Delivered dose and vascular response after beta-radiation for in-stent restenosis: retrospective dosimetry and volumetric intravascular ultrasound analysis.

BACKGROUND: Observations from previous intracoronary radiation therapy trials noted a considerable discrepancy between the prescribed radiation dose and the dose actually delivered. The aims of this study were to investigate the effect of actual delivered dose on vascular changes and to test the appropriateness of the current dose prescription. METHODS AND RESULTS: Serial volumetric intravascular ultrasound (IVUS) analysis was performed in 30 in-stent restenosis cases treated with a 40-mm (90)Sr/Y source train. The fixed dose was prescribed at 2 mm from the centerline of the source train (18.4 Gy at 2 mm for reference diameter < or =3.35 mm and 23 Gy for diameter > or =3.36 mm). Only stent segments with full radiation coverage and device injury were enrolled and divided into 2-mm-long subsegments (n=202). D(S90)EEM (the minimum dose absorbed by 90% of the external elastic membrane surface) was calculated as the delivered dose corresponding to each segment, assuming that the radiation catheter occupied the same position in the vessel as the IVUS catheter. Mean D(S90)EEM of 23.5+/-5.82 Gy (range 12.3 to 41.7 Gy) was delivered to these subsegments. Overall, intimal hyperplasia volume remained constant from postintervention to follow-up (2.23+/-1.10 to 2.32+/-1.09 mm3/m; P=NS). Regression analysis revealed there was no correlation between delivered dose intensity and changes in intimal hyperplasia volume. No particular dose-dependent complications were appreciated in this delivered dose range. CONCLUSIONS: The current dose-prescription protocol of (90)Sr/Y radiation to native in-stent restenosis lesions may provide substantial inhibition of neointimal reproliferation regardless of the actual delivered dose intensity.

Beta Particles↗

7-hexanoyltaxol-eluting stent for prevention of neointimal growth: an intravascular ultrasound analysis from the Study to COmpare REstenosis rate between QueST and QuaDS-QP2 (SCORE).

BACKGROUND: Inhibition of neointimal tissue growth has been demonstrated in preliminary human feasibility studies with a stent-based polymer sleeve delivering 7-hexanoyltaxol. The Study to COmpare REstenosis rate between QueST and QuaDS-QP2 (SCORE) trial is a human, randomized, multicenter trial comparing 7-hexanoyltaxol (QP2)-eluting stents (qDES) with bare metal stents (BMS) in the treatment of de novo coronary lesions. The purpose of this substudy was to evaluate the acute expansion property and long-term neointimal responses of qDES compared with BMS as assessed by intravascular ultrasound (IVUS). METHODS AND RESULTS: A total of 122 (qDES 66, BMS 56) patients were enrolled into the IVUS substudy. All IVUS images (immediately after the procedure and at 6-month follow-up) were analyzed at an independent core laboratory in a blind manner. At baseline, qDES achieved stent expansion similar to BMS. At follow-up, qDES showed reduced neointimal growth by 70% at the tightest cross section and by 68% over the stented segment (P<0.0001 for both), resulting in a significantly larger lumen in qDES than in BMS. Unlike intracoronary brachytherapy, there was no evidence of negative edge effects, unhealed dissections, or late stent-vessel wall malapposition over the stented and adjacent references segments in either group. CONCLUSIONS: Detailed IVUS analysis revealed that qDES had comparable acute mechanical and superior long-term biological effects to BMS. Although the long-term benefits and limitations of this technology require further investigation, the reduction in neointimal thickenings demonstrated that local delivery of 7-hexanoyltaxol through polymer sleeves augments conventional mechanical treatment of atherosclerotic disease.

Blood Vessel Prosthesis Implantation↗

Discrimination of early/intermediate and advanced/complicated coronary plaque types by radiofrequency intravascular ultrasound analysis.

