Search PubMed⌕ Search

Biomedical subjects

Pengyi Guo

Publications and source records attributed to Pengyi Guo.

4 recordsLinked to original sources

A practical three-dimensional dosimetry system for radiation therapy.

There is a pressing need for a practical three-dimensional (3D) dosimetry system, convenient for clinical use, and with the accuracy and resolution to enable comprehensive verification of the complex dose distributions typical of modern radiation therapy. Here we introduce a dosimetry system that can achieve this challenge, consisting of a radiochromic dosimeter (PRESAGE) and a commercial optical computed tomography (CT) scanning system (OCTOPUS). PRESAGE is a transparent material with compelling properties for dosimetry, including insensitivity of the dose response to atmospheric exposure, a solid texture negating the need for an external container (reducing edge effects), and amenability to accurate optical CT scanning due to radiochromic optical contrast as opposed to light-scattering contrast. An evaluation of the performance and viability of the PRESAGE/OCTOPUS, combination for routine clinical 3D dosimetry is presented. The performance of the two components (scanner and dosimeter) was investigated separately prior to full system test. The optical CT scanner has a spatial resolution of < or = 1 mm, geometric accuracy within 1 mm, and high reconstruction linearity (with a R2 value of 0.9979 and a standard error of estimation of approximately 1%) relative to independent measurement. The overall performance of the PRESAGE/OCTOPUS system was evaluated with respect to a simple known 3D dose distribution, by comparison with GAFCHROMIC EBT film and the calculated dose from a commissioned planning system. The "measured" dose distribution in a cylindrical PRESAGE dosimeter (16 cm diameter and 11 cm height) was determined by optical-CT, using a filtered backprojection reconstruction algorithm. A three-way Gamma map comparison (4% dose difference and 4 mm distance to agreement), between the PRESAGE, EBT and calculated dose distributions, showed full agreement in measurable region of PRESAGE dosimeter (approximately 90% of radius). The EBT and PRESAGE distributions agreed more closely with each other than with the calculated plan, consistent with penumbral blurring in the planning data which was acquired with an ion chamber. In summary, our results support the conclusion that the PRESAGE optical-CT combination represents a significant step forward in 3D dosimetry, and provides a robust, clinically effective and viable high-resolution relative 3D dosimetry system for radiation therapy.

Algorithms↗

Superresolution imaging from limited-aperture optical diffracted field data.

The use of an optical waveguide to attain a numerical aperture of unity in computational coherent optical imaging applications is described. It is shown that for the case of a one-dimensional (slitlike) object radiating into an optical waveguide consisting of two plane-parallel mirrors the complex field amplitude across any cross section of the waveguide contains sufficient information to reconstruct the object's transmittance function with a numerical aperture of unity. We include the derivation of an inversion algorithm for performing the object reconstruction as well as computer simulations of the procedure.

Journal Article↗

Comparison of reconstruction algorithms for optical diffraction tomography.

A recently developed inverse scattering algorithm [A. J. Devaney and M. Dennison, Inverse Probl., 19, 855 (2003) and M. Dennison and A. J. Devaney, Inverse Probl., 20, 1307 (2004)] is described and applied in a computer simulation study of optical diffraction tomography (ODT). The new algorithm is superior to standard ODT reconstruction algorithms, such as the filtered backpropagation algorithm, in applications employing a limited number of scattering experiments (the so-called limited-view case) and also in cases where multiple scattering occurs between the object being interrogated and the (known) background in which the object is embedded. The new algorithm is compared and contrasted with the filtered backpropagation algorithm in a computer simulation of ODT of weakly inhomogeneous cylindrical objects being interrogated in a limited number of scattering experiments employing incident plane waves. Our study has potential applications in biomedical imaging and tomographic microscopy.

Algorithms↗

Digital microscopy using phase-shifting digital holography with two reference waves.

A lensless, coherent optical microscope is described that uses a version of phase-shifting digital holography (PSDH) in conjunction with a field backpropagation algorithm to form coherent images of transmission-type objects. The PSDH is implemented by use of only two reference waves, in contrast with the usual implementation that requires four quadrature phase-shifting reference waves. Therefore only two digital holograms need to be recorded, and the complexity of the microscopic system is reduced. Experimental results are presented that compare images generated from conventional Gabor digital holography, two-reference-wave PSDH, and conventional white-light microscopy.

Journal Article↗