Search PubMed⌕ Search

Biomedical subjects

Pierangela Palma

Publications and source records attributed to Pierangela Palma.

10 recordsLinked to original sources

Determination of endocrine disrupting compounds in marine water by nanoliquid chromatography/direct-electron ionization mass spectrometry.

We present a new method for the determination of 29 endocrine-disrupting compounds in marine water. This method is based on a solid-phase extraction preconcentration technique, followed by a nanoscale liquid chromatography/direct-electron ionization (EI) mass spectrometric analysis. Direct-EI is a novel technique for the rapid conversion of a GC/MS into an efficient and reliable LC/MS for EI detection. The capability to acquire EI mass spectra of the analytes, and to operate in selected ion monitoring mode during real sample analyses, allows certain identification and precise quantification. In addition, this method is not influenced by the polarity of the analytes and does not require different detection modes (positive and negative) for identification with API techniques. Limits of detection of the method span from 0.4 to 118.7 ng.L(-1), corresponding to an instrumental detection limit of 0.005-1.260 ng. Linear regression and recovery experiment data, together with their standard deviations, are also presented. Marine water samples were collected along the middle-western Adriatic Coast (Italy), near the shore and at the mouth of rivers and canals.

Chromatography, Liquid↗

LC-MS/MS analysis of peptides with methanol as organic modifier: improved limits of detection.

With the advent of soft ionization methods such as MALDI and ESI, mass spectrometry has become the most important technique for the analysis of proteins and peptides. ESI-MS is often preceded by separation of the peptide sample by reversed-phase liquid chromatography (LC). Acetonitrile (ACN) is the most commonly employed organic solvent in LC-ESI-MS analysis of peptides. In this report, we demonstrate that the use of methanol (MeOH) as the organic modifier improves the detection limits for analysis of peptide mixtures such as those found in tryptic digests of proteins. A nanoLC-ESI-quadrupole ion trap instrument (LCQ Deca, ThermoFinnigan) was used to analyze peptide standards, protein digests of known concentrations, and tryptic digests of 2-DGE-separated proteins. MeOH displayed excellent chromatographic performance (separation and sensitivity), and shorter gradient times were possible for chromatographic separation with MeOH versus ACN. Sensitivity levels of a few hundred attomoles were achieved with MeOH; those levels could not be achieved with ACN. In addition, MeOH-based nanoLC-MS/MS yielded superior results for the analysis of digests of 2-DGE-separated proteins. For the 14 protein spots analyzed, the success rate of protein identification with MeOH-based nanoLC-ESI-MS/MS was 100%, with multiple proteins identified in several of the spots. In contrast, ACN-based procedure failed to identify any proteins in 21% of the spots and overall identified 33% fewer proteins than the MeOH-based procedure. In summary, higher sensitivity and shorter gradient times make MeOH an excellent organic modifier for the use in nanoLC-ESI-MS/MS analysis of peptides.

Chromatography, Liquid↗

Identification of levoglucosan and related steroisomers in fog water as a biomass combustion tracer by ESI-MS/MS.

A conspicuous fraction of the water soluble organic compounds (WSOC) in fog and fine aerosol samples is composed by monosaccharide anhydrides, such as levoglucosan and its stereoisomers, galactosan and mannosan. Levoglucosan is produced exclusively during wood combustion processes, making it a very useful tracer for plant combustion emissions in the atmosphere. This paper describes a new experimental approach, based on electrospray-tandem mass spectrometry (ESI-MS/MS), for the identification of levoglucosan in fog water samples. The analytical method proposed allows to identify the specific sugar anhydrides directly in the liquid phase without the need of any derivatization process.

Aerosols↗

Variable-gradient generator for micro- and nano-HPLC.

A new, simple device generates accurate nano- and microflow rate gradients from any conventional HPLC system. The core of the new device is represented by an electric-actuated, computer-controlled, multiposition HPLC valve. The valve hosts six reservoirs for as many different mobile-phase compositions of increasing strength. A low flow rate stream pushes the weakest solvent through the column as long as required and at the desired flow rate, until the chromatographic run is started. From this time on, the electric actuation allows one to select which reservoir will be on-line with the column and for how long, thus generating a specific solvent gradient, through a sequence of controlled segments of precise mobile-phase composition. This permits one not only to exactly reproduce the programmed slope but also to achieve different gradient shapes (i.e., linear, convex, concave) for different separation needs. The new device has proven to be reliable and reproducible even at the lowest flow rate tested (250 nL x min(-1)) and in different chromatographic conditions.

