Search PubMed⌕ Search

Biomedical subjects

Peter R C Gascoyne

Publications and source records attributed to Peter R C Gascoyne.

7 recordsLinked to original sources

Dielectrophoretic segregation of different human cell types on microscope slides.

A new method for preparing cells for microscopic examination is presented in which cell mixtures are fractionated by dielectrophoretic forces and simultaneously collected into characteristic zones on slides. The method traps cells directly from the suspending medium onto the slide, reducing cell loss. Furthermore, it exploits differences in the dielectric properties of the cells, which sensitively reflect their morphology. Because different cell types are trapped in characteristic zones on the slide, the technique represents an advance over existing methods for slide preparation, such as centrifugation and smears where cells are randomly distributed. In particular, the new method should aid in the detection of rare and anomalous cell subpopulations that might otherwise go unnoticed against a high background of normal cells. As well as being suitable for traditional microscopic examination and automated slide scanning approaches, it is compatible with histochemical and immunochemical techniques, as well as emerging molecular and proteomic methods. This paper describes the rationale and design of this so-called electrosmear instrumentation and shows experimental results that verify the theory and applicability of the method with model cell lines and normal peripheral blood subpopulations.

Cell Separation↗

Dielectrophoresis-based programmable fluidic processors.

Droplet-based programmable processors promise to offer solutions to a wide range of applications in which chemical and biological analysis and/or small-scale synthesis are required, suggesting they will become the microfluidic equivalents of microprocessors by offering off-the-shelf solutions for almost any fluid based analysis or small scale synthesis problem. A general purpose droplet processor should be able to manipulate droplets of different compositions (including those that are electrically conductive or insulating and those of polar or non-polar nature), to control reagent titrations accurately, and to remain free of contamination and carry over on its reaction surfaces. In this article we discuss the application of dielectrophoresis to droplet based processors and demonstrate that it can provide the means for accurately titrating, moving and mixing polar or non-polar droplets whether they are electrically conductive or not. DEP does not require contact with control surfaces and several strategies for minimizing surface contact are presented. As an example of a DEP actuated general purpose droplet processor, we show an embodiment based on a scaleable CMOS architecture that uses DEP manipulation on a 32 x 32 electrode array having built-in control and switching circuitry. Lastly, we demonstrate the concept of a general-purpose programming environment that facilitates droplet software development for any type of droplet processor.

Electrophoresis↗

Droplet-based chemistry on a programmable micro-chip.

We describe the manipulation of aqueous droplets in an immiscible, low-permittivity suspending medium. Such droplets may serve as carriers for not only air- and water-borne samples, contaminants, chemical reagents, viral and gene products, and cells, but also the reagents to process and characterise these samples. We present proofs-of-concept for droplet manipulation through dielectrophoresis by: (1). moving droplets on a two-dimensional array of electrodes, (2). achieving dielectrically-activated droplet injection, (3). fusing and reacting droplets, and (4). conducting a basic biological assay through a combination of these steps. A long-term goal of this research is to provide a platform fluidic processor technology that can form the core of versatile, automated, micro-scale devices to perform chemical and biological assays at or near the point of care, which will increase the availability of modern medicine to people who do not have ready access to modern medical institutions, and decrease the cost and delays associated with that lack of access.

Electrodes↗

Detection of cellular responses to toxicants by dielectrophoresis.

The dielectrophoretic (DEP) crossover method has been applied to the detection of cell responses to toxicants. Time and dose responses of the human cultured leukemia (HL-60) line were measured for paraquat, styrene oxide (SO), N-nitroso-N-methylurea (NMU) and puromycin. These toxicants were chosen because of their different predominant mechanisms of action, namely membrane free radical attack, simultaneous membrane and nucleic acid attack, nucleic acid alkylation, and protein synthesis inhibition, respectively. For all treatments, the specific membrane capacitance (C(mem)) of the cells decreased while the specific membrane conductance (G(mem)) increased in dose- and time-dependent manners. The DEP responses correlated sensitively with alterations in cell surface morphology, especially folds, microvilli, and blebs, observed by scanning electron microscopy. The DEP method was more sensitive to agents that had a direct action on the membrane than to agents for which membrane alterations were secondary. The responses to paraquat and SO, which directly damaged the cell membrane, could be detected 15 min after exposure, while those for puromycin and NMU, which acted on intracellular targets, could be detected after 30 min. The detection times and dose sensitivity results showed that the DEP method is much faster and more sensitive than conventional cell and higher organism viability testing techniques. The feasibility of producing small instruments for toxicity detection and screening based on cellular dielectric responses is discussed.

