Search PubMed⌕ Search

Biomedical subjects

Peter Haglund

Publications and source records attributed to Peter Haglund.

At least 19 recordsLinked to original sources

Selective pressurized liquid extraction of polychlorinated dibenzo-p-dioxins, dibenzofurans and dioxin-like polychlorinated biphenyls from food and feed samples.

Selective pressurized liquid extraction (PLE) of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (dl-PCBs) from various food and feed samples was performed with a selective PLE method previously developed for bulk PCBs. The method utilizes sulfuric acid impregnated silica inside the extraction cell to oxidize coextracted fat. Extractions were performed at 100 degrees C with n-heptane for 5 min in two cycles. Data obtained by selective PLE combined with gas chromatography/high-resolution mass spectrometry (GC-HRMS) were compared to concentrations derived from reference laboratories applying conventional sample preparation and GC-HRMS. Experiments performed on spiked vegetable oil, naturally contaminated crude fish oil and oil containing compound feed samples showed good results for these relatively simple matrices. The accuracy was generally +/-20% as compared to spiked levels or to values obtained by the reference laboratories. The precision, measured as the relative standard deviation (RSD) for 2,3,7,8-tetrachlorodibenzo-p-dioxin toxic equivalency values (TEQs), was below 10% in all cases. The method was also tested on naturally contaminated herring tissue, chicken tissue, pork tissue and sepiolitic clay, which all caused some trouble. It was observed that sufficient amounts of sodium sulfate should be used for dehydration of tissue samples and additionally, the cells should not be packed too dense in order to avoid suppressed extraction efficiency. Once this was attended to, satisfactory data could be obtained, except for sepiolithic clay. This study demonstrates that selective PLE can be applied with success to a number of food and feed matrices in analysis of PCDD/Fs and dl-PCBs. Since the fat removal step is on-line, the selective PLE method will reduce time and solvent consumption for sample preparation as compared to traditional clean-up.

Benzofurans↗

Characterization and classification of complex PAH samples using GC-qMS and GC-TOFMS.

The aim of this study was to compare the polycyclic aromatic hydrocarbon (PAH) contents in a number of complex samples, including soil samples from industrial sites, anti-skid sand, urban dust and ash samples from municipal solid waste incinerators. The samples were characterized by routine analysis of PAHs (gas chromatography-quadrupole mass spectrometry) and gas chromatography-time of flight mass spectrometry (GC-TOFMS). Classification of the samples by principal component analysis (PCA) according to their composition of PAHs revealed that samples associated with traffic and the municipal incinerator formed homogeneous clusters, while the PAH-contaminated soils clustered in separate groups. Using spectral data to resolve co-eluting chromatographic peaks, 962 peaks could be identified in the GC-TOFMS analysis of a pooled sample and 123-527 peaks in the individual samples. Many of the studied extracts included a unique set of chemicals, indicating that they had a much more diverse contamination profile than their PAH contents suggested. Compared to routine analysis, GC-TOFMS provided more detailed information about each sample and in this study a large number of alkylated PAHs were found to be associated with the corresponding unsubstituted PAHs. The possibility to filter peaks according to different criteria (e.g. to include only peaks that were detected in the analysis of another sample) was explored and used to identify unique as well as common compounds within samples. This procedure could prove to be valuable for obtaining relevant chemical data for use in conjunction with results from various biological test systems.

Gas Chromatography-Mass Spectrometry↗

Comparison of techniques for estimating PAH bioavailability: uptake in Eisenia fetida, passive samplers and leaching using various solvents and additives.

The aim of this study was to evaluate different techniques for assessing the availability of polycyclic aromatic hydrocarbons (PAHs) in soil. This was done by comparing the amounts (total and relative) taken up by the earthworm Eisenia fetida with the amounts extracted by solid-phase microextraction (SPME), semi-permeable membrane devices (SPMDs), leaching with various solvent mixtures, leaching using additives, and sequential leaching. Bioconcentration factors of PAHs in the earthworms based on equilibrium partitioning theory resulted in poor correlations to observed values. This was most notable for PAHs with high concentrations in the studied soil. Evaluation by principal component analysis (PCA) showed distinct differences between the evaluated techniques and, generally, there were larger proportions of carcinogenic PAHs (4-6 fused rings) in the earthworms. These results suggest that it may be difficult to develop a chemical method that is capable of mimicking biological uptake, and thus estimating the bioavailability of PAHs.