Journal Article↗

Trace level determination of organophosphorus pesticides in water with the new direct-electron ionization LC/MS interface.

A new LC/MS method for the determination of organophosphorus pesticides in water, based on the use of direct-electron ionization (EI) interface, is presented. Direct-EI is a new device that, in a very simple fashion, couples a nano-HPLC system with a mass spectrometer equipped with electron ionization capability. The nanoscale liquid flow allows for a direct introduction of eluate into the ion source and, after nebulization, for its ionization under typical EI conditions. Library-matchable EI spectra are generated for a choice of full scan or SIM detection of the analytes. In our case, a selection of organophosphorus pesticides, commonly distributed in local sugar beet cultivation, were considered. The new interface permits a very sensitive detection of the analytes in a wide range of linear response (0.09-9 ng). When applied to a real sample, the method allowed detecting four different pesticides at a concentration level of approximately 3 ng x L(-1).

Chromatography, High Pressure Liquid↗

A simple approach for coupling liquid chromatography and electron ionization mass spectrometry.

A miniaturized, aerosol based interface for directly coupling a liquid chromatograph with a mass spectrometer is presented. The interface is entirely within the electron ionization (EI) source of the mass spectrometer and no additional, external devices are needed. This simple and effective approach exploits micro-flow nebulization technology providing a new interface suitable for a variety of applications of environmental and biological interest. The new interface provides necessary linearity, ruggedness, sensitivity, and reproducibility of response for trace level analysis, and readily interpretable mass spectra for unambiguous identification of unknown compounds of small to medium molecular weight.

Journal Article↗

Liquid chromatography-electron ionization mass spectrometry: fields of application and evaluation of the performance of a Direct-EI interface.

A comprehensive evaluation and a thorough discussion of the fields of possible applications of the Direct-EI interface are described in this review. Direct-EI allows the direct introduction of the effluent from a capillary HPLC column into the electron ionization (EI) ion source of a mass spectrometer. Thanks to the reduced liquid intake and an in-source nebulizer, the interfacing process occurs smoothly and entirely into the ion source. No intermediate interfacing mechanisms of any sort are interposed between the column and the mass spectrometer, thus circumventing any undesired sample loss and minimizing the effort for instrument modification. Theoretically, any GC-MS system can be converted into an LC-MS for EI amenable compounds. Several parameters, crucial for a successful integration of liquid chromatography and mass spectrometry, have been considered in the evaluation of the functioning of such an interface: limit of detection, linearity of response, reproducibility, and chromatographic compatibility. Different mobile phases, also containing non-volatile buffers, were taken into account, demonstrating an outstanding separation flexibility. The entire set of experiments was carried out at different flow rates and temperatures of the ion source. The interface behavior was also tested in real world applications, with mixtures of pesticides, hormones, nitro-PAH, and endocrine-disrupting compounds, allowing picogram level detection and the possibility to record library-matchable, readily interpretable electron ionization mass spectra, for prompt compound characterization and confirmation.

Chromatography, High Pressure Liquid↗

New liquid chromatography/electron ionization mass spectrometry methods in water analysis.

A method to extract and analyze organic compounds from water is presented. A solid phase micro-trap (micro-SPE) directly connected to the micro-analytical column is used. Sensibility and specificity needed for trace analysis are guaranteed by mass spectrometric electron ionization (EI) detection. A new micro-HPLC/EI-MS interface called Capillary-EI (Cap-EI) is described. The ultimate evolution of this interface is also presented: in this extremely simplified interface the analytes are nebulized, vaporized and ionized in the small volume of the ion source. This interface, called Direct-EI, exploits nano- and micro-HPLC columns with a mobile phase flow rates ranging from 0.3 to 1.5 microL/min. Contemporary use of micro SPE, Cap-EI or Direct-EI gives us a powerful technique to identify and quantify organic pollutants at part per billion level (ppb).

Chromatography, High Pressure Liquid↗