Radiofrequency intravascular ultrasound (IVUS-RF) analysis, as an extension of conventional IVUS imaging, may provide more accurate plaque discrimination. Thirty-two autopsy atherosclerotic coronary arteries were investigated. Corresponding sectors in different plaques were matched by histologic and RF analysis. Histologic analysis utilized the American Heart Association plaque classification. The backscattered ultrasound RF signal was analyzed by fast-Fourier transform, providing the underlying frequency components of its power spectrum. The normalized backscattered signal power (in decibels [dB]) for frequencies between 15.3 and 40.3 MHz was then measured for plaque discrimination. Advanced/complicated plaque types showed a higher signal power at all frequencies than early/intermediate lesion types (p <0.001 to p = 0.005). Discrimination of advanced/complicated lesion types was best at 15.3 MHz, with a cut-off point of 2.5 dB (sensitivity 93%, specificity 79%), and second best at 17.6 MHz (sensitivity 87%, specificity 71%, cut-off point 1.9 dB). With conventional IVUS, plaque discrimination was weaker; the best sensitivity for diagnosing early/intermediate lesion types was reached for "soft plaque" (sensitivity 63%, specificity 73%). Compared with conventional IVUS, IVUS-RF can discriminate between advanced/complicated and early/intermediate coronary atherosclerotic lesions with relatively high sensitivity and specificity in vitro.

Cadaver↗

Late vascular response to repeat stenting for in-stent restenosis with and without radiation: an intravascular ultrasound volumetric analysis.

BACKGROUND: Re-stenting of in-stent restenosis (ISR) improves acute angiographic results. Methods and Results- Volumetric intravascular ultrasound analysis was performed in 70 ISR lesions that received either placebo (n=36) or (192)Ir radiation (n=34). ISR lesions treated by re-stenting were divided into 3 groups: old stent not re-stented (A), old/new stent overlap (B), and new stent only (C). ISR lesions treated without re-stenting were categorized as D. In placebo patients, postintervention lumen volume index (LVI) was significantly greater in re-stented segments B and C than in non-re-stented segment A (P<0.05).At follow-up, however, LVI was similar in all 4 segments secondary to the increased intimal hyperplasia (IH) reaccumulation within the re-stented segments. In patients treated with (192)Ir radiation, LVI was maintained from baseline to follow-up only in non-re-stented segments A and D. Conversely, there was a significant decrease in LVI in re-stented segments B and C (P<0.05). Qualitatively, 79% of patients in the irradiated group had stent struts with undetectable neointimal versus only 27% in the placebo group (P<0.001). Coefficient of variation of IH reaccumulation was greater in re-stented segments of (192)Ir patients (B=57.3% and C=58.9%) than in re-stented segments in placebo patients (B=27.3% and C 26.8%) and non-re-stented segments in irradiated patients. CONCLUSIONS: Additional lumen gain from re-stenting ISR lesions is counteracted by exaggerated neointimal proliferation in placebo patients. Maximum effectiveness and safety of radiation can be achieved for ISR lesions when treated without re-stenting. Thus, regardless of supplementary intravascular brachytherapy, repeat stenting strategies provided little long-term advantage.

Blood Vessel Prosthesis Implantation↗

Effect of local delivery of L-arginine on in-stent restenosis in humans.

To determine whether intramural administration of L-arginine reduces intimal thickening after optimal Palmaz-Schatz stent deployment in humans, 50 patients with native coronary artery disease who received a single Palmaz-Schatz stent were enrolled in this pilot study. Patients were randomized into 2 treatment groups: an L-arginine group (n = 25) and a saline group (n = 25). After stent deployment, L-arginine (600 mg/6 ml) or saline (6 ml) was locally delivered via the Dispatch catheter (Scimed) over 15 minutes. Serial angiography and intravascular ultrasound examinations (motorized pull-back at 0.5 mm/s) were performed before and after the procedure, and at 6-month follow-up. Measurements of stent area, lumen area, and neointimal area were computed within the stents at 1-mm intervals, by technicians who were blinded to the treatment assignment. Using Simpson's rule, stent, plaque, and lumen volumes, neointimal volume within the stent, and percent neointimal volume were measured before and after the procedure, and at 6-month follow-up. The 6-month volume data in quantitative coronary ultrasound showed that neointimal volume in the L-arginine group was significantly less than in the saline group (25 vs 39 mm(3); p = 0.049). Similarly, percent neointimal volume was significantly less in the L-arginine group at 6-month follow-up (17 +/- 13% vs 27 +/- 21%; p = 0.048). Thus, these results showed that local delivery of L-arginine reduces in-stent neointimal hyperplasia in humans, indicating that this approach may be a novel strategy to prevent in-stent restenosis.