1-Butanol↗

Simultaneous extraction and fractionation of polycyclic aromatic hydrocarbons and their oxygenated derivatives in soil using selective pressurized liquid extraction.

In this study, a selective pressurized liquid extraction (PLE) method which can extract polycyclic aromatic hydrocarbons (PAHs) and their oxygenated derivatives (oxy-PAHs) from contaminated soil and simultaneously separate them into two fractions was developed. The method uses extraction cells packed with a chromatographic adsorbent and extraction solvents of increasing polarity. Several experiments were conducted on both spiked and authentic contaminated soil samples. Different types of adsorbents, combinations of extraction solvents, and extraction temperatures were tested in order to find a method that could fulfill the purpose of the study. The final method was based on extraction cells packed with 2% deactivated silica gel. The PAHs were extracted with cyclohexane/dichloromethane (9:1) at 120 degrees C, after which the oxy-PAHs where extracted with cyclohexane/dichloromethane (1:3) at 150 degrees C. The PAHs and oxy-PAHs were efficiently separated into two fractions, and only trace amounts of some compounds were found in the inappropriate fraction. The recoveries of the PAHs were mostly above 70% and of the oxy-PAHs, above 90%. The linearity of the method was good, and the calibration curves for most compounds had a regression coefficient better than 0.99 and an intercept close to the origin of coordinates. When the selective PLE method was applied to seven authentic soil samples, the results were found to be in good agreement with those of a reference method based on Soxhlet extraction and silica gel cleanup and also in good agreement with the certified reference values available for one of the soils. The selective PLE method is faster and consumes less solvent than a traditional method based on separate extraction and fractionation steps. The selective PLE method is, therefore, suitable for the concurrent analysis of PAHs and oxy-PAHs during large-scale soil contamination studies. This will provide more information about the soil contamination and the levels of toxicity than an ordinary PAH analysis.

Journal Article↗

Rapid screening of dioxin-contaminated soil by accelerated solvent extraction/purification followed by immunochemical detection.

Since soils at industrial sites might be heavily contaminated with polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs), there is a need for large-scale soil pollution surveys and, thus, for cost-efficient, high-throughput dioxin analyses. However, trace analysis of dioxins in complex matrices requires exhaustive extraction, extensive cleanup, and very sensitive detection methods. Traditionally, this has involved the use of Soxhlet extraction and multistep column cleanup, followed by gas chromatography-high-resolution mass spectrometry (GC/HRMS), but bioanalytical techniques may allow much more rapid, cost-effective screening. The study presented here explores the possibility of replacing the conventional method with a novel approach based on simultaneous accelerated solvent extraction (ASE) and purification, followed by an enzyme-linked immunosorbent assay (ELISA). Both the traditional and the novel cleanup and detection approaches were applied to contaminated soil samples, and the results were compared. ELISA and GC/HRMS results for Soxhlet-extracted samples were linearly correlated, although the ELISA method slightly underestimated the dioxin levels. To avoid an unacceptable rate of false-negative results, the use of a safety factor is recommended. It was also noted that the relative abundance of the PCDDs/PCDFs, evaluated by principal component analysis, had an impact on the ELISA performance. To minimize this effect, the results may be corrected for differences between the ELISA cross-reactivities and the corresponding toxic equivalency factor values. Finally, the GC/HRMS and ELISA results obtained following the two sample preparation methods agreed well; and the ELISA and GC/HRMS results for ASE extracts were strongly correlated (correlation coefficient, 0.90). Hence, the ASE procedure combined with ELISA analysis appears to be an efficient approach for high-throughput screening of PCDD-/PCDF-contaminated soil samples.

Benzofurans↗

The fate of chiral organochlorine compounds and selected metabolites in intraperitoneally exposed arctic char (Salvelinus alpinus).

