Search PubMed⌕ Search

Biomedical subjects

P Zilla

Publications and source records attributed to P Zilla.

At least 37 records · Page 2Linked to original sources

Tissue adhesives in cardiovascular surgery.

Tissue adhesives are increasingly being used in cardiovascular surgery as adjuncts to obtain more rapid hemostasis, as tissue reinforcing agents, as carriers for prolonged local release of antibiotics, to spatially fix long saphenous vein grafts that could otherwise possibly kink, and to promote endothelialization of prosthetic graft surfaces. The available tissue adhesives, their current indications for use, and possible future trends are discussed.

Blood Banks↗

In vitro endothelialization of expanded polytetrafluoroethylene grafts: a clinical case report after 41 months of implantation.

PURPOSE: Forty-one months after we performed bilateral implantation of in vitro endothelialized femoropopliteal bypass grafts in a 69-year-old patient, we obtained a central graft segment for histologic and ultrastructural investigation. METHODS: Before implantation the grafts were confluently lined with autologous first passage mass cultures of pure cephalic vein endothelial cells. The precoating of the expanded polytetrafluoroethylene prosthesis was done with fibrinolytically inhibited fibrin glue. Reoperation became necessary because of symptomatic unilateral atherosclerotic lesions located in the center of one of the two in vitro lined grafts. A 21 cm long graft segment was removed and replaced by a new in vitro endothelialized expanded polytetrafluoroethylene graft. RESULTS: On scanning electron microscopy a confluently covering mature endothelium was found throughout the whole length of the removed prosthesis. The endothelial identity was confirmed by a positive immunohistochemical CD 34, von Willebrand factor-staining, and the ultrastructural demonstration of Weibel Pallade bodies. The endothelium rested on a collagen IV positive basement membrane. Histologic cross sections revealed uniformly developed subintimal tissue of 1.21 +/- 0.19 mm thickness, which was separated from the intima by a distinct internal elastic membrane. The cells of this cell-rich matrix stained strongly positive for actin. Ultrastructurally, this matrix was dominated by highly contractile myofibroblasts loaded with peripherally located well-developed actin fillaments. A number of these cells also showed signs of secretory cells with a distinct endoplasmic reticulum and a Golgi complex. In areas of atherosclerotic lesions the subendothelial matrix was partially exposed, and the internal elastic membrane had to a certain extent disintegrated. Only in these areas KP-1 and MG-M1 positive foamy macrophages and CD 34 positive capillaries were found. The myofibroblasts of this diseased part of the subintimal tissue contained large lipid vacuoles. CONCLUSIONS: We conclude that the confluent in vitro lining of synthetic vascular grafts with pure autologous endothelial cells facilitates graft healing, which may result in a hybrid structure with features of a native vessel.

Actins↗

Improved ultrastructural preservation of bioprosthetic tissue.

BACKGROUND AND AIMS OF THE STUDY: Poor ultrastructural tissue preservation of bioprosthetic heart valves is associated with a higher propensity for calcification. In spite of this realization, commercial valve fixation remains suboptimal. METHODS: In an attempt to maintain tissue integrity through improved cross-linking procedures, transmission electron microscopy and a 21-point damage score were applied to assess the ultrastructural preservation of aortic wall tissue-the main component of contemporary aortic valve bioprostheses. An ideal glutaraldehyde (GA) concentration was assessed by immediate tissue fixation at 4 degrees C comparing 0.2%, 0.5%, 0.65%, 1.0%, 2.0%, 3.0% and 4.0% GA in phosphate-buffered saline (PBS). Subsequently, an optimal concentration of 3.0% GA was used to determine the effect of fixation temperature (4 degrees, 22 degrees and 37 degrees C). Finally, the superior glutaraldehyde concentration (3.0%) and cross-linking temperature (4 degrees C) were used to assess tolerance towards delayed fixation. RESULTS: When different GA concentrations were used almost identical damage scores of 6.3 and 5.8 were found for 0.2% and 0.65% fixation. The first significant improvement was found at a concentration of 1.0% (score 3.3; p < 0.01) followed by a further improvement at 3.0% (score 2.6; p = 0.05). The optimal fixation temperature was 4 degrees C (3.7) with the worst results obtained at room temperature (score 9.2; p < 0.03). When fixation was delayed, the most significant damage occurred during the initial 30 min after slaughter (from 2.3 to 7.4; p < 0.02) followed by another significant deterioration between 4 and 16 h (from 5.6 to 9.7; p < 0.02). CONCLUSIONS: In summary, the prerequisites for an ideal ultrastructural preservation of bioprosthetic aortic wall tissue are immediate fixation (within 30 min), high GA concentrations (> 1.0%) and cold-temperature fixation (4 degrees C).

