Search PubMed⌕ Search

Biomedical subjects

P Van der Meeren

Publications and source records attributed to P Van der Meeren.

8 recordsLinked to original sources

The importance of the cosolvent propylene glycol on the antimicrobial preservative efficacy of a pharmaceutical formulation by DOE-ruggedness testing.

The aim of this study was to statistically evaluate the influence of the concentration of the co-solvent propylene glycol on the preservative efficacy of a complex pharmaceutical suspension-emulsion formulation containing methyl- and propylparaben. Preservative Efficacy Tests (PETs) were performed using the validated pharmacopoeial methodology with five test organisms over 1 month on lab-scale test formulations. These were independently prepared according to a Box-Behnken experimental design with a triplicate central point at 0.22% m/m methylparaben, 0.22% m/m propylparaben, and 2.75% m/m propylene glycol, and with an additional corner point of the Box-Behnken cube. We evaluated the preservative efficacies against the criteria of the United States Pharmacopeia (USP) and European Pharmacopoeias (PhEur) for formulations for oral use, as well as by the statistical comparison of the slopes obtained by linear regression of log (CFU/g) vs. time. With an initial bacterial challenge of 10(6) CFU/g for each of the three bacterial strains, no survivals were detected after 7 days. For the two fungal strains, box plots and analysis of variance showed significant, concentration-dependent, main effects: the three variables significantly influenced the kill-rate of C. albicans, while A. niger was predominantly influenced by the cosolvent propylene glycol, and only to a minor extent by methylparaben and not at all by propylparaben. These findings were confirmed by taking the pharmacopoeial criteria as the evaluation basis, where the dominant influence of propylene glycol concentration is apparent. It was concluded that the cosolvent propylene glycol is at least of equal preservative importance than both parabens.

Anti-Infective Agents↗

Bench- and pilot-scale sludge electrodewatering in a diaphragm filter press.

Electrodewatering is a technique in which pressure dewatering is combined with electrokinetic effects to realize an improved solid/liquid separation and hence increased filter cake dry matter contents. In order to be energy efficient, it is shown that sludge should be dewatered by pressure dewatering to a high extent prior to electric field application, and a sufficient contact time for the electric field must be guaranteed. In order to realize these goals, a bench- and pilot-scale diaphragm filter press suited for electrodewatering were constructed for treatment of sewage and other types of sludges. It was shown that electrodewatering of sludge is a feasible technique, especially for biological sludge types. Other types of sludge are less suited for electrodewatering because of the restricted improvements that can be realized in cake dry matter content and the high electric energy consumption. Furthermore, it was shown in pilot-scale tests that the use of a diaphragm filter press with electrodewatering facilities was very well suited to deliver dry filter cakes of sewage sludge at a moderate energy consumption. Depending on local market prices for investment, operating and sludge disposal costs, this technology may therefore lead to important savings in the sludge management process.

Electrochemistry↗

Simultaneous determination of activated sludge floc size distribution by different techniques.

The activated sludge floc size distribution (FSD) is investigated by using different techniques and the results are compared against each other in order to gain insight into the FSD characteristics, as well as to detect the limitations of each measurement technique. The experimental set-up consisted of three devices coupled in series: a MastersizerS, an automated image analysis system (IMAN) and a CIS-100. The latter instrument has two measurement channels, based on time of transition (TOT), and image analysis (SHAPE) principles. In order to minimise the variability between successive measurements, the activated sludge samples collected from a pilot-scale SBR were flocculated until steady state was achieved. The results show that the MastersizerS and SHAPE devices yield similar volume weighted FSD. In contrast, the IMAN overestimated the floc size and TOT frequently showed a bimodal distribution. The number distributions from TOT and SHAPE were in agreement, while those generated by the MastersizerS were mainly located in the submicron range and those of IMAN corresponded to larger sizes. The experimental distributions show a good fit to the log-normal model. It is shown that the measurement principle is of utmost importance and results transformation may lead to data misinterpretation.

Biotechnology↗

Linking floc structure and settling properties to activated sludge population dynamics in an SBR.

