Multidetector computed tomography for acute pulmonary embolism.

BACKGROUND: The accuracy of multidetector computed tomographic angiography (CTA) for the diagnosis of acute pulmonary embolism has not been determined conclusively. METHODS: The Prospective Investigation of Pulmonary Embolism Diagnosis II trial was a prospective, multicenter investigation of the accuracy of multidetector CTA alone and combined with venous-phase imaging (CTA-CTV) for the diagnosis of acute pulmonary embolism. We used a composite reference test to confirm or rule out the diagnosis of pulmonary embolism. RESULTS: Among 824 patients with a reference diagnosis and a completed CT study, CTA was inconclusive in 51 because of poor image quality. Excluding such inconclusive studies, the sensitivity of CTA was 83 percent and the specificity was 96 percent. Positive predictive values were 96 percent with a concordantly high or low probability on clinical assessment, 92 percent with an intermediate probability on clinical assessment, and nondiagnostic if clinical probability was discordant. CTA-CTV was inconclusive in 87 of 824 patients because the image quality of either CTA or CTV was poor. The sensitivity of CTA-CTV for pulmonary embolism was 90 percent, and specificity was 95 percent. CTA-CTV was also nondiagnostic with a discordant clinical probability. CONCLUSIONS: In patients with suspected pulmonary embolism, multidetector CTA-CTV has a higher diagnostic sensitivity than does CTA alone, with similar specificity. The predictive value of either CTA or CTA-CTV is high with a concordant clinical assessment, but additional testing is necessary when the clinical probability is inconsistent with the imaging results.

Acute Disease↗

Diagnostic pathways in acute pulmonary embolism: recommendations of the PIOPED II investigators.

PURPOSE: To formulate comprehensive recommendations for the diagnostic approach to patients with suspected pulmonary embolism, based on randomized trials. METHODS: Diagnostic management recommendations were formulated based on results of the Prospective Investigation of Pulmonary Embolism Diagnosis II (PIOPED II) and outcome studies. RESULTS: The PIOPED II investigators recommend stratification of all patients with suspected pulmonary embolism according to an objective clinical probability assessment. D-dimer should be measured by the quantitative rapid enzyme-linked immunosorbent assay (ELISA), and the combination of a negative D-dimer with a low or moderate clinical probability can safely exclude pulmonary embolism in many patients. If pulmonary embolism is not excluded, contrast-enhanced computed tomographic pulmonary angiography (CT angiography) in combination with venous phase imaging (CT venography), is recommended by most PIOPED II investigators, although CT angiography plus clinical assessment is an option. In pregnant women, ventilation/perfusion scans are recommended by many as the first imaging test following D-dimer and perhaps venous ultrasound. In patients with discordant findings of clinical assessment and CT angiograms or CT angiogram/CT venogram, further evaluation may be necessary. CONCLUSION: The sequence for diagnostic test in patients with suspected pulmonary embolism depends on the clinical circumstances.

Acute Disease↗

Non-coronary cardiac CT imaging.

Cardiac multidetector CT (MDCT) has moved from purely anatomic imaging, to assessment of cardiac function. Significant advances since the advent of multidetector CT now make it feasible to assess not only the coronary arteries, but also ejection fraction, ventricular volumes, myocardial mass and the presence of wall-motion abnormalities. Advances include improvements in EKG-gating, including improvements in temporal resolution, as well as the addition of delayed contrast-enhanced methods. Anatomic imaging has improved as well, with thinner collimation and better reconstruction methods. Three-dimensional software programs now permit excellent surface rendered displays and multiplanar reconstructions suitable as surgical and procedural "road maps."

Heart Diseases↗

CT depiction of pulmonary emboli: display window settings.