Animals↗

High glutaraldehyde concentrations reduce rather than increase the calcification of aortic wall tissue.

BACKGROUND AND AIMS OF THE STUDY: This study was performed in order to: (i) determine whether a similar reduction of tissue calcification as seen after prolonged storage can be achieved through higher concentrations of glutaraldehyde (GA); and (ii) verify that well-preserved tissue integrity can suppress calcification. METHODS: Before fixation in 0.2% GA (PBS, 4 degrees C, seven days) porcine aortas were kept on ice for 48 h. Alternatively, tissue was immediately fixed at the abattoir in 0.2%, 1.0% or 3% glutaraldehyde (PBS, 4 degrees C, seven days). A second group of immediately fixed tissue (0.2%, 1.0%, 3.0% GA) (PBS, 4 degrees C, two days) had an interim step of L-lysine treatment (0.1M, 37 degrees C, acetic acid buffer, two days) in order to enhance cross-linking followed by warm-temperature fixation (PBS, 37 degrees C, five days). Two animal models were compared: subcutaneous implantation in rats (12 weeks) and vascular implantation in non-human primates, Chacma baboons (six weeks). RESULTS: In both animal models the highest level of calcification was found in the group with delayed fixation in 0.2% GA. In the rat model there was an inverse correlation between tissue calcification and the GA concentration used, with 3% GA-fixed tissue showing the lowest level of tissue calcium. Overall, increasing GA concentration had a significant benefit on calcification (p < 0.0001; two-factor analysis of variance). Enhancement of cross-linking with L-lysine further abrogated tissue calcium levels at all GA concentrations (p < 0.0001; two- factor analysis of variance). Although the short-term baboon model showed lower tissue calcium levels, the trend seen in the rat model was confirmed. CONCLUSIONS: Our results demonstrate the detrimental effect of delayed fixation and further suggest that, against previous beliefs, fixation at higher glutaraldehyde concentrations reduces the calcification tendency of cross-linked aortic tissue.

Abdominal Muscles↗

Glutaraldehyde detoxification of aortic wall tissue: a promising perspective for emerging bioprosthetic valve concepts.

BACKGROUND AND AIMS OF THE STUDY: Due to its superb crosslinking activity, glutaraldehyde (GA) is still the most widely used fixative for bioprosthetic heart valves. At the same time, however, GA is also believed to be partly responsible for tissue calcification and the lack of surface re-endothelialization, both of which may contribute to valve degeneration. Although excess GA has previously been extracted from thin leaflet tissue, this treatment proved insufficient for the detoxification of thick aortic wall tissue of stentless valves or root prostheses. METHODS: In order to establish a detoxification procedure which thoroughly extracts biologically active GA from aortic wall tissue, we used a highly sensitive bioassay where endothelial cells were seeded onto glutaraldehyde-fixed aortic wall discs following various detoxification procedures. Absolute cell numbers and morphologic shape were correlated with shrinkage temperature and shrinkage extent of the tissue to determine the potential of the treatments to reverse crosslinks. To optimize treatment conditions, pH (3.2 versus 4.5), temperature (22 degrees C versus 37 degrees C) and incubation time (48 h versus one week) were varied. In order to identify an optimal detoxification agent, 12 different amino-reagents from four chemical groups were compared: low pKa aromatic amines, amino acids, low pKa N-heterocyclic compounds and amino sugars. RESULTS: Amino-reagent treatment required warm temperature (37 degrees C), prolonged reaction time (one week) and a pH of 4.5 to achieve long-term cell growth on glutaraldehyde-fixed aortic wall. All 12 amino-reagents were able to detoxify aortic tissue satisfactorily; and all mildly reversed crosslinks, although there were differences between candidates. When summarized data were ranked correlating cell growth and quality with shrinkage temperature and shrinkage extent, seven reagents had a rank sum above the overall mean value, and five below with statistically significant differences between candidates. The additional stabilization of the detoxification reaction through borohydride-reduction had no further effect on tissue biocompatibility and crosslinks. CONCLUSIONS: Efficient detoxification of thick aortic wall tissue is possible if a one-week incubation in an acetic acid buffer-based amino-reagent is carried out at 37 degrees C.

