Search PubMed⌕ Search

Biomedical subjects

Pavel Jandera

Publications and source records attributed to Pavel Jandera.

33 records · Page 2Linked to original sources

Silver-ion reversed-phase comprehensive two-dimensional liquid chromatography combined with mass spectrometric detection in lipidic food analysis.

The triacylglycerol (TAG) profiles present in real world lipidic samples are usually quite complex and, as such, monodimensional high-performance liquid chromatographic (HPLC) techniques are inadequate when challenged with such matrices. In this respect, the complementary use of silver-ion (Ag) and non-aqueous (NA) reversed-phase (RP) HPLC can be exploited if thorough TAG separations are required. The present investigation reports the employment of a newly developed comprehensive LC (LC x LC) system, based on the different separation mechanisms of the aforementioned techniques, and applied to a rice oil sample. The approach was successful in the separation of a high number of solutes, otherwise unachievable through monodimensional LC. Furthermore, the use of atmospheric pressure chemical ionization mass spectrometry (APCI-MS), as detection system, provided a third analytical dimension boosting the identification power of the comprehensive chromatographic method.

Chromatography, High Pressure Liquid↗

Comparative characteristics of HPLC columns based on quantitative structure-retention relationships (QSRR) and hydrophobic-subtraction model.

The study was aimed at quantitative comparison of retention properties of modern stationary phases for reversed-phase HPLC. Three approaches, the calculated logarithm of octanol/water partition coefficient (clogP)-based model, the molecular modeling descriptors-based model and the hydrophobic-subtraction model, were compared and discussed. Gradient retention time, tR, of a series of test analytes was a dependent variable in the quantitative structure-retention relationship (QSRR) equations describing retention in terms of analytes' structure descriptors. The QSRRs derived were used to characterize in quantitative manner the specific retention properties of nine representative reversed-phase HPLC. Either the theoretically calculated logarithm of octanol/water partition coefficient, or the structural descriptors from molecular modeling were employed to quantitatively characterize the structure of the analytes. The three molecular modeling-derived structural descriptors considered were: the total dipole moment, the electron excess charge of the most negatively charged atom and the water-accessible molecular surface area. In addition to the above standard QSRR approaches, a recently developed parameterization of reversed-phase column selectivity based on the hydrophobic-subtraction model of Snyder et al. [L.R. Snyder, J.W. Dolan, J.W. Carr, The hydrophobic-subtraction model of reversed-phase column selectivity, J. Chromatogr. A 1060 (2004) 77] was considered. According to the hydrophobic-subtraction model, reversed-phase columns are characterized by five selectivity parameters derived from the linear solvation energy relationships (LSER) theory. Values of these parameters are available for more than 300 different columns. It has been demonstrated that the clogP-based model, the molecular modeling descriptors-based model and the hydrophobic-subtraction model provide generally similar classification of the HPLC columns studied. Some differences in column classification by the three approaches considered are discussed in terms of specific properties of individual stationary phases. All the approaches allow a quantitative, although multidimensional, characteristic of HPLC columns, however, the nonempirical QSRR-based approach is simpler and require less labor.

Chromatography, High Pressure Liquid↗

RP-HPLC analysis of phenolic compounds and flavonoids in beverages and plant extracts using a CoulArray detector.

Methods were developed for the analysis of natural antioxidants including phenolic compounds and flavonoids in beverages and plant extracts using gradient HPLC with multi-channel electrochemical coulometric detection. Suitability of various reversed-phase columns for this purpose was compared; pH and mobile phase gradients were optimized with respect to the separation selectivity and sensitivity of detection. Because of different target compounds in various sample types, the overlapping resolution maps and the normalized resolution product approaches described earlier were used to select optimum columns and gradients to suit the analysis of the individual sample types. The methods were applied to the analysis of phenolic compounds and flavonoids in beer, wine, tea, and yacon extracts. 32 phenolic compounds were identified and determined, including derivatives of benzoic and cinnamic acids, flavones, and a few related glycosides. Eight-channel CoulArray detection offers high selectivity and sensitivity with limits of detection in the low microg L(-1) range, at least an order of magnitude lower than single-channel coulometric detection using the Coulochem detector. No special sample pretreatment is necessary and, because of the compatibility of the CoulArray detector with gradient elution, phenolic antioxidants of different polarities can be determined in a single run. In addition to the retention times, the ratios of the areas of the pre-dominant and post-dominant peaks to the area of the dominant peak can be used for improved identification of natural antioxidants.