PURPOSE: To compare computed tomographic (CT) window settings selected by radiologists with those determined by using two alternative approaches for depiction of pulmonary emboli (PE). MATERIALS AND METHODS: Institutional review board approval was obtained; informed consent was not required. This study was compliant with the Health Insurance Portability and Accountability Act. Twenty-five clinical chest CT studies were obtained with a standardized PE protocol and retrospectively evaluated by five chest and two body CT radiologists. Of these studies, 13 were positive for PE, and 12 were negative. At the main pulmonary artery (PA), mean attenuations (MPA) and standard deviations (SDPA) were measured. Initially, images were displayed with a standard mediastinal window setting (window width, W = 400 HU; window center, C = 30 HU), and each observer adjusted the setting to a personally preferred setting (eg, "personal") for PE detection. Images displayed at this setting were compared in a side-by-side fashion with the "modified" (W = MPA + 2 . SDPA, C = W/2) and "double-half" (W = 2 . MPA, C = MPA/2) window setting. Each observer rated images from 1 (ie, most preferred) to 3 (ie, least preferred). For quantitative analysis, window width and center value of each setting were divided by corresponding MPA to compute a width ratio and a center ratio. Window settings and ratings were compared with repeated-measures analysis of variance, paired t tests, and Wilcoxon signed-rank tests. RESULTS: Ratings for all three types of window settings were significantly different (P < .001). Observers preferred their personal settings the most and the modified settings the least. Mean ratios for the seven observers were 1.68 +/- 0.20 for window width and 0.47 +/- 0.08 for window center. Window width ratios for all settings were significantly different from each other (P < .001). Window center ratios were significantly higher for the modified setting than for the double-half setting (P = .013). Values for mean PA attenuation were correlated with window width ratios for six (86%) observers (mean r2 value = 0.29 +/- 0.19, P < or = .03) and with window center ratios for four (57%) observers (mean r2 value = 0.16 +/- 0.14, P < or = .02), thus indicating a trend of setting window width and window center higher when contrast enhancement is lower and vice versa. CONCLUSION: On average, observers selected CT window settings for PE detection at a window width of slightly less than twice the mean PA attenuation and at a window center of about half the mean PA attenuation. Observers tended to use larger window widths and centers as the degree of PA enhancement was lower.

Adult↗

Accurate myocardial T1 measurements: toward quantification of myocardial blood flow with arterial spin labeling.

In this study, we investigated a method for accurately measuring myocardial T(1) for the quantification of myocardial blood flow (MBF) with arterial spin labeling (ASL). A single-shot gradient-echo (GE)-based ASL sequence with an adiabatic hyperbolic secant inversion recovery pulse was modified to acquire a pair of myocardial T(1)'s within a breath-hold. A multivariable regression algorithm that accounted for the magnetization saturation effects was developed to calculate T(1). The MBF was then determined with a well-developed model. The accuracy of our T(1) calculation was first evaluated in a phantom, and then in six dogs for the MBF calculation, with (N = 4) and without (N = 2) coronary artery stenosis. In the phantom study, the accuracy of T(1) measured with a slice-selective inversion prepared pulse was within 2.5% of error. In healthy dogs, the MBF increased 2-5 times during vasodilation. In contrast, regional differences of MBF were well visualized in the stenotic dogs during vasodilation (perfusion reserve of 2.75 +/- 0.83 in normal myocardium, and 1.46 +/- 0.75 in the stenotic area). A correlation analysis revealed a close agreement in MBF between the ASL and microsphere (MS) in both healthy and stenotic dogs. In summary, the modified ASL technique and T(1) regression algorithm proposed here provide an accurate measurement of myocardial T(1) and demonstrate potential for reliably assessing MBF at steady state.

Algorithms↗

Quantitative assessment of coronary artery plaque vulnerability by high-resolution magnetic resonance imaging and computational biomechanics: a pilot study ex vivo.

The risk of atherosclerotic plaque disruption is thought to be closely related to plaque composition and rupture triggers such as external mechanical forces. The purpose of this study was to integrate MR imaging and computational techniques for the quantification of plaque vulnerability with morphologic data and biomechanical stress/strain distributions that were all based on high-resolution MR images of coronary artery plaque specimens ex vivo. Twenty-two coronary artery plaque specimens were selectively collected from 10 cadavers. Multislice T(2)-weighted spin echo images were acquired with a resolution of 100 x 100 microm(2). Histopathological images were used as the gold standard for the identification of plaque components and vulnerability. Plaque components were classified on MR images, and the stress/strain components were calculated with a two-dimensional computational model with fluid-structure interactions. As expected, vulnerable plaques appeared to result from a large lipid pool, a thin fibrous cap, and some critical stress/strain conditions. An empiric vulnerability marker was derived and was closely related to the vulnerability score that was determined through pathologic examination. Noninvasive quantification of the MR contrast and mechanical properties of plaque may provide a comprehensive biomarker for the assessment of vulnerability of atherosclerotic plaques.

Biomechanical Phenomena↗

Local maximal stress hypothesis and computational plaque vulnerability index for atherosclerotic plaque assessment.