Acetic Acid↗

Syphilitic aortic aneurysm eroding through the sternum.

Syphilitic aortic aneurysms are uncommon today. A syphilitic aneurysm eroding through the anterior chest wall with successful surgical treatment is reported. The large size these aneurysms reach, in conjunction with the overlying pressure-induced skin necrosis necrosis can represent a technical challenge to the surgeon, both in the method of repairing the aneurysm as well as reconstructing the chest wall. Syphilitic aortic disease is also briefly reviewed.

Anastomosis, Surgical↗

Acute traumatic rupture of the thoracic aorta. A comparison of techniques.

Twenty-eight patients were treated for acute blunt thoracic aortic rupture at Groote Schuur Hospital between January 1984 and March 1994. Aortic arch ruptures occurred in 2 patients and were successfully repaired by means of hypothermic circulatory arrest. Descending aortic ruptures were repaired more safely by insertion of an interposition graft as opposed to direct suture reapproximation, and with the aid of partial heparinless bypass as opposed to simple aortic cross-clamping.

Accidents, Traffic↗

Aortic dissection repair with GRF glue complicated by heart block.

Gelatin-resorcin-formaldehyde-glutaraldehyde (GRF) biologic glue is an available adjunct to repair acute ascending aortic dissections. Permanent complete heart block complicated the operative repair of 2 of 6 patients. The pathophysiology of heart block resulting from either the acute dissecting process or the technique of applying GRF glue is discussed.

Acute Disease↗

Traumatic aortic rupture: twenty-year metaanalysis of mortality and risk of paraplegia.

A metaanalysis of articles concerning the surgical management of acute traumatic rupture of the descending thoracic aorta published in the English-language literature between 1972 and July 1992 was performed. The overall mortality of 1,742 patients who arrived at the hospital alive was 32.0%, one-third died before surgical repair was started. Paraplegia was noted preoperatively in 2.6% of these hospitalized patients, and paraplegia complicated the surgical repair in 9.9% of 1,492 patients who reached the operating room in a relatively stable condition. Patients then were analyzed according to the surgical intervention used. Simple aortic cross-clamping (n = 443) was associated with a hospital mortality of 16.0% and incidence of paraplegia of 19.2%, despite lower average mean cross-clamp times (32 minutes; p < 0.01 versus passive or active methods of providing distal perfusion). In a subset of 290 patients in whom individual data were available, the cumulative risk of paraplegia was shown to increase substantially if the duration of aortic cross-clamping exceeded 30 minutes, but only when distal perfusion was not augmented (p < 0.00001). "Passive" perfusion shunts (n = 424) were associated with a mortality of 12.3%, and the incidence of paraplegia decreased to 11.1% (p < 0.001). However, shunts inserted from the apex of the left ventricle had a contradictory high 26.1% incidence of paraplegia compared with shunts from the ascending aorta (8.2%; p < 0.02).(ABSTRACT TRUNCATED AT 250 WORDS)

Acute Disease↗

Clinical in vitro endothelialization of femoropopliteal bypass grafts: an actuarial follow-up over three years.

