Search PubMed⌕ Search

Biomedical subjects

Paul A Grayburn

Publications and source records attributed to Paul A Grayburn.

At least 19 recordsLinked to original sources

Monitoring response to anticancer therapy by targeting microbubbles to tumor vasculature.

PURPOSE: New strategies to detect tumor angiogenesis and monitor response of tumor vasculature to therapy are needed. Contrast ultrasound imaging using microbubbles targeted to tumor endothelium offers a noninvasive method for monitoring and quantifying vascular effects of antitumor therapy. We investigated the use of targeted microbubbles to follow vascular response of therapy in a mouse model of pancreatic adenocarcinoma. EXPERIMENTAL DESIGN: Microbubbles conjugated to monoclonal antibodies were used to image and quantify vascular effects of two different antitumor therapies in s.c. and orthotopic pancreatic tumors in mice. Tumor-bearing mice were treated with anti-vascular endothelial growth factor (VEGF) monoclonal antibodies and/or gemcitabine, and the localization of microbubbles to endoglin (CD105), VEGF receptor 2 (VEGFR2), or VEGF-activated blood vessels (the VEGF-VEGFR complex) was monitored by contrast ultrasound. RESULTS: Targeted microbubbles showed significant enhancement of tumor vasculature when compared with untargeted or control IgG-targeted microbubbles. Video intensity from targeted microbubbles correlated with the level of expression of the target (CD105, VEGFR2, or the VEGF-VEGFR complex) and with microvessel density in tumors under antiangiogenic or cytotoxic therapy. CONCLUSIONS: We conclude that targeted microbubbles represent a novel and attractive tool for noninvasive, vascular-targeted molecular imaging of tumor angiogenesis and for monitoring vascular effects specific to antitumor therapy in vivo.

Angiogenesis Inhibitors↗

Effect of body mass index on risk of long-term mortality following coronary artery bypass grafting.

The effect of obesity on long-term mortality after coronary artery bypass grafting (CABG) remains inconclusive, partly due to methodologic issues in previous studies. We examined the effect of obesity on long-term mortality (up to a 6-year follow-up) in adult patients with a body mass index (BMI) > or =18.5 kg/m2 who underwent CABG at Baylor University Medical Center (Dallas, Texas) between January 1998 and August 1999 (n = 1,209). Unadjusted analysis indicated a strong association between BMI and long-term mortality (p = 0.001), with a decreased risk of mortality associated with increasing BMI. After adjusting for factors shown to be confounders of this relation (age, diabetes mellitus, chronic obstructive lung disease, renal failure, ejection fraction, and left main disease), the estimated association was no longer significant (p = 0.425). In conclusion, the apparent survival benefit associated with higher BMI became nonsignificant when the relation between mortality and BMI was adjusted, first for age and then for diabetes mellitus, chronic obstructive lung disease, renal failure, ejection fraction, and left main disease. This relation was masked in the crude analysis primarily by the effect of age. Patients with a high BMI were typically younger than patients with a lower BMI, suggesting that physicians and surgeons may only recommend/perform CABG for patients with a high BMI with an otherwise lower risk profile.

Adult↗

Efficient gene delivery to pancreatic islets with ultrasonic microbubble destruction technology.

This study describes a method of gene delivery to pancreatic islets of adult, living animals by ultrasound targeted microbubble destruction (UTMD). The technique involves incorporation of plasmids into the phospholipid shell of gas-filled microbubbles, which are then infused into rats and destroyed within the pancreatic microcirculation with ultrasound. Specific delivery of genes to islet beta cells by UTMD was achieved by using a plasmid containing a rat insulin 1 promoter (RIP), and reporter gene expression was regulated appropriately by glucose in animals that received a RIP-luciferase plasmid. To demonstrate biological efficacy, we used UTMD to deliver RIP-human insulin and RIP-hexokinase I plasmids to islets of adult rats. Delivery of the former plasmid resulted in clear increases in circulating human C-peptide and decreased blood glucose levels, whereas delivery of the latter plasmid resulted in a clear increase in hexokinase I protein expression in islets, increased insulin levels in blood, and decreased circulating glucose levels. We conclude that UTMD allows relatively noninvasive delivery of genes to pancreatic islets with an efficiency sufficient to modulate beta cell function in adult animals.

Animals↗

The heaviest known operatively-excised aortic valve.

A 60-year-old man whose operatively excised stenotic and regurgitant aortic valve weighed nearly 15 g, approximately 30 times the normal weight in an adult, is described. To the investigators' knowledge, this is the heaviest aortic valve ever encountered in a human being.

Aortic Valve↗

Non-invasive coronary angiography using multislice computed tomography.

