Structurally distinct membrane nanotubes between human macrophages support long-distance vesicular traffic or surfing of bacteria.

We report that two classes of membrane nanotubes between human monocyte-derived macrophages can be distinguished by their cytoskeletal structure and their functional properties. Thin membrane nanotubes contained only F-actin, whereas thicker nanotubes, i.e., those > approximately 0.7 microm in diameter, contained both F-actin and microtubules. Bacteria could be trapped and surf along thin, but not thick, membrane nanotubes toward connected macrophage cell bodies. Once at the cell body, bacteria could then be phagocytosed. The movement of bacteria is aided by a constitutive flow of the nanotube surface because streptavidin-coated beads were similarly able to traffic along nanotubes between surface-biotinylated macrophages. Mitochondria and intracellular vesicles, including late endosomes and lysosomes, could be detected within thick, but not thin, membrane nanotubes. Analysis from kymographs demonstrated that vesicles moved in a stepwise, bidirectional manner at approximately 1 microm/s, consistent with their traffic being mediated by the microtubules found only in thick nanotubes. Vesicular traffic in thick nanotubes and surfing of beads along thin nanotubes were both stopped upon the addition of azide, demonstrating that both processes require ATP. However, microtubule destabilizing agents colchicine or nocodazole abrogated vesicular transport but not the flow of the nanotube surface, confirming that distinct cytoskeletal structures of nanotubes give rise to different functional properties. Thus, membrane nanotubes between macrophages are more complex than unvarying ubiquitous membrane tethers and facilitate several means for distal interactions between immune cells.

Actins↗

Microclusters of inhibitory killer immunoglobulin-like receptor signaling at natural killer cell immunological synapses.

We report the supramolecular organization of killer Ig-like receptor (KIR) phosphorylation using a technique applicable to imaging phosphorylation of any green fluorescent protein-tagged receptor at an intercellular contact or immune synapse. Specifically, we use fluorescence lifetime imaging (FLIM) to report Förster resonance energy transfer (FRET) between GFP-tagged KIR2DL1 and a Cy3-tagged generic anti-phosphotyrosine monoclonal antibody. Visualization of KIR phosphorylation in natural killer (NK) cells contacting target cells expressing cognate major histocompatibility complex class I proteins revealed that inhibitory signaling is spatially restricted to the immune synapse. This explains how NK cells respond appropriately when simultaneously surveying susceptible and resistant target cells. More surprising, phosphorylated KIR was confined to microclusters within the aggregate of KIR, contrary to an expected homogeneous distribution of KIR signaling across the immune synapse. Also, yellow fluorescent protein-tagged Lck, a kinase important for KIR phosphorylation, accumulated in a multifocal distribution at inhibitory synapses. Spatial confinement of receptor phosphorylation within the immune synapse may be critical to how activating and inhibitory signals are integrated in NK cells.

Cell Line↗

Fluorescence lifetime imaging provides enhanced contrast when imaging the phase-sensitive dye di-4-ANEPPDHQ in model membranes and live cells.

We apply fluorescence lifetime imaging to the membrane phase-sensing dye di-4-ANEPPDHQ in model membranes and live cells. We show that the 1700 ps lifetime shift between liquid-disordered and liquid-ordered phases offers greater contrast than the 60 nm spectral shift previously reported. Detection of cholesterol-rich membrane microdomains is confirmed by observation of the temperature dependence of membrane order and by cholesterol depletion using methyl-beta-cyclodextrin.

Cell Line↗

Quantitative 3D mapping of fluidic temperatures within microchannel networks using fluorescence lifetime imaging.

We describe a novel method for quantitatively mapping fluidic temperature with high spatial resolution within microchannels using fluorescence lifetime imaging in an optically sectioning microscope. Unlike intensity-based measurements, this approach is independent of experimental parameters, such as dye concentration and excitation/detection efficiency, thereby facilitating quantitative temperature mapping. Micrometer spatial resolution of 3D temperature distributions is readily achieved with an optical sectioning approach based on two-photon excitation. We demonstrate this technique for mapping of temperature variations across a microfluidic chip under different heating profiles and for mapping of the 3D temperature distribution across a single microchannel under applied flow conditions. This technique allows optimization of the chip design for miniaturized processes, such as on-chip PCR, for which precise temperature control is important.