PURPOSE: The creation of an endothelial coverage on prosthetic vascular surfaces may improve the performance of synthetic small diameter vascular grafts. In vitro lining with cultured autologous endothelial cells offers a confluent endothelium at the time of implantation. METHODS: Between June 1989 and December 1991, 49 patients who had no saphenous vein available entered the study. Indication for operation was disabling claudication in 37 patients and critical ischemia in 12 patients. With a random 1:2 assignment, 33 patients were admitted to the endothelialized group and 16 control patients received an untreated polytetrafluoroethylene prosthesis. Cultured autologous endothelial cells from the external jugular vein were confluently lined onto polytetrafluoroethylene grafts precoated with fibrinolytically inhibited fibrin glue. The follow-up was based on angiography, platelet labeling studies with indium 111-labeled oxine, assessment of the ankle-brachial index, and duplex sonography. RESULTS: First-passage mass cultures of 16 million endothelial cells-required for the confluent lining of a 70 cm long 6 mm graft-were reached 25.1 +/- 11.2 days after vein excision. Growth failure occurred in 27.3%. After 32 months, the actuarial patency was 84.7% for endothelialized grafts and 55.4% for control grafts (p < 0.041 by Breslow test; p < 0.068 by Mantel-Cox test). The ankle-brachial index was continually diverging, reaching significantly lower values in the control group at 24 months (0.98 +/- 0.14 in the endothelialized group versus 0.70 +/- 0.12 in the control; p < 0.0023). The uptake of indium 111-labeled platelets--measured at 9 days, 3 months, 6 months, and 12 months--was significantly lower in the endothelialized group during the entire observation period.

Actuarial Analysis↗

In vitro endothelialization of a mesosystemic shunt: a clinical case report.

The existence of a confluently covering endothelium that is free of any thrombotic appositions can be proved 30 days after clinical implantation of an in vitro endothelialized expanded polytetrafluoroethylene graft. The recipient of the mesosystemic H-graft was a 69-year-old man who had a thrombosed portal vein following pancreatitis. Autologous endothelial cells were obtained from the external jugular vein under local anesthesia, applying the in situ cannulation technique. After low-density plating, first-passage mass cultures of 1.22 x 10(6) endothelial cells were obtained 14 days after vein excision. After precoating was accomplished with fibrinolytically inhibited fibrin glue, a 10 mm expanded polytetrafluoroethylene graft was confluently lined with the autologous endothelial cells at a seeding density of 1.2 x 10(5) cells/cm2. After a maturation period of an additional 9 days and the microbiologic exclusion of a possible infection, an 11 cm graft segment was implanted between the superior mesenteric vein and the inferior vena cava. In spite of a patent shunt the patient had a repeat bleeding episode, needed parenteral nutrition, and died of sepsis on day 30. Immediately after the graft had been taken out, specimens were processed by scanning electron microscopy and light microscopy for the immunohistochemical proof of the endothelial nature of the surface-covering cell layer. The entire graft surface displayed a confluent cell lining that was free of any thrombotic appositions. A strongly positive stain result for both factor VIII-related antigen and the fixation-resistant CD34 molecule identified these cells as endothelial. No alpha-actin-positive cells could be detected. The underlying protein matrix was well preserved and unaltered in thickness and appearance, compared with preimplantation samples. None of the specimens showed any evidence of infection. This human demonstration of an intact endothelium on a patent venous prosthesis further establishes in vitro lining as a method that actually creates a persistent and functioning endothelium on a synthetic graft surface.

Aged↗

Spinal cord protection in the absence of collateral circulation: meta-analysis of mortality and paraplegia.