Aged↗

Targeting the adventitia with intracoronary beta-radiation: comparison of two dose prescriptions and the role of centering coronary arteries.

PURPOSE: To compare by intravascular ultrasound (IVUS) the efficacy of delivering the prescribed dose to the adventitia between two commonly used dose prescriptions for intracoronary radiotherapy. METHODS AND MATERIALS: In 59 human postangioplasty coronary vessels, one IVUS cross-section (1 mm thick) with the highest plaque burden was used for creating dose-volume histograms with different hypothetical positions of the source. RESULTS: On average, prescription to 1 mm beyond lumen surface resulted in delivery of the prescribed dose (20 Gy +/- 20%) to a higher fraction of adventitial volume than with the prescription to 2 mm from the source, with source placed in vessel center, lumen center, or in the IVUS catheter position. Source placement in the lumen center resulted in a low dose heterogeneity to the adventitia and the least dose heterogeneity to the intima. CONCLUSIONS: Prescription to 1 mm beyond lumen surface appeared more effective in delivering the prescribed dose to the adventitia than the American Association of Physicists in Medicine (AAPM) recommended prescription to 2 mm from the source center. Moreover, centering the source in the lumen provides the better balance of effective adventitial targeting and intimal dose homogeneity. Modification of the current AAPM recommendation for dose prescription for intracoronary radiotherapy should be considered.

Analysis of Variance↗

Mechanisms of acute lumen gain following cutting balloon angioplasty in calcified and noncalcified lesions: an intravascular ultrasound study.

Several studies have shown that mechanisms for lumen enlargement following conventional balloon angioplasty (BA) consist of plaque reduction and vessel expansion. To assess the mechanisms of lumen enlargement after Cutting Balloon (CB) angioplasty, intravascular ultrasound images were analyzed in 180 lesions (89 CB and 91 BA). External elastic membrane (EEM) cross-sectional area (CSA), lumen CSA, and plaque plus media (P+M) CSA were measured before and after angioplasty. In the CB group, lower balloon pressure was utilized (P < 0.0001). DeltaP+M CSA was significantly larger (P = 0.02) and deltalumen CSA showed a trend toward being larger (P = 0.07) compared to BA group. For noncalcified lesions, CB resulted in a larger deltaP+M CSA (P < 0.05) and a smaller deltaEEM CSA (P = 0.10) than BA. For calcified lesions, deltalumen CSA was significantly larger in the CB group (P < 0.05) without significant differences in deltaEEM CSA and deltaP+M CSA. Dissections complicated with calcified lesions were associated with larger deltalumen CSA for the CB group. In conclusion, for noncalcified lesions, CB achieves similar luminal dimensions with larger plaque reduction and less vessel expansion compared to BA. On the other hand, for calcified lesions, the CB achieves larger lumen gain, especially in lesions with evidence of dissections.

Aged↗

Efficacy and feasibility of helixcision for debulking neointimal hyperplasia for in-stent restenosis.

The Helixcision system is a novel 6 Fr-compatible catheter designed to debulk tissue for in-stent restenosis lesions. The purpose of this study was to determine the efficacy and feasibility of this new system for removing neointimal hyperplasia. A total of 32 in-stent restenosis lesions in 32 patients were treated with helixcision followed by balloon angioplasty. Debulking efficacy was assessed with serial baseline intravascular ultrasound (IVUS) in a subset of 18 lesions. To investigate longitudinal efficacy, 3D analysis was also performed in 12 lesions with automated pullback to calculate average cross-sectional areas across the stent. Prior to procedure, the angiographic reference diameter was 2.60 +/- 0.46 mm. Immediately after procedure, minimum lumen diameter improved from 0.84 +/- 0.33 to 2.19 +/- 0.41 mm (P < 0.0001). IVUS showed a significant reduction of intimal area (IA) after helixcision (from 4.95 +/- 2.04 to 2.88 +/- 1.48 mm(2); P < 0.001). Adjunctive balloon angioplasty further improved lumen area (LA) mainly by stent expansion rather than IA reduction at the site of minimum lumen area. The degrees of IA reduction and LA improvement were closely similar in volumetric analysis. Thirty-day and 6-month clinical follow-up were available in 97% (n = 31) and 72% (n = 23) of the enrolled patients, respectively. At 30-day follow-up, no major adverse cardiac event was reported except for periprocedural CK elevation in two patients (6%). Target legion revascularization within 6 months was performed in six patients (26%). Preliminary results of helixcision indicate that this system is safe and feasible for the treatment of in-stent restenosis. The concordant results between 2D and 3D IVUS analyses suggest that this unique technology can achieve uniform longitudinal debulking throughout the stent. The long-term outcomes appeared to be favorable, considering the relatively diffuse lesion morphology.

