The development of the Nucleus Freedom Cochlear implant system.

Cochlear Limited (Cochlear) released the fourth-generation cochlear implant system, Nucleus Freedom, in 2005. Freedom is based on 25 years of experience in cochlear implant research and development and incorporates advances in medicine, implantable materials, electronic technology, and sound coding. This article presents the development of Cochlear's implant systems, with an overview of the first 3 generations, and details of the Freedom system: the CI24RE receiver-stimulator, the Contour Advance electrode, the modular Freedom processor, the available speech coding strategies, the input processing options of Smart Sound to improve the signal before coding as electrical signals, and the programming software. Preliminary results from multicenter studies with the Freedom system are reported, demonstrating better levels of performance compared with the previous systems. The final section presents the most recent implant reliability data, with the early findings at 18 months showing improved reliability of the Freedom implant compared with the earlier Nucleus 3 System. Also reported are some of the findings of Cochlear's collaborative research programs to improve recipient outcomes. Included are studies showing the benefits from bilateral implants, electroacoustic stimulation using an ipsilateral and/or contralateral hearing aid, advanced speech coding, and streamlined speech processor programming.

Acoustic Stimulation↗

A psychophysical forward masking comparison of longitudinal spread of neural excitation in the Contour and straight Nucleus electrode arrays.

The objective of the study was to compare the widths of forward masking profiles in subjects implanted with the Nucleus 24 Contour or straight electrode array. The Contour array is typically positioned closer to the modiolus than the straight array. Subjects were fourteen postlingually hearing-impaired adults with severe-profound hearing loss, seven used the Contour array and seven used the straight array. Forward masking profiles were measured at three positions along the array (apical, mid, and basal) using maskers at the 15% loudness level. It was hypothesized that masking profile widths would be more sensitive to differences in distance from the neural structures using low-level maskers. Masking width was calculated at the 50% point of the masking peak amplitude. There were no significant differences in masking widths between Contour and straight array subject groups. Current levels for hearing thresholds and maximum comfortable listening levels were significantly lower for the Contour array subjects.

Acoustic Stimulation↗

Dual electrode stimulation using the nucleus CI24RE cochlear implant: electrode impedance and pitch ranking studies.

OBJECTIVE: The first aim of the study was to determine the reduction in electrode impedances using dual electrode stimulation compared with single electrode stimulation in the new Nucleus CI24RE receiver-stimulator. The CI24RE is connected to the Nucleus 22-electrode intracochlear array. Dual electrode stimulation is produced by electrically coupling two adjacent single electrodes. The second aim was to determine whether dual electrode stimulation produced pitch percepts that were intermediate to the pitch of the two adjacent single electrodes. DESIGN: Eight postlingually hearing-impaired adults with severe to profound loss, implanted with the CI24RE, participated in the study. Electrode impedances were measured by using the standard telemetry function of the system. A pitch ranking task was used to measure pitch for dual and single electrodes. Seven sets of three electrodes along the electrode array were tested. Each set of electrodes consisted of a dual electrode and the two adjacent single electrodes. Pitch ranking was measured using a two-alternative forced choice procedure, with the three electrodes in each set paired with each other as AB and BA pairs. The subject indicated which of the two stimuli had the higher pitch. Random variation in current level was used to remove any loudness cues. RESULTS: The average electrode impedance was 38.6% lower for dual electrodes compared with single electrodes. Three subjects were able to successfully rank the three electrodes in each set in the expected tonotopic order for all seven sets of electrodes along the array. Three other subjects were able to rank sets of electrodes in the tonotopic order for most of the tested positions on the array. The remaining two subjects gave more variable pitch ranking across positions along the array, although successful tonotopic ranking was demonstrated for several sets of electrodes. CONCLUSIONS: Dual electrode stimulation with the CI24RE receiver-stimulator produced systematically lower electrode impedances and was capable of producing pitch percepts that were intermediate to those produced by the corresponding adjacent single electrodes. This makes available up to 43 channels of stimulation from 22 single electrodes.

Adult↗

Cognitive processing in children using cochlear implants: the relationship between visual memory, attention, and executive functions and developing language skills.

We performed this study to determine whether children using a cochlear implant performed differently from age- and gender-matched hearing aid users on 8 neuropsychological measures of visual memory, attention, and executive functioning. The study also examined whether differences in cognitive skills could account for some of the observed variance in speech perception, vocabulary, and language abilities of hearing-impaired children. In contrast to previous studies, our results revealed no significant cognitive differences between children who use a cochlear implant and children who use hearing aids. Partial correlation analysis indicated that the children's visual memory skills, ie, their recognition memory, delayed recall, and paired associative learning memory skills, correlated significantly with their language skills. When examined at a significance level of .01, attention and executive functioning skills did not relate to the children's developing speech perception, vocabulary, or language skills. The results suggested that differences in visual memory skills may account for some of the variance seen in the language abilities of children using implants and children using hearing aids.

Adolescent↗