the CVs were all below 5%, ranging from 0.08% to 2.8%. The IRMA results correlated adequately with the comparison instruments, with the exception of sodium and ionized calcium where contradictory results were obtained in the two centers.

Blood Gas Analysis↗

Errors in laboratory medicine.

BACKGROUND: The problem of medical errors has recently received a great deal of attention, which will probably increase. In this minireview, we focus on this issue in the fields of laboratory medicine and blood transfusion. METHODS: We conducted several MEDLINE queries and searched the literature by hand. Searches were limited to the last 8 years to identify results that were not biased by obsolete technology. In addition, data on the frequency and type of preanalytical errors in our institution were collected. RESULTS: Our search revealed large heterogeneity in study designs and quality on this topic as well as relatively few available data and the lack of a shared definition of "laboratory error" (also referred to as "blunder", "mistake", "problem", or "defect"). Despite these limitations, there was considerable concordance on the distribution of errors throughout the laboratory working process: most occurred in the pre- or postanalytical phases, whereas a minority (13-32% according to the studies) occurred in the analytical portion. The reported frequency of errors was related to how they were identified: when a careful process analysis was performed, substantially more errors were discovered than when studies relied on complaints or report of near accidents. CONCLUSIONS: The large heterogeneity of literature on laboratory errors together with the prevalence of evidence that most errors occur in the preanalytical phase suggest the implementation of a more rigorous methodology for error detection and classification and the adoption of proper technologies for error reduction. Clinical audits should be used as a tool to detect errors caused by organizational problems outside the laboratory.

Blood Transfusion↗