Energy Transfer↗

Time-resolved fluorescence microscopy.

In fluorescence microscopy, the fluorescence emission can be characterised not only by intensity and position, but also by lifetime, polarization and wavelength. Fluorescence lifetime imaging (FLIM) can report on photophysical events that are difficult or impossible to observe by fluorescence intensity imaging, and time-resolved fluorescence anisotropy imaging (TR-FAIM) can measure the rotational mobility of a fluorophore in its environment. We compare different FLIM methods: a chief advantage of wide-field time-gating and phase modulation methods is the speed of acquisition whereas for time-correlated single photon counting (TCSPC) based confocal scanning it is accuracy in the fluorescence decay. FLIM has been used to image interactions between proteins such as receptor oligomerisation and to reveal protein phosphorylation by detecting fluorescence resonance energy transfer (FRET). In addition, FLIM can also probe the local environment of fluorophores, reporting, for example, on the local pH, refractive index, ion or oxygen concentration without the need for ratiometric measurements.

Fluorescence Polarization↗

Fluorescence imaging of two-photon linear dichroism: cholesterol depletion disrupts molecular orientation in cell membranes.

The plasma membrane of cells is an ordered environment, giving rise to anisotropic orientation and restricted motion of molecules and proteins residing in the membrane. At the same time as being an organized matrix of defined structure, the cell membrane is heterogeneous and dynamic. Here we present a method where we use fluorescence imaging of linear dichroism to measure the orientation of molecules relative to the cell membrane. By detecting linear dichroism as well as fluorescence anisotropy, the orientation parameters are separated from dynamic properties such as rotational diffusion and homo energy transfer (energy migration). The sensitivity of the technique is enhanced by using two-photon excitation for higher photo-selection compared to single photon excitation. We show here that we can accurately image lipid organization in whole cell membranes and in delicate structures such as membrane nanotubes connecting two cells. The speed of our wide-field imaging system makes it possible to image changes in orientation and anisotropy occurring on a subsecond timescale. This is demonstrated by time-lapse studies showing that cholesterol depletion rapidly disrupts the orientation of a fluorophore located within the hydrophobic region of the cell membrane but not of a surface bound probe. This is consistent with cholesterol having an important role in stabilizing and ordering the lipid tails within the plasma membrane.

Algorithms↗

Holographic optical coherence imaging of rat osteogenic sarcoma tumor spheroids.

Holographic optical coherence imaging is a full-frame variant of coherence-domain imaging. An optoelectronic semiconductor holographic film functions as a coherence filter placed before a conventional digital video camera that passes coherent (structure-bearing) light to the camera during holographic readout while preferentially rejecting scattered light. The data are acquired as a succession of en face images at increasing depth inside the sample in a fly-through acquisition. The samples of living tissue were rat osteogenic sarcoma multicellular tumor spheroids that were grown from a single osteoblast cell line in a bioreactor. Tumor spheroids are nearly spherical and have radial symmetry, presenting a simple geometry for analysis. The tumors investigated ranged in diameter from several hundred micrometers to over 1 mm. Holographic features from the tumors were observed in reflection to depths of 500-600 microm with a total tissue path length of approximately 14 mean free paths. The volumetric data from the tumor spheroids reveal heterogeneous structure, presumably caused by necrosis and microcalcifications characteristic of some human avascular tumors.

Animals↗

Time-resolved fluorescence anisotropy imaging applied to live cells.

We have developed a wide-field time-resolved imaging system to image quantitatively both the fluorescence lifetime and the rotational correlation time of a fluorophore. Using a polarization-resolved imager, we simultaneously image orthogonal polarization components of the fluorescence emission onto a time-gated intensified CCD. We demonstrate imaging of solvent viscosity variations through the rotational correlation time of fluorescein in a multiwell plate and apply this technique to probe the microviscosity in live cells.

3T3 Cells↗

Studying biological tissue with fluorescence lifetime imaging: microscopy, endoscopy, and complex decay profiles.