It is believed that atherosclerotic plaque rupture may be related to maximal stress conditions in the plaque. More careful examination of stress distributions in plaques reveals that it may be the local stress/strain behaviors at critical sites such as very thin plaque cap and locations with plaque cap weakness that are more closely related to plaque rupture risk. A "local maximal stress hypothesis" and a stress-based computational plaque vulnerability index (CPVI) are proposed to assess plaque vulnerability. A critical site selection (CSS) method is proposed to identify critical sites in the plaque and critical stress conditions which are be used to determine CPVI values. Our initial results based on 34 2D MRI slices from 14 human coronary plaque samples indicate that CPVI plaque assessment has an 85% agreement rate (91% if the square root of stress values is used) with assessment given by histopathological analysis. Large-scale and long-term patient studies are needed to further validate our findings for more accurate quantitative plaque vulnerability assessment.

Coronary Artery Disease↗

Feasibility of combining MR perfusion, angiography, and 3He ventilation imaging for evaluation of lung function in a porcine model.

RATIONALE AND OBJECTIVE: To assess the feasibility of combining magnetic resonance (MR) perfusion, angiography, and 3He ventilation imaging for the evaluation of lung function in a porcine model. MATERIALS AND METHODS: Fourteen consecutive porcine models with externally delivered pulmonary emboli and/or airway occlusions were examined with MR perfusion, angiography, and 3He ventilation imaging. Ultrafast gradient-echo sequences were used for 3D perfusion and angiographic imaging, in conjunction with the use of contrast-agent injections. 2D multiple-section 3He imaging was performed subsequently via the inhalation of hyperpolarized 3He gas. The diagnostic accuracy of MR angiography for detecting pulmonary emboli was determined by two reviewers. The diagnostic confidence for different combinations of MR techniques was rated on the basis of a 5-point grading scale (5 = definite). RESULTS: The sensitivity, specificity, and accuracy of MR angiography for detecting pulmonary emboli were approximately 85.7%, 90.5%, and 88.1%, respectively. The interobserver agreement was very strong (k = 0.82). There was a clear tendency for confidence to increase when first perfusion and then ventilation imaging were added to the angiographic image (Wilcoxon signed ranks test, P = 0.03). CONCLUSION: The combination of the three methods of MR perfusion, angiography, and 3H ventilation imaging may provide complementary information on abnormal lung anatomy and function.

Administration, Inhalation↗

Quantifying effects of plaque structure and material properties on stress distributions in human atherosclerotic plaques using 3D FSI models.

BACKGROUND: Atherosclerotic plaques may rupture without warning and cause acute cardiovascular syndromes such as heart attack and stroke. Methods to assess plaque vulnerability noninvasively and predict possible plaque rupture are urgently needed. METHOD: MRI-based three-dimensional unsteady models for human atherosclerotic plaques with multi-component plaque structure and fluid-structure interactions are introduced to perform mechanical analysis for human atherosclerotic plaques. RESULTS: Stress variations on critical sites such as a thin cap in the plaque can be 300% higher than that at other normal sites. Large calcification block considerably changes stress/strain distributions. Stiffness variations of plaque components (50% reduction or 100% increase) may affect maximal stress values by 20-50%. Plaque cap erosion causes almost no change on maximal stress level at the cap, but leads to 50% increase in maximal strain value. CONCLUSIONS: Effects caused by atherosclerotic plaque structure, cap thickness and erosion, material properties, and pulsating pressure conditions on stress/strain distributions in the plaque are quantified by extensive computational case studies and parameter evaluations. Computational mechanical analysis has good potential to improve accuracy of plaque vulnerability assessment.

Blood Pressure↗

Coronary artery stent patency assessed with in-stent contrast enhancement measured at multi-detector row CT angiography: initial experience.

The authors investigated the contrast enhancement characteristics of the coronary artery stent lumen to assess patency and then evaluated the accuracy of computed tomographic (CT) measurement of the in-stent luminal diameter. Nineteen patients (16 men and three women; mean age, 58.7 years) with 26 stents underwent cardiac-gated CT angiography with a 16-detector row scanner 1-3 weeks after stent placement. CT images depicted the lumina of 20 stents in 14 patients. CT attenuation measured in the treated lumen was higher than, and correlated highly (r >/= 0.87) with, attenuation in the proximal and distal untreated lumen. Estimated values for in-stent luminal diameter were lower with CT than with conventional angiography (P <.001), and the mean error (16.1%) that resulted from estimation based on sharp-kernel CT images was significantly smaller than that (27.3%) from estimation based on medium-smooth-kernel CT images (P <.001). Visualization of the in-stent lumen at CT angiography with a 16-detector row scanner allows assessment of coronary artery stent patency on the basis of measured contrast enhancement.

Adult↗

Magnetic resonance imaging-guided coronary interventions.

