Long-term stability by lipid coating monodisperse microbubbles formed by a flow-focusing device.

In this letter, the long-term stabilization of monodisperse microbubbles produced by flow focusing is demonstrated using lipid encapsulation. Fluorescence microscopy, high-speed camera imaging, and particle size analysis were used to investigate the roles of lipid phase behavior, dissolution, Ostwald ripening, and coalescence in the stability of microbubbles formed by flow focusing. It was found that these behaviors were controlled through compositional changes with respect to lipid, emulsifier, and viscosity agents. Microbubbles coated with lipid and PEG emulsifier in a viscous solution were found to contain an extremely narrow size distribution (diameter(av) = 51 microm, standard deviation = 4 microm), which was maintained for up to several months.

Microbubbles↗

Lateral phase separation in lipid-coated microbubbles.

In the design of lipid-coated microbubble ultrasound contrast agents for molecular imaging and targeted drug delivery, the surface distribution of the shell species is important because it dictates such properties as ligand location, brush coverage, and amount of drug loading. We used a combination of spectroscopy and microscopy techniques to test the prevailing notion that the main phosphatidyl choline (PC) and lipopolymer species are completely miscible within the monolayer shell. NMR spectroscopy showed that the shell composition is roughly equivalent to the bulk lipid ratio. FTIR spectroscopy showed a sharp melting peak corresponding to the main phase-transition temperature of the main PC species, with no observed pretransitions while scanning from room temperature, indicating a single PC-rich ordered phase. Electron and fluorescence microscopy showed a heterogeneous microstructure with dark (ordered) domains and bright (disordered) regions. Domain formation was thermotropic and reversible. Fluorescent labeling of the lipopolymer following shell formation showed that it partitions preferentially into the disordered interdomain regions. The ordered domains, therefore, are composed primarily of PC, and the disordered interdomain regions are enriched in lipopolymer. Phase heterogeneity was observed at all lipopolymer concentrations (0.5 to 20 mol %), and the degree of phase separation increased with lipopolymer content. The composition and temperature dependence of the microstructure indicates that phase separation is driven thermodynamically rather than being a kinetically trapped relic of the shell-formation process. The overall high variation in microstructure, including the existence of anomalous three-phase coexistence, highlights the nonequilibrium (history-dependent) nature of the monolayer shell.

Coated Materials, Biocompatible↗

Ultrasound assessment of angiogenesis in a matrigel model in rats.

Matrigel, a basement membrane extract, has been extensively used in in vivo angiogenesis. Contrast ultrasound imaging (CUI) of implanted Matrigel plugs with (+bFGF) and without basic fibroblast growth factor (-bFGF) was performed 7 and 14 d after implantation, followed by histologic analysis. Statistically significant differences between +bFGF and -bFGF plugs were apparent at d 7 in both plug size and contrast enhancement (both p < 0.05). Histopathology revealed differences in microvessel density (MVD) between +bFGF and -bFGF at d 7 and d 14. A significant correlation between MVD and both power Doppler contrast-enhanced area (r = 0.65, p < 0.05) and fraction of plug enhanced (r = 0.59, p < 0.05) was present. CUI of Matrigel plugs was shown to be a robust method for distinguishing between two different angiogenic states. Ultrasound measurements of blood flow in the plugs correlated with MVD, a histologic technique used to quantify tumor angiogenesis.

Animals↗

Observation of contrast agent response to chirp insonation with a simultaneous optical-acoustical system.

