Rate control: is local better?
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Paul J Wang.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The goal of the present study was to determine if there are global or regionally specific decreases in callosal area in early Alzheimer's disease (AD) and mild cognitive impairment (MCI). In addition, this study examined the corpus callosum of healthy older adults who have subjective cognitive complaints (CC) but perform within normal limits on neuropsychological tests. We used a semi-automated procedure to examine the total and regional areas of the corpus callosum in 22 patients with early AD, 28 patients with amnestic MCI, 28 healthy older adults with cognitive complaints, and 50 demographically matched healthy controls (HC). The AD, MCI, and CC groups all showed a significant reduction of the posterior region (isthmus and splenium) relative to healthy controls. The AD group also had a significantly smaller overall callosum than the controls. The demonstration of callosal atrophy in older adults with cognitive complaints suggests that callosal changes occur very early in the dementing process, and that these earliest changes may be too subtle for detection by neuropsychological assessments, including memory tests.
OBJECTIVES: We sought to examine the relationship between symptoms of depression and shock-treated ventricular arrhythmias among implantable cardioverter-defibrillator (ICD) patients. BACKGROUND: Depression predicts mortality in patients with coronary artery disease (CAD), but whether this is via an increased risk of fatal ventricular arrhythmias is unclear. METHODS: We prospectively analyzed data on symptoms of depression and risk of ventricular arrhythmia (ventricular tachycardia/ventricular fibrillation [VT/VF]) resulting in ICD discharge in the Triggers of Ventricular Arrhythmias (TOVA) study. Symptoms were assessed by the Center for Epidemiologic Studies-Depression (CES-D) scale. Scores of 16 to 26 and > or =27 represented mild and moderate/severe depression, respectively. The Cox and Anderson-Gill proportional hazards models were used to test for associations among all patients and patients with CAD. RESULTS: Among 645 patients with baseline assessments, 90 (14%) were mildly depressed and 25 (3.9%) were moderately to severely depressed. Moderate/severe depression was associated with time to first shock for VT/VF (hazard ratio [HR] 3.2, 95% confidence interval [CI] 1.1 to 9.9) and all shocks for VT/VF including recurrent episodes (HR 3.2, 95% CI 1.2 to 8.6). Among the 476 CAD patients, the association with time to first shock (HR 6.4, 95% CI 1.9 to 21.1) and all shocks (HR 8.3, 95% CI 2.9 to 23.3) remained. The risk of shock for VT/VF was associated with depression severity in the total population (p for trend = 0.02) and among patients with CAD (p < 0.01), even after controlling for multiple confounders. CONCLUSIONS: More severe symptoms of depression predict shocks for VT/VF among ICD patients. The elevated risk of VT/VF among patients with CAD and depression suggests that arrhythmia may contribute significantly to total mortality in this subgroup.
BACKGROUND: Recently, the use of robotic assisted surgery has been utilized in cardiac surgical procedures. The use of robotics may offer benefits in precision, stability and control of instruments remotely. We report early experience with a novel remote robotic catheter control system (CCS). METHODS: We used a computerized robotically controlled catheter system that enables the user to remotely manipulate the tip of a catheter precisely in three dimensions. We tested the robotic catheter control systems ability to navigate within the heart and to make precise, rapid and repeatable movements. We compared the CCS with the ability of a standard quadripolar steerable ablation catheter placed in a deflectable sheath to navigate and make precision movements. Twelve ex-vivo porcine hearts were utilized to permit accurate measurements of navigation and precision. Eight targets were selected for navigation and precision testing. Time was measured for the catheter to reach the predefined target from a specific starting point to test navigation. In addition, time was measured to contact a discrete 0.8 mm target in order to test precision. RESULTS: The use of the CCS reduced the time needed for both navigation (8.5 +/- 13.9 sec vs. 22.7 +/- 26.7 sec, p = 0.002) and significantly decreased the time for precision targeting (10.1 +/- 6.9 sec vs. 29.6 +/- 26.4 sec, p < 0.001) in the specific RA and LA sites in the ex-vivo hearts. CONCLUSIONS: The use of a computerized robotically assisted catheter control system is feasible and shows promise in rapid precision movement of the catheter. Further study is needed to elucidate the role of such a system in-vivo and in patient specific catheter ablation and mapping.