Over a period of 227 days properties of activated sludge grown in an sequencing batch reactor (SBR) operated under stable conditions were analyzed. Settling properties (sludge volume index (SVI)) of the activated sludge were compared with on-line measurements of floc size and size distribution obtained by using a laser light scattering technique (Malvern Mastersizer/S, Malvern, UK), and with measurements of microbial community dynamics analyzed by denaturing gradient gel electrophoresis (DGGE) patterns of 16S rRNA genes. In addition, microscopical observations were used to confirm the results. Three distinct stages in the SBR evolution were observed. In the first stage the structural floc properties showed predominant presence of floc-forming bacteria in the activated sludge. A good correlation between floc size, properties and microbial community evolution was observed. The second stage showed a good balance between floc-forming and filamentous bacteria, with good settling properties and a highly dynamic community in the SBR. In the third stage, an increase in the filamentous bacteria, which became predominant in the system was observed. Again, a good correlation between settling properties and floc size distribution was obtained and a new dominant species was observed in the DGGE patterns, which can be assumed to be a filamentous organism.

Bioreactors↗

Simulation of drift of pesticides: development and validation of a model.

Over the last decade drift of pesticides has been recognized as a major problem for the environment. High fractions of pesticides can be transported through the air and deposited in neighbouring ecosystems during and after application. A new computer-two steps-drift model is developed: FYDRIMO or F(ph)Ysical DRift MOdel. In the first step the droplet size spectrum of a nozzle is analysed. In this way the volume percentage of droplets with a certain size is known. In the second step the model results in a prediction of deposition of each droplet with a certain size. This second part of the model runs in MATLAB and is grounded on a combination of two physical factors: gravity force and friction forces. In this stage of development corrections are included for evaporation and wind force following a certain measured wind profile. For validation wind tunnel experiments were performed. Salt solutions were sprayed at two wind velocities and variable distance above the floor. Small gutters in the floor filled with filter paper were used to collect the sprayed droplets. After analysing and comparing the wind tunnel results with the model predictions, FYDRIMO seems to have good predicting capacities.

Aerosols↗

The effect of adjuvants on atomisation of pesticides.

Four surfactants Tween 20, Agral 90, Silwet L77 and Break Thru, commonly used in the formulations of agricultural products, were evaluated on their spray performance and dynamic surface tension. In a spray test the Dv 50 (micron) or the Volume Median Diameter and the percentage of droplets with diameter below 100 microns (drift sensitive droplets), were measured for different kind of nozzles varying from the classical flat fan up to the low drift nozzles. The spectra changed considerably when different kind of nozzles and different kind of surfactants were used, the concentration effect was less important. The dynamic tension of the different surfactant solutions could not always explain the changes in droplet spectrum.

Aerosols↗

Enhanced sludge dewatering by electrofiltration. A feasibility study.

Sludge treatment is a major issue in today's waste water treatment. One of the problems encountered is the limiting dewaterability of mainly biological sludges, causing high final treatment costs for incineration or landfill. Although during recent years, improvements are realised in the field of dewatering, the actual dry solids content after dewatering remains at a maximum value of about 35%. In order to increase the dry solids content, the technique of electrofiltration was investigated. Electrofiltration is the combination of two known techniques, traditional pressure filtration and electroosmotic/electrophoretic dewatering. Pressure filtration is based on pressure as the driving force for dewatering a sludge. Limitations hereby lie in the clogging of the filter cloth due to the build-up of the filtercake. Electroosmotic/electrophoretic dewatering is based on an electric field to separate sludge colloid particles from the surrounding liquid by placing the sludge liquor between two oppositely charged electrodes. In this case, mobile sludge particles will move to one electrode due to their natural surface charge, and the liquid phase will be collected at the oppositely charged electrode. Combination of both techniques makes it possible to create a more homogeneous filter cake and prevent the filter from clogging, resulting in higher cake dry solids contents and shorter filtration cycles. To investigate the feasibility of this technique for the dewatering of activated sludge, a filter unit was developed for investigations on lab scale. Multiple dewatering tests were performed in which the electric parameters for electrofiltration were varied. It was derived from these experiments that very high filter cake dry solids contents (to more than 60%), and short filtration cycles were attainable by using a relatively small electric DC field. The power consumption was very low compared to the power needed to dewater sludge by thermal drying techniques. For this reason, this technique seems very promising for the dewatering of biological sludges.

Electrochemistry↗