We have applied fluorescence lifetime imaging (FLIM) to the autofluorescence of different kinds of biological tissue in vitro, including animal tissue sections and knee joints as well as human teeth, obtaining two-dimensional maps with functional contrast. We find that fluorescence decay profiles of biological tissue are well described by the stretched exponential function (StrEF), which can represent the complex nature of tissue. The StrEF yields a continuous distribution of fluorescence lifetimes, which can be extracted with an inverse Laplace transformation, and additional information is provided by the width of the distribution. Our experimental results from FLIM microscopy in combination with the StrEF analysis indicate that this technique is ready for clinical deployment, including portability that is through the use of a compact picosecond diode laser as the excitation source. The results obtained with our FLIM endoscope successfully demonstrated the viability of this modality, though they need further optimization. We expect a custom-designed endoscope with optimized illumination and detection efficiencies to provide significantly improved performance.

Animals↗

Fluorescence lifetime imaging of unstained tissues: early results in human breast cancer.

Fluorescence lifetime imaging (FLIM) depends on the fluorescence decay differences between tissues to generate image contrast. In the present study FLIM has been applied to fixed (but unstained) breast cancer tissues to demonstrate the feasibility of this approach for histopathological assessment. As the FLIM method relies on natural autofluorescence, it may be possible to circumvent tissue processing altogether and so FLIM has the potential to be a powerful new method of in vivo tissue imaging via an endoscopic or per-operative approach in a variety of organs, as well as a research tool for in vivo animal models of disease. Unstained, alcohol-fixed tissue samples from 13 patients were stimulated by laser pulses at 415 nm. The temporal decay of the autofluorescence was imaged over a period of 2 ns after cessation of the pulse. The decay rate at each image pixel was calculated as the 'lifetime' factor tau. A tissue classification scheme was used to define regions in each image. The average lifetimes of different tissue regions were compared. A total of 167 tissue regions were measured. Within individual fields, stroma had a larger tau (slower decay) than epithelium (p < 0.001). Within individual patients (taking the mean tau of a given tissue type across all fields from each patient), there was a statistically significant difference between benign and malignancy-associated stroma (p < 0.05). Also, benign collagen had a longer tau than benign epithelium (p < 0.05). Multivariate analysis showed a significant difference between benign stroma, malignancy-associated stroma, blood vessels, and malignant epithelium (p < 0.05). Statistically significant differences between benign and malignancy-associated stroma were obtained even with small patient numbers, indicating that lifetime-based instruments can be developed for real-time diagnostic imaging with microscopic resolution.

Breast Neoplasms↗

Imaging the environment of green fluorescent protein.

An emerging theme in cell biology is that cell surface receptors need to be considered as part of supramolecular complexes of proteins and lipids facilitating specific receptor conformations and distinct distributions, e.g., at the immunological synapse. Thus, a new goal is to develop bioimaging that not only locates proteins in live cells but can also probe their environment. Such a technique is demonstrated here using fluorescence lifetime imaging of green fluorescent protein (GFP). We first show, by time-correlated single-photon counting, that the fluorescence decay of GFP depends on the local refractive index. This is in agreement with the Strickler Berg formula, relating the Einstein A and B coefficients for absorption and spontaneous emission in molecules. We then quantitatively image, by wide-field time-gated fluorescence lifetime imaging, the refractive index of the environment of GFP. This novel approach paves the way for imaging the biophysical environment of specific GFP-tagged proteins in live cells.

Fluorescence↗

Imaging immune surveillance by T cells and NK cells.

As T cells and natural killer (NK) cells survey the surface of other cells, cognate receptors and ligands are commonly organized into distinct micrometer-scale domains at the intercellular contact, creating an immune or immunological synapse (IS). We aim to address the still unanswered questions of how this organization of proteins aids immune surveillance and how these domains are biophysically constructed. Molecular mechanisms for the formation of the IS include a role for the cytoskeleton, segregation of proteins according to the size of their extracellular domains, and association of proteins with lipid rafts. Towards understanding the function of the IS, it is instructive to compare and contrast the supramolecular organization of proteins at the inhibitory and activating NK cell IS with that at the activating T cell IS. Finally, it is essential to develop new technologies for probing molecular recognition at cell surfaces. Imaging parameters other than fluorescence intensity, such as the lifetime of the fluorophore's excited state, could be used to report on protein environments.

Animals↗