The fate of chiral organochlorine compounds (OCs) and selected metabolites in exposed Arctic char (Salvelinus alpinus) was investigated. The contaminants alpha-hexachlorocyclohexane (alpha-HCH), cis-chlordane, 13C4-heptachlor, o,p'-DDT, and the atropisomeric chlorinated biphenyls (CBs) 95, 132, 136, 149, and 174 were solved in peanut oil and injected into the peritoneal cavity. The exposed fish were sampled three times during a five-week period, and the OC residues and detected metabolites (heptachlorexo-epoxide) were quantified in muscle and liver tissues by chiral and achiral gas chromatography-mass spectrometry and gas chromatography-electron-capture detection. Peak concentrations were reached after one to two weeks, and thereafter, the levels declined. At the end of the experiment, liver concentrations had decreased 76 to 92% relative to peak concentrations, whereas muscle concentrations showed a moderate decline (5-38%), with the exception of alpha-HCH (91%). Hydrophobicity and steric hindrance were shown to influence the assimilation process, and a significant linear relationship between the product of the steric hindrance coefficients and the inverse of the octanol-water partition coefficients (Kow) versus peak concentration was found for the CBs (r2 = 0.86, p = 0.02). The assimilation of the contaminants into muscle and liver tissues generally resulted in racemic mixtures, whereas elimination was enantioselective for alpha-HCH, cis-chlordane, o,p'-DDT, CB-132, and CB-136. The chiral heptachlor metabolite 13C4-heptachlor-exo-epoxide was formed in the fish. The enantiomeric composition of the formed metabolite indicated racemic formation, whereas the elimination process appeared to be enantioselective.

Animals↗

Organophosphorus flame retardants and plasticizers in Swedish sewage treatment plants.

The levels, distribution, and possible sources of 12 organophosphorus flame retardants and plasticizers, some of which are reported to be toxic to aquatic organisms, were investigated in samples of influents, effluents, and sludge from 11 Swedish sewage treatment plants (STPs). The organophosphorus compounds (OPs) studied were poorly removed from the wastewater; especially the chlorinated OPs tended to pass through the STPs without being removed or degraded, while alkyl-OPs, such as tributyl phosphate (TBP), were more successfully removed. In both influents and effluents, tris(2-butoxyethyl) phosphate and TBP were the most prominent substances followed by tris(2-chloroisopropyl) phosphate (TCPP). The highest concentration of any individual OP detected in the influents was 52 microg L(-1) (TBP). Ethylhexyl diphenyl phosphate and TCPP dominated in all sludge samples. A budget calculation comparing the annual amount of OPs in the influent received by Swedish STPs with the known amount of OPs imported indicated that approximately 15% is emitted to STPs. Of the total amount of OPs reaching the STPs annually, 49% is degraded, 50% (27 tons) is emitted to the recipients, and only 1% ends up in the sludge. The concentrations of most OPs were quite similar among the sampled STPs, indicating that the data may be applicable in other STPs.

Chromatography, Gas↗

Trace analysis of polychlorinated dibenzo-p-dioxins, dibenzofurans and WHO polychlorinated biphenyls in food using comprehensive two-dimensional gas chromatography with electron-capture detection.

Trace analysis of 2,3,7,8-polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs) and the 12 WHO-PCBs (four non-ortho and eight mono-ortho congeners that have been assigned toxic equivalence factors, TEFs, by the World Health Organisation) was conducted by comprehensive two-dimensional gas chromatography with a micro electron-capture detector (GC x GC-microECD). Four food matrices (fish oil from herring, spiked cows' milk, vegetable oil and an eel extract) were analysed by two GC x GC laboratories, and four GC-HRMS laboratories generated reference values. The two GC x GC laboratories used different column combinations for separating the target analytes. For the first dimension, non-polar DB-XLB and VF-1 columns were used, and for the second dimension, an LC-50 liquid crystalline column with unique selectivity for planar compounds. The congener-specific and total toxic equivalence (TEQ) data obtained using DB-XLB x LC-50 were in good agreement with results obtained by the GC-HRMS laboratories. The WHO-PCB data obtained with the VF-1 x LC-50 combination was also good, but the PCDD/F concentrations were sometimes overestimated due to matrix interferences. GC x GC-microECD using DB-XLB x LC-50 seems to fulfil the European Community requirements of a screening method for PCDD/F and WHO-PCB TEQ in food.

Benzofurans↗

Organophosphorus flame retardants and plasticizers in air from various indoor environments.

Eleven organophosphorus compounds (OPs) that are used as plasticizers and flame retardants were analysed in duplicate samples of indoor air from 17 domestic and occupational environments. Solid-phase extraction (SPE) columns were used as adsorbents and analysis was performed using GC with a nitrogen phosphorus selective detector. The total amounts of OPs in the air samples ranged between 36 and 950 ng m(-3); tris(chloropropyl) phosphate (TCPP) and tris(2-chloroethyl) phosphate (TCEP) being the most abundant (0.4 to 730 ng m(-3)), followed by tributyl phosphate (0.5-120 ng m(-3)). Public buildings tended to have about 3-4 times higher levels of OPs than domestic buildings. The relative amounts of individual OPs varied between the sites and generally reflected the building materials, furniture and consumer products used in the sampled environments. Potential sources of these compounds include, inter alia, acoustic ceilings, upholstered furniture, wall coverings, floor polish and polyvinylchloride floor coverings. A correlation was observed between the TCEP concentrations in the air in the sampled environments and previously reported concentrations in dust, but no such correlation was seen for the heavier and less volatile tris(2-butoxyethyl) phosphate (TBEP). Based on estimated amounts of indoor air inhaled and dust ingested, adults and children in the sampled environments would be exposed to up to 5.8 microg kg(-1) day(-1) and 57 microg kg(-1) day(-1) total OPs, respectively.