Adult↗

Effects of transducer position on backscattered intensity in coronary arteries.

Acute myocardial infarction is a frequent cause of sudden death, and is typically initiated by the rupture of coronary artery plaques. The likelihood and severity of rupture are influenced by the plaque structures and components. Radiofrequency (RF) intravascular ultrasound (US) (IVUS-RF) measurements extend current IVUS imaging techniques and may eventually enable the in vivo identification of these features. However, IVUS-RF measurements are affected by the transducer's instantaneous position in the vessel. Specifically, backscattered intensity (BI) decreases as either the distance between the tissue and the transducer increases, or as the beam's angle of incidence on the tissue increases. IVUS-RF data were acquired from seven disease-free coronary arteries in vitro. The 0-dB level for BI was defined as the peak intensity of the reflection from a stainless-steel flat reflector at each distance. The baseline BI measured in adventitial tissue was -32.5 dB (at 0 degrees, 0 mm) with angle and distance dependencies of -0.172 dB/ degrees and -3.37 dB/mm. In contrast, the BI from combined intima and media was -38.2 dB with dependencies of -0.111 dB/ degrees and -4.46 dB/mm (p < 0.05 for all three parameters). Acknowledging and compensating for these effects may allow IVUS-RF to develop into a rapidly deployable tool for the clinical detection of vulnerable plaques and to monitor coronary artery disease progression and regression.

Adolescent↗

Impact of deep vessel wall injury and vessel stretching on subsequent arterial remodeling after balloon angioplasty: a serial intravascular ultrasound study.

BACKGROUND: Arterial remodeling has been shown to be responsible for lumen narrowing after nonstent interventions. METHODS: To examine the impact of deep vessel wall injury (DI) after balloon angioplasty on the subsequent vessel remodeling process, we performed serial intravascular ultrasound (IVUS) analysis in 47 native coronary artery lesions that underwent balloon angioplasty. An IVUS study was performed before and after balloon angioplasty and repeated at follow-up. Vessel and lumen area were measured at the narrowest site before intervention. Plaque area was calculated as vessel area minus lumen area. DI was defined as the presence of plaque/vessel wall fracture deep in the medial layer (sonolucent zone by IVUS) after angioplasty. RESULTS: After angioplasty, DI was present in 18 (38%, DI group) and absent in 29 (62%, non-DI group) of lesions. During follow-up, changes in vessel area in the DI group were significantly larger than in the non-DI group (P =.007). There were no significant differences in changes in plaque area. A trend toward greater late lumen loss was observed in the non-DI group (P =.05). In the DI group, changes in lumen area correlated better with changes in vessel area (r = 0.81, P <.0001) than with changes in plaque area (r = 0.32, P =.20). However, in the non-DI group, changes in lumen area correlated with changes in plaque area (r = -0.55, P =.002), but not with changes in vessel area (r = 0.30, P =.11). CONCLUSIONS: Deep vessel wall injury after balloon angioplasty is associated with the magnitude of the subsequent vessel remodeling process. The differences in the remodeling process may have implications regarding adjunctive therapies to prevent restenosis after balloon angioplasty.

Aged↗

Impact of vessel curvature on the accuracy of three-dimensional intravascular ultrasound: validation by phantoms and coronary segments.

