Comparison of magnetocardiography and electrocardiography: a study of automatic measurement of dispersion of ventricular repolarization.

AIMS: There is some dispute over the clinical significance of dispersion of ventricular repolarization measurements from the electrocardiogram. Recent studies have indicated that multichannel magnetocardiograms (MCGs), which non-invasively measure cardiac magnetic field strength from many sites above the body surface, may provide independent information from ECGs about ventricular repolarization dispersion. For this study, magnetocardiography and electrocardiography were compared from automatic measurements of dispersion of ventricular repolarization. METHODS AND RESULTS: Dispersion of ventricular repolarization time was determined in MCGs and standard ECGs recorded simultaneously from 27 healthy volunteers and 22 cardiac patients. Two automatic techniques were used to determine the interval of ventricular repolarization. There were significant differences in ventricular dispersion between ECG and MCG measurements, with multichannel MCG greater than ECG by 52 (47) ms [mean (SD)] (P<0.00001) and 12-channel MCG greater by 17 (40) ms (P<0.004) across techniques and all subjects. Magnetocardiograms had the greater discriminating power between normal and cardiac patients with differences of 46 (18) ms (P<0.017) for multichannel MCG and 44 (16) ms (P<0.005) for 12-channel MCG, compared with 16 (7) ms (P<0.04) for ECG. CONCLUSION: Magnetocardiography has the power to discriminate regional cardiac conduction differences.

Electrocardiography↗

Analysis of surface electrocardiograms in atrial fibrillation: techniques, research, and clinical applications.

Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice. Neither the natural history of AF nor its response to therapy is sufficiently predictable by clinical and echocardiographic parameters. The purpose of this article is to describe technical aspects of novel electrocardiogram (ECG) analysis techniques and to present research and clinical applications of these methods for characterization of both the fibrillatory process and the ventricular response during AF. Atrial fibrillatory frequency (or rate) can reliably be assessed from the surface ECG using digital signal processing (extraction of atrial signals and spectral analysis). This measurement shows large inter-individual variability and correlates well with intra-atrial cycle length, a parameter which appears to have primary importance in AF maintenance and response to therapy. AF with a low fibrillatory rate is more likely to terminate spontaneously and responds better to antiarrhythmic drugs or cardioversion, whereas high-rate AF is more often persistent and refractory to therapy. Ventricular responses during AF can be characterized by a variety of methods, which include analysis of heart rate variability, RR-interval histograms, Lorenz plots, and non-linear dynamics. These methods have all shown a certain degree of usefulness, either in scientific explorations of atrioventricular (AV) nodal function or in selected clinical questions such as predicting response to drugs, cardioversion, or AV nodal modification. The role of the autonomic nervous system for AF sustenance and termination, as well as for ventricular rate responses, can be explored by different ECG analysis methods. In conclusion, non-invasive characterization of atrial fibrillatory activity and ventricular response can be performed from the surface ECG in AF patients. Different signal processing techniques have been suggested for identification of underlying AF pathomechanisms and prediction of therapy efficacy.

Atrial Fibrillation↗

Comparison of atrial signal extraction algorithms in 12-lead ECGs with atrial fibrillation.

Analysis of atrial rhythm is important in the treatment and management of patients with atrial fibrillation. Several algorithms exist for extracting the atrial signal from the electrocardiogram (ECG) in atrial fibrillation, but there are few reports on how well these techniques are able to recover the atrial signal. We assessed and compared three algorithms for extracting the atrial signal from the 12-lead ECG. The 12-lead ECGs of 30 patients in atrial fibrillation were analyzed. Atrial activity was extracted by three algorithms, Spatiotemporal QRST cancellation (STC), principal component analysis (PCA), and independent component analysis (ICA). The amplitude and frequency characteristics of the extracted atrial signals were compared between algorithms and against reference data. Mean (standard deviation) amplitude of QRST segments of V1 was 0.99 (0.54) mV, compared to 0.18 (0.11) mV (STC), 0.19 (0.13) mV (PCA), and 0.29 (0.22) mV (ICA). Hence, for all algorithms there were significant reductions in the amplitude of the ventricular activity compared with that in V1. Reference atrial signal amplitude in V1 was 0.18 (0.11) mV, compared to 0.17 (0.10) mV (STC), 0.12 (0.09) mV (PCA), and 0.18 (0.13) mV (ICA) in the extracted atrial signals. PCA tended to attenuate the atrial signal in these segments. There were no significant differences for any of the algorithms when comparing the amplitude of the reference atrial signal with that of the extracted atrial signals in segments in which ventricular activity had been removed. There were no significant differences between algorithms in the frequency characteristics of the extracted atrial signals. There were discrepancies in amplitude and frequency characteristics of the atrial signal in only a few cases resulting from notable residual ventricular activity for PCA and ICA algorithms. In conclusion, the extracted atrial signals from these algorithms exhibit very similar amplitude and frequency characteristics. Users of these algorithms should be observant of residual ventricular activities which can affect the analysis of the fibrillatory waveform in clinical practice.