Adult↗

Traffic as a source of organophosphorus flame retardants and plasticizers in snow.

Snow samples collected in northern Sweden at a road intersection and an airport indicated that traffic is a source of organophosphorus flame retardants and plasticizers (OPs) in the outdoor environment. Analysis of snow samples taken at distances of 2, 100, and 250 m from the road intersection showed that the total amount of OPs declined as distance increased. Of the 11 analyzed substances, tris-(2-chloroisopropyl) phosphate (TCPP) dominated in the snow samples from the intersection, with levels of 170, 130, and 110 ng/kg snow at distances of 2, 100, and 250 m. Similar amounts of TCPP were found at the airport (100-220 ng/kg). These levels are approximately twice as high as the level found in the reference snow sample from a remote area (70 ng/kg). A possible explanation for the higher levels of TCPP found close to the road intersection is that it may be emitted from the interior of cars via their ventilation systems. Triphenyl phosphate (TPP) was identified in lubricants and in waste oil from vehicles, and thus, leakage of transmission and motor oils is a probable source of TPP found at the sampled sites. Ten OPs were detected in the three samples from the airport, of which tributyl phosphate (TBP) was the most abundant, at levels 3 orders of magnitude higher than in the reference sample, that is, 25 000 compared to 19 ng/kg. The main source of TBP at the airport was traced to aircraft hydraulic fluid. Analysis of background air and deposition samples indicated that some OPs are subject to long-range air transportation.

Air Pollutants↗

Monitoring dioxins in food and feedstuffs using accelerated solvent extraction with a novel integrated carbon fractionation cell in combination with a CAFLUX bioassay.

The concentrations of dioxins in fish oil and fish meal were determined with accelerated solvent extraction, using a novel integrated carbon fractionation extraction cell followed by a miniturized multilayer silica column and bioanalysis on a recently-developed chemically-activated fluorescent gene expression cell bioassay. The developed method allows for simultaneous gravimetric lipid weight determination, which was shown for both matrices under study (about 100% lipid recovery of each sample). Initial results practically meet the quality criteria on screening methods for control of dioxins in food and feedstuffs laid down in the EU Commission Directives 2002/69/EC (food) and 2002/70/EC (feed). This demonstrates that the developed method can be used as a screening tool for monitoring dioxins in food and feed after some additional improvements and testing on a greater number of matrices.

Animals↗

Assessment of the availability of polycyclic aromatic hydrocarbons from gasworks soil using different extraction solvents and techniques.

This study was designed to assess the availability of polycyclic aromatic hydrocarbons (PAHs) present at a gasworks site to different soil remediation techniques. The study examined the effect on PAH availability of using different organic solvents, the degree of pretreatment, and the extraction time. In total, 25 PAHs (with two to six fused rings) and five carbonyl derivatives were measured. The results indicated that the PAHs and their derivatives were bound loosely to the surface of the studied soil and that there were no significant kinetic boundaries associated with the extraction of the PAHs. Furthermore, it was concluded that the studied soil was not suitable for bioremediation, as the concentration of PAHs with low molecular weight were limited. However, pressurized liquid extraction (PLE) with methanol as the solvent extracted 97% of all PAHs and PAH-derivatives, indicating that extraction may be effective as part of a soil remediation technique for old gasworks soils.

Biological Availability↗

Pressurised liquid extraction--comprehensive two-dimensional gas chromatography for fast-screening of polycyclic aromatic hydrocarbons in soil.