Beverages↗

Quantitation of triacylglycerols in plant oils using HPLC with APCI-MS, evaporative light-scattering, and UV detection.

The main constituents of plant oils are complex mixtures of TGs differing in acyl chain lengths, number and positions of double bonds, and regioisomerism. A non-aqueous reversed-phase HPLC method with acetonitrile-2-propanol gradient and 30 + 15 cm NovaPak C18 columns makes possible an unambiguous identification of the highest number of TGs ever reported for these oils, based on positive-ion APCI mass spectra. A new approach to TG quantitation is based on the use of response factors with three typical detection techniques for that purpose (APCI-MS, evaporative light-scattering detection, and UV at 205 nm). Response factors of 23 single-acid TGs (saturated TGs from C7 to C22, 7 unsaturated TGs), 4 mixed-acid TGs, diolein and monoolein are calculated from their calibration curves and related to OOO. Due to differences between saturated and unsaturated acyl chains, the use of response factors significantly improves the quantitation of TGs. 133 TGs containing 22 fatty acids with 8-25 carbon atoms and 0-3 double bonds are identified and quantified in 9 plant oils (walnut, hazelnut, cashew nut, almond, poppy seed, yellow melon, mango, fig, date) using HPLC/APCI-MS with a response factor approach. Average parameters and relative fatty acid concentrations are calculated with both HPLC/APCI-MS and GC/ FID.

Chromatography, Gas↗

Naphthalene sulphonic acids--new test compounds for characterization of the columns for reversed-phase chromatography.

Non-substituted naphthalene sulphonic acids are strong acids, which are completely ionised in aqueous and aqueous-organic solutions. Because of repulsive electrostatic interactions, they are more or less excluded from the pores of the column packing materials commonly used in reversed-phase chromatography. The ionic exclusion can be suppressed by increasing the ionic strength of the mobile phase. In aqueous sodium sulphate solutions, very good selectivity was observed for isomeric naphthalene di- and tri-sulphonic acids, allowing reversed-phase separations of these strongly ionic compounds without addition of ion-pairing reagents to the mobile phase. The retention of the isomeric acids increases proportionally to the dipole moment, which can be explained by its effect on increasing exposure of the naphthalene ring to hydrophobic interactions with the non-polar stationary phases. Chromatographic behaviour of isomeric naphthalene di- and trisulphonic acids was investigated on 25 different columns for reversed-phase chromatography. The elution order of the isomers is the same on all the columns, but very strong stationary phase effects were observed on the retention and on the band asymmetry, depending on polar interactions with residual silanol groups and other polar adsorption centres in the stationary phases. These effects are independent of the organic solvents, as the tests are performed in purely aqueous mobile phases and allow classification of the columns into several groups.

Chromatography, High Pressure Liquid↗

Stationary-phase effects in gradient high-performance liquid chromatography.

The type of the stationary phase for reversed-phase liquid chromatography significantly affects the sample polarity range that can be covered using gradients of organic solvents in water. The polarity range available for gradient separations of samples containing compounds differing in the lipophilic parts of the molecules can be characterized by "gradient lipophilic capacity", Pl, based on the retention of standard compounds with a repeat lipophilic structural unit, such as a methylene group. The gradient lipophilic capacity is also suitable to characterize the separation possibilities of the columns in non-aqueous reversed-phase gradient elution of strongly non-polar compounds, such as triacylglycerols. In the same way, the suitability of various columns for reversed-phase gradient separations of oligomers can be characterized by "gradient oligomer capacity", as demonstrated in the example of oligo(ethylene glycols). To enable a comparison of the properties of stationary phases independent of column efficiency and dimensions, the gradient lipophilic capacity or the gradient oligomer capacity should be normalized for a "standard" column plate number, gradient range and volume (in column hold-up volume units). The gradient lipophilic capacity or the gradient oligomer capacity and the number of compounds that can be resolved during a gradient run decrease as the initial concentration of the strong solvent in the mobile phase increases and (or) the gradient time decreases. These quantities can be used to select a suitable column and to adjust the optimum gradient profile (the initial composition of the mobile phase and the gradient steepness) with respect to the time of analysis and the number of oligomers or other compounds with regular repeat structural groups that can be resolved during the gradient run.

