Circulatory support for long-term treatment of heart failure: experience with an intraventricular continuous flow pump.

BACKGROUND: A lifetime mechanical solution for advanced heart failure must be reliable, with a low risk of life-threatening complications. After extensive laboratory testing, we began clinical trials with an axial flow pump for long-term treatment of New York Heart Association class IV, transplant-ineligible patients. METHODS AND RESULTS: The Jarvik 2000 is a continuous flow device that is implanted in the apex of the left ventricle with offloading to the descending thoracic aorta. Skull-based percutaneous power delivery was derived from cochlear implant technology. We used this system in 4 patients with end-stage dilated cardiomyopathy. Exercise capacity, quality of life, device parameters, and native heart function were monitored serially. One patient died from right heart failure at 3 months. The other patients were discharged from hospital between 3 and 8 weeks postoperatively and are currently New York Heart Association I or II. Follow-up lasted between 9 and 20 months. There has been no device failure or hemolysis. Native heart function and quality of life were markedly improved. CONCLUSIONS: The Jarvik 2000 is a true assist (rather than replacement) device that functions synergistically with the native left ventricle and provides excellent quality of life. Adverse events are infrequent. This blood pump may provide a mechanical solution for end-stage heart failure in the community.

Adrenergic beta-Antagonists↗

End-organ function during chronic nonpulsatile circulation.

BACKGROUND: Evolving blood pump technology has produced user-friendly continuous flow left ventricular assist devices, but uncertainty exists about the safety of chronic nonpulsatile circulation. We established consistently nonpulsatile blood flow in a sheep model using the Terumo magnetically suspended centrifugal pump. We then compared end-organ function between pulseless and control animals. METHODS: Fifteen healthy sheep (65 to 85 kg) were allocated to either left ventricular assist device (n = 9) or control (n = 6) groups. We implanted the device through a left thoracotomy and determined the flow rate at which pulse pressure was absent. The flow rate was then adjusted to exceed that rate (4.2 +/- 1.5 L/min), and all variables of pump function were continuously monitored by computer. Blood tests were taken serially for hepatic and renal function and plasma renin levels. The sheep were sacrificed electively at 30 (n = 3), 90 (n = 4), 180 (n = 1), and 340 (n = 1) days. Detailed histologic examination was made of the brain, liver, kidney, myocardium, and major arteries. RESULTS: All animals remained in good condition until sacrifice. All measures of end-organ function remained within normal limits for both groups. There were no histologic differences between the organs of pulsatile and nonpulsatile animals. Although there was no significant difference in mean blood pressure, plasma renin levels were substantially elevated in pulseless animals (1.4 +/- 0.3 pg/mL versus 2.9 +/- 0.3 pg/mL; p < 0.05). We also identified thinning of the medial layer of the ascending aorta in nonpulsatile sheep (1.8 +/- 0.4 mm in left ventricular assist device animals versus 2.6 +/- 0.6 mm in control sheep; p < 0.05). CONCLUSIONS: Chronic nonpulsatile circulation was well tolerated, and we found neither functional nor histologic changes in major end organs. The renin-angiotensin system was upregulated, but this did not provide a significant rise in blood pressure. The changes in the aortic wall merit further investigation. As a result of these findings, we consider that nonpulsatile devices can be used safely for long-term circulatory support.

Animals↗

The Jarvik 2000 Heart. Clinical validation of the intraventricular position.

OBJECTIVE: Heart failure is now a public health epidemic. Donor hearts are severely restricted in availability. Permanent mechanical circulatory support or bridge to myocardial recovery are emerging alternatives. After extensive laboratory experience we sought to evaluate the intraventricular Jarvik 2000 Heart in patients with endstage heart failure. METHODS: The Jarvik 2000 Heart is a novel thumb-sized left ventricular assist device (LVAD) which is fitted within the apex of the native left ventricle. A vascular graft off loads this to the descending thoracic aorta. The pump rotor spins at between 8000 and 12,000 rpm providing 5-6 litres blood flow per minute. We have used the device with skull-mounted power delivery for seven permanent implants and trans-abdominal drive line for ten bridge-to-transplant patients. RESULTS: All patients survived the operation. Three died from non-device related complications. Survivors had early resolution of heart failure with return to NYHA I/II. All had pulsatile circulation. The device was user-friendly and imperceptible to the patient. Both the pump and native left ventricle contributed to the cardiac output during exercise. Seven patients have been transplanted successfully. All explanted devices were free from thrombus formation. Two permanent implant patients left hospital as early as 3 weeks postoperatively. CONCLUSIONS: The Jarvik 2000 is an effective user-friendly LVAD which allows early discharge from hospital. The intraventricular position has distinct advantages especially through absence of an inflow cannula. Synergy develops between the LVAD and native left ventricle. Early experience suggests that this may be a realistic LVAD to treat heart failure routinely in the outpatient setting.

Adult↗