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: Orthotopic heart transplantation is considered an effective treatment for patients with refractory heart failure. The long-term survival of orthotopic heart transplantation recipients has increased over the last several decades, but many long-term survivors of orthotopic heart transplantation develop graft atherosclerosis and associated left ventricular dysfunction. The risk of sudden cardiac death in long-term survivors of orthotopic heart transplantation with these complications is believed to be high. There are no data on the usefulness of implantable cardioverter-defibrillators (ICDs) in this population; therefore, we report our early experience with ICD placement in such patients. OBJECTIVES: The purpose of this study was to examine the use of ICDs in adults who are long-term survivors of heart transplantation. METHODS: We retrospectively reviewed all adult patients who underwent orthotopic heart transplantation at Stanford University Hospital (Stanford, CA, USA) from 1980 to 2004. All patients who received an ICD after transplant were included in this study. We reviewed demographic data, medical history, ejection fraction, presence of graft atherosclerosis, indication for ICD placement, and any device therapy delivered. RESULTS: Of the 925 patients who had orthotopic heart transplantation during this time period, 493 patients were alive at the beginning of the year 2000. Of these patients, 10 ( approximately 2%) had subsequent placement of an ICD. All 10 patients were male. The average age at orthotopic heart transplantation was 37.8 years. The average age at ICD placement was 50.5 years. The average time from orthotopic heart transplantation to ICD placement was 14.6 years. The average ejection fraction at the time of implant was 46.5%. Five of the 10 patients had a low ejection fraction (within this subgroup, the average ejection fraction was 31%, range 15%-45%) and graft atherosclerosis. ICDs were placed because of symptomatic episodes of ventricular tachycardia (3 patients), low ejection fraction and severe graft atherosclerosis without symptoms (3 patients), and after thorough evaluation for otherwise unexplained syncope (4 patients). The average follow-up after device implantation was 13 months. Complications related to ICD placement were an infected ICD system requiring explant in one patient and a lead fracture in another patient. Three patients had subsequent appropriate shocks for ventricular arrhythmias, and one patient underwent a second orthotopic heart transplantation. One patient died of malignancy. CONCLUSION: Use of the ICD in long-term survivors of orthotopic heart transplantation should be considered in appropriately selected patients. Further data are needed regarding ICD use in this population.
Explore the source record for details and available documents.
BACKGROUND: Facilitation is an important physiologic property of the atrioventricular (AV) node. Previous studies demonstrated abnormal AV conduction in connexin (Cx)40-deficient mice. OBJECTIVES: We hypothesize that Cx40-deficient mice display altered patterns of AV nodal facilitation compared with wild-type mice. METHODS: Sixteen 36-week-old mice (eight Cx40(-/-) mice and eight Cx40(+/+) controls) underwent in vivo closed chest electrophysiologic study. A 2Fr octapolar catheter was advanced into the right ventricle to record a His-bundle electrogram. A special facilitation stimulation protocol was performed in each mouse to evaluate facilitation. Following atrial drive pacing (S1S1) at 150 ms, a facilitating beat S2 was delivered prior to the test beat S3. S3H3 was measured for varying S1S2 values at fixed H2S3 intervals. RESULTS: Progressive shortening of S1S2 (from 150 ms to 130, 110, and 90 ms) resulted in gradual prolongation of S2H2. The prolongation was more pronounced in Cx40(-/-) mice for each S1S2 compared with wild-type mice (P <.001). In each wild-type mouse, for a given H2S3 interval, this gradual increase in S2H2 produced progressive shortening of S3H3, so-called AV nodal facilitation phenomenon. However, in each Cx40(-/-) mouse, facilitation was seen only at S1S2 of 130 ms (P <.001 vs S1S2 of 150 ms). Evidence of reverse facilitation was documented at S1S2 of 110 and 90 ms. CONCLUSION: Facilitation is observed in wild-type mice. With similar S1S2 intervals in Cx40-deficient mice, facilitation is seen only at longer S1S2 intervals, whereas reverse facilitation is seen at shorter S1S2 intervals, suggesting that Cx40 is involved in the generation of AV nodal facilitation.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