Algorithms↗

Surface atrial frequency analysis in patients with atrial fibrillation: assessing the effects of linear left atrial ablation.

INTRODUCTION: Our group has shown previously that measurements of atrial frequency can be obtained from surface 12-lead ECG recordings of patients during atrial fibrillation (AF), using a combination of principal component and Fourier transform algorithms. Such measurements are reproducible over time and change with drug manipulation of the arrhythmia. AIMS: To determine whether linear left atrial ablation, using a combination of "roof" and "mitral isthmus" lines results in changes in surface atrial frequency during AF and to assess the contribution of each individual line when sited sequentially. METHODS AND RESULTS: Computerized recordings from 26 patients, who had undergone linear ablation procedures for AF, were reviewed. The atrial signal was extracted from the 12-lead ECG data by principal component analysis and the main frequency component identified using Fourier analysis. Atrial frequency before and after these two standard ablation lines was compared. Atrial frequency decreased significantly after the combination of roof and mitral isthmus lines (5.66 vs 5.15 Hz) and when either roof (5.61 vs 5.13 Hz) or mitral isthmus (5.89 vs 5.75 Hz) lines were sited first. However, only the roof line led to a significant reduction in atrial frequency when sited second (5.64 vs 5.49 Hz). CONCLUSIONS: Measurements of atrial frequency can be obtained from surface 12-lead ECG recordings during AF and change as predicted in response to linear left atrial ablation. This technique may be useful in assessing antiarrhythmic treatments for AF.

Adult↗

Effect of premature ventricular beats on manual and automatic repolarization measurements.

OBJECTIVE: To compare QT interval and QT dispersion in ventricular ectopic beats with measurements from the preceding and the immediately following sinus beats, and investigate differences between manual and automatic measurements. PATIENTS: Eleven chronic uremic patients. MAIN OUTCOME MEASURES: ECGs were recorded during hemodialysis treatment and 12-lead sections containing five consecutive beats were extracted, each containing four sinus beats and one centrally-positioned premature ventricular beat. QT measurements were performed both manually and with a computer-automated technique. RESULTS: T wave amplitude was greater in the ectopic beats compared to the sinus beats (0.61 +/- 0.18 vs. 0.23 +/- 0.06 mV, P <.001). The ectopic beats had a greater QT than the sinus beats when measured manually (415 +/- 35 ms vs. 386 +/- 28 ms, P <.001), or automatically (375 +/- 30 vs. 366 +/- 27 ms, P<.01). The sinus beats following the ectopics had a greater QT than the preceding sinus beats (400 +/- 27 vs. 386 +/- 28 ms, P<.001, manual; 382 +/- 24 vs. 366 +/- 27 ms, P<.001, automatic). Differences in QT dispersion were seen only between the ectopic and sinus beats (91 +/- 31 vs. 58 +/- 27 ms, P <.001, manual; 68 +/- 33 vs. 49 +/- 35 ms, P <.001, automatic). CONCLUSIONS: Manual measurement resulted in greater QT values than automatic measurement. Both techniques identified differences between sinus and ectopic beats. The ventricular ectopic beats resulted in an increase in the QT of the immediately following sinus beats. These results confirm the need to interpret QT measurements with care in the presence of ectopic beats.

Aged↗

Magnetocardiography for pharmacology safety studies requiring high patient throughput and reliability.

