P Weir

Publications and source records attributed to P Weir.

27 records · Page 2Linked to original sources

Experimental and predicted dual oximetry variability.

OBJECTIVE: We wished to determine whether the individual bias (mean difference) and precision (standard deviation of the difference) values of 2 variables, arterial oxygen saturation (SaO2) and mixed venous oxygen saturation (SvO2), could be used to predict the bias and precision values of the combined dual oximetry variable (SaO2-SvO2). METHODS: We simultaneously measured SaO2 by pulse oximetry and arterial blood gas co-oximetry and SvO2 by fiberoptic reflectance oximetry pulmonary artery catheter and venous blood gas co-oximetry in 238 data sets from 55 patients. Three different methods were used to predict the standard deviation of the difference of (SaO2-SvO2) [s delta(SaO2-SvO2)]: simple sum, root mean square (RMS) error, and RMS error with correction term. We derived the equation for the RMS error with correction term because initial results showed that the simple sum and RMS error methods did not predict s delta(SaO2-SvO2) well. The correction term accounts for the non-independence of simultaneous SaO2 and SvO2 measurements. RESULTS: The observed overall bias of the SaO2, SvO2, and (SaO2-SvO2) measurement methods were 0.17, -1.76, and 1.94, respectively. The observed overall s delta(SaO2-SvO2) of the (SaO2-SvO2) measurement method was 5.12. The simple sum method overestimated the actual s delta(SaO2-SvO2) by 38%, the RMS error method differed from the actual s delta(SaO2-SvO2) by 3%, and the RMS error with correction term method matched the actual s delta(SaO2-SvO2). CONCLUSION: The bias of a (SaO2-SvO2) measurement method is simply the bias of the SaO2 measurement method less the bias of the SvO2 measurement method. s delta(SaO2-SvO2) is best predicted by the derived equation, RMS error with correction term. The same principles and equations also apply to other situations in which 2 variables with the same dimensions are combined into 1 variable, such as (PaCO2-EtCO2) gradients and perfusion-pressure gradients. Although the difference between the s delta(SaO2-SvO2) predicted by the RMS error equation and the derived RMS error equation with correction term was small, the difference may be significant for other combined variables.

Oximetry↗

Which tests are most useful in distinguishing between reactive thrombocytosis and the thrombocytosis of myeloproliferative disease?

In an attempt to distinguish between thrombocytosis in myeloproliferative disease (MPD) and reactive thrombocytosis (RT) the following aspects of platelet structure and function were evaluated: platelet size, platelet aggregation and adhesion, dense granule and alpha granule components. In addition plasma fibrinogen and von Willebrand factor antigen (vWFag) were measured. In all parameters measured there was a significant difference between normals and both categories of thrombocytosis, however there was considerable overlap between MPD and RT. Plasma fibrinogen emerged as the best single test to discriminate between MPD and RT, levels of less than 5.0 g/l indicating MPD and greater than 5.0 g/l indicating RT.

Antigens↗

Idiopathic chronic disseminated intravascular coagulation.

Disseminated intravascular coagulation, whether acute or chronic is usually associated with an underlying causative condition. In this case chronic disseminated intravascular coagulation persisted in one 79 year old man for 3 years with no detectable underlying cause.

Aged↗