Search PubMed⌕ Search

Biomedical subjects

Philippe Zeitoun

Publications and source records attributed to Philippe Zeitoun.

7 recordsLinked to original sources

Submicrometer digital in-line holographic microscopy at 32 nm with high-order harmonics.

Soft-x-ray digital in-line microscopic holography is achieved using a fully coherent high-order harmonic source emitting at 32 nm. Combination of commercial-grade soft-x-ray optics and a back-illuminated CCD detector allows a compact and versatile holographic setup. Different experimental geometries have been tested by imaging calibrated 50 nm tips and 1 microm wires. Spatial resolution of 800 nm is measured with magnifications ranging from 30 to 110 and a numerical aperture around 0.01. Finally, the potentiality of three-dimensional numerical reconstruction from a single hologram acquisition is shown experimentally.

Journal Article↗

Design and characterization of extreme-ultraviolet broadband mirrors for attosecond science.

A novel multilayer mirror was designed and fabricated based on a recently developed three-material technology aimed both at reaching reflectivities of about 20% and at controlling dispersion over a bandwidth covering photon energies between 35 and 50 eV. The spectral phase upon reflection was retrieved by measuring interferences in a two-color ionization process using high-order harmonics produced from a titanium: sapphire laser. We demonstrate the feasibility of designing and characterizing phase-controlled broadband optics in the extreme-ultraviolet domain, which should facilitate the manipulation of attosecond pulses for applications.

Journal Article↗

Automatic alignment of a Kirkpatrick-Baez active optic by use of a soft-x-ray Hartmann wavefront sensor.

We present what we believe to be the first automatic alignment of a synchrotron beamline by the Hartmann technique. Experiments were performed, in the soft-x-ray range (E=3 keV, lambda=0.414 nm), by using a four-actuator Kirkpatrick-Baez (KB) active optic. A system imaging the KB focal spot and a soft-x-ray Hartmann wavefront sensor were used alternatively to control the KB optic. The beam corrected with the help of the imaging system was used to calibrate the wavefront sensor. With both closed loops, we focused the beam into a 6.8 microm x 9 microm FWHM focal spot.

Journal Article↗

Compression of attosecond harmonic pulses by extreme-ultraviolet chirped mirrors.

In the race toward attosecond pulses, for which high-order harmonics generated in rare gases are the best candidates, both the harmonic spectral range and the spectral phase have to be controlled. We demonstrate that multilayer extreme-ultraviolet chirped mirrors can be numerically optimized and designed to compensate for the intrinsic harmonic chirp that was recently discovered and that is responsible for temporal broadening of pulses. A simulation shows that an optimized mirror is capable of compressing the duration from approximately 260 to 90 as. This new technique is an interesting solution because of its ability to cover a wider spectral range than other technical devices that have already been proposed to overcome the chirp of high harmonics.

Journal Article↗

Longitudinal coherence measurements of a transient collisional x-ray laser.

We present what is to our knowledge the first longitudinal coherence measurement of a transient inversion collisional x-ray laser. We investigated the picosecond output of a Ni-like Pd x-ray laser at 14.68 nm generated by the COMET laser facility at the Lawrence Livermore National Laboratory. Interference fringes were generated with a Michelson interferometer setup in which a thin multilayer membrane was used as a beam splitter. We determined the longitudinal coherence for the 4d1S0 --> 4p1P1 lasing transition to be approximately 400 microm (1/e half-width) by changing the length of one interferometer arm and measuring the resultant variation in fringe visibility. The inferred gain-narrowed linewidth of approximately 0.29 pm is a factor of 4 less than previously measured in quasi-steady-state x-ray laser schemes.

Journal Article↗

Hartmann wave-front measurement at 13.4 nm with lambdaEUV/120 accuracy.

We report, for the first time to our knowledge, experimental demonstration of wave-front analysis via the Hartmann technique in the extreme ultraviolet range. The reference wave front needed to calibrate the sensor was generated by spatially filtering a focused undulator beam with 1.7- and 0.6-microm-diameter pinholes. To fully characterize the sensor, accuracy and sensitivity measurements were performed. The incident beam's wavelength was varied from 7 to 25 nm. Measurements of accuracy better than lambdaEUV/120 (0.11 nm) were obtained at lambdaEUV = 13.4 nm. The aberrations introduced by an additional thin mirror, as well as wave front of the spatially unfiltered incident beam, were also measured.

Journal Article↗

X-ray-ultraviolet beam splitters for the Michelson interferometer.

With the aim of realizing a Michelson interferometer working at 13.9 nm, we have developed a symmetrical beam splitter with multilayers deposited on the front and back sides of a silicon nitride membrane. On the basis of the experimental optical properties of the membrane, simulations have been performed to define the multilayer structure that provides the highest reflectivity-transmission product. Optimized Mo-Si multilayers have been successfully deposited on both sides of t he membrane by use of the ion-beam sputtering technique, with a thickness-period reproducibility of 0.1 nm. Measurements by means of synchrotron radiation at 13.9 nm and at an angle of 45 degrees provide a reflectivity of 14.2% and a transmission of 15.2% for a 60% s-polarized light, close to the simulated values. Such a beam splitter has been used for x-ray laser Michelson interferometry at 13.9 nm. The first interferogram is discussed.

Journal Article↗