Rayleigh-Plesset analysis, ultra-high speed photography, and single bubble acoustical recordings previously were applied independently to characterize the radial oscillation and resulting echoes from a microbubble in response to an ultrasonic pulse. In addition, high-speed photography has shown that microbubbles are destroyed over a single pulse or pulse train by diffusion and fragmentation. In order to develop a single model to characterize microbubble echoes based on oscillatory and destructive characteristics, an optical-acoustical system was developed to simultaneously record the optical image and backscattered echo from each microbubble. Combined observation provides the opportunity to compare predictions for oscillation and echoes with experimental results and identify discrepancies due to diffusion or fragmentation. Optimization of agents and insonating pulse parameters may be facilitated with this system. The mean correlation of the predicted and experimental radius-time curves and echoes exceeds 0.7 for the parameters studied here. An important application of this new system is to record and analyze microbubble response to a long pulse in which diffusion is shown to occur over the pulse duration. The microbubble response to an increasing or decreasing chirp is evaluated using this new tool. For chirp insonation beginning with the lower center frequency, low-frequency modulation of the oscillation envelope was obvious. However, low-frequency modulation was not observed in the radial oscillation produced by decreasing chirp insonation. Comparison of the echoes from similar sized microbubbles following increasing and decreasing chirp insonation demonstrated that the echoes were not time-reversed replicas. Using a transmission pressure of 620 kPa, the -6 dB echo length was 0.9 and 1.1 micros for increasing and decreasing chirp insonation, respectively (P = 0.02). The mean power in the low-frequency portion of the echoes was 8 (mV)2 and 13 (mV)2 for increasing and decreasing chirp insonation, respectively (P = 0.01).

Acoustics↗

Acoustic response from adherent targeted contrast agents.

In ultrasonic molecular imaging, encapsulated micron-sized gas bubbles are tethered to a blood vessel wall by targeting ligands. A challenging problem is to detect the echoes from adherent microbubbles and distinguish them from echoes from nonadherent agents and tissue. Echoes from adherent contrast agents are observed to include a high amplitude at the fundamental frequency, and significantly different spectral shape compared with free agents (p <0.0003). Mechanisms for the observed acoustical difference and potential techniques to utilize these differences for molecular imaging are proposed.

Acoustics↗

Ultrasound radiation force modulates ligand availability on targeted contrast agents.

Radiation force produced by low-amplitude ultrasound at clinically relevant frequencies remotely translates freely flowing microbubble ultrasound contrast agents over distances up to centimeters from the luminal space to the vessel wall in order to enhance ligand-receptor contact in targeting applications. The question arises as to how the microbubble shell might be designed at the molecular level to fully take advantage of such physical forces in targeted adhesion for molecular imaging and controlled therapeutic release. Herein, we report on a novel surface architecture in which the tethered ligand is buried in a polymeric overbrush. Our results, with biotin-avidin as the model ligand-receptor pair, show that the overbrush conceals the ligand, thereby reducing immune cell binding and increasing circulation persistence. Targeted adhesion is achieved through application of ultrasound radiation force to instantly reveal the ligand within a well-defined focal zone and simultaneously bind the ligand and receptor. Our data illustrate how the adhesive properties of the contrast agent surface can be reversibly changed, from stealth to sticky, through the physical effects of ultrasound. This technique can be combined with any ligand-receptor pair to optimize targeted adhesion for ultrasonic molecular imaging.

Animals↗

Application of ultrasound to selectively localize nanodroplets for targeted imaging and therapy.

Lipid-coated perfluorocarbon nanodroplets are submicrometer-diameter liquid-filled droplets with proposed applications in molecularly targeted therapeutics and ultrasound (US) imaging. Ultrasonic molecular imaging is unique in that the optimal application of these agents depends not only on the surface chemistry, but also on the applied US field, which can increase receptor-ligand binding and membrane fusion. Theory and experiments are combined to demonstrate the displacement of perfluorocarbon nanoparticles in the direction of US propagation, where a traveling US wave with a peak pressure on the order of megapascals and frequency in the megahertz range produces a particle translational velocity that is proportional to acoustic intensity and increases with increasing center frequency. Within a vessel with a diameter on the order of hundreds of micrometers or larger, particle velocity on the order of hundreds of micrometers per second is produced and the dominant mechanism for droplet displacement is shown to be bulk fluid streaming. A model for radiation force displacement of particles is developed and demonstrates that effective particle displacement should be feasible in the microvasculature. In a flowing system, acoustic manipulation of targeted droplets increases droplet retention. Additionally, we demonstrate the feasibility of US-enhanced particle internalization and therapeutic delivery.

Blood Vessels↗

Ultrasound radiation force enables targeted deposition of model drug carriers loaded on microbubbles.