Recent guideline drafts of the International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) underline the necessity to test nonantiarrhythmic drugs for their potential to prolong the QT or the corrected QT (QTc) interval. The implementation of these guidelines requires a large amount of ECG measurements on animals and humans in preclinical and clinical phases of the drug development process. We propose the use of magnetocardiography (MCG) as a complementary method with particular advantages in high-throughput studies, where signal quality and reliability are key factors. Our proposal is based on a review of recent MCG studies investigating the repolarization phase and results of methodological work assessing QT interval parameters from the MCG. The applicability of MCG for pre-clinical in-vivo studies is demonstrated by the ease of measurement in unrestrained non-anesthetized rabbits, guinea pigs, and hamsters..

Animals↗

Surface atrial frequency analysis in patients with atrial fibrillation: a tool for evaluating the effects of intervention.

INTRODUCTION: The aims of this study were to evaluate (1) principal component analysis as a technique for extracting the atrial signal waveform from the standard 12-lead ECG and (2) its ability to distinguish changes in atrial fibrillation (AF) frequency parameters over time and in response to pharmacologic manipulation using drugs with different effects on atrial electrophysiology. METHODS AND RESULTS: Twenty patients with persistent AF were studied. Continuous 12-lead Holter ECGs were recorded for 60 minutes, first, in the drug-free state. Mean and variability of atrial waveform frequency were measured using an automated computer technique. This extracted the atrial signal by principal component analysis and identified the main frequency component using Fourier analysis. Patients were then allotted sequentially to receive 1 of 4 drugs intravenously (amiodarone, flecainide, sotalol, or metoprolol), and changes induced in mean and variability of atrial waveform frequency measured. Mean and variability of atrial waveform frequency did not differ within patients between the two 30-minute sections of the drug-free state. As hypothesized, significant changes in mean and variability of atrial waveform frequency were detected after manipulation with amiodarone (mean: 5.77 vs 4.86 Hz; variability: 0.55 vs 0.31 Hz), flecainide (mean: 5.33 vs 4.72 Hz; variability: 0.71 vs 0.31 Hz), and sotalol (mean: 5.94 vs 4.90 Hz; variability: 0.73 vs 0.40 Hz) but not with metoprolol (mean: 5.41 vs 5.17 Hz; variability: 0.81 vs 0.82 Hz). CONCLUSION: A technique for continuously analyzing atrial frequency characteristics of AF from the surface ECG has been developed and validated.

Aged↗

Comparison of automatic repolarization measurement techniques in the normal magnetocardiogram.

Multichannel MCG noninvasively measures cardiac magnetic field strength from many sites at the body surface, potentially providing useful regional information about ventricular repolarization. Previous work on ECGs has shown that automatic techniques for repolarization measurement are better than manual measurement at discriminating patients with cardiac conditions from normal subjects. Although automatic repolarization measurement techniques have been quantified for ECGs, no comparative data exists for the MCG. In this study four different automatic repolarization (QT) interval techniques for detecting T wave end in the MCG were compared. The influence of MCG filtering on the automatic algorithms was also quantified. MCGs were obtained at 49 sites over the heart from 23 normal subjects. Automatic measurements of the repolarization (QT) interval were made following the addition of different high pass (0.25, 0.5, 1 Hz) and low pass (100, 60, 40, 30 Hz) filters. There were consistent differences between automatic techniques in the unfiltered data amounting to greatest mean difference of 52.3 ms. Low pass filtering significantly increased the automatic repolarization (QT) interval relative to unfiltered measurement by 6.5 (3.2) ms (mean SD) for 100 Hz, 6.0 (3.0) ms for 60 Hz, 8.1 (3.2) ms for 40 Hz, and 8.8 (3.1) ms for 30 Hz across all techniques. High pass filtering significantly decreased the value by -2.6 (6.0) ms for 0.25 Hz, -5.5 (5.3) ms for 0.5 Hz, and -17.1 (7.8) ms for 1 Hz. Automatic measurements of repolarization (QT) in the MCG differ between techniques and are influenced by filtering. These effects should be considered when comparing results.

Analysis of Variance↗

Errors in repolarization measurement using magnetocardiography.

