Search PubMed⌕ Search

Biomedical subjects

P V Scott

Publications and source records attributed to P V Scott.

At least 19 recordsLinked to original sources

Second and subsequent surgical operations within 12 months of a first operation.

In a retrospective study, all patients having anaesthetic procedures within a 3-month period were identified and followed up to establish if they had further procedures within a calendar year. The procedures undertaken on these patients were then identified to establish if a relationship existed between the procedures and what that relationship was. 11% of all patients returned for further procedures, 80% of which were within the same surgery specialty. In the overwhelming majority, the subsequent procedures were related to the first either as planned courses of treatment or by complications of the surgery or the disease process. The relationship between the procedures and their time intervals is discussed.

England↗

Vaporisers.

Explore the source record for details and available documents.

Anesthesia, Inhalation↗

Control of end-tidal carbon dioxide during IPPV. Variable functional apparatus deadspace.

We have described a method for control of end-tidal carbon dioxide tension during intermittent positive pressure ventilation in a model lung and in 19 adults during general anaesthesia supplemented by central or peripheral neural blockade. The inspiratory and expiratory limbs of an open or a circle anaesthesia system were interconnected and ventilated simultaneously in a variable manner during inspiration. The flow of mixed-expired gas, normally one-way, became to-and-fro (variable functional apparatus deadspace, or "virtual' deadspace). At minute volume ventilation > or = 100 ml.kg-1.min-1 (patients), the value of end-tidal carbon dioxide tension was varied reproducibly within the range 4.1-6.5 (SD 0.1)kPa independently of fresh gas flow or other prescribed patterns of ventilation. At a steady state, stable nominated values of end-tidal carbon dioxide tension within the range were attained. By how much any given intra-operative value of end-tidal carbon dioxide tension may be said to affect peri-operative outcome is debatable, but during surgery any change in a nominated value may usefully indicate a change in the steady state.

Adult↗

Asystole from tetanic stimulation of the accessory nerve.

An asystolic cardiac arrest is reported which occurred at the same time as supramaximal tetanic stimulation over the accessory nerve in order to evoke contractions in the trapezius and sternocleidomastoid muscles. The cause may have been the inadvertent stimulation of one or more of the cranial nerves of the carotid sheath at the base of the skull: the cranial root of the accessory nerve, the vagus, the sino-carotid branch of the glossopharyngeal nerve or the hypoglossal nerve. The most likely culprit, if not the vagus itself, was the cranial root of the accessory nerve which both functionally and anatomically should be seen as an integral part of the vagus. It is suggested that stimulation of any nerve in the carotid sheath should be approached with caution and that a tetanic stimulus to this area might best be avoided.

Accessory Nerve↗

Whistle blowing.

Explore the source record for details and available documents.

Personnel Loyalty↗

An analogue approach to audit in anaesthesia.

The predicted outcome of anaesthesia and surgery was compared with the immediate outcome in 508 patients by means of two 100 mm linear analogue scales. The results were used to obtain a statistically based rule by which the anaesthetist may consistently select three groups of patients for audit: group 1, patients in whom immediate outcome of anaesthesia and surgery is worse than predicted; group 2, patients whose outcome is better than predicted; and group 3, the remaining patients. The rule, which is simply adapted to departmental audit, does not necessarily need a computer but is suited to the computer as it is numerically based.

Adult↗

Variable apparatus deadspace.

A variable apparatus deadspace was used to maintain normocapnia during artificial ventilation of the lungs in anaesthetised adults. End-tidal carbon dioxide tension could be varied, if the need arose, within the range 4.0-5.2 kPa in both open and circle breathing systems when a fixed tidal volume of 12 ml.kg-1 and minute volume ventilation of 120 ml.kg-1.min-1 were employed.

Abdomen↗