Magnetic resonance imaging (MRI) guidance for coronary interventions offers potential advantages over conventional x-ray angiography. Advantages include the use of nonionizing radiation, combined assessment of anatomy and function, and three-dimensional assessment of the coronary arteries leading to the myocardium. These advantages have prompted a series of recent studies in this field. Real-time coronary MR angiography, with low-dose catheter-directed intraarterial (IA) infusion of contrast media, has achieved in-plane spatial resolution as low as 0.8 x 0.8 mm2 and temporal resolution as short as 130 msec per image. Catheter-based IA injection of contrast agent has proven useful in the collection of multislice and three-dimensional images, not only for coronary intervention guidance, but also in the assessment of regional myocardial perfusion fed by the affected vessel. Actively visible guidewires and guiding catheters, based on the loopless antenna concept, have been effectively used to negotiate tortuous coronary vessels during catheterization, permitting placement of coronary angioplasty balloon catheters. Passive tracking approaches have been used to image contrast agent-filled coronary catheters and to place susceptibility-based endovascular stents. Although the field is in its infancy, these early results demonstrate the feasibility for performing MRI-guided coronary interventions. Although further methodological and technical developments are required before these methods become clinically applicable, we anticipate that MRI someday will be included in the armamentarium of techniques used to diagnose and treat coronary artery disease.

Contrast Media↗

Relationship of apparent myocardial T2 and oxygenation: towards quantification of myocardial oxygen extraction fraction.

PURPOSE: To explore the relationship of myocardial T(2) and oxygenation for the quantification of myocardial oxygen extraction fraction (OEF). MATERIALS AND METHODS: A proposed myocardial T(2)-OEF relationship was evaluated by computer simulation and in nine normal dogs in vivo. The relationship was based on a simplified two-compartment T(2) model. In the dogs, dipyridamole was infused intravenously to increase blood flow and change in myocardial oxygen content. The accuracy of the measurement in myocardial OEF in vivo by magnetic resonance imaging (MRI) was determined by arterial and coronary sinus blood sampling. RESULTS: Global myocardial T(2) increased 16.1% from rest to the peak of dipyridamole-induced vasodilation (44.6 +/- 2.1 msec vs. 51.4 +/- 2.1 msec, P < 0.001). Corresponding OEF measured by arterial and venous (AV) sampling decreased from 0.64 +/- 0.15 at rest to 0.18 +/- 0.08 during the dipyridamole vasodilation, whereas OEF calculated by MRI at the peak effect of dipyridamole was 20 +/- 4%. Global myocardial OEF measured dynamically by MRI showed a strong correlation with OEF measured by blood sampling (correlation coefficient (CC) = 0.83) during pharmacologic vasodilation. CONCLUSION: When combined with vasodilator stress, assessment of OEF may provide a putative measure of myocardial flow reserve, allowing consecutive monitoring of myocardial dose-responses to a variety of interventions and offering a new tool for the detection of coronary artery disease.

Animals↗

Dynamic estimation of the myocardial oxygen extraction ratio during dipyridamole stress by MRI: a preliminary study in canines.

The myocardial oxygen extraction fraction (OEF) reflects the balance between myocardial oxygen supply and demand. The feasibility of quantifying myocardial OEF was demonstrated with MRI during pharmacologic vasodilation in dogs. Dipyridamole was infused intravenously to increase blood flow and change in myocardial oxygen content. Arterial and coronary sinus blood sampling was performed during dipyridamole-induced vasodilation to measure the myocardial blood oxygen content. Myocardial T(2) was measured dynamically during the vasodilation, and quantified with a simplified diffusion model as a function of myocardial OEF and blood volume. The results showed a strong correlation (R(2) = 0.89) between myocardial OEF values measured by MRI and those measured by blood sampling. Regional differences in the OEF were demonstrated by direct infusion of dipyridamole into coronary arteries in dogs. Combined with vasodilator stress, dynamic assessments of the OEF may provide a putative measurement of myocardial flow reserve and allow consecutive monitoring of myocardial dose and response.

Animals↗

How to plan and perform a cardiac MR imaging examination.

Because of the enormous economic and social impact of cardiovascular disease in the United States there is a need for improved noninvasive diagnosis. Cardiac MR imaging isa versatile, comprehensive technique for assessing cardiac morphology and function. With an understanding of cardiac anatomy and physiology and MR imaging physical principles,cardiac MR imaging can be performed and can play an important role in patient management. This article provides the reader with a basic understanding of cardiac MR imaging and the practical applications required to perform cardiac MR imaging.

Cardiovascular Diseases↗