Pressurised liquid extraction (PLE) was applied to the extraction of polycyclic aromatic hydrocarbons (PAHs) from contaminated soils from Husarviken in Stockholm, Sweden. The extraction step was followed by conventional gas chromatography (GC), comprehensive two-dimensional gas chromatography (GC x GC) (both with flame ionisation detection) and gas chromatography-quadrupole mass spectrometry (GC-MS) analysis. Qualitative and quantitative aspects of the results are considered. Qualitatively, results from all chromatographic analyses are in good agreement, and PLE provides a reliable extraction technique with all PAHs extracted in one extraction step; no carry over was observed. With respect to PAH quantification, some variability in results was noted, with better agreement in PAH concentrations for GC and GC x GC measurement, as compared to GC-MS. GC analysis compares favourably with GC x GC apart from the few exceptions where peaks are not fully resolved from other co-extracted analytes, which compromises GC-FID measurement. For example, acenaphthene shows a much higher concentration when measured by GC-FID, demonstrating the superior separating powers of GC x GC; the latter is the preferred technique if precise and accurate quantification of analytes are required. GC-MS results compare reasonably with GC x GC for low-molecular mass PAHs but not for high-molecular mass PAHs; results for GC-MS are consistently higher than those for GC x GC for high-molecular mass PAHs. Since PLE-GC x GC is proposed as a broad screening tool, the demand for precise quantification may be relaxed in the present situation. GC x GC has the added advantage of providing chemical structural information within the two-dimensional contour presentation. Reproducibilities for GC x GC results (peak area) and 2tR were acceptable with relative standard deviations (R.S.D.) of 8 and 1%, respectively (at the mg/kg level), and good repeatability within samples was achieved.

Chromatography, Gas↗

Comprehensive two-dimensional gas chromatography of the 209 polychlorinated biphenyls.

Comprehensive two-dimensional gas chromatography (GC x GC) of the 209 polychlorinated biphenyls (CBs) was carried out using a longitudinally modulated cryogenic system (LMCS) and liquid carbon dioxide as cryogen. The effluent from a non-polar column was modulated and further separated on either a polar or a shape-selective second-dimension column. Five GC x GC column combinations were evaluated, with DB-XLB as the first column in each case. DB-XLB separates more congeners than any other GC column currently available. When combined with a biscyanopropyl siloxane (SP-2340 or BPX70) or smectic liquid crystal (LC-50) second-dimension column in a GC x GC system many additional CBs can be separated. In total, 176 and 181 of the 209 congeners were separated (Rs = 0.5) on the column combinations DB-XLB/SP-2340 and DB-XLB/LC-50, respectively. Of the 136 CBs present in any Aroclor mixture at concentrations greater than 0.05% (w/w), 126 were resolved using either of these two column combinations. The seven frequently measured CBs 28, 52, 101, 118, 138, 153, 180, and the WHO-PCBs 77, 81, 105, 114, 118, 123, 126, 156. 157, 167, 169 and 189 were all separated from Aroclor CBs on the DB-XLB/LC-50 column set, whereas CBs 118 and 131 coeluted on the DB-XLB/SP-2340 column set. In addition, three technical CB formulations (Aroclors 1232, 1248 and 1260) and a seal blubber sample (Halichoerus grypus) from the Baltic Sea were analyzed. Similar peak patterns were found for Aroclor 1260 and the CBs in the seal blubber, facilitating use of this technical CB formulation to identify the CBs in the blubber by GC x GC. Individual CBs in environmental samples, such as seal blubber, may be identified semi-automatically by matching the samples GC x GC profiles to a template generated using a standard containing all 209 CBs. Using such a template, 64 CBs were identified in the grey seal blubber sample.

Animals↗

Determination of atropisomeric and planar polychlorinated biphenyls, their enantiomeric fractions and tissue distribution in grey seals using comprehensive 2D gas chromatography.

High prevalence of uterine occlusions and sterility is found among Baltic ringed and grey seal. Polychlorinated biphenyls (CBs) are suspected to be the main cause. The CB concentrations are higher in affected than in healthy animals, but the natural variation is considerable. Thus, it might be possible to assess the health status of seals by CB analysis. The ratios of chiral compounds (enantiomeric fractions (EFs)) such as atropisomeric CBs are of particularinterest, since these may reflect differences in metabolic rates. An analytical procedure was developed and used to determine the levels of atropisomeric CBs, planar-CBs (WHO-PCBs) and total CBs in seals of different health status. Comprehensive 2D gas chromatography (GC x GC) was used to separate the target analytes from other CBs and interferences and a micro electron-capture detector (microECD) was used for detection. EFs of the atropisomeric CBs were difficult to determine as the levels were low and the interferences many. Two column combinations bad to be used to avoid biased results-both had a chiral column as first-dimension column. The second-dimension column was coated with either a high-polarity cyanopropyl or a liquid crystal phase. EFs were determined for five atropisomeric CBs, i.e. CBs 91,95, 132, 149 and 174. The results were verified by GC x GC-time-of-flight mass spectrometry (TOF-MS). Some atropisomeric CBs had EFs that deviated strongly from the racemic-mixture value. The deviations were larger in liver than blubber, which indicates enantioselective metabolism. However, there was no selective passage of the studied atropisomeric CBs across placenta and no selective blood-brain barrier. Similarly, no correlation between EFs and health status was observed, although there was a correlation between the total CB levels and health status.