Cell Membrane↗

Membrane dielectric changes indicate induced apoptosis in HL-60 cells more sensitively than surface phosphatidylserine expression or DNA fragmentation.

The specific membrane capacitance and conductivity of mammalian cells, which reflect their surface morphological complexities and membrane barrier functions, respectively, have been shown to respond to cell physiologic and pathologic changes. Here, the effects of induced apoptosis on these membrane properties of cultured human promyelocytic HL-60 cells are reported. Changes in membrane capacitance and conductivity were deduced from measurements of cellular dielectrophoretic crossover frequencies following treatment with genistein (GEN). The apparent specific cell membrane capacitance of HL-60 cells fell from an initial value of 17.6+/-0.9 to 9.1+/-0.5 mF/m(2) 4 h after treatment. Changes began within minutes of treatment and preceded both the externalization of phosphatidylserine (PS), as gauged by the Annexin V assay, and the appearance of a sub-G1 cell subpopulation, as determined through ethidium bromide staining of DNA. Treatment by the broad spectrum caspase inhibitor N-benzyloxycarbony-Val-Ala-Asp(O-methyl)-fluoromethyketone (zVAD-fmk) did not prevent these early cell membrane dielectric responses, suggesting that the caspase system was not involved. Although membrane conductivity did not alter during the first 4 h of GEN treatment, it rose significantly and progressively thereafter. Finally, as the barrier function failed and the cells became necrotic, it increased by many orders of magnitude. The effective membrane capacitance and conductivity findings serve to focus attention on the membrane as a site for early participation in apoptosis. In conjunction with our prior reports of the use of dielectric methods for cell manipulation and separation, these results demonstrate that dielectrophoretic technologies should be applicable to the rapid detection, separation, and quantification of normal, apoptotic, and necrotic cells from cell mixtures.

Apoptosis↗

Particle separation by dielectrophoresis.

The application of dielectrophoresis to particle discrimination, separation, and fractionation is reviewed, some advantages and disadvantages of currently available approaches are considered, and some caveats are noted.

Electrochemistry↗

Automated electrorotation to reveal dielectric variations related to HER-2/neu overexpression in MCF-7 sublines.

PURPOSE: Electrorotation (ROT) is a technique that allows for determination of the dielectric properties of living cells when exposed to a rotating electric field. We evaluated the ROT behavior of MCF/neo and p185(neu) transfectancts MCF/HER2-11 and MCF/HER2-18 to investigate whether differences in HER-2/neu expression were associated with differences in dielectric properties in these cells. EXPERIMENTAL DESIGN: P185(neu) was measured by Western blotting in MCF/neo cells and HER-2/neu transfectants MCF/HER2-11 and MCF/HER2-18. ROT spectra and cell membrane-specific capacitance were obtained for each cell line. RESULTS: The mean cell membrane-specific capacitance values for MCF/neo, MCF/HER2-11, and MCF/HER2-18 were 2.09, 1.70, and 2.56 microF/cm(2), respectively. The mean specific capacitance for MCF/neo was significantly different from that for MCF/HER2-11 (P = 0.006) and that for MCF/HER2-18 (P = 0.007). CONCLUSIONS: ROT is sufficiently sensitive to detect variations in dielectric properties in breast cancer cell lines overexpressing p185(neu). These differences may be related to the morphological alterations determined by HER-2/neu overexpression.

Automation↗