Search PubMed⌕ Search

Biomedical subjects

Philip Marriott

Publications and source records attributed to Philip Marriott.

25 records · Page 2Linked to original sources

Simulation of elution profiles for two-dimensional dynamic gas chromatographic experiments.

The interconversion of E and Z isomers of acetaldoxime 1 and butyraldoxime 2 have been investigated by comprehensive two-dimensional dynamic gas chromatography (DGCxDGC) and computer simulation. Time-resolved cryogenic modulation is capable of revealing the precise isomeric ratio as a fine structure under the dynamic elution profile, which is characterized in one-dimensional experiments by a plateau formation or peak coalescence caused by interconversion of the isomers during the separation process. The chromatographic theoretical plate model has been extended for the computer simulation of comprehensive two-dimensional dynamic chromatographic experiments. A novel program, ChromWin 2D, based on the new algorithm has been developed for computer simulation to evaluate and predict the elution profiles of DGCxDGC experiments. ChromWin 2D allows the determination of rate constants and barriers of isomerization, epimerization, and enantiomerization processes occurring during chromatographic separations. The Eyring activation parameters of the E/Z and Z/E isomerization barriers in the presence of the stationary phase BP21 (poly(ethylene glycol) terephthalate terminated) were determined by temperature-dependent experiments between 80 and 90 degrees C for 1 and 70 and 130 degrees C for 2. The thermodynamic Gibbs free energy of the E/Z equilibrium of the isomers has been determined from the time-resolved chromatograms by cryogenic modulation. The method described here constitutes a new and important tool for the determination of isomerization barriers, which are of great interest, for example, for the quantitative determination of derivatized aldehydes, such as dinitrophenylhydrazine derivatives, in trace analysis.

Journal Article↗

Spherical coordinate representations of solvent composition for liquid chromatography method development using experimental design.

One of the major techniques used for the method development of ternary and quaternary high performance liquid chromatography (HPLC) systems has been to use mixture designs, often referred to as "Glajch's Triangle". This technique does not allow for the systematic and simultaneous optimization of other factors such as gradient time, pH and temperature that affect the quality of separations. An alternative approach is to use experimental designs. The condition, however, that the composition of all components of the mobile phase must total 100% presents a problem when trying to mathematically represent ranges of each mobile phase constituent of a ternary or quaternary system. A method is described here, based on spherical coordinate representations, that adheres to the constraints of the mobile phase composition and allows experimental designs, such as central composite and factorial designs, to be applied to the simultaneous optimization of the mobile phase composition. Other factors, in particular temperature and gradient time, can then be included in the design. As a result of applying these designs to the HPLC separation of phenols and corticosteroids, it was found necessary to include three-way interactions between experimental factors in the model. The significance of these interactions shows that they need to be considered in HPLC method development.

Adrenal Cortex Hormones↗

Separation of positional isomers by the use of coupled shape-selective stationary phase columns.

The successful separation of 2- and 3-methyl-substituted positional isomers of butanol, butyl acetate, and butanoic acid and its ethyl ester, is reported. These compounds are of interest in the study of wine flavour, however the separation of the 2- and 3-methyl isomers may present problems, and more so in the presence of the wine matrix components, when single capillary column gas chromatography (GC) is used. The strategy to achieve separation was based on the use of shape-selective cyclodextrin derivative (CDD) capillary columns (commonly referred to as chiral columns). These columns provide simultaneous resolution of the enantiomeric pairs of the 2-methyl isomers, and at the same time the ability to separate the 3-methyl isomer from the 2-methyl is achieved in all but the case of the ( S)-2- and 3-methylbutanol. The advantages of using shape-selective columns to perform this study is demonstrated, with coupling of two CDD columns giving improved separations of these compounds. Although these compounds are relatively volatile, cryogenic modulated comprehensive two-dimensional GC was shown to provide good pulsed peak profiles with chiral separation in the first dimension when a thicker film trapping column segment was employed. The components of interest were well separated from other wine matrix components.