Chromatography, High Pressure Liquid↗

Comparison of monolithic silica and polymethacrylate capillary columns for LC.

Organic polymer monolithic capillary columns were prepared in fused-silica capillaries by radical co-polymerization of ethylene dimethacrylate and butyl methacrylate monomers with azobisisobutyronitrile as initiator of the polymerization reaction in the presence of various amounts of porogenic solvent mixtures and different concentration ratios of monomers and 1-propanol, 1,4-butanediol, and water. The chromatographic properties of the organic polymer monolithic columns were compared with those of commercial silica-based particulate and monolithic capillary and analytical HPLC columns. The tests included the determination of H-u curves, column permeabilities, pore distribution by inversed-SEC measurements, methylene and polar selectivities, and polar interactions with naphthalenesulphonic acid test samples. Organic polymer monolithic capillary columns show similar retention behaviour to chemically bonded alkyl silica columns for compounds with different polarities characterized by interaction indices, Ix, but have lower methylene selectivities and do not show polar interactions with sulphonic acids. The commercial capillary and analytical silica gel-based monolithic columns showed similar selectivities and provided symmetrical peaks, indicating no significant surface heterogeneities. To allow accurate characterization of the properties of capillary monolithic columns, the experimental data should be corrected for extra-column contributions. With 0.3 mm ID capillary columns, corrections for extra-column volume contributions are sufficient, but to obtain true information on the efficiency of 0.1 mm ID capillary columns, the experimental bandwidths should be corrected for extra-column contributions to peak broadening.

1-Propanol↗

Controlling the retention in capillary LC with solvents, temperature, and electric fields.

Once a suitable stationary phase and column dimensions have been selected, the retention in liquid chromatography (LC) is traditionally adjusted by controlling the mobile phase composition. Solvent gradients enable achievement of good separation selectivity while decreasing the separation time as compared to isocratic elution. Capillary columns allow use of other programming parameters, i.e. temperature and applied electric fields, in addition to solvent gradient elution. This paper presents a review of programmed separation techniques in miniaturized LC, including retention modeling and method transfer from the conventional to micro- and capillary scales. The impact of miniaturized instrumentation on retention and the limitations of capillary LC are discussed. Special attention is focused on the gradient dwell volume effects, which are more important in micro-LC techniques than in conventional analytical LC and may cause significant increase in the time of analysis, unless special instrumentation and (or) pre-column flow-splitting is used. The influence of temperature upon retention is also discussed, and applications where the temperature has been actively used for retention control in capillary LC are included together with the instrumentation utilized. Finally the possibilities of additional selectivity control by applying an electric field over a packed capillary LC column are discussed.

Journal Article↗

Optimisation of gradient HPLC analysis of phenolic compounds and flavonoids in beer using a coularray detector.

A method was developed for simultaneous analysis of natural antioxidants in beer using multichannel electrochemical detection with a CoulArray detector, which enables selective and sensitive antioxidant detection in gradient HPLC and facilitates the identification of analytes based on the ratios of signals recorded at different potentials applied to the detection cells arranged in series. The separation conditions were optimised for 27 phenolic compounds including derivatives of benzoic and cinnamic acids, flavones, and a few related glycosides identified in beer samples. Separation selectivities of 11 columns with different stationary phase chemistries were compared, and the pH and gradient programs were optimised for the individual columns to provide best resolution and high number of resolved peaks, using the window-diagram approach. The effects of pH on the sensitivity of electrochemical coulometric detection were considered in the optimisation approach. The optimised conditions were applied to the analysis of real beer samples.

Antioxidants↗

Adsorption isotherms and retention behavior of 1,1'-bis(2-naphthol) on CHIRIS AD1 and CHIRIS AD2 columns.

The separation of the atropoisomers of 1,1'-bis(2-naphthol) was studied on CHIRIS AD1 and CHIRIS AD2, two Pirkle-type chiral stationary phases. Satisfactory selectivity was found only on CHIRIS AD2. The ternary mobile phases comprised hexane, dichloromethane and methanol. The effects of their composition and of the temperature on the retention under analytical conditions and on the single-component and competitive isotherms were investigated. The retention of the R- and S-isomers on CHIRIS AD1 and CHIRIS AD2 is controlled by the enthalpic contribution to adsorption, but the effect of the mobile phase on the retention should be attributed mainly to the entropic contribution. The adsorption of the less retained R-isomer is controlled by the achiral interactions, which are the same as for the S-isomer. The single-component and competitive isotherms of the R- and S-isomers are adequately described by the sum of a Langmuir term for the achiral contribution to adsorption and a linear-term characterising the selective or chiral adsorption of the S-isomer in the concentration range experimentally available, i.e. within the solubility limit of 1,1'-bis(2-naphthol).

