Search PubMed⌕ Search

Biomedical subjects

Pascal Senn

Publications and source records attributed to Pascal Senn.

7 recordsLinked to original sources

Differential distribution of stem cells in the auditory and vestibular organs of the inner ear.

The adult mammalian cochlea lacks regenerative capacity, which is the main reason for the permanence of hearing loss. Vestibular organs, in contrast, replace a small number of lost hair cells. The reason for this difference is unknown. In this work we show isolation of sphere-forming stem cells from the early postnatal organ of Corti, vestibular sensory epithelia, the spiral ganglion, and the stria vascularis. Organ of Corti and vestibular sensory epithelial stem cells give rise to cells that express multiple hair cell markers and express functional ion channels reminiscent of nascent hair cells. Spiral ganglion stem cells display features of neural stem cells and can give rise to neurons and glial cell types. We found that the ability for sphere formation in the mouse cochlea decreases about 100-fold during the second and third postnatal weeks; this decrease is substantially faster than the reduction of stem cells in vestibular organs, which maintain their stem cell population also at older ages. Coincidentally, the relative expression of developmental and progenitor cell markers in the cochlea decreases during the first 3 postnatal weeks, which is in sharp contrast to the vestibular system, where expression of progenitor cell markers remains constant or even increases during this period. Our findings indicate that the lack of regenerative capacity in the adult mammalian cochlea is either a result of an early postnatal loss of stem cells or diminishment of stem cell features of maturing cochlear cells.

Animals↗

Patients with mild traumatic brain injury: immediate and long-term outcome compared to intra-cranial injuries on CT scan.

BACKGROUND: Mild traumatic brain injury (MTBI) defined as Glasgow Coma Scale (GCS) 14 or 15 has shown contradictory short- and long-term outcomes. The objective of this study was to correlate intra-cranial injuries (ICI) on CT scan to neurocognitive tests at admission and to complaints after 1 year. METHODS: Two hundred and five patients with MTBI underwent a CT scan and were examined with neurocognitive tests. After 1 year complaints were assessed by phone interviews. RESULTS: The neurocognitive tests in 51% of the patients showed significant deficits; there was no difference for patients with GCS 14-15, nor was there a difference between patients with ICI to patients without. After 1 year patients with ICI had significantly more complaints than patients without ICI, the most frequent complaint was headache and memory deficits. CONCLUSIONS: No correlation was found between GCS or ICI and the neurocognitive tests upon admission. After 1 year, patients with ICI have significantly more complaints than patients without ICI. No cost savings resulted by doing immediate CT scan on all.

Adolescent↗

Minimum audible angle, just noticeable interaural differences and speech intelligibility with bilateral cochlear implants using clinical speech processors.

Sound localization and speech intelligibility were assessed in 5 patients implanted bilaterally with Medel C40+ or Medel C40 cochlear implant (CI) systems. The minimum audible angle (MAA) around the head in the horizontal plane was assessed in patients with bilateral CI using white noise bursts of 1000 ms duration presented from a loudspeaker mounted on a rotating boom and compared with the MAA of age-matched normal hearing controls. Spatial discrimination was found to be good in front and in the back of the head with near-normal MAA values (patients: 3-8 degrees , controls: 1-4 degrees ). In contrast, poor performance on the sides was found (patients: 30 to over 45 degrees , controls 7-10 degrees ). Bilateral CI significantly improved spatial discrimination in front for all patients, when compared with the use of either CI alone. Just noticeable differences (JNDs) in interaural intensity and time were assessed using white noise bursts (1000 ms duration; 50 ms linear ramp). In addition, interaural time JNDs were assessed using click trains (800 ms duration, 40 mus clicks, 50 Hz) and noise bursts in which either only the envelope or only the fine structure was shifted in time. In comparison with normal hearing controls, patients with bilateral CI showed near-normal interaural intensity JNDs but substantially poorer interaural time JNDs depending on the type of stimulus. In contrast to envelope onset/offset cues, interaural fine structure time differences were not perceived by the patients using CI systems employing the continuous interleaved sampling strategy without synchronization between their pulse stimulation times. Speech intelligibility in quiet and CCITT noise from the side (+/-90 degrees ) was assessed using the German HSM sentence test and was significantly better when using bilateral CI in comparison with either unilateral CI, mainly due to a head shadow effect. These favorable results are in agreement with the patients' subjective experiences assessed with a questionnaire and support the use of bilateral CI.

Adolescent↗

Novel slow- and fast-type drug release round-window microimplants for local drug application to the cochlea: an experimental study in guinea pigs.