A novel drug delivery vehicle that specifically targets using ultrasound radiation force (USRF) and biotin-avidin interactions is presented. Model vehicles consist of avidinated fluorescent nanobeads bound directly to the biotinylated lipid shells of preformed microbubbles. USRF was used to deflect the vehicle from the center of flow to a tube surface in order to facilitate receptor-ligand mediated adhesion. At wall shear stress levels commensurate with venous and arterial flow, USRF was used to direct the vehicles to a biotinylated tube surface. Subsequent high-pressure pulses fragmented the carrier, and molecular interactions induced deposition of the nanobeads on the wall. Targeting of nanobeads to the tube was molecularly specific and dependent on, in order of importance, vehicle concentration, wall shear stress, nanobead size, and insonation time. The observation that portions of the microbubble lipid monolayer shell remain attached to adherent nanobeads is important for future consideration of drug transport mechanisms. This versatile method of delivery is shown to enable targeted deposition of nanoparticles in shear flow and could be modified to carry therapeutic agents for controlled release in targeted delivery applications.

Avidin↗

Asymmetric oscillation of adherent targeted ultrasound contrast agents.

With a lipid shell containing biotin, micron-sized bubbles bound to avidin on a porous and flexible cellulose boundary were insonified by ultrasound. The oscillation of these targeted microbubbles was observed by high-speed photography and compared to the oscillation of free-floating microbubbles. Adherent microbubbles were observed to oscillate asymmetrically in the plane normal to the boundary, and nearly symmetrically in the plane parallel to the boundary, with a significantly smaller maximum expansion in each dimension for bound than free bubbles. With sufficient transmitted pressure, a jet was produced traveling toward the boundary.

Journal Article↗

High-frequency dynamics of ultrasound contrast agents.

Ultrasound contrast agents enhance echoes from the microvasculature and enable the visualization of flow in smaller vessels. Here, we optically and acoustically investigate microbubble oscillation and echoes following insonation with a 10 MHz center frequency pulse. A high-speed camera system with a temporal resolution of 10 ns, which provides two-dimensional (2-D) frame images and streak images, is used in optical experiments. Two confocally aligned transducers, transmitting at 10 MHz and receiving at 5 MHz, are used in acoustical experiments in order to detect subharmonic components. Results of a numerical evaluation of the modified Rayleigh-Plesset equation are used to predict the dynamics of a microbubble and are compared to results of in vitro experiments. From the optical observations of a single microbubble, nonlinear oscillation, destruction, and radiation force are observed. The maximum bubble expansion, resulting from insonation with a 20-cycle, 10-MHz linear chirp with a peak negative pressure of 3.5 MPa, has been evaluated. For an initial diameter ranging from 1.5 to 5 microm, a maximum diameter less than 8 microm is produced during insonation. Optical and acoustical experiments provide insight into the mechanisms of destruction, including fragmentation and active diffusion. High-frequency pulse transmission may provide the opportunity to detect contrast echoes resulting from a single pulse, may be robust in the presence of tissue motion, and may provide the opportunity to incorporate high-frequency ultrasound into destruction-replenishment techniques.

Contrast Media↗

Influence of lipid shell physicochemical properties on ultrasound-induced microbubble destruction.

We present the first study of the effects of monolayer shell physicochemical properties on the destruction of lipid-coated microbubbles during insonification with single, one-cycle pulses at 2.25 MHz and low-duty cycles. Shell cohesiveness was changed by varying phospholipid and emulsifier composition, and shell microstructure was controlled by postproduction processing. Individual microbubbles with initial resting diameters between 1 and 10 microm were isolated and recorded during pulsing with bright-field and fluorescence video microscopy. Microbubble destruction occurred through two modes: acoustic dissolution at 400 and 600 kPa and fragmentation at 800 kPa peak negative pressure. Lipid composition significantly impacted the acoustic dissolution rate, fragmentation propensity, and mechanism of excess lipid shedding. Less cohesive shells resulted in micron-scale or smaller particles of excess lipid material that shed either spontaneously or on the next pulse. Conversely, more cohesive shells resulted in the buildup of shell-associated lipid strands and globular aggregates of several microns in size; the latter showed a significant increase in total shell surface area and lability. Lipid-coated microbubbles were observed to reach a stable size over many pulses at intermediate acoustic pressures. Observations of shell microstructure between pulses allowed interpretation of the state of the shell during oscillation. We briefly discuss the implications of these results for therapeutic and diagnostic applications involving lipid-coated microbubbles as ultrasound contrast agents and drug/gene delivery vehicles.

