Search PubMed⌕ Search

Biomedical subjects

Peter Cloetens

Publications and source records attributed to Peter Cloetens.

8 recordsLinked to original sources

From homogeneous to fractal normal and tumorous microvascular networks in the brain.

We studied normal and tumorous three-dimensional (3D) microvascular networks in primate and rat brain. Tissues were prepared following a new preparation technique intended for high-resolution synchrotron tomography of microvascular networks. The resulting 3D images with a spatial resolution of less than the minimum capillary diameter permit a complete description of the entire vascular network for volumes as large as tens of cubic millimeters. The structural properties of the vascular networks were investigated by several multiscale methods such as fractal and power-spectrum analysis. These investigations gave a new coherent picture of normal and pathological complex vascular structures. They showed that normal cortical vascular networks have scale-invariant fractal properties on a small scale from 1.4 mum up to 40 to 65 mum. Above this threshold, vascular networks can be considered as homogeneous. Tumor vascular networks show similar characteristics, but the validity range of the fractal regime extend to much larger spatial dimensions. These 3D results shed new light on previous two dimensional analyses giving for the first time a direct measurement of vascular modules associated with vessel-tissue surface exchange.

Animals↗

Three-dimensional study of human dental fissure enamel by synchrotron X-ray microtomography.

The three-dimensional morphology of human tooth fissures and the quantification of mineral distribution in fissure enamel are pertinent to the development and diagnosis of caries. Synchrotron X-ray microtomography was used to measure linear attenuation coefficients (at 25 keV) at high spatial resolution with a volume-imaging element (cubic voxel) of 4.9x4.9x4.9 microm3 in a block from a human premolar that included part of a stained fissure. From the linear attenuation coefficient, the mineral concentration, expressed as gHAp cm-3 (where HAp is stoichiometric hydroxyapatite), was calculated. The mean mineral concentration in bulk enamel was 2.84 gHAp cm-3. Well-defined regions (1.5-2.6 gHAp cm-3), extending up to approximately 130 microm from the base of some narrower lengths of the fissure and up to approximately 50 microm deep from the fissure surface, were attributed to hypomineralization. Other regions of low mineral concentration, some (1.4-2.3 gHAp cm-3) lying within the expected course of the fissure base and some (2.2-2.7 gHAp cm-3) deep to the pit, were also considered to be of developmental origin. However, a diffuse distribution of low mineral concentrations (2.2-2.7 gHAp cm-3) in the pit walls was attributed primarily to demineralization from caries. The fissure contained heterogeneous material (<or=0.5 gHAp cm-3) exhibiting partial mineralization.

Dental Enamel↗

Phase-contrast X-ray imaging combining free space propagation and Bragg diffraction.

The combination of X-ray 'propagation-based' and 'analyzer-based' phase-contrast imaging with a perfect crystal-analyzer is investigated. The image pattern produced using this 'hybrid' imaging technique presents peculiar features that can be interpreted as a mixture of the two independent phase-contrast signals. A quantitative analysis has been performed in terms of signal-to-noise ratio for the three techniques considered in this paper. Results show that in the 'hybrid imaging' technique this parameter has a weaker dependence on the angular alignment of the crystal analyser with respect to the 'analyser-based' imaging. This pioneering experiment indicates that this hybrid imaging technique might permit simultaneous advantage of the specific features of the two imaging methods to be taken.

Absorption↗

Quantitative comparison between two phase contrast techniques: diffraction enhanced imaging and phase propagation imaging.

Two x-ray phase contrast imaging techniques are compared in a quantitative way for future mammographic applications: diffraction enhanced imaging (DEI) and phase propagation imaging (PPI). DEI involves, downstream of the sample, an analyser crystal acting as an angular filter for x-rays refracted by the sample. PPI simply uses the propagation (Fresnel diffraction) of the monochromatic and partially coherent x-ray beam over large distances. The information given by the two techniques is assessed by theoretical simulations and compared at the level of the experimental results for different kinds of samples (phantoms and real tissues). The imaging parameters such as the energy, the angular position of the analyser crystal in the DEI case or the sample to detector distance in the PPI case were varied in order to optimize the image quality in terms of contrast, visibility and figure of merit.

Breast Neoplasms↗

The partial Talbot effect and its use in measuring the coherence of synchrotron X-rays.