BACKGROUND: Three-dimensional intravascular ultrasound (IVUS) is used for volumetric assessment of arteriosclerotic plaque burden and restenotic tissue at follow-up after coronary interventions. However, the accuracy of these measurements, especially in tortuous vessels, is unclear. METHODS: A commercially available electrocardiogram (ECG)-gated 3-dimensional-IVUS system was tested in volume-validated straight and curved hydrocolloid phantoms and in volume-validated coronary specimens. Catheter withdrawal (30 MHz, 3.2F) was triggered using standardized ECG source with 0.2-mm step intervals per cardiac cycle simulation. RESULTS: On the basis of automated phantom volume measurements, IVUS overestimated true phantom volume (relative error = [measured V - true V]/true V x 100) by a median of 0.9%, 0.25%, and 1.96% for straight, mildly curved, and severely curved segments, respectively. The true volume of the coronary specimens was overestimated by a median of 5.79%. CONCLUSION: A median percentage deviation of 3-dimensional-IVUS-measured volumes from the true volumes of less than 10% in phantoms and coronary artery segments can be achieved.

Coronary Artery Disease↗

New catheter-based technology for the treatment of restenosis.

Catheter-based vascular interventions have been in development worldwide for several decades, leading to remarkable progress in device technology. Mechanical interventional devices, such as angioplasty balloons, atherectomy devices, and stents, were invented and have contributed greatly to the treatment of atherosclerotic vascular stenosis. However, mechanical approaches do not effectively prevent subsequent intimal growth. Recently, several biological approaches, including radiation therapy and drug-eluting stents, have shown striking inhibition of intimal growth. These significant results are likely to change the treatment strategy in the field of interventional cardiology. Furthermore, additional catheter-based technologies for vascular interventions are presently being evaluated. These latest technologies designed to prevent intimal proliferation include intravascular sonotherapy, cryotherapy, photoangioplasty, and soft X ray. To date, intravascular sonotherapy has proven its efficacy in animal studies and safety in human studies. Cryotherapy, the application of cold thermal energy during angioplasty, enhances the acute effects of conventional dilation while decreasing the likelihood of restenosis. Photoangioplasty has a unique property based on its selective mechanism of action to treat atheromatous plaque. Soft X ray systems provide convenient device handling and well-controlled radiation dose. Some of these technologies may play an important role in vascular interventions in the near future.

Animals↗

Arterial response during cutting balloon angioplasty: a volumetric intravascular ultrasound study.

BACKGROUND AND PURPOSE: Previous studies have demonstrated that the mechanism of acute lumen enlargement after balloon angioplasty is a combination of vessel expansion and plaque redistribution, but not plaque compression. The purpose of this study was to clarify, from a three-dimensional aspect, the vascular response to cutting balloon angioplasty. METHODS: Serial intravascular ultrasound (IVUS) studies, including pre- and post-intervention, were performed in 36 native coronary lesions treated with the cutting balloon device. External elastic membrane (EEM), lumen, and plaque + media cross-sectional area were measured at 16-frame intervals (30 frames = 1 mm) over a lesion length of 16 mm with the center on the smallest pre-intervention lumen area. Volumetric calculations were based on Simpson's rule. RESULTS: EEM volume (261.16 +/- 89.59 vs. 279.59 +/- 85.92 mm3; p < 0.01) and lumen volume (106.48 +/- 37.83 v.s. 133.72 +/- 36.57 mm3; p < 0.01) significantly increased after cutting balloon angioplasty. Furthermore, the plaque + media volume throughout the lesion changed significantly after cutting balloon angioplasty (154.68 +/- 63.36 vs. 145.87 +/- 59.20 mm3; p < 0.01). The change in lumen volume correlated strongly with the change in EEM volume (r = 0.75; p < 0.01), but poorly with the change in plaque + media volume (r = 0.08; p = 0.64). Less longitudinal plaque redistribution was also observed throughout the vessel after angioplasty. CONCLUSION: The results of this study indicate that the predominant mechanism of lumen enlargement from cutting balloon angioplasty is vessel expansion, although total plaque mass reduction and longitudinal plaque redistribution do occur.

Aged↗

Acute coronary closure after stenting: a lesson from intravascular ultrasound.

Intravascular ultrasound (IVUS) is an imaging modality more sensitive for defining suboptimal stent deployment issues compared with conventional angiographic imaging. We report on a patient with unstable angina who underwent stent deployment using IVUS guidance. Despite an acceptable angiographic result, intrastent thrombus, incomplete expansion and an edge/marginal dissection were seen by IVUS examination. Both the incomplete expansion and the intrastent thrombus were successfully treated. The dissection, however, was not treated in the catheterization laboratory. This mechanical injury pattern at the stent edge led to vessel occlusion 4 h post-procedure.

Journal Article↗