Search PubMed⌕ Search

Biomedical subjects

Peter Börnert

Publications and source records attributed to Peter Börnert.

24 records · Page 2Linked to original sources

Respiratory motion in coronary magnetic resonance angiography: a comparison of different motion models.

PURPOSE: To assess respiratory motion models for coronary magnetic resonance angiography (CMRA). In this study various motion models that describe the respiration-induced 3D displacements and deformations of the main coronary arteries were compared. MATERIALS AND METHODS: Multiple high-resolution 3D coronary MR images were acquired in healthy volunteers using navigator-based respiratory gating, each depicting the coronary vessels at different respiratory motion states. In the images representing the different inspiratory states the displacements and deformations of the main coronary vessels with respect to the end-expiratory state were determined, by means of elastic registration. Several correction models (superior-inferior (SI) translation, 3D translation, and 3D affine transformation) were tested and compared with respect to their ability to map a selected inspiratory to the end-expiratory motion state. RESULTS: 3D translation was found to be superior over SI translation, which is commonly used for prospective motion correction in CMRA. The 3D affine transformation was found to be the best correction model considered in this study. Furthermore, a large intersubject variability of the model parameters was observed. CONCLUSION: The results of this study indicate that a patient-adapted 3D correction model (3D translation or better 3D affine) will considerably improve prospective motion correction in CMRA.

Adult↗

Selective three-dimensional visualization of the coronary arterial lumen using arterial spin tagging.

Conventional coronary magnetic resonance angiography (MRA) techniques display the coronary blood-pool along with the surrounding structures, including the myocardium, the ventricular and atrial blood-pool, and the great vessels. This representation of the coronary lumen is not directly analogous to the information provided by x-ray coronary angiography, in which the coronary lumen displayed by iodinated contrast agent is seen. Analogous "luminographic" data may be obtained using MR arterial spin tagging (projection coronary MRA) techniques. Such an approach was implemented using a 2D selective "pencil" excitation for aortic spin tagging in concert with a 3D interleaved segmented spiral imaging sequence with free-breathing, and real-time navigator technology. This technique allows for selective 3D visualization of the coronary lumen blood-pool, while signal from the surrounding structures is suppressed.

Adult↗

Sensitivity-encoded single-shot spiral imaging for reduced susceptibility artifacts in BOLD fMRI.

Sensitivity encoding (SENSE) with iterative image reconstruction was used to shorten the readout duration in single-shot spiral imaging by a factor of 2. This enabled susceptibility-related blurring and signal loss artifacts to be reduced and spatial resolution to be improved. As a beneficial side effect, the gradient duty cycle was also reduced. The spiral SENSE technique was applied to functional MRI (fMRI) with blood oxygen level-dependent (BOLD) contrast and compared to a conventional spiral acquisition. Stimulation experiments were performed in seven volunteers using motor, visual, and taste paradigms. The signal-to-noise ratio (SNR) and signal-to-fluctuation-noise ratio (SFNR) of the SENSE acquisitions were reduced by 20% and 13%, respectively, with respect to the longer readout. The overall activation detected was comparable to that of the conventional spiral acquisition, even though difficulties in reproducing the stimulation response hampered the evaluation. In some cases, the application of SENSE enabled recovery of activation in regions affected by signal loss due to field inhomogeneity.

Artifacts↗

Model evaluation and calibration for prospective respiratory motion correction in coronary MR angiography based on 3-D image registration.

Image processing was used as a fundamental tool to derive motion information from magnetic resonance (MR) images, which was fed back into prospective respiratory motion correction during subsequent data acquisition to improve image quality in coronary MR angiography (CMRA) scans. This reduces motion artifacts in the images and, in addition, enables the usage of a broader gating window than commonly used today to increase the scan efficiency. The aim of the study reported in this paper was to find a suitable motion model to be used for respiratory motion correction in cardiac imaging and to develop a calibration procedure to adapt the motion model to the individual patient. At first, the performance of three motion models [one-dimensional translation in feet-head (FH) direction, three-dimensional (3-D) translation, and 3-D affine transformation] was tested in a small volunteer study. An elastic image registration algorithm was applied to 3-D MR images of the coronary vessels obtained at different respiratory levels. A strong intersubject variability was observed. The 3-D translation and affine transformation model were found to be superior over the conventional FH translation model used today. Furthermore, a new approach is presented, which utilizes a fast model-based image registration to extract motion information from time series of low-resolution 3-D MR images, which reflects the respiratory motion of the heart. The registration is based on a selectable global 3-D motion model (translation, rigid, or affine transformation). All 3-D MR images were registered with respect to end expiration. The resulting time series of model parameters were analyzed in combination with additionally acquired motion information from a diaphragmatic MR pencil-beam navigator to calibrate the respiratory motion model. To demonstrate the potential of a calibrated motion model for prospective motion correction in coronary imaging, the approach was tested in CMRA examinations in five volunteers.

Adult↗

Renal arteries: navigator-gated balanced fast field-echo projection MR angiography with aortic spin labeling: initial experience.

A cardiac-triggered free-breathing three-dimensional balanced fast field-echo projection magnetic resonance (MR) angiographic sequence with a two-dimensional pencil-beam aortic labeling pulse was developed for the renal arteries. For data acquisition during free breathing in eight healthy adults and seven consecutive patients with renal artery disease, real-time navigator technology was implemented. This technique allows high-spatial-resolution and high-contrast renal MR angiography and visualization of renal artery stenosis without exogenous contrast agent or breath hold. Initial promising results warrant larger clinical studies.

Adult↗

Correlation of 3D MR coronary angiography with selective coronary angiography: feasibility of the motion-adapted gating technique.

The aim of this study was to verify the feasibility of a respiratory motion compensation technique (motion-adapted gating, MAG) for visualization of coronary arteries (CA) by correlation with selective coronary angiography (SCA). Fifteen subjects (11 patients, mean age 61.3 years, age range 41-73 years; and 4 healthy volunteers, mean age 32.3 years, age range 31-35 years) were investigated. A Philips Gyroscan ACS-NT was used, operating at 1.5 T, was combined with the PowerTrak 6000 gradient system. An ECG-triggered, respiratory motion-gated 3D turbo field echo sequence was used. The real-time algorithm utilized the concept of k-space weighting in combination with automatic analysis of respiratory motion. The main CA were investigated. Qualitative analysis was performed by three blinded investigators. Visibility was graded on a five-point scale (0=not visualized, 1=insufficient, 2=sufficient, 3=good, 4=excellent). Segments graded 2-4 were defined as adequately visualized. Sixty-two of 88 assessable CA segments in patient, and 22 of 32 in volunteer group were adequately visualized. Visibility of CA was classified as excellent for proximal RCA (avg. 3.6+/-0.5), good for LM, proximal LAD, proximal LCX, middle RCA and sufficient for middle LAD. Sensitivity, specificity, positive and negative predictive values for coronary MRA in detection of CA stenoses with luminal narrowing >/=50% were 88, 94, 83, and 96%, respectively. Magnetic resonance imaging in combination with MAG has proven to be a promising technique for noninvasive imaging of CA due to good image quality and a patient convenient free-breathing technique.

Adult↗