A meta-analysis of paraplegia complicating aortic surgery on patients having neither intercostal nor spinal collaterals, epitomized by patients with acute traumatic aortic rupture, was done. Index Medicus and Medline were searched for all suitable English publications between 1972 and 1992. New paraplegia occurred in 9.9% of 1492 patients who underwent surgery. However, 19.2% of patients undergoing surgery with only simple aortic cross-clamping developed paraplegia, in contrast to 6.1% if distal aortic perfusion was augmented by either "passive" or "active" methods (p < 0.00001). The risk of paraplegia increased progressively as cross-clamp times lengthened if simple aortic cross-clamping was used (p < 0.00001), but only once did the cross-clamp time exceed 30 minutes (p < 0.05). Paraplegia occurred in 8.2% of patients with "passive" shunts from the ascending aorta (p < 0.001 vs simple cross-clamping). Shunts from the left ventricular apex, however, had an incidence of paraplegia of 26.1% and, therefore, did not decrease the risk of paraplegia. "Active" augmentation of distal perfusion had the lowest risk of paraplegia: 2.3% (p < 0.00001 vs simple cross-clamping or "passive" shunts). Mortality, however, was higher in these potentially polytraumatized patients when they were perfused distally using methods requiring full systemic heparinization (18.2%), compared to mortality with methods not requiring heparin (11.9%; p < 0.01). In conclusion, simple aortic cross-clamping has a high risk of paraplegia if the cross-clamp time extends beyond 30 minutes. "Active" modalities of augmenting distal perfusion provide optimal spinal protection.

Aorta, Thoracic↗

In vitro-lined endothelium: initial integrity and ultrastructural events.

BACKGROUND: The early fate of in vitro-endothelialized prosthetic vascular grafts was assessed in the nonhuman primate. METHODS: Each of 17 male chacma baboons received a control and a confluently endothelialized 4 mm polytetrafluoroethylene graft in femoro-femoral positions (8.2 +/- 0.8 cm). All experimental grafts were precoated with fibrinolytically inhibited fibrin glue and lined with cultured autologous endothelial cells (EC) from the external jugular vein. The average time period needed to obtain first-passage mass-cultures sufficient for preconfluent graft endothelialization was 19.8 +/- 5.2 days. Before implantation in vitro-lined grafts were kept in culture for another 16.1 +/- 4.3 days to achieve complete confluence and maturation of the EC cytoskeleton. RESULTS: After 9 days of implantation, endothelial-lined grafts still showed a confluent endothelium that was free of any fibrin deposits. However, the EC density was significantly lower than at implantation (39.7 +/- 7.6 x 10(3) versus 59.9 +/- 8.5 x 10(3) EC/cm2; p < 0.05), and occasional 10-microns-wide intercellular gaps with adherent platelets and leukocytes were visible. Transmission electron microscopy showed leukocytes and cell debris in the underlying fibrin glue. After 4 weeks of implantation, the endothelium of experimental prostheses had regained a high cell density (72.7 +/- 10.5 x 10(3) EC/cm2) with a mature and well-differentiated morphologic appearance. At both observation periods, the surface of control grafts showed a wide range from fibrin deposits to an amorphous protein coverage containing spread platelets. CONCLUSIONS: The endothelium of in vitro-endothelialized vascular prostheses remains confluent after implantation and is nonthrombogenic in spite of a moderate initial cell loss.

Animals↗

Immediate shear stress resistance of endothelial cell monolayers seeded in vitro on fibrin glue-coated ePTFE prostheses.

The shear stress resistance of endothelial cells (EC) previously seeded onto ePTFE grafts was assessed by morphometric determination of the number of cells per cm2 of graft surface before and after exposure of 6 h of arterial blood flow interposed in the canine femoral artery. Autologous venous endothelial cells (AVEC) were harvested from the extrajugular veins of five dogs. The AVEC were cultured in vitro and seeded at a density of 150 x 10(3) cells per cm2 onto 4 mm ID ePTFE grafts precoated with fibrin glue and human fibronectin. Subsequently, the AVEC monolayers on the grafts were cultured for 8 days using a perfusion system and then implanted end-to-end in the femoral artery. All grafts remained patent (5/5). Scanning electron microscopy demonstrated complete, thrombus-free monolayers of AVEC after 6 h of arterial blood flow. The cell densities were 124 +/- 14 and 129 +/- 7 x 10(3) cells per cm2 respectively before and after implantation. It is concluded that in vitro lining of 4 mm ePTFE vascular prostheses is feasible and results in EC monolayers on the graft surface which are shear stress resistant and athrombogenic.

Animals↗

The endothelium: a key to the future.