Coated Materials, Biocompatible↗

A method for radiation-force localized drug delivery using gas-filled lipospheres.

We have developed a method using ultrasound and acoustically active lipospheres (AALs) that might be used to deliver bioactive substances to the vascular endothelium. The AALs consist of a small gas bubble surrounded by a thick oil shell and enclosed by an outermost lipid layer. The AALs are similar to ultrasound contrast agents: they can be nondestructively deflected using ultrasound radiation force, and fragmented with high-intensity ultrasound pulses. The lipid-oil complex might be used to carry bioactive substances at high concentrations. An optimized sequence of ultrasound pulses can deflect the AALs toward a vessel wall then disrupt them, painting their contents across the vascular endothelium. This paper presents results from a series of in vitro and ex vivo experiments demonstrating localization of a fluorescent model drug. In experiments using a human melanoma cell (A2085) monolayer, a specific radiation force-fragmentation ultrasound pulse sequence increased cell fluorescence more than 10-fold over no ultrasound or fragmentation pulses alone, and by 50% over radiation force pulses alone. We observe that dye transfer is limited to cells that are in the region of ultrasonic focus, indicating that the application of radiation force pulses to bring the delivery vehicle into proximity with the cell is required for successful adhesion of the vehicle fragments to the cell membrane. We also demonstrate dye transfer from flowing AALs, both in a mimetic vessel and in excised rat cecum. We believe that this method could be successfully used for drug delivery in vivo.

Animals↗

Ultrasonic analysis of peptide- and antibody-targeted microbubble contrast agents for molecular imaging of alphavbeta3-expressing cells.

The goal of targeted ultrasound contrast agents is to significantly and selectively enhance the detection of a targeted vascular site. In this manuscript, three distinct contrast agents targeted to the alphavbeta3 integrin are examined. The alphavbeta3 integrin has been shown to be highly expressed on metastatic tumors and endothelial cells during neovascularization, and its expression has been shown to correlate with tumor grade. Specific adhesion of these contrast agents to alphavbeta3-expressing cell monolayers is demonstrated in vitro, and compared with that of nontargeted agents. Acoustic studies illustrate a backscatter amplitude increase from monolayers exposed to the targeted contrast agents of up to 13-fold (22 dB) relative to enhancement due to control bubbles. A linear dependence between the echo amplitude and bubble concentration was observed for bound agents. The decorrelation of the echo from adherent targeted agents is observed over successive pulses as a function of acoustic pressure and bubble density. Frequency-domain analysis demonstrates that adherent targeted bubbles exhibit high-amplitude narrowband echo components, in contrast to the primarily wideband response from free microbubbles. Results suggest that adherent targeted contrast agents are differentiable from free-floating microbubbles, that targeted contrast agents provide higher sensitivity in the detection of angiogenesis, and that conventional ultrasound imaging techniques such as signal subtraction or decorrelation detection can be used to detect integrin-expressing vasculature with sufficient signal-to-noise.

Antibodies↗

Radiation-force assisted targeting facilitates ultrasonic molecular imaging.

Ultrasonic molecular imaging employs contrast agents, such as microbubbles, nanoparticles, or liposomes, coated with ligands specific for receptors expressed on cells at sites of angiogenesis, inflammation, or thrombus. Concentration of these highly echogenic contrast agents at a target site enhances the ultrasound signal received from that site, promoting ultrasonic detection and analysis of disease states. In this article, we show that acoustic radiation force can be used to displace targeted contrast agents to a vessel wall, greatly increasing the number of agents binding to available surface receptors. We provide a theoretical evaluation of the magnitude of acoustic radiation force and show that it is possible to displace micron-sized agents physiologically relevant distances. Following this, we show in a series of experiments that acoustic radiation force can enhance the binding of targeted agents: The number of biotinylated microbubbles adherent to a synthetic vessel coated with avidin increases as much as 20-fold when acoustic radiation force is applied; the adhesion of contrast agents targeted to alpha(v)beta3 expressed on human umbilical vein endothelial cells increases 27-fold within a mimetic vessel when radiation force is applied; and finally, the image signal-to-noise ratio in a phantom vessel increases up to 25 dB using a combination of radiation force and a targeted contrast agent, over use of a targeted contrast agent alone.