INTRODUCTION: Deaths secondary to low-energy impacts to the precordium in young individuals (commotio cordis) have been reported with increasing frequency. In a swine model, baseball impacts induce ventricular fibrillation when directed at the center of the left ventricle during the vulnerable portion of repolarization just prior to the T-wave peak. It has been hypothesized that activation of stretch-sensitive channels could be crucial for this electrophysiological phenomenon. In this study, a nonselective stretch-activated cation channel was pharmacologically blocked prior to chest blows to determine whether this channel represents a possible pathway by which commotio cordis events occur. METHODS: In a randomized and blinded experiment, 12 swine (mean 17.1 +/- 2.5 kg) received either 2-g streptomycin intramuscularly (mean serum concentration 115 +/- 18 muM) or sterile water prior to chest impact. Each animal received six precordial impacts with a baseball propelled at 40 mph. RESULTS: There was no significant difference in the frequency of induced VF in the animals administered streptomycin (10 of 19 impacts: 53%) compared to those control animals receiving only sterile water (10 of 31: 32%) (P = 0.15). However, the magnitude of ST segment elevation was less in the streptomycin-treated animals (19 +/- 19 mV) versus controls (61 +/- 46 mV) (P = 0.015). CONCLUSION: Streptomycin did not alter the frequency of ventricular fibrillation in our commotio cordis model, indicating that the stretch-activated channel is not implicated in the genesis of chest blow-induced cardiac arrest. However, streptomycin did reduce ST elevation following impact suggesting that the stretch-activated channel may play a role in ST segment elevation following chest wall blows.
We tested the use of correlation-waveform analysis (CWA) of atrial and ventricular electrograms (EGMs) to distinguish ventricular tachycardia (VT) from supraventricular tachycardia (SVT). Patients undergoing electrophysiologic testing were enrolled. EGMs recorded during induced tachycardias were compared with EGMs recorded during sinus and paced rhythms, taken as templates, by assigning a CWA percent-match (CPM) score. Twenty-two patients were studied: 15 men and 7 women (mean age 48 years); 16 with SVT and 6 with VT. Using a sinus-rhythm template, the atrial CPM scores for SVT and VT were 66%+/- 20% and 93%+/- 5%, respectively (P = 0.0034). With a CPM-score cutoff of 85%, the sensitivity for correctly identifying VT was 100% and the specificity for rejection of SVT was 80%. The corresponding ventricular-CPM scores for SVT and VT were 81%+/- 12% and 72%+/- 24%, respectively (P = 0.13, cutoff = 65%, sensitivity = 50%, and specificity = 90%). Using a ventricular template with atrial pacing, the ventricular-CPM scores for SVT and VT were 87%+/- 9% and 76%+/- 14%, respectively (P = 0.028, cutoff = 70%, sensitivity = 50%, and specificity = 93%). Atrial CWA matching is superior to ventricular CWA matching in discriminating between SVT and VT. CWA matching in both chambers could potentially achieve better discrimination.
BACKGROUND: Morphologic identification of ectopic P-waves from surface ECGs can be challenging, particularly when the P-wave is buried in the QRST wave complex. Because ECGs are often available on paper and not digitally, we developed a method of subtracting the T-wave from the buried P-wave complex on paper ECGs. METHODS: To validate our system, an atrial extrastimulus was introduced during and following the T-wave. The ECGs were scanned and then transformed from an image format to a digital format. A computer algorithm digitally subtracted a QRST with no buried P-wave from one with a buried P-wave, thus resulting in an extracted P-wave. The extracted P-waves were compared to the nonburied P-wave by determining correlation coefficients and by visual grading by two independent reviewers. RESULTS: Visual grading comparing the buried P-wave with the exposed paced P-wave was 94%. The median correlation coefficient was 85%. CONCLUSIONS: An ectopic atrial P-wave obscured by a coincident QRST wave complex can be accurately derived from printed ECG using this PC-based system. Addition of this technique to the existing methods may aid in the localization and ablation of ectopic atrial foci.