The vascular endothelium is a complex modulator of a variety of biological systems and may well be the key to definitive success in the treatment of cardiovascular disorders. Surgically-induced endothelial injury may occur preoperatively during cardiac catheterization and intraoperatively from mechanical manipulation, ischemia, hypothermia, and exposure to cardioplegic solutions. The normal endothelium is antithrombogenic and yet promotes platelet aggregation and coagulation if injured. Vasospasm, occlusive intimal hyperplasia, and accelerated arteriosclerosis can also all occur as a result of endothelial injury. Furthermore, endothelial injury is harmful even in the absence of disruption of its monolayer integrity. Thus, preservation of the endothelium should be an additional objective for all cardiovascular surgeons. Synthetic vascular grafts, cardiac valves, and artificial ventricles do not spontaneously endothelialize and thus usually require some form of anticoagulation to maintain patency. Hence, endothelialization of prosthetic implants became an attractive concept. A number of different methods of obtaining an endothelial lining of prosthetic material has since been developed; these include facilitated endothelial cell migration, and endothelial cell seeding by using either venous or microvascular endothelial cells. Manipulating the endothelium might well provide the next major advancement for therapeutic and preventive measures for cardiovascular disease.

Arteriosclerosis↗

Long-term results of tissue development and cell differentiation on Dacron prostheses seeded with microvascular cells in dogs.

PURPOSE: The purpose of this study was to investigate in vivo the long-term development, differentiation, and proliferation of the subendothelial tissue on Dacron prostheses seeded with microvascular cells (MVC). METHODS: Autologous MVC from omental adipose tissue were seeded on 4 mm Dacron prostheses and the prostheses interposed in the carotid arteries of mongrel dogs for 5, 13, and 26 weeks. RESULTS: Light and electron microscopic evaluation of patent seeded prostheses demonstrated an almost complete monolayer of endothelial cells and well-organized subendothelial tissue, whereas patent control prostheses were mainly covered by red and white thrombi, which were partially replaced by organized tissue with increased implantation time. The measurements of the thickness of the luminal cell layer in seeded and control grafts showed no statistically significant increase between 5 and 26 weeks of implantation. The subendothelial tissue of seeded prostheses demonstrated a time-dependent maturation of highly synthesizing myofibroblasts embedded in a collagen matrix to cells with features of smooth muscle cells located in a collagen-elastin matrix. In control grafts examined after 26 weeks the spontaneous endothelialization was accompanied by a delayed or incomplete maturation of subendothelial tissue. CONCLUSIONS: Our study indicates that MVC seeded onto Dacron prostheses are able to generate a vascular wall that does not continue to proliferate after prolonged implantation and that increasingly resembles the wall of a normal artery in cell differentiation and intercellular matrix.

Animals↗

Experimental in vitro endothelialization of cardiac valve leaflets.

This study reports our results with vitro endothelialization of fresh nonpreserved homograft valve leaflets compared with mild alternatively preserved valves and valves treated by preservation procedures commonly used for commercially available tissue valves. In vitro lining of biological heart valves with cultured autologous endothelial cells might help prevent the detrimental effects of degeneration on valve durability. To investigate the growth characteristics of endothelial cells on valve bioprostheses, three different methods of storage and preservation were compared. After precoating with fibronectin and seeding of 4.4 x 10(4) endothelial cells/cm2 onto the different leaflet surfaces, primary adherence, growth kinetics, morphology, and maintenance of monolayer integrity were studied over a period of 10 days. On valve leaflet surfaces of group 1 (fresh nonpreserved homograft valve leaflets) and group 2 (mild alternatively preserved valves), endothelial cells grew to persistent monolayers between days 6 and 10. In contrast, endothelial cell proliferation with monolayer growth could not be achieved on the group 3 leaflets (preserved like commercially available biological valve prostheses). In that group, no viable endothelial cells could be found on the valve surfaces 2 days after seeding. These results demonstrate the theoretical feasibility of endothelializing biological heart valve leaflets in vitro if they are not preserved and stored according to commonly used procedures. Provided such an endothelium can withstand the mechanical forces after implantation in vivo, in vitro endothelialization might contribute either to the development of new biological heart valves for modern cardiac surgery or to the improvement of clinical results with homograft valve transplants.

Bioprosthesis↗