Avidin↗

Acoustic signatures of submicron contrast agents.

Previous studies have revealed that hard-shelled submicron contrast agents exhibit large relative expansions and strong acoustical echoes that can be observed experimentally, and predicted by theoretical simulations. In this paper, we study harmonic imaging and pulse-pair imaging techniques designed to assist in the differentiation of these contrast agents from tissue. For harmonic imaging, we apply a high-sensitivity, narrowband strategy that differentiates the microbubble from tissue based on the generation of strong harmonic echoes. For pulse-pair imaging, we apply high spatial resolution, wideband strategies using phase inversion, which relies on the frequency differences observed in response to phase-inverted pulses, and signal subtraction, which takes advantage of the amplitude differences in response to identical pulses. The bubble-to-phantom signal amplitude ratio in the absence of motion approaches 20 dB using phase inversion and 30 dB using signal subtraction; both techniques are robust for up to 50 microm of simulated motion. With the experience gained in these studies, we hope to advance the development of multi-pulse or shaped-pulse techniques that are optimized for specific clinical applications.

Connective Tissue↗

Effect of coupled oscillations on microbubble behavior.

Ultrasound contrast agents are encapsulated microbubbles whose nonlinear acoustic scattering signatures have been the foundation of their use in diagnostic imaging. The coupled oscillations of microbubbles along their lines of center are investigated theoretically using radial equations in the monopole approximation and an energy balance, which is obtained for the system. Coupled microbubble pairs of different initial radii are investigated numerically relative to the normal modes for the linearized system. For microbubble pairs of different size bubbles driven below the mode of the smaller bubble and above the mode of the larger bubble, it is shown that oscillations of the smaller agent are affected substantially more by the coupling than those of the larger one. For separation distances of 10 and 500 microns, a difference of approximately 10 dB occurs in the second harmonic output of a 1.0-micron radius agent coupled with a 2.2-micron radius agent forced at 2.0 MHz and 0.3 MPa. The subharmonic spectral peak is shown to decrease approximately 19 dB for the coupling of 1.5- and 2.2-micron radius agents at 10- and 500-micron distances under the same acoustic forcing conditions. These coupling effects on the radiated pressure and its spectral power are highlighted for contrast agent imaging applications.

Humans↗

Targeted imaging using ultrasound.

The discipline of medical imaging is expanding to include both traditional anatomic modalities and new techniques for the functional assessment of the presence and extent of disease. Current FDA-approved ultrasound contrast agents are micron-sized bubbles with a stabilizing shell. Microbubble contrast agents can be used to estimate microvascular flow rate in a manner similar to dynamic contrast-enhanced magnetic resonance imaging (MRI). The concentration of these agents within the vasculature, reticulo-endothelial, or lymphatic systems produces an effective passive targeting of these areas. Liquid-filled nanoparticles and liposomes have also demonstrated echogenicity and are under evaluation as ultrasound contrast agents. Actively targeted ultrasound relies on specially designed contrast agents to localize the targeted molecular signature or physiologic system. These agents typically remain within the vascular space, and therefore possible targets include molecular markers on thrombus, endothelial cells, and leukocytes. The purpose of this review is to summarize the requirements, challenges, current progress, and future directions of targeted imaging with ultrasound.

Animals↗

The magnitude of radiation force on ultrasound contrast agents.

High-speed photography of insonified bubbles with a time resolution of 10 ns allows observations of translation due to radiation force, in addition to the visualization of radial oscillations. A modified version of the Rayleigh-Plesset equation is used to estimate the radius-time behavior of insonified microbubbles, and the accuracy of this model is verified experimentally. The translation of insonified microbubbles is calculated using a differential equation relating the acceleration of the bubble to the forces due to acoustic radiation and the drag imposed by the fluid. Simulations and experiments indicate that microbubbles translate significant distances with clinically relevant parameters. A 1.5 micron radius contrast agent can translate over 5 microns during a single 20-cycle, 2.25 MHz, 380 kPa acoustic pulse, achieving velocities over 0.5 m/s. Therefore, radiation force should be considered during an ultrasonic examination because of the possibility of influencing the position and flow velocity of the contrast agents with the interrogating acoustic beam.

Contrast Media↗