Non-invasive methods for detection of coronary atherosclerosis have been limited to indirect markers, such as myocardial perfusion or wall motion during exercise or pharmacological stress. However, advances in multislice computed tomography (MSCT) not allow sufficient spatial resolution for direct non-invasive imaging of the coronary arteries. This review focuses on imaging techniques and clinical applications of MSCT in human studies. Published studies of the diagnostic accuracy of MSCT in native coronary arteries and bypass grafts indicate excellent sensitivity and specificity for detection of 50% diameter stenosis. MSCT is particularly good for evaluating the origin and course of anomalous coronary arteries. MSCT offers the ability to visualise both the lumen and wall of artery, as well as to quantify coronary classification. Further technical developments promise to render MSCT the ideal non-invasive tool for direct visualisation of the coronary arteries.

Calcinosis↗

Migration of an amplatzer septal occluder device for closure of atrial septal defect into the ascending aorta with formation of an aorta-to-right atrial fistula.

The percutaneous closure of atrial septal defects is increasingly used. Serious complications of the procedure, such as cardiac perforation and tamponade, are rare and usually occur <72 hours after device placement. The investigators report the late development of the erosion of an Amplatzer septal occluder into the ascending aorta with associated aortic-to-right atrial fistula formation.

Adult↗

Valvular heart disease: aortic regurgitation.

Aortic regurgitation (AR) is characterized by diastolic reflux of blood from the aorta into the left ventricle (LV). Acute AR typically causes severe pulmonary edema and hypotension and is a surgical emergency. Chronic severe AR causes combined LV volume and pressure overload. It is accompanied by systolic hypertension and wide pulse pressure, which account for peripheral physical findings, such as bounding pulses. The afterload excess caused by systolic hypertension leads to progressive LV dilation and systolic dysfunction. The most important diagnostic test for AR is echocardiography. It provides the ability to determine the cause of AR and to assess the severity of AR and its effect on LV size, function, and hemodynamics. Many patients with chronic severe AR may remain clinically compensated for years with normal LV function and no symptoms. These patients do not require surgery but can be followed carefully for the onset of symptoms or LV dilation/dysfunction. Surgery should be considered before the LV ejection fraction falls below 55% or the LV end-systolic [corrected] dimension reaches 55 mm. Symptomatic patients should undergo surgery unless there are excessive comorbidities or other contraindications. The primary role of medical therapy with vasodilators is to delay the need for surgery in asymptomatic patients with normal LV function or to treat patients in whom surgery is not an option. The goal of vasodilator therapy is to achieve a significant decrease in systolic arterial pressure. Future therapies may focus on molecular mechanisms to prevent adverse LV remodeling and fibrosis.

Aortic Valve Insufficiency↗

Relation of echocardiographic wall motion score index and response to dobutamine stress to defibrillation threshold at the time of implantation of a cardiac defibrillator.

Predictors of defibrillation threshold (DFT) at implantation remain poorly defined. It was hypothesized that a greater wall motion score index (WMSI) at rest on echocardiography and an ischemic or biphasic response on dobutamine stress echocardiography (DSE) would predict a greater DFT. Consecutive patients who underwent implantable cardiac-defibrillator implantation underwent echocardiography and DSE. DFT at implantation was assessed using the step-down method. Thirteen men aged 68 +/- 10 years with left ventricular ejection fractions of 28 +/- 10% participated in the study. DFTs ranged from 5 to 25 J (mean 14 +/- 8). A WMSI at rest of > or = 2.5 had a 71% positive predictive value and an 83% negative predictive value for a DFT > or = 15 J. An ischemic or biphasic response during DSE did not predict a greater DFT at implantation.

Aged↗

Effect on right ventricular volume of percutaneous Amplatzer closure of atrial septal defect in adults.

In adult patients with atrial septal defects (ASDs), right ventricular (RV) cavity size may return to normal after operative closure. This study demonstrated improved RV volumes and right atrial areas in 20 adult patients after successful transcatheter closure of large ASDs. RV volumes decreased by 22%, 30%, and 41% at 1 day, 1 month, and 6 months, respectively, after the procedure. Right atrial areas decreased by 5%, 23%, and 26%, respectively, over the same time.

Adult↗

Echocardiographic predictors of morbidity and mortality in patients with advanced heart failure: the Beta-blocker Evaluation of Survival Trial (BEST).

OBJECTIVES: The aim of this study was to determine echocardiographic predictors of outcome in patients with advanced heart failure (HF) due to severe left ventricular (LV) systolic dysfunction in the Beta-blocker Evaluation of Survival Trial (BEST). BACKGROUND: Previous studies indicate that echocardiographic measurements of LV size and function, mitral deceleration time, and mitral regurgitation (MR) predict adverse outcomes in HF. However, complete quantitative echocardiograms evaluating all of these parameters have not been reported in a prospective randomized clinical trial in the era of modern HF therapy. METHODS: Complete echocardiograms were performed in 336 patients at 26 sites and analyzed by a core laboratory. A Cox proportional-hazards regression model was used to determine which echocardiographic variables predicted the primary end point of death or the secondary end point of death, HF hospitalization, or transplant. Significant variables were then entered into a multivariable model adjusted for clinical and demographic covariates. RESULTS: On multivariable analysis adjusted for clinical covariates, only LV end-diastolic volume index predicted death (events = 75), with a cut point of 120 ml/m(2). Three echocardiographic variables predicted the combined end point of death (events = 75), HF hospitalization (events = 97), and transplant (events = 9): LV end-diastolic volume index, mitral deceleration time, and the vena contracta width of MR. Optimal cut points for these variables were 120 ml/m(2), 150 ms, and 0.4 cm, respectively. CONCLUSIONS: Echocardiographic predictors of outcome in advanced HF include LV end-diastolic volume index, mitral deceleration time, and vena contracta width. These variables indicate that LV remodeling, increased LV stiffness, and MR are independent predictors of outcome in patients with advanced HF.

