Search PubMed⌕ Search

Biomedical subjects

Pamela M Norris

Publications and source records attributed to Pamela M Norris.

6 recordsLinked to original sources

Microchip-based macroporous silica sol-gel monolith for efficient isolation of DNA from clinical samples.

Effective microchip extraction of deoxyribonucleic acid (DNA) from crude biological matrixes has been demonstrated using silica beads or hybrid phases composed of beads and sol-gel. However, the use of monolithic sol-gels alone for extraction of human genomic DNA has been more difficult to define. Here we describe, for the first time, the successful use of monolithic tetramethyl orthosilicate-based sol-gels for effective micro-solid-phase extraction (muSPE) of DNA in a glass microchip format. A functional monolithic silica phase with micrometer-scale pores in the silica matrix resulted from addition of poly(ethylene glycol), a poragen, to the precursor mixture. This allowed a monolithic sol-gel bed to be established in a microchip channel that provided large surface area for DNA extraction with little flow-induced back pressure. DNA extraction efficiencies for simple systems (lambda-phage DNA) were approximately 85%, while efficiencies for the reproducible extraction of human genomic DNA from complex biological matrixes (human blood) were approximately 70%. Blockage of the sol-gel pores by components in the lysed blood was observed in repeat extraction on a single device as a decrease in the extraction efficiency. The developed muSPE protocol was further evaluated to show applicability to clinical samples and bacterial cultures, through extraction of PCR-amplifiable DNA.

DNA↗

A novel method for measuring dynamic changes in cell volume.

Many cell types regulate their volume in response to extracellular tonicity changes through a complex series of adaptive mechanisms. Several methods that are presently used to measure cell volume changes include Coulter counters, fluorescent techniques, electronic impedance, and video microscopy. Although these methods are widely used and accepted, there are limitations associated with each technique. This paper describes a new method to measure changes in cell volume based on the principle that fluid flow within a rigid system is well determined. For this study, cos-7 cells were plated to line the inner lumen of a glass capillary and stimulated to swell or shrink by altering the osmolarity of the perfusing solution. The cell capillary was connected in series with a blank reference capillary, and differential pressure changes across each tube were monitored. The advantages of this method include 1) ability to continuously monitor changes in volume during rapid solution changes, 2) independence from cell morphology, 3) presence of physiological conditions with cell surface contacts and cell-cell interactions, 4) no phototoxic effects such as those associated with fluorescent methods, and 5) ability to report from large populations of cells. With this method, we could detect the previously demonstrated enhanced volume regulation of cells overexpressing the membrane phosphoprotein phospholemman, which has been implicated in osmolyte transport.

Animals↗

Microchip-based purification of DNA from biological samples.

A microchip solid-phase extraction method for purification of DNA from biological samples, such as blood, is demonstrated. Silica beads were packed into glass microchips and the beads immobilized with sol-gel to provide a stable and reproducible solid phase onto which DNA could be adsorbed. Optimization of the DNA loading conditions established a higher DNA recovery at pH 6.1 than 7.6. This lower pH also allowed for the flow rate to be increased, resulting in a decrease in extraction time from 25 min to less than 15 min. Using this procedure, template genomic DNA from human whole blood was purified on the microchip platform with the only sample preparation being mixing of the blood with load buffer prior to loading on the microchip device. Comparison between the microchip SPE (microchipSPE) procedure and a commercial microcentrifuge method showed comparable amounts of PCR-amplifiable DNA could be isolated from cultures of Salmonella typhimurium. The greatest potential of the microchipSPE device was illustrated by purifying DNA from spores from the vaccine strain of Bacillus anthracis, where eventual integration of SPE, PCR, and separation on a single microdevice could potentially enable complete detection of the infectious agent in less than 30 min.

Adsorption↗

Towards a microchip-based chromatographic platform. Part 2: sol-gel phases modified with polyelectrolyte multilayers for capillary electrochromatography.

The potential for using polyelectrolyte multilayers (PEMs) to provide chromatographic functionality on continuous silica networks created from sol-gel chemistry has been evaluated by capillary electrochromatography (CEC). Construction of the PEM was achieved by flushing the column with polyelectrolytes of alternative charge, with variation of the properties of the exposed polyelectrolyte providing a unique means to vary the chromatographic surface. Variation of the exposed polyelectrolyte from poly(diallyldimethylammonium chloride) (PDDAC) to dextran sulfate (DS) allowed the direction of the electroosmotic flow (EOF) to be changed and also provided a means to vary the chromatographic capacity. Variation of negative polymer from DS to poly(styrene sulfonate) (PSS) significantly altered the EOF and the migration of peptides, with both the reversed-phase and ion-exchange capacities increasing. An alternative method for changing the column capacity was to change the thickness of the PEM, which was evaluated by anion-exchange CEC. A 70-80% increase in retention was observed for all anions without any increase in EOF suggesting significant penetration of the analytes through the PEM and interaction with buried charges within the PEM.

Dextran Sulfate↗

Toward a microchip-based solid-phase extraction method for isolation of nucleic acids.

A silica-based solid-phase extraction system suitable for incorporation into a microchip platform (nu-total analytical system; nu-TAS) would find utility in a variety of genetic analysis protocols, including DNA sequencing. The extraction procedure utilized is based on adsorption of the DNA onto bare silica. The procedure involves three steps: (i) DNA adsorption in the presence of a chaotropic salt, (ii) removal of contaminants with an alcohol/water solution, and (iii) elution of the adsorbed DNA in a small volume of buffer suitable for polymerase chain reaction (PCR) amplification. Multiple approaches for incorporation of this protocol into a microchip were examined with regard to extraction efficiency, reproducibility, stability, and the potential to provide PCR-amplifiable DNA. These included packing microchannels with silica beads only, generating a continuous silica network via sol-gel chemistry, and combinations of these. The optimal approach was found to involve immobilizing silica beads packed into the channel using a sol-gel network. This method allowed for successful extraction and elution of nanogram quantities of DNA in less than 25 min, with the DNA obtained in the elution buffer fraction. Evaluation of the eluted DNA indicated that it was of suitable quality for subsequent amplification by PCR.

DNA↗

Towards a microchip-based chromatographic platform. Part 1: Evaluation of sol-gel phases for capillary electrochromatography.

Silica monolithic columns suitable for implementation on microchips have been evaluated by ion-exchange capillary electrochromatography. Two different silica monoliths were created from the alkyl silane, tetramethyl orthosilicate (TMOS), by introducing a water-soluble organic polymer, poly(ethylene oxide) (PEO), with varying molecular weights into the prehydrolyzed sol. Silica monoliths created using 10 kDa PEO were found to have a much more closed gel structure with a smaller percentage of pores in the microm size range than gels created using 100 kDa PEO. Additionally, the size of the mesopores in the 100 kDa PEO monolith was 5 nm, while those in the 10 kDa PEO gel were only 3 nm. This resulted in a strong dependence of the electroosmotic flow (EOF) on the ionic strength of the background electrolyte, with substantial pore flow through the nm size pores observed in the 10 kDa PEO gel. The chromatographic performance of the monolithic columns was evaluated by ion-exchange electrochromatography, with ion-exchange sites introduced via dynamic coating with the cationic polymer, poly(diallyldimethylammonium chloride) (PDDAC). Separating a mixture of inorganic anions, the 10 kDa PEO monolithic columns showed a higher effective capacity than the 100 kDa PEO column.

Anions↗