Novel drug release microimplants (0.8 x 1.14 mm; custom-made by Leiras, now Schering OY, Finland) of slow- and fast-release types containing either 0.9 mg beclomethasone or no drug at all were placed unilaterally onto the round-window membrane (RWM) of 45 guinea pigs for a maximum duration of 28 days. The following parameters were tested on days 1, 14 and 28 after implantation: threshold levels of beclomethasone in the perilymph of the scala tympani, auditory brain stem responses (ABR thresholds and ABR threshold shifts), RWM morphology and hair cell loss (cytocochleograms). None of the animals in the non-implanted control group (n = 5) or placebo implant group (n = 15), but all animals in the slow-release-type implant group (n = 15) and fast-release-type implant group (n = 15) revealed the presence of beclomethasone on day 1 (34.9 and 64.3 pg/microl, respectively), day 14 (43.8 and 46.9 pg/microl, respectively) and day 28 after implantation (4.7 and 60.5 pg/microl, respectively). Histology of the RWMs appeared normal, and cytocochleograms revealed no inner hair cell loss and outer hair cell loss within normal ranges (from 0.5 +/- 0.4 to 0.8 +/- 0.2% per cochlea) in both ears in all experimental groups at any time during examination (days 1, 14 and 28). Initial values of ABR thresholds at 3, 6, 9 and 12 kHz did not differ significantly in any of the experimental groups. In non-implanted controls, no significant differences of ABR thresholds were observed in all frequencies tested in either ear on days 1, 14 and 28 compared to initial values, and ABR threshold shifts ranged from -3 +/- 5 dB (min.) to +5 +/- 7 dB (max.). On day 28 after implantation, there were no significant differences of ABR threshold shifts between this and the implant groups, except for 6 kHz of the slow-release device. Therefore, the placebo implants, the slow-release and the fast-release beclomethasone implants appear suitable for further experiments.

Animals↗

Severe complications after intrathecal methotrexate (MTX) for treatment of primary central nervous system lymphoma (PCNSL).

Primary central nervous system lymphoma (PCNSL) is a rare and highly malignant tumor with increasing incidence. Survival has improved with the use of nonsurgical treatment modalities, of which methotrexate (MTX)-based intrathecal chemotherapy has been an important option. Here, we describe devastating complications in three patients with diffuse large B-cell lymphomas. After intrathecal MTX therapy two patients died secondary to fulminant brain edema. A third patient developed severe dementia, gait disturbance and urinary incontinence due to leukencephalopathy. Since bulky disease was present in all three patients, CSF flow may have been impaired. This might have exposed adjacent tissue to prolonged toxic drug concentrations. Regarding the severe complications seen in these patients, it is useful to consider high-dose intravenous MTX treatment only in periventricular PCNSL.

Adult↗

Scuba diving with cochlear implants.

We report on a patient with bilateral cochlear implants (a Med-El Combi40 and a Med-El Combi40+), as well as considerable experience in scuba diving with both of his implants. After having been exposed to 68 and 89 dives, respectively, in depths of up to 43 m, both cochlear implants are in working order and the patient continues to receive excellent speech recognition scores with both cochlear implant systems. The presented data show that scuba diving after cochlear implantation is possible over a considerable number of dives without any major negative impact on the implants.

Cochlear Implants↗

Contrast-enhanced 3D MR angiography of the carotid artery: comparison with conventional digital subtraction angiography.

BACKGROUND AND PURPOSE: Since 1996, several preliminary studies have shown the usefulness of contrast material-enhanced MR angiography for imaging supraaortic vessels. The aim of this study was to compare the accuracy of contrast-enhanced 3D MR angiography with that of digital subtraction angiography (DSA) in the evaluation of carotid artery stenosis. METHODS: A blinded comparison of first-pass contrast-enhanced MR angiography with conventional DSA was performed in 120 patients (240 arteries). MR angiography was performed with a 1.5-T magnet with gradient overdrive equipment, by using a coronal radiofrequency-spoiled 3D fast low-angle-shot sequence after the intravenous injection of gadodiamide. The guidelines of the North American Symptomatic Carotid Endarterectomy Trial for measuring stenosis of the internal carotid artery were applied on maximum intensity projection (MIP) images and conventional catheter angiograms. RESULTS: Grading of stenoses on MR angiograms agreed with grading of stenoses on DSA images in 89% of arteries. In the severe stenosis group (70-99%), agreement was 93%. All internal carotid occlusions (n = 28) and seven of nine pseudo-occlusions were accurately detected with contrast-enhanced MR angiography. The correlation between MR angiography and DSA for determination of minimal, moderate, and severe stenoses and occlusion was statistically significant (r = 0.91, P<.001). CONCLUSIONS: This investigation with a large number of patients confirms that contrast-enhanced MR angiography could become a diagnostic alternative to DSA in the treatment of patients with carotid artery disease.

Adolescent↗