Animals↗

A review of environmental toxicant analysis by using multidimensional gas chromatography and comprehensive GC.

The purpose of this review is to highlight the developments in coupled-column gas chromatography methods for qualitative analysis of selected environmental toxicants such as dioxin, polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), etc. In particular, the new technique of GC x GC will be introduced, and its role, and the promise it offers to this field is discussed. The benefits of enhanced separation to quantitative analysis will be considered. In order to perform an accurate risk assessment, both the dose and biological effects of environmental toxicants have to be determined with a high degree of certainty. This is most often achieved by using chromatographic methods. Given the complexity of most environmental sample extracts, single-column gas chromatography is unable to fully resolve all the components of interest frequently leading to a positive bias in the reported concentrations. Advanced separation tools, such as multidimensional gas chromatography (MDGC), were investigated quite early and demonstrated improvements in separation. However, limitations in the number of target analytes that could be analyzed in a single run as well as insufficient robustness lead to a continued interest in alternative solutions. The parallel development of mass spectrometric identification and quantification strategies proved useful in many cases, although it frequently failed to provide positive identification of chromatographically unresolved isomeric compounds. More recently, comprehensive two-dimensional gas chromatography (GC x GC) may offer a solution to that problem, especially because it offers enhanced resolution for complex mixtures containing trace level environmental toxicants.

Chromatography, Gas↗

Screening of organophosphorus compounds and their distribution in various indoor environments.

Twelve organophosphorus compounds (OPs), which are used for diverse purposes (e.g. as plasticizers and flame retardants), were analysed in settled house dust from 15 indoor environments and in wipe test samples from computer screens and covers. Seven of the substances analysed dominated Swedish imports of OPs in 1999, six of these are also listed as EU High Production Volume Chemicals. Eight of the substances were found in all samples. Tris(2-butoxyethyl)phosphate was the most abundant in most of the samples, with levels ranging from 0.014 to 5.3 g/kg followed by tris(2-chloroethyl)phosphate, tris(chloropropyl)phosphate and tris(1,3-dichloropropyl)phosphate. In wipe test samples from computers, triphenyl phosphate proved to be the main component of the OPs analysed (4.0 microg/m2). Potential sources of these compounds include, inter alia, floor polish, polyvinylchloride floor coverings, upholstery and plastic products. The distribution patterns of the OPs differed between the sites and generally reflected the building materials and consumer products used in their vicinity.

Chromatography, Gas↗

Degradation and formation of polycyclic aromatic compounds during bioslurry treatment of an aged gasworks soil.

The goals of this study were to investigate the relative degradation rates of polycyclic aromatic compounds (PACs) in contaminated soil, and to assess whether persistent oxidation products are formed during their degradation. Samples were taken on five occasions during a pilot-scale bioslurry treatment of soil from a former gasworks site. More than 100 PACs were identified in the soil, including unsubstituted polycyclic aromatic hydrocarbons (PAHs), alkylated PAHs (alkyl-PAHs), heterocyclic PACs, and oxygenated PAHs (oxy-PAHs), such as ketones, quinones, and coumarins. During the treatment, the low molecular weight PAHs and heterocyclics were degraded faster than the high molecular weight compounds. The unsubstituted PAHs also appear to have degraded more quickly than the corresponding alkyl-PAHs and nitrogen-containing heterocyclics. No new oxidation products that were not present in the untreated soil were identified after the soil treatment. However, oxy-PAHs that were present in the untreated soil were generally degraded more slowly than the parent compounds, suggesting that they were formed during the treatment or that they are more persistent. Two oxidation products, 1-acenaphthenone and 4-oxapyrene-5-one, were found at significantly higher concentrations at the end of the study. Because oxy-PAHs can be acutely toxic, mutagenic, or carcinogenic, we suggest that this group of compounds should also be monitored during the treatment of PAH-contaminated soil.

Biodegradation, Environmental↗