Echocardiography, Doppler↗

Use of ultrasound contrast agents for gene or drug delivery in cardiovascular medicine.

The clinical utility of ultrasound contrast agents has been established in diagnostic echocardiography. Recently, the use of such agents has been promoted for transport and delivery of various bioactive substances, thus providing a technique for non-invasive gene therapy and organ-specific drug delivery. In this review, we give a critical update of published studies using ultrasound contrast agents for therapeutic use. We discuss the potential applications and limitations of this technique and suggest future applications in cardiovascular medicine.

Cardiovascular Diseases↗

Augmentation of cardiac protein delivery using ultrasound targeted microbubble destruction.

Gas-filled microbubbles have become an important tool as ultrasonic contrast agents. We have previously shown that ultrasound-targeted microbubble destruction (UTMD) can direct plasmids to the heart. The aim of this study was to evaluate UTMD for protein delivery. Six different groups of rats received 1 microg of luciferase protein with varying protocols: (1) luciferase-loaded microbubbles and ultrasound; (2) luciferase only; (3) luciferase and ultrasound; (4) luciferase-loaded microbubbles; (5) unloaded microbubbles incubated with luciferase and ultrasound; (6) unloaded microbubbles with ultrasound followed by luciferase. Relative luminescence units per mg protein per s were determined in hearts and control organs. The rats that received ultrasound and luciferase-loaded bubbles showed a six-fold higher cardiac luciferase uptake compared with control groups that did not include bubbles. None of the other groups significantly augmented cardiac luciferase activity. We conclude that ultrasound-targeted microbubble destruction can substantially and noninvasively augment organ-specific delivery of proteins.

Animals↗

Targeting vascular endothelium with avidin microbubbles.

Targeting microbubbles (MBs) to specific vascular beds enables contrast ultrasound to be used for molecular imaging. There are several methods for attaching targeting moieties to the surface of MBs. In the present study, we demonstrate that avidin (Av) can be incorporated into the shell of perfluorocarbon-exposed sonicated dextrose albumin (PESDA) MBs (Av-PESDA-MBs) and serve as an anchor that links Av-PESDA-MBs to biotinylated monoclonal antibodies (mAbs). This novel linking strategy was used to conjugate Av-PESDA-MBs to mAbs specific for endoglin (CD105) or a control IgG. MBs targeted to CD105 specifically bound to endothelial cells, but not to fibroblasts, in vitro but Av-PESDA-MBs conjugated with the control IgG did not specifically target either cell type. We conclude that Av-PESDA-MBs represent a novel and attractive tool to conjugate MBs with biotinylated mAbs for the purposes of vascular targeting and molecular imaging.

Animals↗

Comparison of B-type natriuretic peptide levels in patients with heart failure with versus without mitral regurgitation.

Functional mitral regurgitation (MR) occurs most often in patients with heart failure (HF) and is associated with an adverse prognosis. Recently, B-type natriuretic peptide (BNP) has been validated as a marker of cardiac function and prognosis. We sought to assess the relation between functional MR and BNP levels in patients with HF, and hypothesized that MR is associated with higher BNP levels. In all, 201 patients admitted with the diagnosis of HF had a transthoracic echocardiogram and measurement of BNP levels within 48 hours. MR was graded as none/trace, mild, moderate, or severe using recently published guidelines of the American Society of Echocardiography. BNP was measured by a commercially available instrument (Biosite). The relation of MR to BNP was assessed using multivariable linear regression methods with a Tobin estimation to account for the truncation of BNP values at an upper limit of 1,300 pg/ml. Mean age of the patients was 67 +/- 11 years. The median BNP level was 826 pg/ml. The etiology of HF was predominantly diastolic in 64 patients (32%); 137 patients (68%) had significant left ventricular (LV) systolic dysfunction. Mean LV ejection fraction was 37 +/- 17%. MR was present in 112 patients (56%). After adjusting for clinical, hemodynamic, and echocardiographic variables, only LV ejection fraction (p = 0.016) and moderate or severe MR (p = 0.023) were significantly associated with BNP. When MR was grouped as any MR versus no MR, only LV ejection fraction (p = 0.017) and any degree of MR (p = 0.029) were significantly associated with BNP.

Aged↗