Adsorption↗

Characterization of triacylglycerol and diacylglycerol composition of plant oils using high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

Triacylglycerols (TGs) and diacylglycerols (DGs) in 16 plant oil samples (hazelnut, pistachio, poppy-seed, almond, palm, Brazil-nut, rapeseed, macadamia, soyabean, sunflower, linseed, Dracocephalum moldavica, evening primrose, corn, amaranth, Silybum arianum) were analyzed by HPLC-MS with atmospheric pressure chemical ionization (APCI) and UV detection at 205 nm on two Nova-Pak C18 chromatographic columns connected in series. A single chromatographic column and non-aqueous ethanol-acetonitrile gradient system was used as a compromise between the analysis time and the resolution for the characterization of TG composition of five plant oils. APCI mass spectra were applied for the identification of all TGs and other acylglycerols. The isobaric positional isomers can be distinguished on the basis of different relative abundances of the fragment ions formed by preferred losses of the fatty acid from sn-1(3) positions compared to the sn-2 position. Excellent chromatographic resolution and broad retention window together with APCI mass spectra enabled positive identification of TGs containing fatty acids with odd numbers of carbon atoms such as margaric (C17:0) and heptadecanoic (C17:1) acids. The general fragmentation patterns of TGs in both APCI and electrospray ionization mass spectra were proposed on the basis of MSn spectra measured with an ion trap analyzer. The relative concentrations of particular TGs in the analyzed plant oils were estimated on the basis of relative peak areas measured with UV detection at 205 nm.

Atmospheric Pressure↗

Gradient elution in normal-phase high-performance liquid chromatographic systems.

Gradient elution is widely used for separation of complex samples in reversed-phase HPLC systems, but is less frequently applied in normal-phase HPLC, where it has a notoriously bad reputation for poor reproducibility and unpredictable retention. This behaviour is caused by preferential adsorption of polar solvents used in mixed mobile phases, which may cause significant deviations of the actual gradient profile from the pre-set program. Another important source of irreproducible retention behaviour is gradual deactivation of the adsorbent by adsorption of even traces of water during normal-phase gradient elution. To avoid this phenomenon, carefully dried solvents should be used. Finally, column temperature should be carefully controlled during normal-phase gradient elution if reproducible results are to be obtained. Working with dry solvents at a controlled constant temperature and using a sophisticated gradient-elution chromatograph, reproducibility of the retention data in normal-phase gradient elution better than 2% may be achieved even over several months of column use. The retention data in gradient elution can be calculated accurately if appropriate corrections are adopted for the gradient dwell volume and for the preferential adsorption of the polar solvents using experimental adsorption isotherms. The average error of prediction for the corrected calculated gradient retention data was lower than 2% for a silica gel column and lower than 3% for a bonded nitrile column, which may be suitable for the optimization of separation. Further, a simple approach is suggested for rapid estimation of changes in the retention induced by a change in the gradient profile in normal-phase HPLC. For such a rough estimation, it is not necessary to know the parameters of the dependence of the solute retention factors on the composition of the mobile phase.

Chromatography, High Pressure Liquid↗

Impact of adsorption isotherm parameters on the performance of enantioseparation using simulated moving bed chromatography.

Often there are several chromatographic systems, i.e., combinations of mobile and stationary phases, available to solve a certain separation problem. Essential differences of these chromatographic systems are the separation factors and the efficiencies. For preparative applications in addition also the column saturation capacities and solubility limits are of importance. The impact of all these parameters appears to be rather well understood for conventional overloaded elution chromatography using a single column. In the last years the continuous simulated moving bed (SMB) process was increasingly used as a powerful alternative to batch elution since increased productivities and reduced solvent consumptions could be realised. However, the selection of suitable chromatographic systems is more sophisticated for this process. In this paper five different chromatographic systems capable of separating the enantiomers of mandelic acid are compared based on the achievable productivities using SMB chromatography. For these five systems the adsorption isotherms have been determined experimentally. Subsequently, an analysis of the SMB process was performed numerically using a well-established model.

Adsorption↗