The Talbot effect is the self-imaging, at distances D multiple of D(R), of the intensity downstream of a periodic object. Earlier work with hard synchrotron radiation X-rays showed the variation with D of the fundamental Fourier component of intensity to be a good measurement of beam coherence. Any higher-order Fourier coefficients I (D, m > 1) would be periodic with a reduced period D(Rm) = D(R)/m for an ideally coherent incident beam (partial Talbot effect). The degree of coherence gamma(x) is sampled through the ratio of I (D, m) at D = 0 and multiples of D(Rm). This requires the Fourier coefficient for D = 0, which is not accessible for a phase object (no contrast at D = 0). However, the ratio of the slopes of I (D, m) at D = 0 and D = pD(Rm) also provides this information. Furthermore, a characterization of gamma(x) is possible, provided an assumption is made on its shape, using only the ratio of the Fourier coefficient I (D, m) of two images a distance pD(Rm) apart. Experiments with one- and two-dimensional phase gratings and a mixed (amplitude and phase) two-dimensional grating confirm that the partial Talbot effect approach is viable. It requires a reduced range of distances, and yields important results directly, obviating the need for computer fits. In particular, 8% of the beam intensity was found to have very low coherence in the vertical direction, probably due to monochromator imperfection.

Algorithms↗

An in vitro study of the ultrasonic axial transmission technique at the radius: 1-MHz velocity measurements are sensitive to both mineralization and intracortical porosity.

UNLABELLED: The ultrasonic axial transmission technique allows for investigating skeletal sites such as the cortical layer of long bones (radius, tibia, phalanges). Using synchrotron radiation microCT, we investigated, in vitro, the relationships between 1-MHz axial transmission SOS measurements at the radius and site-matched measurements of C.Th, POR, MIN, and vBMD. INTRODUCTION: The ultrasonic axial transmission technique allows for investigating skeletal sites such as the cortical layer of long bones (radius, tibia, phalanges). MATERIALS AND METHODS: Using synchrotron radiation microCT, we investigated, in vitro, the relationships between 1-MHz axial transmission speed of sound (SOS) measurements at the radius and site-matched measurements of cortical thickness (C.Th), intracortical porosity (POR), tissue mineralization (MIN), and volumetric BMD (vBMD). SOS measurements were based on bidirectional axial transmission and were performed with a 1-MHz proprietary probe on 39 excised human radii. RESULTS: The highest correlations between SOS values and bone parameters (R(2)(SOS/POR) = 0.28, p < 10(-3); R(2)(SOS/MIN) = 0.38, p < 10(-4); R(2)(SOS/vBMD) = 0.57, p < 10(-3)) were found for bone parameters assessed in a 1-mm-thick periosteal region of the cortex rather than throughout the whole cortex. The observed moderate correlation between SOS and C.Th values (R(2)(SOS/C.Th) = 0.20, p < 10(-2)) disappeared when controlled for other variables. The two best multilinear predictive models, including either BMD alone or the pair of dependent variables MIN and POR (all assessed in the periosteal cortex), were equally accurate in predicting SOS values (R(2)(SOS/(POR,MIN)) = 0.59, p < 10(-5); R(2)(SOS/vBMD) = 0.57, p < 10(-5)). CONCLUSION: For the first time, the respective adjusted contributions of POR (-24 m/s%(-1)) and tissue mineralization (+3.5 m/s/mg/cm(-3)) to SOS values were assessed. These results suggest potential sensitivity of axial transmission SOS values to changes in cortical bone status under different pathological conditions or treatments affecting POR and/or tissue mineralization.

Aged↗

Dispersion corrections of the copper K edge measured by Fresnel diffraction.

Dispersion corrections to the atomic scattering factors for the copper K edge have been measured by a new technique, Fresnel diffraction. Fresnel diffraction fringes were measured at several sample-detector distances as a function of energy across the copper K-absorption edge. The dispersion corrections were obtained from optimizing a least-squares fit of Fresnel fringe simulations to the measured data.

Journal Article↗

Quantification of the degree of mineralization of bone in three dimensions using synchrotron radiation microtomography.

The availability of three-dimensional measuring techniques coupled to specific image processing methods opens new opportunities for the analysis of bone structure. In particular, synchrotron radiation microtomography may provide three-dimensional images with spatial resolution as high as one micrometer. Moreover, the use of a monoenergetic synchrotron beam, which avoids beam-hardening effects, allows quantitative measurements of the degree of mineralization in bone samples. Indeed, the reconstructed gray levels of tomographic images correspond directly to a map of the linear attenuation coefficient within the sample. Since the absorption depends on the amount of mineral content, we proposed a calibration method to evaluate the three-dimensional distribution of the degree of mineralization within the sample. First a theoretical linear relationship modeling the linear attenuation coefficient as a function of the hydroxyapatite concentrations was derived. Then, an experimental validation on phantoms confirmed both the accuracy of the image processing tools and the experimental setup used. Finally, the analysis of the degree of mineralization in four iliac crest bone biopsy samples was reported. Our method was compared to the reference microradiography technique, currently used for this quantification in two dimensions. The concentration values of the degree of mineralization were found with both techniques in the range 0.5-1.6 g of mineral per cubic centimeter of bone, both in cortical and in trabecular region. The mean difference between the two techniques was around 4.7%, and was slightly higher in trabecular region than in cortical bone.

Bone Density↗