Usual assessment of left atrial size by 2-dimensional echocardiography in the anteroposterior dimension often underestimates the true atrial size. We compared 15 young patients (< or =50 years old) with lone paroxysmal atrial fibrillation to age-matched controls, and measured atrial size in the inferosuperior and mediolateral dimensions. These additional measurements and atrial volumes were significantly increased compared with control patients, revealing that patients with apparent "lone" paroxysmal atrial fibrillation may have subtle structural abnormalities of the left atrium.
BACKGROUND: Left ventricular ejection fraction (LVEF) predicts device discharges in patients with implantable cardioverter-defibrillators (ICDs). The relationship between severity of congestive heart failure (CHF) and ICD discharges is less clear. METHODS AND RESULTS: We prospectively analyzed the association between CHF and risk of appropriate ICD discharges in the Triggers Of Ventricular Arrhythmias (TOVA) study, a cohort study of ICD patients conducted at 31 centers in the United States. Reported shocks were confirmed for sustained ventricular tachycardia (VT) or fibrillation (VF) by analysis of stored electrograms. Proportional hazards models included CHF categorized by New York Heart Association class. Baseline CHF was present among 502 (44%) of 1140 patients; 170 (34%) had class I, 230 (46%) had class II, 97 (19%) had class III, and only 5 (1%) had class IV symptoms. During median follow-up of 212 days, 92 patients experienced 1 or more appropriate ICD discharges. Class III CHF was associated in a statistically significantly manner with ICD discharge for VT/VF (hazard ratio 2.40, 95% CI 1.16 to 4.98), even with adjustment for LVEF. The combination of LVEF <0.20 and class III symptoms resulted in a particularly high risk of shocks for VT/VF (hazard ratio 3.90, 95% CI 1.28 to 11.92). CONCLUSIONS: Class III CHF, an easily accessible clinical measure, is an independent risk factor, along with LVEF, for ventricular arrhythmias that require shock therapy among ICD patients. Whether patients with class III CHF benefit to a greater degree from ICDs and whether aggressive treatment of CHF in ICD patients may prevent ventricular arrhythmias remains to be determined.
BACKGROUND: Experimental and clinical evidence suggests a preventive role for agiotensin-coverting enzyme (ACE) inhibitors on the development of atrial fibrillation. However, the effect of ACE inhibition on hospitalization with atrial tachyarrhythmias in patients with left ventricular (LV) dysfunction is not known. We sought to determine whether enalapril treatment reduced hospitalizations with atrial tachyarrhythmias in patients with LV dysfunction. METHODS: We performed a retrospective analysis of the Studies of Left Ventricular Dysfunction (SOLVD) trial. Hospitalizations with atrial tachyarrhythmias were noted. RESULTS: A total of 192 hospitalizations with atrial tachyarrhythmias occurred in 158 patients during a follow-up period of 34 months. The time to first hospitalization with atrial tachyarrhythmias or death was significantly lower in the enalapril group (P =.005). In a multivariate analysis adjusting for the presence of atrial fibrillation at study entry, enalapril treatment was associated with a reduction in the rate of hospitalization with atrial tachyarrhythmias or death (RR, 0.87; 95% CI, 0.79-0.96; P =.007). The incidence of hospitalization with atrial tachyarrhythmias was 7.9 hospitalizations per 1000 patient-years of follow-up in the enalapril group, compared with 12.4 per 1000 patient-years in the placebo group (RR, 0.64; 95% CI, 0.48-0.85; P =.002). CONCLUSION: Enalapril is associated with a decreased incidence of hospitalization with atrial tachyarrhythmias in patients with LV dysfunction.