Search PubMed⌕ Search

Biomedical subjects

Paul R Stauffer

Publications and source records attributed to Paul R Stauffer.

5 recordsLinked to original sources

Automatic temperature controller for multielement array hyperthermia systems.

This paper concerns the optimization and performance analysis of an automatic control algorithm for managing power output of large multielement array hyperthermia applicators. Simulation and corresponding measurement of controller performance in a solid tissue equivalent phantom model is utilized for analysis of controller response to dynamically varying thermal load conditions that simulate clinical treatments. The analysis leads to an optimum controller which demonstrates the ability to achieve a uniform and stable temperature profile over a large surface area regardless of surrounding thermal load. This paper presents several advancements to the performance of a previously published control routine, including: 1) simplified simulation techniques for thorough characterization of controller performance; 2) an optimization procedure leading to an improved hybrid control algorithm for maintaining optimal performance during periods of both "rising" and "steady-state" temperature; 3) performance analysis of a control algorithm tailored for large area hyperthermia treatments with a mulitelement array applicator. The optimized hybrid controller is applied to the conformal microwave array (CMA) hyperthermia system previously developed for heating large area surface disease such as diffuse chestwall recurrence of breast carcinoma, and shown to produce stable, uniform temperatures under the multielement array applicator for all thermal load conditions.

Body Temperature Regulation↗

Evolving technology for thermal therapy of cancer.

This paper is intended as a succinct review of technology used for clinical hyperthermia therapy for cancer, as culled from a presentation at the special workshop on Thermal Medicine, Heat Shock Proteins, and Cancer at the Society for Thermal Medicine conference in Spring 2005. Following a brief overview of thermal therapy treatment options and available mechanisms for heating tissue, the paper focuses on the evolution of equipment from basic single element heating devices of the early 1980s to adjustable multi-element heating devices currently in use or in final stages of development. Representative devices from the past, present and near future are cited for further investigation by the interested reader. The paper concludes with a summary of general trends in the evolution of clinical hyperthermia techniques and a statement of current challenges remaining for the field.

Hot Temperature↗

Characteristics of microstrip muscle-loaded single-arm Archimedean spiral antennas as investigated by FDTD numerical computations.

The radiation characteristics and mode of operation of single-arm, groundplane backed, Archimedean spiral antennas are investigated by means of conformal finite difference time domain numerical analysis. It is shown that this antenna type may be categorized as a well-matched, broadband, circularly polarized traveling wave structure that can be fed directly by nonbalanced coaxial networks. The study further concentrates on relevant design and description features parameterized in terms of measures like radiation efficiency, sensing depth, directivity, and axial ratio of complementary polarizations. We document that an antenna of only 30-mm transverse size produces circularly polarized waves in a two-octave frequency span (2-8 GHz) with acceptable radiation efficiency (76%-94%) when loaded by muscle-like tissue.

Animals↗

Radiation dosimetry of a conformal heat-brachytherapy applicator.

The purpose of this paper is to report the radiation dosimetric characteristics of a new combination applicator for delivering heat and radiation simultaneously to large area superficial disease <1.5 cm deep. The applicator combines an array of brachytherapy catheters (for radiation delivery) with a conformal printed circuit board microwave antenna array (for heat generation), and a body-conforming 5-10 mm thick temperature-controlled water bolus. The rationale for applying both modalities simultaneously includes the potential for significantly higher response rate due to enhanced synergism of modalities, and lower peak toxicity due to temporal extension of heat and radiation induced toxicities. Treatment plans and radiation dosimetry are calculated with IPSA (an optimization tool developed at UCSF) for 15 x 15 cm(2) and 35 x 24 cm(2) applicators, lesion thicknesses of 5 to 15 mm, flat and curved surfaces, and catheter separation of 5 and 10 mm. The effect on skin dose of bolus thickness and presence of thin copper antenna structures between radiation source and tissue are also evaluated. Results demonstrate the ability of the applicator to provide conformal radiation dose coverage for up to 15 mm deep target volumes under the applicator. For clinically acceptable plans, tumor coverage is > 98%, homogeneity index > 0.95 and the percentage of normal tissue irradiated is < 20%. The dose gradient at the skin surface varies from 3 to 5 cGy/mm depending on bolus thickness and lesion depth. Attenuation of the photon beam by the printed circuit antenna array is of the order 0.25% and secondary electron emissions are absorbed completely within 5 mm of water bolus and plastic layers. Both phenomena can then be neglected in dose calculations allowing commercial software to be used for treatment planning. This novel applicator should prove useful for the treatment of diffuse chestwall disease located over contoured anatomy that may be difficult to treat with single field external beam therapy. By delivering heat and radiation simultaneously, increased synergism is expected with a TER in the range of 2-5. Lowering radiation dose by an equivalent factor may produce lower radiation toxicity with similar efficacy, while preserving the option of subsequent retreatment(s) with thermoradiotherapy in order to further extend patient survival.

Algorithms↗

Nonparametric 1-D temperature restoration in lossy media using Tikhonov regularization on sparse radiometry data.

Microwave thermometry has the potential to characterize thermal gradients in lossy materials down to a few centimeters depth. The problem of retrieving temperature profiles from sets of brightness temperatures is studied using Galerkin expansion of one-dimensional (1-D) temperature profiles combined with Tikhonov regularization and predefined boundary conditions. From a priori knowledge of the temperature field shape, smooth Chebyshev polynomials are used as basis functions in the series expansion. The proposed estimator does not require iterative calculations that are normally performed using conventional numerical methods for signal parameter estimation and is, thus, very fast. Noise effects versus bandwidth limitations (smoothness of solutions) are studied in terms of four performance indexes defined in the text. In general, statistical spread of the temperature estimator increases with increasing number of Chebyshev polynomials. Systematic deviation from true values (bias) decreases as the number of Chebyshev polynomials increases. Results show that smooth temperature profiles can be reproduced using 6-7 Chebyshev polynomials. With additional constraints such as boundary conditions and maxima localization, a three-frequency-band radiometric scan is sufficient to produce acceptable results in regions with low thermal gradients. As the spatial variability of the 1-D temperature profile increases, more radiometric bands (5-6) are required to provide nonbiased estimates.

Algorithms↗