Journal Article↗

Characterisation of lavender essential oils by using gas chromatography-mass spectrometry with correlation of linear retention indices and comparison with comprehensive two-dimensional gas chromatography.

Nine samples of lavender essential oil were analysed by GC-MS using low-polarity and polar capillary columns. Linear retention indices (LRI) were calculated for each component detected. Characterisation of the individual components making up the oils was performed with the use of an mass spectrometry (MS) library developed in-house. The MS library was designed to incorporate the chromatographic data in the form of linear retention indices. The MS search routine used linear retention indices as a post-search filter and identification of the "unknowns" was made more reliable as this approach provided two independent parameters on which the identification was based. Around 70% of the total number of components in each sample were reliably characterised. A total of 85 components were identified. Semi-quantitative analysis of the same nine samples was performed by gas chromatography (GC) with flame ionisation detection (FID). The identified components accounted for more than 95% of each oil. By comparing the GC-MS results with the results from the GCxGC-FID analysis of a lavender essential oil, many more components could be found within the two-dimensional separation space.

Chromatography, Gas↗

Effects of temperature and flow regulated carbon dioxide cooling in longitudinally modulated cryogenic systems for comprehensive two-dimensional gas chromatography.

Two different modes of temperature regulation in longitudinally modulated cryogenic systems (LMCSs) for comprehensive two-dimensional gas chromatography (GC x GC) were compared. Carbon dioxide was used as coolant. In the first mode of operation, the temperature of the trap was regulated to pre-set temperature using a digital temperature controller ("the constant temperature mode"). In the second, the temperature was regulated to a fixed negative offset to the oven temperature by using a constant flow of CO2 ("the constant flow mode"). A number of problems were occasionally observed using the constant temperature mode: (1) severe band broadening of high boiling analytes in the second dimension; (2) non-Gaussian reconstructed first-dimension peak profiles; (3) high background due to modulation of first-dimension column bleed. It was concluded that these problems were associated with inefficient solute remobilization at low LMCS trap temperatures (1 and 2) or large trap temperature fluctuations (3). These problems could be avoided or significantly reduced by using the constant flow mode. Best results were obtained as the trap temperature was kept about 70 degrees C below the oven temperature.

Carbon Dioxide↗

Influence of chromatographic conditions on separation in comprehensive gas chromatography.

Comprehensive gas chromatography (GC x GC) is now established as a powerful technique, which offers unprecedented separation power. For complex samples, the distribution of peaks in the two-dimensional (2D) space still may need to be optimised. Since temperature (T) is a critical variable, and compounds can be shifted in relative positions on column 1 arising from temperature program rate (rT) changes, and since retention in the second dimension, D2 (2tR) is likewise affected by the prevailing T (elution temperature; Te), then any factors which alter Te will affect the extent of separation in D2. Since temperature program and carrier gas velocity rate will affect the Te of the solutes, these two factors are considered in this paper. Apart from these two parameters, results of different stationary phase choice for the second dimension column as well as the second dimension column length are reported. rT is found to have the most profound impact on the Te of solutes and will be more likely to cause an inversion of elution order if such behaviour can occur. Peak widths and 2tR increase with a decrease in Te. On the other hand, flow-rate has less impact on peak widths and 2tR although Te is affected by a change in flow-rate. Specific solute-stationary phase interactions will cause the elution order of certain solutes to be altered, and may be observed when a different stationary phase is employed as the second column, depending on the solute-stationary phase separation mechanism. Experiments conducted on different second dimension column length showed that although a longer column will lead to better separations, wrap-around may confound the separation process and may cause the solutes from sequential modulation events to co-elute. Thus a suitable second dimension column phase and length must be employed in order to obtain good separation. The factors investigated in this study will cause different extents of changes in the solute elution order and solute separations, and will affect the 2D contour presentation.

Chromatography, Gas↗