Multichannel magnetocardiography (MCG) noninvasively measures variations in magnetic field strength from many sites at the body surface, potentially providing useful regional information about ventricular repolarization. MCGs contain features similar to ECGs, and although errors associated with repolarization measurement have been quantified for ECGs, no comparative data exists for MCGs. In this study, errors in manual measurement of repolarization interval in the MCG were determined. Sixteen MCG channels and three ECG leads were recorded simultaneously in eight healthy subjects. Each recording was displayed in a random order on a computer screen, in presentations with different noise levels, time display widths, and amplitude display heights. In total, manual measurement of repolarization intervals in 2,048 (eight subjects x 16 channels x eight presentations x two repeats) MCGs were made by each of four analysts. Measured repolarization intervals were reduced by 3 ms when noise was added and by a further 3 ms when this noise was doubled. Intervals were shortened by 9 ms when the time display width was doubled and by a further 10 ms when the display width was doubled again. Measurements increased by 7 ms for a doubling of amplitude display height, equivalent to a doubling of T wave height. There were also consistent differences between analysts; amounting to a greatest mean difference of 24 ms. Display characteristics, added noise, and different analysts thus affect manual repolarization interval measurements in MCG. The errors detected demonstrate the importance of a standard presentation for repolarization measurement in the MCG.

Electrocardiography↗

Quantification of T wave shape changes following exercise.

T wave shape is increasingly used to provide insights into cardiac repolarization and, although shape is known to change as heart rate changes, there are no published quantitative clinical data. The aim of this study was to quantify these changes. Heart rate (HR), T wave amplitude, and two measures of T wave symmetry (SRarea--ratio of areas about the peak, SRtime--ratio of centrality of peak), were quantified over a period of 360 seconds following exercise in 20 healthy human subjects. As HR decreased, in all subjects the T wave became more asymmetrical (SRarea 20/20, SRtime 20/20, P < 0.0001). Resting reference HR and symmetry ratios were (mean +/- SD), HR 63 +/- 10 beat/min, SRarea 1.68 +/- 0.25, and SRtime 2.13 +/- 0.39. Fifty seconds postexercise, HR was significantly higher than reference at 92 +/- 11 beat/min (P < 0.0001), and symmetry ratios were significantly less at SRarea 1.04 +/- 0.15, SRtime 1.24 +/- 0.36 (P < 0.0001). Significant differences in HR and both symmetry ratios remained at 300 seconds postexercise. Amplitude increases had returned to their reference values at 300 seconds. T wave shape was significantly more symmetrical at higher HRs. These findings confirm qualitative reports of shape changes.

Adult↗

Effect of changes in heart rate and in action potential duration on the electrocardiogram T wave shape.

The mechanisms responsible for changes in T wave symmetry and amplitude with changes in heart rate and action potential duration were investigated. A computer model of normal left ventricular repolarization was used to simulate the T waves on the surface 12-lead ECG. The effect of heart rate changes was studied by varying the ratio between dispersion of repolarization (Disp) and action potential repolarization duration (APRD). With constant dispersion. as heart rate increases, APRD decreases and the ratio Disp/APRD increases. T waves were simulated while varying the Disp/APRD ratio from 3.6% to 100%. The T wave symmetry ratio measured from the areas either side of the peak (SRarea), the symmetry ratio from the times either side of the peak (SRtime) and the T wave amplitude (Tamplitude) were calculated from each simulated ECG. SRarea decreased from 1.42 to 0.77, SRtime from 1.75 to 1.04 and the Tamplitude increased from 0. 19 mV to 2.30 mV. The stability of results with variation in model characteristics was also investigated, by moving the heart +/- 20 mm on all three axes, rotating the heart axes by +/- 10 and by modifying all constants defining the action potential by +/- 5% and +/- 10%. T wave amplitude was sensitive to changes in heart position, as the heart was moved towards the body surface. However, T wave shape changed very little with heart position or rotation, with the SD of SRarea varying by less than 0.05 over an SRarea range of 0.65 for different values of Disp/APRD ratio. We have shown from our model that cardiac T waves increase in amplitude, and become more symmetric with their peaks becoming central as APRD shortens with increasing heart rate, agreeing with clinical observations. These results help to explain the T wave shape changes which occur when heart rate increases.

Action Potentials↗